933 resultados para transverse stochastic cooling
Resumo:
The demand for cooling and air-conditioning of building is increasingly ever growing. This increase is mostly due to population and economic growth in developing countries, and also desire for a higher quality of thermal comfort. Increase in the use of conventional cooling systems results in larger carbon footprint and more greenhouse gases considering their higher electricity consumption, and it occasionally creates peaks in electricity demand from power supply grid. Solar energy as a renewable energy source is an alternative to drive the cooling machines since the cooling load is generally high when solar radiation is high. This thesis examines the performance of PV/T solar collector manufactured by Solarus company in a solar cooling system for an office building in Dubai, New Delhi, Los Angeles and Cape Town. The study is carried out by analyzing climate data and the requirements for thermal comfort in office buildings. Cooling systems strongly depend on weather conditions and local climate. Cooling load of buildings depend on many parameters such as ambient temperature, indoor comfort temperature, solar gain to the building and internal gains including; number of occupant and electrical devices. The simulations were carried out by selecting a suitable thermally driven chiller and modeling it with PV/T solar collector in Polysun software. Fractional primary energy saving and solar fraction were introduced as key figures of the project to evaluate the performance of cooling system. Several parametric studies and simulations were determined according to PV/T aperture area and hot water storage tank volume. The fractional primary energy saving analysis revealed that thermally driven chillers, particularly adsorption chillers are not suitable to be utilizing in small size of solar cooling systems in hot and tropic climates such as Dubai and New Delhi. Adsorption chillers require more thermal energy to meet the cooling load in hot and dry climates. The adsorption chillers operate in their full capacity and in higher coefficient of performance when they run in a moderate climate since they can properly reject the exhaust heat. The simulation results also indicated that PV/T solar collector have higher efficiency in warmer climates, however it requires a larger size of PV/T collectors to supply the thermally driven chillers for providing cooling in hot climates. Therefore using an electrical chiller as backup gives much better results in terms of primary energy savings, since PV/T electrical production also can be used for backup electrical chiller in a net metering mechanism.
Demonstration of Solar Heating and Cooling System using Sorption Integrated Solar Thermal Collectors
Resumo:
Producing cost-competitive small and medium-sized solar cooling systems is currently a significant challenge. Due to system complexity, extensive engineering, design and equipment costs; the installation costs of solar thermal cooling systems are prohibitively high. In efforts to overcome these limitations, a novel sorption heat pump module has been developed and directly integrated into a solar thermal collector. The module comprises a fully encapsulated sorption tube containing hygroscopic salt sorbent and water as a refrigerant, sealed under vacuum with no moving parts. A 5.6m2 aperture area outdoor laboratory-scale system of sorption module integrated solar collectors was installed in Stockholm, Sweden and evaluated under constant re-cooling and chilled fluid return temperatures in order to assess collector performance. Measured average solar cooling COP was 0.19 with average cooling powers between 120 and 200 Wm-2 collector aperture area. It was observed that average collector cooling power is constant at daily insolation levels above 3.6 kWhm-2 with the cooling energy produced being proportional to solar insolation. For full evaluation of an integrated sorption collector solar heating and cooling system, under the umbrella of a European Union project for technological innovation, a 180 m2 large-scale demonstration system has been installed in Karlstad, Sweden. Results from the installation commissioned in summer 2014 with non-optimised control strategies showed average electrical COP of 10.6 and average cooling powers between 140 and 250 Wm-2 collector aperture area. Optimisation of control strategies, heat transfer fluid flows through the collectors and electrical COP will be carried out in autumn 2014.
Resumo:
Exploiting solar energy technology for both heating and cooling purposes has the potential of meeting an appreciable portion of the energy demand in buildings throughout the year. By developing an integrated, multi-purpose solar energy system, that can operate all twelve months of the year, a high utilisation factor can be achieved which translates to more economical systems. However, there are still some techno-economic barriers to the general commercialisation and market penetration of such technologies. These are associated with high system and installation costs, significant system complexity, and lack of knowledge of system implementation and expected performance. A sorption heat pump module that can be integrated directly into a solar thermal collector has thus been developed in order to tackle the aforementioned market barriers. This has been designed for the development of cost-effective pre-engineered solar energy system kits that can provide both heating and cooling. This thesis summarises the characterisation studies of the operation of individual sorption modules, sorption module integrated solar collectors and a full solar heating and cooling system employing sorption module integrated collectors. Key performance indicators for the individual sorption modules showed cooling delivery for 6 hours at an average power of 40 W and a temperature lift of 21°C. Upon integration of the sorption modules into a solar collector, measured solar radiation energy to cooling energy conversion efficiencies (solar cooling COP) were between 0.10 and 0.25 with average cooling powers between 90 and 200 W/m2 collector aperture area. Further investigations of the sorption module integrated collectors implementation in a full solar heating and cooling system yielded electrical cooling COP ranging from 1.7 to 12.6 with an average of 10.6 for the test period. Additionally, simulations were performed to determine system energy and cost saving potential for various system sizes over a full year of operation for a 140 m2 single-family dwelling located in Madrid, Spain. Simulations yielded an annual solar fraction of 42% and potential cost savings of €386 per annum for a solar heating and cooling installation employing 20m2 of sorption integrated collectors.
