997 resultados para 1583-1641.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Some studies of patients with acute myocardial infarction have reported that hyperglycaemia at admission may be associated with a worse outcome. This study sought to evaluate the association of blood glucose at admission with the outcome of unselected patients with acute coronary syndrome (ACS). Using the Acute Myocardial Infarction and unstable angina in Switzerland (AMIS Plus) registry, ACS patients were stratified according to their blood glucose on admission: group 1: 2.80-6.99 mmol/L, group 2: 7.00-11.09 mmol/L and group 3: > 11.10 mmol/L. Odds ratios for in-hospital mortality were calculated using logistic regression models. Of 2,786 patients, 73% were male and 21% were known to have diabetes. In-hospital mortality increased from 3% in group 1 to 7% in group 2 and to 15% in group 3. Higher glucose levels were associated with larger enzymatic infarct sizes (p<0.001) and had a weak negative correlation with angiographic or echographic left ventricular ejection fraction. High admission glycaemia in ACS patients remains a significant independent predictor of in-hospital mortality (adjusted OR 1.08; 95% confidence intervals [CI] 1.05-1.14, p<0.001) per mmol/L. The OR for in-hospital mortality was 1.04 (95% CI 0.99-1.1; p=0.140) per mmol/L for patients with diabetes but 1.21 (95% CI 112-1.30; p<0.001) per mmol/L for non-diabetic patients. In conclusion, elevated glucose level in ACS patients on admission is a significant independent predictor of in-hospital mortality and is even more important for patients who do not have known diabetes.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To elucidate the association of impaired pulmonary status (IPS) and diabetes mellitus (DM) with clinical outcome and the incidences of aortic neck dilatation and type I endoleak after elective endovascular infrarenal aortic aneurysm repair (EVAR). METHODS: In 164 European institutions participating in the EUROSTAR registry, 6383 patients (5985 men; mean age 72.4+/-7.6 years) underwent EVAR. Patients were divided into patients without versus with IPS or with/without DM. Clinical assessment and contrast-enhanced computed tomography (CT) were performed at 1, 3, 6, 12, 18, and 24 months and annually thereafter. Cumulative endpoint analysis comprised death, aortic rupture, type I endoleak, endovascular reintervention, and surgical conversion. RESULTS: Prevalence of IPS was 2733/6383 (43%) and prevalence of DM was 810/6383 (13%). Mean follow-up was 21.1+/-18.4 months. Thirty-day mortality, AAA rupture, and conversion rates did not differ between patients with versus without IPS and between patients with versus without DM. All-cause and AAA-related mortality, respectively, were significantly higher in patients with IPS compared to patients with normal pulmonary status (31.0% versus 19.0%, p<0.0001 and 6.8% versus 3.3%, p = 0.0057) throughout follow-up. In multivariate analysis adjusted for smoking, age, gender, comorbidities, fitness for open repair, co-existing common iliac aneurysm, neck and aneurysm size, arterial angulations, aneurysm classification, endograft oversizing >or=15%, and type of stent-graft, the presence of IPS was not associated with significantly higher rates of aortic neck dilatation (30.6% versus 38.0%, p>0.05) and did not influence cumulative rates of type I endoleak, endovascular reintervention, or conversion to open surgery (p>0.05). Similarly, the presence of DM did not influence the above-mentioned study endpoints. CONCLUSION: In contrast to observations regarding the natural course of AAAs, impaired pulmonary status does not negatively influence aortic neck dilatation, while the presence of diabetes does not protect from these dismal events after EVAR.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To evaluate and compare the efficacy of proximal versus distal embolus protection devices (EPD) during carotid artery angioplasty/stenting (CAS) based on diffusion-weighted magnetic resonance imaging (DW-MRI). METHODS: Forty-four patients (31 men; mean age 68 years, range 48-85) underwent protected CAS and had DW-MRI before and after the intervention. The cohort was analyzed according to the type of EPD used: a proximal EPD was deployed in 25 (56.8%) patients (17 men; mean age 66 years, range 48-85) and a distal filter in 19 (14 men; mean age 70 years, range 58-79). Fifteen (60.0%) patients with proximal protection were symptomatic of the target lesion; in the distal protection group, 10 (52.6%) were symptomatic. RESULTS: New lesions were seen on the postinterventional DW-MRI in 28.0% (7/25) of the proximal EPD group versus 32.6% (6/19) of those with a distal filter (p = NS). The majority were clinically silent. The new lesions in the vascular territory of the stented carotid artery in the group as a whole and per patient were fewer in the proximal EPD group (p = NS). No significant differences were noted in the T(2) appearance of the new lesions or the number of new lesions observed away from the vascular territory of the stented artery. CONCLUSION: Proximal embolus protection devices show a nonsignificant trend toward fewer embolic events, which warrants large-scale studies. Furthermore, proximal protection devices can be useful to control and treat acute in-stent thrombosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To investigate the impact of filter design on blood flow impairment in the internal carotid artery (ICA) among patients undergoing carotid artery stenting (CAS) using