522 resultados para urethral catheterization
Resumo:
The first derivative of pressure over time (dP/dt) is a marker of left ventricular (LV) systolic function that can be assessed during cardiac catheterization and echocardiography. Radial artery dP/dt (Radial-dP/dt) has been proposed as a possible marker of LV systolic function (Nichols & O’Rourke, McDonald’s Blood Flow in Arteries) and we sought to test this hypothesis. Methods:We compared simultaneously recorded RadialdP/ dt (by high-fidelity tonometry) with LV-dP/dt (by highfidelity catheter and echocardiography parameters analogous to LV-dP/dt) in patients without aortic valve disease. In study 1, beat to beat Radial-dP/dt and LV-dP/dt were recorded at rest and during supine exercise in 12 males (aged 61±12 years) undergoing cardiac catheterization. In study 2, 2D-echocardiography and Radial-dP/dt were recorded in 59 patients (43 men; aged 64±10 years) at baseline and peak dobutamine-induced stress. Three measures at the basal septum were taken as being analogous to LV-dP/dt: (1) peak systolic strain rate, (2) strain rate (SR-dP/dt), and (3) tissue velocity during isovolumic contraction. Results: Study 1; there was a significant difference between resting LV-dP/dt (1461±383 mmHg/s) and Radial-dP/dt (1182±319 mmHg/s; P < 0.001), and a poor, but statistically significant, correlation between the variables (R2 = 0.006; P < 0.001) due to the high number of data points compared (n = 681). Similar results were observed during exercise. Study 2; there was a moderate association between baseline Radial-dP/dt and SRdP/ dt (R2 =−0.17; P < 0.01), but no significant relationship between Radial-dP/dt and all other echocardiographic measures analogous to LV-dP/dt at rest or peak stress (P > 0.05). Conclusion: The radial pressurewaveform is not a reliable marker of LV contractility.
Resumo:
Central venous catheters (CVCs) are being utilized with increasing frequency in intensive care and general medical wards. In spite of the extensive experience gained in their application, CVCs are related to the long-term risks of catheter sheath formation, infection, and thrombosis (of the catheter or vessel itself) during catheterization. Such CVC-related-complications are associated with increased morbidity, mortality, duration of hospitalization, and medical care cost [1]. The present study incorporates a novel group of Factor XIIIa (FXIIIa, plasma transglutaminase) inhibitors into a lubricious silicone elastomer in order to generate an optimized drug delivery system whereby a secondary sustained drug release profile occurs following an initial burst release for catheters and other medical devices. We propose that the incorporation of FXIIIa inhibitors into catheters, stents, and other medical implant devices would reduce the incidence of catheter sheath formation, thrombotic occlusion, and associated staphylococcal infection. This technique could be used as a local delivery system for extended release with an immediate onset of action for other poorly aqueous soluble compounds. © 2012 Elsevier B.V. All rights reserved.
Resumo:
2002 Mathematics Subject Classification: 62P10.
Resumo:
2000 Mathematics Subject Classification: 62J12, 62P10.
Resumo:
Objective Patients can experience urinary retention (UR) after Holmium laser enucleation of the prostate (HoLEP) that requires bladder distension during the procedure. The aim of this retrospective study is to identify factors affecting the UR after HoLEP. Materials and Methods 336 patients, which underwent HoLEP for a symptomatic benign prostatic hyperplasia between July 2008 and March 2012, were included in this study. Urethral catheters were routinely removed one or two days after surgery. UR was defined as the need for an indwelling catheter placement following a failure to void after catheter removal. Demographic and clinical parameters were compared between the UR (n = 37) and the non-urinary retention (non-UR; n = 299) groups. Results The mean age of patients was 68.3 (±6.5) years and the mean operative time was 75.3 (±37.4) min. Thirty seven patients (11.0%) experienced a postoperative UR. UR patients voided catheter free an average of 1.9 (±1.7) days after UR. With regard to the causes of UR, 24 (7.1%) and 13 (3.9%) patients experienced a blood clot-related UR and a non-clot related UR respectively. Using multivariate analysis (p<0.05), we found significant differences between the UR and the non-UR groups with regard to a morcellation efficiency (OR 0.701, 95% CI 0.498–0.988) and a bleeding-related complication, such as, a reoperation for bleeding (OR 0.039, 95% CI 0.004–0.383) or a transfusion (OR 0.144, 95% CI 0.027–0.877). Age, history of diabetes, prostate volume, pre-operative post-void residual, bladder contractility index, learning curve, and operative time were not significantly associated with the UR (p>0.05). Conclusions De novo UR after HoLEP was found to be self-limited and it was not related to learning curve, patient age, diabetes, or operative time. Efficient morcellation and careful control of bleeding, which reduces clot formation, decrease the risk of UR after HoLEP.