Resumo:
The regimen of environmental flows (EF) must be included as terms of environmental demand in the management of water resources. Even though there are numerous methods for the computation of EF, the criteria applied at different steps in the calculation process are quite subjective whereas the results are fixed values that must be meet by water planners. This study presents a friendly-user tool for the assessment of the probability of compliance of a certain EF scenario with the natural regimen in a semiarid area in southern Spain. 250 replications of a 25-yr period of different hydrological variables (rainfall, minimum and maximum flows, ...) were obtained at the study site from the combination of Monte Carlo technique and local hydrological relationships. Several assumptions are made such as the independence of annual rainfall from year to year and the variability of occurrence of the meteorological agents, mainly precipitation as the main source of uncertainty. Inputs to the tool are easily selected from a first menu and comprise measured rainfall data, EF values and the hydrological relationships for at least a 20-yr period. The outputs are the probabilities of compliance of the different components of the EF for the study period. From this, local optimization can be applied to establish EF components with a certain level of compliance in the study period. Different options for graphic output and analysis of results are included in terms of graphs and tables in several formats. This methodology turned out to be a useful tool for the implementation of an uncertainty analysis within the scope of environmental flows in water management and allowed the simulation of the impacts of several water resource development scenarios in the study site.
Resumo:
Using the Pricing Equation in a panel-data framework, we construct a novel consistent estimator of the stochastic discount factor (SDF) which relies on the fact that its logarithm is the serial-correlation ìcommon featureîin every asset return of the economy. Our estimator is a simple function of asset returns, does not depend on any parametric function representing preferences, is suitable for testing di§erent preference speciÖcations or investigating intertemporal substitution puzzles, and can be a basis to construct an estimator of the risk-free rate. For post-war data, our estimator is close to unity most of the time, yielding an average annual real discount rate of 2.46%. In formal testing, we cannot reject standard preference speciÖcations used in the literature and estimates of the relative risk-aversion coe¢ cient are between 1 and 2, and statistically equal to unity. Using our SDF estimator, we found little signs of the equity-premium puzzle for the U.S.
Resumo:
Using the Pricing Equation, in a panel-data framework, we construct a novel consistent estimator of the stochastic discount factor (SDF) mimicking portfolio which relies on the fact that its logarithm is the ìcommon featureîin every asset return of the economy. Our estimator is a simple function of asset returns and does not depend on any parametric function representing preferences, making it suitable for testing di§erent preference speciÖcations or investigating intertemporal substitution puzzles.
Resumo:
This Paper Tackles the Problem of Aggregate Tfp Measurement Using Stochastic Frontier Analysis (Sfa). Data From Penn World Table 6.1 are Used to Estimate a World Production Frontier For a Sample of 75 Countries Over a Long Period (1950-2000) Taking Advantage of the Model Offered By Battese and Coelli (1992). We Also Apply the Decomposition of Tfp Suggested By Bauer (1990) and Kumbhakar (2000) to a Smaller Sample of 36 Countries Over the Period 1970-2000 in Order to Evaluate the Effects of Changes in Efficiency (Technical and Allocative), Scale Effects and Technical Change. This Allows Us to Analyze the Role of Productivity and Its Components in Economic Growth of Developed and Developing Nations in Addition to the Importance of Factor Accumulation. Although not Much Explored in the Study of Economic Growth, Frontier Techniques Seem to Be of Particular Interest For That Purpose Since the Separation of Efficiency Effects and Technical Change Has a Direct Interpretation in Terms of the Catch-Up Debate. The Estimated Technical Efficiency Scores Reveal the Efficiency of Nations in the Production of Non Tradable Goods Since the Gdp Series Used is Ppp-Adjusted. We Also Provide a Second Set of Efficiency Scores Corrected in Order to Reveal Efficiency in the Production of Tradable Goods and Rank Them. When Compared to the Rankings of Productivity Indexes Offered By Non-Frontier Studies of Hall and Jones (1996) and Islam (1995) Our Ranking Shows a Somewhat More Intuitive Order of Countries. Rankings of the Technical Change and Scale Effects Components of Tfp Change are Also Very Intuitive. We Also Show That Productivity is Responsible For Virtually All the Differences of Performance Between Developed and Developing Countries in Terms of Rates of Growth of Income Per Worker. More Important, We Find That Changes in Allocative Efficiency Play a Crucial Role in Explaining Differences in the Productivity of Developed and Developing Nations, Even Larger Than the One Played By the Technology Gap
Resumo:
A finalidade deste trabalho ´e apresentar uma revis˜ao da teoria do transporte de part´ıculas em meios compostos por uma mistura aleat´oria bin´aria. Para atingir este objetivo n´os apresentamos brevemente alguns conceitos b´asicos de teoria do transporte, e ent˜ao discutimos em detalhes a deriva¸c˜ao de duas abordagens desenvolvidas para a solu¸c˜ao de tais problemas: os modelos de mistura atˆomica e de Levermore-Pomraning. Providenciamos ainda, com o uso da formula¸c˜ao LTSN, compara ¸c˜oes num´ericas destes modelos com resultados de benchmark gerados atrav´es de um processo de Monte Carlo.