893 resultados para ventricular assist device


Relevância:

20.00% 20.00%

Publicador:

Resumo:

It is still imperative to develop a parasitological technique highly sensitive for diagnosing schistosomiasis in epidemiological and individual surveys. A simple and cheap hatching device with a collecting container was manufactured and tested under experimental conditions. Twelve Kato-Katz slides were performed as golden standard for comparison. Quantitative results can be carried out by counting miracidia in a plate and parasite load can be calculated (miracidia/gram of feces). Statistically significant values were higher in the hatching test. More sensitive results, with statistical significance, were achieved using 1.5 g of feces (which corresponds to 36 Kato-Katz slides) than by using the Kato-Katz method. Advantages of this technique and its limitations are presented.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

ABSTRACT: BACKGROUND: In acute myocardial infarction (AMI), both tissue necrosis and edema are present and both might be implicated in the development of intraventricular dyssynchrony. However, their relative contribution to transient dyssynchrony is not known. Cardiovascular magnetic resonance (CMR) can detect necrosis and edema with high spatial resolution and it can quantify dyssynchrony by tagging techniques. METHODS: Patients with a first AMI underwent percutaneous coronary interventions (PCI) of the infarct-related artery within 24 h of onset of chest pain. Within 5-7 days after the event and at 4 months, CMR was performed. The CMR protocol included the evaluation of intraventricular dyssynchrony by applying a novel 3D-tagging sequence to the left ventricle (LV) yielding the CURE index (circumferential uniformity ratio estimate; 1 = complete synchrony). On T2-weighted images, edema was measured as high-signal (>2 SD above remote tissue) along the LV mid-myocardial circumference on 3 short-axis images (% of circumference corresponding to the area-at-risk). In analogy, on late-gadolinium enhancement (LGE) images, necrosis was quantified manually as percentage of LV mid-myocardial circumference on 3 short-axis images. Necrosis was also quantified on LGE images covering the entire LV (expressed as %LV mass). Finally, salvaged myocardium was calculated as the area-at-risk minus necrosis (expressed as % of LV circumference). RESULTS: After successful PCI (n = 22, 2 female, mean age: 57 ± 12y), peak troponin T was 20 ± 36ug/l and the LV ejection fraction on CMR was 41 ± 8%. Necrosis mass was 30 ± 10% and CURE was 0.91 ± 0.05. Edema was measured as 58 ± 14% of the LV circumference. In the acute phase, the extent of edema correlated with dyssynchrony (r2 = -0.63, p < 0.01), while extent of necrosis showed borderline correlation (r2 = -0.19, p = 0.05). PCI resulted in salvaged myocardium of 27 ± 14%. LV dyssynchrony (=CURE) decreased at 4 months from 0.91 ± 0.05 to 0.94 ± 0.03 (p < 0.004, paired t-test). At 4 months, edema was absent and scar %LV slightly shrunk to 23.7 ± 10.0% (p < 0.002 vs baseline). Regression of LV dyssynchrony during the 4 months follow-up period was predicted by both, the extent of edema and its necrosis component in the acute phase. CONCLUSIONS: In the acute phase of infarction, LV dyssynchrony is closely related to the extent of edema, while necrosis is a poor predictor of acute LV dyssynchrony. Conversely, regression of intraventricular LV dyssynchrony during infarct healing is predicted by the extent of necrosis in the acute phase.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: Intracoronary administration of autologous bone marrow-derived mononuclear cells (BM-MNC) may improve remodeling of the left ventricle (LV) after acute myocardial infarction. The optimal time point of administration of BM-MNC is still uncertain and has rarely been addressed prospectively in randomized clinical trials. METHODS AND RESULTS: In a multicenter study, we randomized 200 patients with large, successfully reperfused ST-segment elevation myocardial infarction in a 1:1:1 pattern into an open-labeled control and 2 BM-MNC treatment groups. In the BM-MNC groups, cells were administered either early (ie, 5 to 7 days) or late (ie, 3 to 4 weeks) after acute myocardial infarction. Cardiac magnetic resonance imaging was performed at baseline and after 4 months. The primary end point was the change from baseline to 4 months in global LV ejection fraction between the 2 treatment groups and the control group. The absolute change in LV ejection fraction from baseline to 4 months was -0.4±8.8% (mean±SD; P=0.74 versus baseline) in the control group, 1.8±8.4% (P=0.12 versus baseline) in the early group, and 0.8±7.6% (P=0.45 versus baseline) in the late group. The treatment effect of BM-MNC as estimated by ANCOVA was 1.25 (95% confidence interval, -1.83 to 4.32; P=0.42) for the early therapy group and 0.55 (95% confidence interval, -2.61 to 3.71; P=0.73) for the late therapy group. CONCLUSIONS: Among patients with ST-segment elevation myocardial infarction and LV dysfunction after successful reperfusion, intracoronary infusion of BM-MNC at either 5 to 7 days or 3 to 4 weeks after acute myocardial infarction did not improve LV function at 4-month follow-up. CLINICAL TRIAL REGISTRATION: URL: http://www.clinicaltrials.gov. Unique identifier: NCT00355186.