968 resultados para ultrasound ct


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ultrasonographic detection of subclinical atherosclerosis improves cardiovascular risk stratification, but uncertainty persists about the most discriminative method to apply. In this study, we found that the "atherosclerosis burden score (ABS)", a novel straightforward ultrasonographic score that sums the number of carotid and femoral arterial bifurcations with plaques, significantly outperformed common carotid intima-media thickness, carotid mean/maximal thickness, and carotid/femoral plaque scores for the detection of coronary artery disease (CAD) (receiver operating characteristic (ROC) curve area under the curve (AUC) = 0.79; P = 0.027 to <0.001 with the other five US endpoints) in 203 patients undergoing coronary angiography. ABS was also more correlated with CAD extension (R = 0.55; P < 0.001). Furthermore, in a second group of 1128 patients without cardiovascular disease, ABS was weakly correlated with the European Society of Cardiology chart risk categories (R (2) = 0.21), indicating that ABS provided information beyond usual cardiovascular risk factor-based risk stratification. Pending prospective studies on hard cardiovascular endpoints, ABS appears as a promising tool in primary prevention.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ranskalaisen Pierre Louis Moreau de Maupertuis'n johtama retkikunta selvitti 1736 maapallon muotoa Lapissa kolmiomittauksen avulla. Retkikunta majaili Korteniemen talossa, vaaran laella observatorio. - Digi toitu valokuvasta, joka julkaistu 1993 kirjassa Historiallisia kuvia / R. Knapas & P. Koistinen

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contexte Lié au vieillissement et à la sédentarisation de la population, ainsi qu'à la chronicisation du cancer, l'emploi de cathéters veineux centraux permanents (CVCP) n'a cessé d'augmenter. La complication majeure de ces dispositifs, induisant de forts taux de morbi-mortalité, est l'infection. Actuellement, le diagnostic de ces infections reste surtout basé sur la clinique et les hémocultures. Lorsque le doute persiste, une ablation chirurgicale suivie de la mise en culture des prélèvements chirurgicaux et du cathéter permettent de poser le diagnostic. En clinique, après ces examens, nous constatons que seule la moitié des cathéters retirés étaient réellement infectés. Alors que la tomographie par émission de positons fusionnée à la tomographie (PET/CT) a montré de bons résultats dans la détection des infections chroniques, la valeur diagnostique du PET/CT au fluorodeoxyglucose marqué au 18F (18F-FDG) pour les infections de CVCP n'a encore jamais été déterminée dans une étude prospective. Objectifs Au travers de cette étude prospective, ouverte et monocentrique, nous chercherons à connaître la valeur diagnostique du PET/CT au 18F-FDG dans la détection d'infections de CVCP et ainsi d'en déterminer son utilité. Nous essaierons aussi de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles (paramètres cliniques et culture du liquide d'aspiration), afin de se déterminer sur l'éventuelle utilité diagnostique de celui-ci. Méthodes Cadre : Etude prospective d'au moins 20 patients, avec 2 groupes contrôles d'au moins 10 patients ayant chacun respectivement une faible et une forte probabilité d'infection, soit au moins 40 patients au total. Population : patients adultes avec CVCP devant être retiré. Cette étude prévoit un examen PET/CT au 18F-FDG effectué auprès de patients nécessitant une ablation de CVCP sur suspicion d'infection, sans confirmation possible par les moyens diagnostiques non chirurgicaux. Deux acquisitions seront réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Le groupe contrôle à faible probabilité d'infection, sera formé de patients bénéficiant de l'ablation définitive d'un CVCP pour fin de traitement durant le laps de temps de l'étude, et ayant bénéficié au préalable d'un examen PET/CT pour raison X. Après avoir retiré chirurgicalement le CVCP, nous utiliserons la culture microbiologique des deux extrémités du CVCP comme étalon d'or (gold standard) de l'infection. Le groupe contrôle à forte probabilité d'infection sera formé de patients nécessitant une ablation de CVCP sur infection de CVCP