filter-type emboli protection devices (EPD). METHODS: Between July 2003 and March 2007, 115 filter-protected CAS procedures were performed at an academic institution in 107 consecutive patients (78 men; mean age 68 years, range 38-87). The Angioguard, FilterWire EZ, and Spider filters were used in 68 (59%), 32 (28%), and 15 (13%) of cases, respectively. Patient characteristics, procedural and angiographic data, and outcomes were prospectively entered into an electronic database and reviewed retrospectively along with all angiograms. RESULTS: Flow impairment while the filter was in place was observed in 25 (22%) cases. The presumptive reason of flow impairment was filter obstruction in 21 (18%) instances and flow-limiting spasm at the level of the filter in 4 (4%). In all cases, flow was restored after retrieval of the filter. Flow obstruction in the ICA occurred more frequently with Angioguard (22/68; 32.3%) than with FilterWire EZ (2/32; 6.2%) or Spider (1/15; 6.7%; p = 0.004). No flow occurred in 13 (19%) procedures, all of them protected with Angioguard; no patient treated with other devices experienced this event (p = 0.007). Two (8.0%) strokes occurred in procedures associated with flow impairment, while 1 (1.1%) event was observed in the presence of preserved flow throughout the intervention (p = 0.11). CONCLUSION: Flow impairment in the ICA during filter-based CAS is common and related to the type of filter used.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Oxidative stress, intense light exposure and oxygen imbalances such as hypoxic or hyperoxic conditions perturb mitochondria, nuclear function and further lead to cellular damage of retina and retinal pigment epithelial (RPE) cells. Our major aim is to understand the various biochemical and proteomic events that occur during the progression of retina and RPE cell death. The comprehensive objectives of this dissertation are to understand the functional aspects of protein expression, posttranslational modifications, protein or lipid binding changes, phenotypic, morphological alterations and their regulation during the retina and RPE apoptosis under oxidative stress. The entire study is divided into four chapters Chapter 1 contains introduction and background on apoptotic signaling in retina and RPE cells. In chapter 2, we demonstrated that the oxidative stress biomarker prohibitin shuttles between mitochondria and nucleus as an anti-apoptotic molecule and acts as a transcriptional regulator by altering its lipid binding affinity and by posttranslational modifications during oxidative damage to the retina and RPE. In chapter 3, we demonstrated that oxidative and photo-oxidative stress induced nitric oxide regulates the RPE apoptosis by altering serine/threonine protein phosphatase 2A (PP2A) catalytic subunit, vimentin phosphorylation and Bcl xL expression regulation in the RPE cells in vitro. In chapter 4, we further analyzed the differential expression of prohibitin in the retina and RPE during oxidative stress, diabetic retinopathy (DR) and age-related macular degeneration (AMD) condition. Our analysis of postmortem retinas reveals that prohibitin is significantly increased in aged and AMD retina, and decreased in retinas of human diabetic retinopathy and RPE of AMD. Our study demonstrates that prohibitin levels determine the apoptotic signaling in the retina and RPE during retinal degenerative disease progression.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Liquid films, evaporating or non-evaporating, are ubiquitous in nature and technology. The dynamics of evaporating liquid films is a study applicable in several industries such as water recovery, heat exchangers, crystal growth, drug design etc. The theory describing the dynamics of liquid films crosses several fields such as engineering, mathematics, material science, biophysics and volcanology to name a few. Interfacial instabilities typically manifest by the undulation of an interface from a presumed flat state or by the onset of a secondary flow state from a primary quiescent state or both. To study the instabilities affecting liquid films, an evaporating/non-evaporating Newtonian liquid film is subject to a perturbation. Numerical analysis is conducted on configurations of such liquid films being heated on solid surfaces in order to examine the various stabilizing and destabilizing mechanisms that can cause the formation of different convective structures. These convective structures have implications towards heat transfer that occurs via this process. Certain aspects of this research topic have not received attention, as will be obvious from the literature review. Static, horizontal liquid films on solid surfaces are examined for their resistance to long wave type instabilities via linear stability analysis, method of normal modes and finite difference methods. The spatiotemporal evolution equation, available in literature, describing the time evolution of a liquid film heated on a solid surface, is utilized to analyze various stabilizing/destabilizing mechanisms affecting evaporating and non-evaporating liquid films. The impact of these mechanisms on the film stability and structure for both buoyant and non-buoyant films will be examined by the variation of mechanical and thermal boundary conditions. Films evaporating in zero gravity are studied using the evolution equation. It is found that films that are stable to long wave type instabilities in terrestrial gravity are prone to destabilization via long wave instabilities in zero gravity.