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION. Neurally Adjusted Ventilatory Assist (NAVA) is an assisted ventilatorymode in which the ventilator is driven by the electrical activity of the diaphragm (Eadi).NAVAimproves patient-ventilator synchrony [1] but little is known about how to set the NAVA gaini.e., how to choose the ratio between Eadi and delivered pressure. The aim of the present studywas to assess the relationship between Eadi and tidal volume (Vt) at various NAVA gainsettings and to evaluate whether modifying the gain influenced this relationship in non-invasivelyventilated (NIV) patients.METHODS. Prospective interventional study comparing 3 values of NAVA gain during NIV(20 min each). NAVA100 was set by the clinician according to the manufacturer's recommendations.In NAVA50 and NAVA150 the gain was set as -50% and +50% of NAVA100gain respectively. Vt and maximal Eadi value (Eadi max) were recorded. The ratio Vt/Eadi wasthen assessed for each breath. 5-95% range (range 90) of Vt/Eadi was calculated for eachpatient at each NAVA gain setting. Vt/Eadi ratio has the advantage to give an objectiveassessment Vt/Eadi max relationship independently from the nature of this relationship. Asmaller Range90 indicates a better matching of Vt to Eadi max.RESULTS. 12 patients were included, 5 had obstructive pulmonary disease and 2 mixedobstructive and restrictive disease. For NAVA100, the median [IQR] Range 90 was 32[19-87]. For NAVA150 Range 90 was 37 [20-95] and for NAVA50 Range 90 was 33 [16-92].That means that globally NAVA100 allowed a better match between Eadi max and Vt thanNAVA50 and 150. However, by patient, NAVA100 had the lowest Range 90 value for only 4patients (33%), NAVA150 for 2 (17%) and NAVA50 for 6 (50%) patients, indicating thatNAVA100 was not the best NAVA gain for minimizing Range 90 in every patients.Comparing the lowest Range 90 value to the next lowest for each patient, showed that 3 patientshad differences of less than 10% (one each for NAVA50, NAVA100 and NAVA150). Theremainder had differences from 17 to 24%, indicating that most patients (9/12 or 75%) had aclear better match between Eadi and Vt for one specific NAVA gain.CONCLUSIONS. Different NAVA gains yielded markedly different ability to match Vt toEadi max. This approach could be a new way to determine optimalNAVAgain for each patientbut require further investigations.REFERENCE. Piquilloud L, et al. Intensive Care Med 2011;37:263-71.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction : Le monitoring de la tension artérielle à domicile est recommandé par plusieurs guidelines et a été montré être faisable chez la personne âgée. Les manomètres au poignet ont récemment été proposés pour la mesure de la tension artérielle à domicile, mais leur précision n'a pas été au préalable évaluée chez les patients âgés. Méthode : Quarante-huit participants (33 femmes et 15 hommes, moyenne d'âge 81.3±8.0 ans) ont leur tension artérielle mesurée avec un appareil au poignet avec capteur de position et un appareil au bras dans un ordre aléatoire et dans une position assise. Résultats : Les moyennes de mesures de tension artérielle étaient systématiquement plus basses avec l'appareil au poignet par rapport à celui du bras pour la pression systolique (120.1±2.2 vs. 130.5±2.2 mmHg, P < 0.001, moyenneidéviation standard) et pour la pression diastolique (66.011.3 vs. 69.7±1.3 mmHg, P < 0.001). De plus, une différence de lOmmHg ou plus grande entre l'appareil au bras et au poignet était observée dans 54.2 et 18,8% des mesures systoliques et diastoliques respectivement. Conclusion : Comparé à l'appareil au bras, l'appareil au poignet avec capteur de position sous-estimait systématiquement aussi bien la tension artérielle systolique que diastolique. L'ampleur de la différence est cliniquement significative et met en doute l'utilisation de l'appareil au poignet pour monitorer la tension artérielle chez la personne âgée. Cette étude indique le besoin de valider les appareils de mesures de la tension artérielle dans tous les groupes d'âge, y compris les personnes âgées.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

