959 resultados para subdavian vein
Resumo:
OBJECTIVE: To study the arrangement of the myocardial fiber bundles at the pulmonary venous left atrial junction in patients with pulmonary hypertension, and to discuss the pathophysiological importance of this element in the etiology of acute pulmonary edema. METHODS: We obtained 12 hearts and their pulmonary vein extremities from postmortem examinations of patients with the anatomicopathological diagnosis of acute pulmonary edema. The specimens, which had no grossly visible morphological cardiac alterations, were fixed in 10% formalin, and the muscular arrangement of the pulmonary venous left atrial junctions was analyzed. This material was then isolated, embedded in paraffin, underwent serial cutting (50 µm of thickness), and was stained with Azam's trichrome. RESULTS: We observed in our specimens that: a) the myocardial fiber bundles that originate in the atrial wall and involve the openings of the pulmonary veins were fewer than those observed in healthy material; b) the myocardial fiber bundles that extend into the pulmonary veins were shorter than those found in material originating from individuals with no pulmonary hypertension. CONCLUSION: Anatomical changes that result in a reduction in the amount of myocardial fiber bundles in the pulmonary venous left atrial junction, isolated or associated with other factors, may be the cause of disorders in pulmonary circulation, leading to an increase in pulmonary venous pressure, and, consequently, to acute pulmonary edema.
Resumo:
OBJECTIVE: To demonstrate the feasibility and safety of simultaneous catheterization and mapping of the 4 pulmonary veins for ablation of atrial fibrillation. METHODS: Ten patients, 8 with paroxysmal atrial fibrillation and 2 with persistent atrial fibrillation, refractory to at least 2 antiarrhythmic drugs and without structural cardiopathy, were consecutively studied. Through the transseptal insertion of 2 long sheaths, 4 pulmonary veins were simultaneously catheterized with octapolar microcatheters. After identification of arrhythmogenic foci radiofrequency was applied under angiographic or ultrasonographic control. RESULTS: During 17 procedures, 40 pulmonary veins were mapped, 16 of which had local ectopic activity, related or not with the triggering of atrial fibrillation paroxysms. At the end of each procedure, suppression of arrhythmias was obtained in 8 patients, and elimination of pulmonary vein potentials was accomplished in 4. During the clinical follow-up of 9.6±3 months, 7 patients remained in sinus rhythm, 5 of whom were using antiarrhythmic drugs that had previously been ineffective. None of the patients had pulmonary hypertension or evidence of stenosis in the pulmonary veins. CONCLUSION: Selective and simultaneous catheterization of the 4 pulmonary veins with microcatheters for simultaneous recording of their electrical activity is a feasible and safe procedure that may help ablation of atrial fibrillation.
Resumo:
OBJECTIVE: To identify useful clinical characteristics for selecting patients eligible for mapping and ablation of atrial fibrillation. METHODS: We studied 9 patients with atrial fibrillation, without structural heart disease, associated with: 1) antiarrhythmic drugs, 2) symptoms of low cardiac output, and 3) intention to treat. Seven patients had paroxysmal atrial fibrillation and 2 had recurrent atrial fibrillation. RESULTS: In the 6 patients who underwent mapping (all had paroxysmal atrial fibrillation), catheter ablation was successfully carried out in superior pulmonary veins in 5 patients (the first 3 in the left superior pulmonary vein and the last 2 in the right superior pulmonary vein). One patient experienced a recurrence of atrial fibrillation after 10 days. We observed that patients who had short episodes of atrial fibrillation on 24-hour Holter monitoring before the procedure were those in whom mapping the focus of tachycardia was possible. Tachycardia was successfully suppressed in 4 of 6 patients. The cause of failure was due to the impossibility of maintaining sinus rhythm long enough for efficient mapping. CONCLUSION: Patients experiencing short episodes of atrial fibrillation during 24-hour Holter monitoring were the most eligible for mapping and ablation, with a final success rate of 66%, versus the global success rate of 44%. Patients with persistent atrial fibrillation were not good candidates for focal ablation.