confirmée par les moyens diagnostiques non chirurgicaux (culture positive du liquide de l'aspiration). Lors de l'examen PET/CT, ces patients auront aussi deux acquisitions réalisées 45 et 70 minutes après l'injection de 5,5MBq/Kg de 18F-FDG. Les résultats de ces examens seront évalués par deux spécialistes en médecine nucléaire qui détermineront le niveau de suspicion de l'infection sur une échelle de Likert allant de I à V, sur la base du nombre de foyers, de la localisation du foyer, de l'intensité de la captation de 18F-FDG au voisinage du cathéter et du rapport tissu/arrière-plan. Par la suite, nous retirerons chirurgicalement le CVCP. Nous utiliserons la culture microbiologique du pus (si présent), des deux extrémités du CVCP ainsi que l'histologie des tissus formant un tunnel autour du cathéter comme étalon d'or de l'infection. Les résultats seront analysés à l'aide de courbes ROC (Receiver Operating Characteristic) afin de déterminer la valeur diagnostique du PET/CT dans l'infection de CVCP. Les résultats des examens des patients avec suspicion clinique d'infection seront ensuite analysés séparément, afin de déterminer la différence de valeur diagnostique du PET/CT au 18F-FDG par rapport aux méthodes conventionnelles. Résultats escomptés Ce projet veut chercher à savoir si le PET/CT au 18F-FDG peut être un moyen diagnostique valide dans les infections de CVCP, s'avérer utile lorsque les autres moyens diagnostiques sont non conclusifs. Plus-value escomptée Actuellement, lors d'incertitude sur le diagnostic d'infection de CVCP, une opération chirurgicale est effectuée à titre préventif afin d'enlever le cathéter en cause, cependant seulement la moitié de ces cathéters sont réellement infectés en pratique. Le PET/CT au 18F-FDG, grâce à sa sensibilité élevée et probablement une bonne valeur prédictive négative, pourrait éviter à une partie des patients un retrait inutile du cathéter, diminuant ainsi les risques chirurgicaux et les coûts liés à de telles opérations, tout en préservant le capital d'accès vasculaire futur.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to compare multidetector CT (MDCT), MRI, and FDG PET/CT imaging for the detection of peritoneal carcinomatosis (PC) in ovarian cancer. PATIENTS AND METHODS: Fifteen women with ovarian cancer and suspected PC underwent MDCT, MRI, and FDG PET/CT, shortly before surgery. Nine abdominopelvic regions were defined according to the peritoneal cancer index. We applied lesion size scores on MDCT and MR and measured FDG PET/CT standard uptake. We blindly read MDCT, MR, and PET/CT before joint review and comparison with histopathology. Receiver operating characteristics analysis was performed. RESULTS: Ten women had PC (67%). Altogether, 135 abdominopelvic sites were compared. Multidetector CT, MRI, and FDG PET/CT had a sensitivity of 96%, 98%, and 95%, and specificity was 92%, 84%, and 96%, respectively. Corresponding receiver operating characteristics area was 0.94, 0.90, and 0.96, respectively, without any significant differences between them (P = 0.12). FDG PET/CT detected supradiaphragmatic disease in 3 women (20%) not seen by MDCT or MRI. CONCLUSIONS: Although MRI had the highest sensitivity and FDG PET/CT had the highest specificity, no significant differences were found between the 3 techniques. Thus, MDCT, as the fastest, most economical, and most widely available modality, is the examination of choice, if a stand-alone technique is required. If inconclusive, PET/CT or MRI may offer additional insights. Whole-body FDG PET/CT may be more accurate for supradiaphragmatic metastatic extension.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Endorectal ultrasonography has become the preferred exam to assess the local extent of rectal cancers. From 1990 to 1992, we have examined 28 patients with a rectal cancer. The tumours were classified according to the TNM. The objective of this exam is to identify patients whose tumours have invaded the perirectal fat. These patients are first treated in our clinic by an accelerated hyperfractionated radiotherapy and then operated. The preoperative staging made with the endorectal ultrasound was then compared with the anatomopathologic staging. The depth of the invasion was assessed precisely in 78.5% of cases. The exam's sensitivity to detect the invasion of the perirectal fat was 96% and its specificity 75%. Lymph node involvement was accurately identified in 67.8% of cases with a sensitivity of 81% and a specificity of 50%. This short retrospective study confirms that endorectal ultrasonography is a highly accurate tool for the staging of rectal carcinoma prior to operation and hence to select the patients that can benefit from preoperative irradiation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