El projecte es va fer al KHLim a Diepenbeek. Es tractava de dissenyar un nou dispositiu de localització d'avaries del relè del motor, per tal de de substituir el que ja hi havia, per raons de seguretat

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND Very few data exist on the clinical impact of permanent pacemaker implantation (PPI) after transcatheter aortic valve implantation. The objective of this study was to assess the impact of PPI after transcatheter aortic valve implantation on late outcomes in a large cohort of patients. METHODS AND RESULTS A total of 1556 consecutive patients without prior PPI undergoing transcatheter aortic valve implantation were included. Of them, 239 patients (15.4%) required a PPI within the first 30 days after transcatheter aortic valve implantation. At a mean follow-up of 22±17 months, no association was observed between the need for 30-day PPI and all-cause mortality (hazard ratio, 0.98; 95% confidence interval, 0.74-1.30; P=0.871), cardiovascular mortality (hazard ratio, 0.81; 95% confidence interval, 0.56-1.17; P=0.270), and all-cause mortality or rehospitalization for heart failure (hazard ratio, 1.00; 95% confidence interval, 0.77-1.30; P=0.980). A lower rate of unexpected (sudden or unknown) death was observed in patients with PPI (hazard ratio, 0.31; 95% confidence interval, 0.11-0.85; P=0.023). Patients with new PPI showed a poorer evolution of left ventricular ejection fraction over time (P=0.017), and new PPI was an independent predictor of left ventricular ejection fraction decrease at the 6- to 12-month follow-up (estimated coefficient, -2.26; 95% confidence interval, -4.07 to -0.44; P=0.013; R(2)=0.121). CONCLUSIONS The need for PPI was a frequent complication of transcatheter aortic valve implantation, but it was not associated with any increase in overall or cardiovascular death or rehospitalization for heart failure after a mean follow-up of ≈2 years. Indeed, 30-day PPI was a protective factor for the occurrence of unexpected (sudden or unknown) death. However, new PPI did have a negative effect on left ventricular function over time.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND: The impact of preoperative impaired left ventricular ejection fraction (EF) in octogenarians following coronary bypass surgery on short-term survival was evaluated in this study. METHODS: A total of 147 octogenarians (mean age 82.1 ± 1.9 years) with coronary artery diseases underwent elective coronary artery bypass graft between January 2000 and December 2009. Patients were stratified into: Group I (n = 59) with EF >50%, Group II (n = 59) with 50% > EF >30% and in Group III (n = 29) with 30% > EF. RESULTS: There was no difference among the three groups regarding incidence of COPD, renal failure, congestive heart failure, diabetes, and preoperative cerebrovascular events. Postoperative atrial fibrillation was the sole independent predictive factor for in-hospital mortality (odds ratio (OR), 18.1); this was 8.5% in Group I, 15.3% in Group II and 10.3% in Group III. Independent predictive factors for mortality during follow up were: decrease of EF during follow-up for more that 5% (OR, 5.2), usage of left internal mammary artery as free graft (OR, 18.1), and EF in follow-up lower than 40% (OR, 4.8). CONCLUSIONS: The results herein suggest acceptable in-hospital as well short-term mortality in octogenarians with impaired EF following coronary artery bypass grafting (CABG) and are comparable to recent literature where the mortality of younger patients was up to 15% and short-term mortality up to 40%, respectively. Accordingly, we can also state that in an octogenarian cohort with impaired EF, CABG is a viable treatment with acceptable mortality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