Resumo:
The case of a 16-year-old patient with atrioventricular tachycardia caused by a single left anterolateral accessory pathway is reported. When the patient underwent radiofrequency ablation, a lesion on the mitral annulus lateral wall produced changes in the retrograde atrial activation pattern determined by that pathway; changes ranged from a delay in depolarization of the annulus posterior portions to full left atrium counterclockwise activation. Such phenomena were probably caused by a block in the isthmus between the annulus and the lower left pulmonary vein ostium. This case illustrates the importance of the mitral-pulmonary isthmus in the process of left atrium activation, an alert to changes induced by its unintentional block during accessory pathway ablation.
Resumo:
OBJECTIVE: To identify the left inferior pulmonary vein as an indirect marker of increased pulmonary flow in congenital heart diseases.METHODS: We carried out a prospective consecutive study on 40 patients divided into 2 groups as follows: G1 - 20 patients diagnosed with congenital heart disease and increased pulmonary flow; G2 (control group) - 20 patients who were either healthy or had congenital heart disease with decreased or normal pulmonary flow. We obtained the velocity-time integral of the left inferior pulmonary vein flow, excluding the "reverse A" wave, with pulsed Doppler echocardiography.RESULTS: In G1, 19 out of the 20 patients had well-identified dilation of the left inferior pulmonary vein. No G2 patient had dilation of the left inferior pulmonary vein. Dilation of the left inferior pulmonary vein in conditions of increased pulmonary flow had sensitivity of 95%, specificity of 100%, positive predictive value of 100%, and negative predictive value of 95% (1 false-negative case). The integral of time and velocity of the pulmonary venous flow obtained with pulsed Doppler echocardiography was greater in the G1 patients (G1=25.0±4.6 cm versus G2=14.8±2.1 cm, p=0.0001).CONCLUSION: The identification of dilation of the left inferior pulmonary vein suggests the presence of congenital heart disease with increased pulmonary flow. This may be used as an indirect sign of increased flow, mainly in malformations of difficult diagnosis, such as atrial septal defects of the venous sinus or coronary sinus type.
Resumo:
Background:Heart failure and atrial fibrillation (AF) often coexist in a deleterious cycle.Objective:To evaluate the clinical and echocardiographic outcomes of patients with ventricular systolic dysfunction and AF treated with radiofrequency (RF) ablation.Methods:Patients with ventricular systolic dysfunction [ejection fraction (EF) <50%] and AF refractory to drug therapy underwent stepwise RF ablation in the same session with pulmonary vein isolation, ablation of AF nests and of residual atrial tachycardia, named "background tachycardia". Clinical (NYHA functional class) and echocardiographic (EF, left atrial diameter) data were compared (McNemar test and t test) before and after ablation.Results:31 patients (6 women, 25 men), aged 37 to 77 years (mean, 59.8±10.6), underwent RF ablation. The etiology was mainly idiopathic (19 p, 61%). During a mean follow-up of 20.3±17 months, 24 patients (77%) were in sinus rhythm, 11 (35%) being on amiodarone. Eight patients (26%) underwent more than one procedure (6 underwent 2 procedures, and 2 underwent 3 procedures). Significant NYHA functional class improvement was observed (pre-ablation: 2.23±0.56; postablation: 1.13±0.35; p<0.0001). The echocardiographic outcome also showed significant ventricular function improvement (EF pre: 44.68%±6.02%, post: 59%±13.2%, p=0.0005) and a significant left atrial diameter reduction (pre: 46.61±7.3 mm; post: 43.59±6.6 mm; p=0.026). No major complications occurred.Conclusion:Our findings suggest that AF ablation in patients with ventricular systolic dysfunction is a safe and highly effective procedure. Arrhythmia control has a great impact on ventricular function recovery and functional class improvement.