BACKGROUND AND PURPOSE: The posterior circulation Acute Stroke Prognosis Early CT Score (pc-APECTS) applied to CT angiography source images (CTA-SI) predicts the functional outcome of patients in the Basilar Artery International Cooperation Study (BASICS). We assessed the diagnostic and prognostic impact of pc-ASPECTS applied to perfusion CT (CTP) in the BASICS registry population. METHODS: We applied pc-ASPECTS to CTA-SI and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) parameter maps of BASICS patients with CTA and CTP studies performed. Hypoattenuation on CTA-SI, relative reduction in CBV or CBF, or relative increase in MTT were rated as abnormal. RESULTS: CTA and CTP were available in 27/592 BASICS patients (4.6%). The proportion of patients with any perfusion abnormality was highest for MTT (93%; 95% confidence interval [CI], 76%-99%), compared with 78% (58%-91%) for CTA-SI and CBF, and 46% (27%-67%) for CBV (P < .001). All 3 patients with a CBV pc-ASPECTS < 8 compared to 6/23 patients with a CBV pc-ASPECTS ≥ 8 had died at 1 month (RR 3.8; 95% CI, 1.9-7.6). CONCLUSION: CTP was performed in a minority of the BASICS registry population. Perfusion disturbances in the posterior circulation were most pronounced on MTT parameter maps. CBV pc-ASPECTS < 8 may indicate patients with high case fatality.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Perfusion-CT (PCT) processing involves deconvolution, a mathematical operation that computes the perfusion parameters from the PCT time density curves and an arterial curve. Delay-sensitive deconvolution does not correct for arrival delay of contrast, whereas delay-insensitive deconvolution does. The goal of this study was to compare delay-sensitive and delay-insensitive deconvolution PCT in terms of delineation of the ischemic core and penumbra. METHODS: We retrospectively identified 100 patients with acute ischemic stroke who underwent admission PCT and CT angiography (CTA), a follow-up vascular study to determine recanalization status, and a follow-up noncontrast head CT (NCT) or MRI to calculate final infarct volume. PCT datasets were processed twice, once using delay-sensitive deconvolution and once using delay-insensitive deconvolution. Regions of interest (ROIs) were drawn, and cerebral blood flow (CBF), cerebral blood volume (CBV), and mean transit time (MTT) in these ROIs were recorded and compared. Volume and geographic distribution of ischemic core and penumbra using both deconvolution methods were also recorded and compared. RESULTS: MTT and CBF values are affected by the deconvolution method used (p < 0.05), while CBV values remain unchanged. Optimal thresholds to delineate ischemic core and penumbra are different for delay-sensitive (145 % MTT, CBV 2 ml × 100 g(-1) × min(-1)) and delay-insensitive deconvolution (135 % MTT, CBV 2 ml × 100 g(-1) × min(-1) for delay-insensitive deconvolution). When applying these different thresholds, however, the predicted ischemic core (p = 0.366) and penumbra (p = 0.405) were similar with both methods. CONCLUSION: Both delay-sensitive and delay-insensitive deconvolution methods are appropriate for PCT processing in acute ischemic stroke patients. The predicted ischemic core and penumbra are similar with both methods when using different sets of thresholds, specific for each deconvolution method.