L´ecocardiografia per a estimar volums i funció ventricular dreta en malalts amb Tetralogia de Fallot (TF) està limitada per la importància del tracte de sortida de ventricle dret (TSVD).Objectiu: comparar diferents paràmetres ecocardiogràfics amb la RMN en malalts amb TF i IP severa. Resultats: L´excursió de l´anell tricuspidi i el valor de la ona S per Doppler tissular no es correlacionen amb la FE de VD calculada per RMN (FEVD). L´àrea fraccional a l´eix curt mostra una tendència no significativa (p=0,07) a correlacionarse amb la FEVD. Conclusions: els paràmetres ecocardiogràfics que inclouen el TSVD mostren una tendència a correlacionarse amb la FEVD, al contrari dels paràmetres de l´anell tricuspidi.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: Home blood pressure (BP) monitoring is recommended by several clinical guidelines and has been shown to be feasible in elderly persons. Wrist manometers have recently been proposed for such home BP measurement, but their accuracy has not been previously assessed in elderly patients. METHODS: Forty-eight participants (33 women and 15 men, mean age 81.3±8.0 years) had their BP measured with a wrist device with position sensor and an arm device in random order in a sitting position. RESULTS: Average BP measurements were consistently lower with the wrist than arm device for systolic BP (120.1±2.2 vs. 130.5±2.2 mmHg, P<0.001, means±SD) and diastolic BP (66.0±1.3 vs. 69.7±1.3 mmHg, P<0.001). Moreover, a 10 mmHg or greater difference between the arm and wrist device was observed in 54.2 and 18.8% of systolic and diastolic measures, respectively. CONCLUSION: Compared with the arm device, the wrist device with position sensor systematically underestimated systolic as well as diastolic BP. The magnitude of the difference is clinically significant and questions the use of the wrist device to monitor BP in elderly persons. This study points to the need to validate BP measuring devices in all age groups, including in elderly persons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: We are interested in the numerical simulation of the anastomotic region comprised between outflow canula of LVAD and the aorta. Segmenta¬tion, geometry reconstruction and grid generation from patient-specific data remain an issue because of the variable quality of DICOM images, in particular CT-scan (e.g. metallic noise of the device, non-aortic contrast phase). We pro¬pose a general framework to overcome this problem and create suitable grids for numerical simulations.Methods: Preliminary treatment of images is performed by reducing the level window and enhancing the contrast of the greyscale image using contrast-limited adaptive histogram equalization. A gradient anisotropic diffusion filter is applied to reduce the noise. Then, watershed segmentation algorithms and mathematical morphology filters allow reconstructing the patient geometry. This is done using the InsightToolKit library (www.itk.org). Finally the Vascular Model¬ing ToolKit (www.vmtk.org) and gmsh (www.geuz.org/gmsh) are used to create the meshes for the fluid (blood) and structure (arterial wall, outflow canula) and to a priori identify the boundary layers. The method is tested on five different patients with left ventricular assistance and who underwent a CT-scan exam.Results: This method produced good results in four patients. The anastomosis area is recovered and the generated grids are suitable for numerical simulations. In one patient the method failed to produce a good segmentation because of the small dimension of the aortic arch with respect to the image resolution.Conclusions: The described framework allows the use of data that could not be otherwise segmented by standard automatic segmentation tools. In particular the computational grids that have been generated are suitable for simulations that take into account fluid-structure interactions. Finally the presented method features a good reproducibility and fast application.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The paper discusses maintenance challenges of organisations with a huge number of devices and proposes the use of probabilistic models to assist monitoring and maintenance planning. The proposal assumes connectivity of instruments to report relevant features for monitoring. Also, the existence of enough historical registers with diagnosed breakdowns is required to make probabilistic models reliable and useful for predictive maintenance strategies based on them. Regular Markov models based on estimated failure and repair rates are proposed to calculate the availability of the instruments and Dynamic Bayesian Networks are proposed to model cause-effect relationships to trigger predictive maintenance services based on the influence between observed features and previously documented diagnostics