Resumo:
OBJECTIVE: To dev elop and evaluate the use of a body adjustable device for training of peripheral venous catheterization for healthcare undergraduate students . METHODS: This study involved two phases: I) development of the innovative simulator and II) a controlled trial co mparing the performance of the body adjustable device in relation to the commercial simulator for the training of venipuncture skills. A total of 79 first - year medical students participated in the intervention phase, which consisted of pretest assessment, lecture on peripheral venous access, randomization into two groups according to the simulator used for training (Commercial Simulator and Experimental Simulator), real venipuncture procedure, post - test assessment and evaluation of satisfaction. RESULTS: Gr oups were homogeneous in age, sex, pre - test and post - test scores, attitudinal assessment and performance in performing the real venipuncture. Students from the Experimental Simulator group performed better on the filling of simulated records. At the end of the study, cognitive gain significantly increased in both groups. The degree of realism perceived by students was equivalent for two groups. A total of 85.7% of students rated the Experimental Simulator as good or excellent. CONCLUSIONS: Experimental simu lator proved to be a low cost alternative for the training of venipuncture skills in upper limb. The cognitive procedural and attitudinal performances of students who used the experimental simulator were similar to those observed in the group trained with commercial simulator.
Resumo:
Background: Persons in acute care settings who have indwelling urethral catheters are at higher risk of acquiring a urinary tract infection (UTI). Other complications related to prolonged indwelling urinary catheters include decreased mobility, damage to the meatus and/or urethra, increase use of antibiotics, increased length of stay, and pain. UTIs in acute care settings account for 30 to 40% of all health care associated infections (HAIs). Of these, 80% are catheter associated UTIs (CAUTIs). Purpose: To utilized the CDC (2009) bundle approach for CAUTI prevention and create a program which supports a multimodal method to improving urinary catheter use, maintenance, and removal, including a continuing competency program where role expansion is anticipated. Methods: A comprehensive review of the literature was conducted. Physicians were consulted through a power point presentation followed by a letter explaining the project, a questionnaire, and two selections of relevant literature. Nursing staff and allied health professionals from the target units of 3A and 3B medicine attended one of two lunch and learns. They were presented the project via a power point presentation and the same questionnaire as distributed to physicians. Results: Five e-learning modules, a revised policy, and clinical pathway have been developed to support staff with best practice knowledge transfer. Conclusion: Behaviour changes need to be approached with a framework, extensive consultation, and education. Sustainability of any practice change cannot occur without having completed the background work to ensure staff have access to tools to support the change.
Resumo:
© 2015 Wiley Periodicals, Inc.
Resumo:
© 2015 Wiley Periodicals, Inc.
Resumo:
Background The quest for continuous improvement of the quality of provided care is the objective of nursing care. However, the insertion and permanence of a peripheral venous catheter has been associated to complications, thus making a systematic evaluation of the performance of professionals and the management of health services important. Objective: Analyse complications that caused removal of intravenous catheters. Methods A prospective study with 64 patients of a health service of Portugal, from July to September/2015. Included patients with age 18 years, with a peripheral venous catheter. Descriptive analysis using SPSS. Ethical requirements were met. Results Two hundred three (203) intravenous catheters, in 64 patients, most elderly (section 95.3 %), with mean age of 80 years were evaluated. The catheters remained inserted between one and 12 days (mean 2 days), 66 % of the devices were removed because of complications, such as: removal by the patient (17.7 %), obstruction (17.2 %), infiltration (14.8 %), phlebitis (9.4 %) and fluid exiting the insertion site (6.4 %). The prevalence of obstruction and infiltration per patient was respectively 36 % and 39 %. Conclusions Obstruction and infiltration were the complications of higher prevalence that led to the removal and reinsertion of a new peripheral venous catheter with the possibility of increased pain, infection and hospital costs. Faced with the risk of compromising patient safety and being able to contribute to the improvement of health care, we suggest the inclusion of obstruction and infiltration in the indicators of quality of care, in order to have systematic evaluation of results, (re)plan and implement preventive measures.