Relevância:

10.00% 10.00%

Publicador:

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: To evaluate the association of adequate allocation concealment and patient blinding with estimates of treatment benefits in osteoarthritis trials. METHODS: We performed a meta-epidemiologic study of 16 meta-analyses with 175 trials that compared therapeutic interventions with placebo or nonintervention control in patients with hip or knee osteoarthritis. We calculated effect sizes from the differences in means of pain intensity between groups at the end of followup divided by the pooled SD and compared effect sizes between trials with and trials without adequate methodology. RESULTS: Effect sizes tended to be less beneficial in 46 trials with adequate allocation concealment compared with 112 trials with inadequate or unclear concealment of allocation (difference -0.15; 95% confidence interval [95% CI] -0.31, 0.02). Selection bias associated with inadequate or unclear concealment of allocation was most pronounced in meta-analyses with large estimated treatment benefits (P for interaction < 0.001), meta-analyses with high between-trial heterogeneity (P = 0.009), and meta-analyses of complementary medicine (P = 0.019). Effect sizes tended to be less beneficial in 64 trials with adequate blinding of patients compared with 58 trials without (difference -0.15; 95% CI -0.39, 0.09), but differences were less consistent and disappeared after accounting for allocation concealment. Detection bias associated with a lack of adequate patient blinding was most pronounced for nonpharmacologic interventions (P for interaction < 0.001). CONCLUSION: Results of osteoarthritis trials may be affected by selection and detection bias. Adequate concealment of allocation and attempts to blind patients will minimize these biases.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Our goal was to validate accuracy, consistency, and reproducibility/reliability of a new method for determining cup orientation in total hip arthroplasty (THA). This method allows matching the 3D-model from CT images or slices with the projected pelvis on an anteroposterior pelvic radiograph using a fully automated registration procedure. Cup orientation (inclination and anteversion) is calculated relative to the anterior pelvic plane, corrected for individual malposition of the pelvis during radiograph acquisition. Measurements on blinded and randomized radiographs of 80 cadaver and 327 patient hips were investigated. The method showed a mean accuracy of 0.7 +/- 1.7 degrees (-3.7 degrees to 4.0 degrees) for inclination and 1.2 +/- 2.4 degrees (-5.3 degrees to 5.6 degrees) for anteversion in the cadaver trials and 1.7 +/- 1.7 degrees (-4.6 degrees to 5.5 degrees) for inclination and 0.9 +/- 2.8 degrees (-5.2 degrees to 5.7 degrees) for anteversion in the clinical data when compared to CT-based measurements. No systematic errors in accuracy were detected with the Bland-Altman analysis. The software consistency and the reproducibility/reliability were very good. This software is an accurate, consistent, reliable, and reproducible method to measure cup orientation in THA using a sophisticated 2D/3D-matching technique. Its robust and accurate matching algorithm can be expanded to statistical models.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Endovascular aneurysm repair has matured significantly over the last 20 years and is becoming increasingly popular as a minimally invasive treatment option for patients with abdominal aortic aneurysms (AAA). Long-term durability of this fascinating treatment, however, is in doubt as continuing aneurysmal degeneration of the aortoiliac graft attachment zones is clearly associated with late adverse sequelae. In recent years, our growing understanding of the physiopathology of AAA formation has facilitated scrutiny of various potential drug treatment concepts. In this article we review the mechanical and biological challenges associated with endovascular treatment of infrarenal AAAs and discuss potential approaches to ongoing aneurysmal degeneration, which hampers long-term outcomes of this minimally invasive therapy.