Resumo:
Background: Nitric oxide (NO) has been largely associated with cardiovascular protection through improvement of endothelial function. Recently, new evidence about modulation of NO release by microRNAs (miRs) has been reported, which could be involved with statin-dependent pleiotropic effects, including anti-inflammatory properties related to vascular endothelium function. Objective: To evaluate the effects of cholesterol-lowering drugs including the inhibitors of cholesterol synthesis, atorvastatin and simvastatin, and the inhibitor of cholesterol absorption ezetimibe on NO release, NOS3 mRNA expression and miRs potentially involved in NO bioavailability. Methods: Human umbilical vein endothelial cells (HUVEC) were exposed to atorvastatin, simvastatin or ezetimibe (0 to 5.0 μM). Cells were submitted to total RNA extraction and relative quantification of NOS3 mRNA and miRs -221, -222 and -1303 by qPCR. NO release was measured in supernatants by ozone-chemiluminescence. Results: Both statins increased NO levels and NOS3 mRNA expression but no influence was observed for ezetimibe treatment. Atorvastatin, simvastatin and ezetimibe down-regulated the expression of miR-221, whereas miR-222 was reduced only after the atorvastatin treatment. The magnitude of the reduction of miR-221 and miR-222 after treatment with statins correlated with the increment in NOS3 mRNA levels. No influence was observed on the miR-1303 expression after treatments. Conclusion: NO release in endothelial cells is increased by statins but not by the inhibitor of cholesterol absorption, ezetimibe. Our results provide new evidence about the participation of regulatory miRs 221/222 on NO release induction mediated by statins. Although ezetimibe did not modulate NO levels, the down-regulation of miR-221 could involve potential effects on endothelial function.
Resumo:
In this paper the A. A. report the observations about the general anesthesia by chloral hydrate on the veterinary surgery. The observations were made on emasculation practices of horses, mules and hogs. It was possible to establish the following conclusions: 1) The choral hydrate presents low cost, it harmless, and is of easy application. 2) The more recommendable dosis for equine and swine were : 12-13 g per 100 k of body weight, in destilled water solution at 30 and 20%, respectively. 3) The anaethestic was injected by intravenous way with good results; in horses and mules the applications were made in the jugular; in swine, in the anterior vena cava, as was described by Carle and Dewhirst, because it was impracticable in the ear vein. 4) The dosis applied produced deep narcosis not lasting to long and with no danger to the animal's life. 5) In the case of fattening hogs, it must be made a discount of about 40% on the body weight, to calculate dosis to be employed. 6) The tables A and B show the results, that may be considered as good.
Resumo:
The liver is an organ notable for its sensitivity to a great variety of environmental factors. It is composed of a parenchyma divided into irregular lobules by the exocrine pancreas or hepatopancreas; the pancreatic cells are arranged around a branch of the portal vein. The hepatocytes are radially arranged in cords around a central sinusoid. The liver histomorphology and the organization of exocrine pancreatic tissue of O. jenynsii (Günther, 1864) is similar to the acinar morphology of many teleosts, including freshwater and marine species. The aim of the present work was to carry out the histological analysis of the liver of Oligosarcus jenynsii, one of the most common species inhabiting Los Padres Lake (Buenos Aires Province, Argentina).