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: Atheromatic plaque progression is affected, among others phenomena, by biomechanical, biochemical, and physiological factors. In this paper, the authors introduce a novel framework able to provide both morphological (vessel radius, plaque thickness, and type) and biomechanical (wall shear stress and Von Mises stress) indices of coronary arteries. Methods: First, the approach reconstructs the three-dimensional morphology of the vessel from intravascular ultrasound(IVUS) and Angiographic sequences, requiring minimal user interaction. Then, a computational pipeline allows to automatically assess fluid-dynamic and mechanical indices. Ten coronary arteries are analyzed illustrating the capabilities of the tool and confirming previous technical and clinical observations. Results: The relations between the arterial indices obtained by IVUS measurement and simulations have been quantitatively analyzed along the whole surface of the artery, extending the analysis of the coronary arteries shown in previous state of the art studies. Additionally, for the first time in the literature, the framework allows the computation of the membrane stresses using a simplified mechanical model of the arterial wall. Conclusions: Circumferentially (within a given frame), statistical analysis shows an inverse relation between the wall shear stress and the plaque thickness. At the global level (comparing a frame within the entire vessel), it is observed that heavy plaque accumulations are in general calcified and are located in the areas of the vessel having high wall shear stress. Finally, in their experiments the inverse proportionality between fluid and structural stresses is observed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

CONTEXT: The current standard for diagnosing prostate cancer in men at risk relies on a transrectal ultrasound-guided biopsy test that is blind to the location of the cancer. To increase the accuracy of this diagnostic pathway, a software-based magnetic resonance imaging-ultrasound (MRI-US) fusion targeted biopsy approach has been proposed. OBJECTIVE: Our main objective was to compare the detection rate of clinically significant prostate cancer with software-based MRI-US fusion targeted biopsy against standard biopsy. The two strategies were also compared in terms of detection of all cancers, sampling utility and efficiency, and rate of serious adverse events. The outcomes of different targeted approaches were also compared. EVIDENCE ACQUISITION: We performed a systematic review of PubMed/Medline, Embase (via Ovid), and Cochrane Review databases in December 2013 following the Preferred Reported Items for Systematic reviews and Meta-analysis statement. The risk of bias was evaluated using the Quality Assessment of Diagnostic Accuracy Studies-2 tool. EVIDENCE SYNTHESIS: Fourteen papers reporting the outcomes of 15 studies (n=2293; range: 13-582) were included. We found that MRI-US fusion targeted biopsies detect more clinically significant cancers (median: 33.3% vs 23.6%; range: 13.2-50% vs 4.8-52%) using fewer cores (median: 9.2 vs 37.1) compared with standard biopsy techniques, respectively. Some studies showed a lower detection rate of all cancer (median: 50.5% vs 43.4%; range: 23.7-82.1% vs 14.3-59%). MRI-US fusion targeted biopsy was able to detect some clinically significant cancers that would have been missed by using only standard biopsy (median: 9.1%; range: 5-16.2%). It was not possible to determine which of the two biopsy approaches led most to serious adverse events because standard and targeted biopsies were performed in the same session. Software-based MRI-US fusion targeted biopsy detected more clinically significant disease than visual targeted biopsy in the only study reporting on this outcome (20.3% vs 15.1%). CONCLUSIONS: Software-based MRI-US fusion targeted biopsy seems to detect more clinically significant cancers deploying fewer cores than standard biopsy. Because there was significant study heterogeneity in patient inclusion, definition of significant cancer, and the protocol used to conduct the standard biopsy, these findings need to be confirmed by further large multicentre validating studies. PATIENT SUMMARY: We compared the ability of standard biopsy to diagnose prostate cancer against a novel approach using software to overlay the images from magnetic resonance imaging and ultrasound to guide biopsies towards the suspicious areas of the prostate. We found consistent findings showing the superiority of this novel targeted approach, although further high-quality evidence is needed to change current practice.