Resumo:
Background According to the Nursing Role Effectiveness Model, the structural components (nurses, patients, organizational variables) may directly BMC Health Services Research 2016, Volume 16 Suppl 3 Page 41 of 132 or indirectly influence the care outcomes through the process (actions developed by the nurses). Objectives: To identify the changes that, from the nurses' perspective, occurred during the provision of care to patients with peripheral venous catheters (PVCs) between the first and the second phase of the Action-Research (AR) study, and the components that influenced these changes. Methods During the second phase of the AR study (December, 2011), a focus group composed of six nurses was held at a medicine unit of a central hospital. A script was used with six open-ended questions. All ethical procedures were followed. Results Positive changes in nursing care provision to patients with PVCs were identified related to the type of dressing used, patient monitoring, aseptic care, and infusion rate. The nurses believed that some variables of the organizational component influenced those changes, such as the centralization of the material used for catheterization or the availability of materials, such as transparent dressings. The nurses also valued the following aspects: knowledge of the research findings of the first phase; training sessions on the topic; and, above all, the nurses' engagement throughout the process of change in care provision. Conclusions Considering the model of analysis used, we found that the changes identified in nursing care resulted from several factors, with the engagement of the professionals themselves in the change process being considered a key aspect.
Resumo:
Objectives: to report a case of hypereosinophilic syndrome which presented clinically acute coronary syndrome. Materials and methods: we describe a case of a 69-year-old woman with acute coronary syndrome and peripheral hypereosinophilia. Results: the condition rapidly evolved to severe heart failure. Coronary disease was excluded by cardiac catheterization. Systemic corticosteroid therapy was initiated and further secondary causes of hypereosinophilia were excluded.
Resumo:
Dissertação de Mestrado, Biologia Molecular e Microbiana, Faculdade de Ciências e Tecnologia, Universidade do Algarve, 2016
Resumo:
Stem cell transplantation holds great promise for the treatment of myocardial infarction injury. We recently described the embryonic stem cell-derived cardiac progenitor cells (CPCs) capable of differentiating into cardiomyocytes, vascular endothelium, and smooth muscle. In this study, we hypothesized that transplanted CPCs will preserve function of the infarcted heart by participating in both muscle replacement and neovascularization. Differentiated CPCs formed functional electromechanical junctions with cardiomyocytes in vitro and conducted action potentials over cm-scale distances. When transplanted into infarcted mouse hearts, CPCs engrafted long-term in the infarct zone and surrounding myocardium without causing teratomas or arrhythmias. The grafted cells differentiated into cross-striated cardiomyocytes forming gap junctions with the host cells, while also contributing to neovascularization. Serial echocardiography and pressure-volume catheterization demonstrated attenuated ventricular dilatation and preserved left ventricular fractional shortening, systolic and diastolic function. Our results demonstrate that CPCs can engraft, differentiate, and preserve the functional output of the infarcted heart.
Resumo:
Background: Transcatheter closure of atrial septal defects (ASD) has been accepted world-wide as an alternative to surgical closure with excellent results. This interventional, non-surgical technique plays an important role in the treatment of ASD mostly in the developing world where resources are limited. Objectives: To report the outcomes and short term follow-up of transcatheter closure of ASD over a 12-year period at our institution with limited resources. Patients and Methods: This retrospective study included all patients with the diagnosis of secundum ASD and significant shunting (Qp/Qs > 1.5:1) as well as dilated right atrium and right ventricle who had transcatheter closure at Integrated Cardiovascular Center (PJT), Dr. Cipto Mangunkusumo Hospital between October 2002 and October 2014. One hundred fifty-two patients enrolled in this study were candidates for device closure. Right and left heart cardiac catheterization was performed before the procedure. All patients underwent physical examination, ECG, chest X-ray and transthoracal echocardiography (TTE) prior to device implantation. Results: A total of 152 patients with significant ASD underwent device implantation. Subjects’ age ranged from 0.63 to 69.6 years, with median 9.36 years and mean 16.30 years. They consisted of 33 (21.7%) males and 119 (78.3%) females, with mean body weight of 29.9 kg (range 8 to 75; SD 18.2). The device was successfully implanted in 150 patients where the majority of cases received the Amplatzer septal occluder (147/150; 98%) and the others received the Heart Lifetech ASD occluder (3/150, 2%), whereas two other cases were not suitable for device closure and we decided for surgical closure. The mean ASD size was 19.75 (range 14 - 25) mm. During the procedure, 5 (4.9%) patients had bradycardia and 3 (2.9%) patients had supraventricular tachycardia (SVT), all of which resolved. Conclusions: In our center with limited facilities and manpower, transcatheter closure of atrial septal defect was effective and safe as an alternative treatment to surgery. The outcome and short-term follow-up revealed excellent results, but long-term follow-up is needed.