Resumo:
Nous avons travaillé à Bello Horizonte, Etat de Minas, avec le venin de 4 espèces de Scorpions: Tityus bahiensis (C. L. KOCK, 1836). Tityus serrulatus (LUTZ-MELLO, 1922). Tityus dorsomaculatus (LUTZ MELLO, 1922). Bothriurus (espèce em étude), sur un total de 13.640 individus. Nous avons essayé et observe laction du venin sur 97 espèces differentes dêtres vivants depuis les chlamydozoaires jusquà l«Homo sapiens». Nous avons cherché à déterminer une unité toxique «plus précise, plus régulierè». Les étalons dits «unité vésicule», «unité morsure» sont inconstants et sans rigueur. Tout au plus, peuvent ils server à létude de laction générale du venin, et cela meme, dans certains cas seulement. Nous avons employé la pesée pour determiner lunité toxique. Ce qui est important pour qui étudie ces sujets ce nest pás lê nombre de vésicules, mais bien la quantité de venin humide ou desséché quelles contiennent. La balance, pour notre travail, est um moyen indicateur de bien plus grande précision que la «vésicule» ou la «morsure». Nous sommes parvenus à prouver quil existe une relation constante entre le poid brut des vésicules et la quantité de venin humide ou desséché quelles contiennent dans leur intérieur. Donc em pesant les vésicules, nous pesons indirectement le venin. Peu nous importe quil y ait 10 ou 100 vésicules. Il nous importe seulement de savoir combien elles pèsent, et de déterminer par ce fait, la quantité proportionnelle de vain pur. La technique générale est la suivante: Nous pesons um certain nombre de vésicules. Nous triturons ensuite, dans um mortier stérilisé et nous emulsionnons, par laddition consécutive deau distillée, stérilisée. Nous filtrons lémulsion sur le papier filtre employé em chimie, préalablement taré et desséché dans une atmosphere de chlorure de calcium. Après le filtrage on sèche à nouveau les papiers filtre employés d'abord à l'étuve et ensuite dans la même atmosphère de chlorure de calcium. Nous pesons plusieurs fois et on obtient la moyenne de ces pesées. On soustrait de cette dernière pesée le taux des substances non venimeuses, glandulaires, également dissoutes et calculées à 23 du poids brut et celles retenues par les papiers,-on obtient ainsi la moyenne réelle du venin pur contenu dans les vésicules utilisèés. Une simple divisiôn suffit pour fixer la moyenne de chacune. Ces données ont été vérifiées par les expériences faites avec du venin pur, largement obtenu dans notre Laboratoire. Nous avons trouvé de la sorte pour une vésicule de Tityus serrulatus: 0,gr.000,386 de T. bahiensis: 0,gr.001.261.24 de venin pur ce qui donne. 7/15,96 pour la 1ère. 1/8,36 pour la 2ème du poids sec de chaque vésicule. Le poids sec, pour une moyenne obtenue de 1.000 vésicules, fut de 0,gr.008,236 pour Tityus bahiensis. Maximum 0,gr.011. Minimum 0,gr.004.4 pour chacun. Pour Tityus serrulatus, en 1.049 vésicules le poids fut de 0,gr.006,08. Maximum 0,gr.014.03. Minimum 0,gr.003,1 pour chacun. C'est pour cette raison que l'unité-vésicule est incertaine. 2 poules A et B.; l'une, A, pesant 2 K.030 gr. reçoit dans une veinè, une émulsion en sèrum physiologique à 8,50/%, stérilisé, de 19 vésicules totales de Tityus serrulatus, et présence de légers phénomènes toxiques. L'autre, B, pesant 2 K.320 gr. meurt avec tous les phénomènes classiques de l'empoisonnement, par l'injection endoveineuse del'émulsion de 16 vésicules totales de venin de Tityus serrulatus! Les premières 19 vésicules pesaient 0,gr.58; les 16 derniéres-84 milligrammes. Les premières contenaient 0,gr.003. 634 et les secondes 0,gr.005.263 de venin pur! La moyenne obtenue de 6346 scorpions, (entre T. bahiensis et T. serrulatus) nous a fourni pour chacun: 0,gr.000,131,53 de venin pur, par piqûre. Si l'on spécifie: Pour 5.197 T. bahiensis. La moyenne pour une piqûre est 0,gr.000.106.15. Pour 1.149 T. serrulatus, la moyenne pour une piqûre est.......0,gr.000.246.30. La quantité a varié, selon les individus, de 0,gr.000.035.71, à 0,gr.000.436.01 de venin pur, pour une piqûre. D'après ce qui vient d'étre dit, on peut voir combien la quantité de venin éjaculé varie, chaque fois, chez les scorpions. L'unité-piqûre ne peut done pas ètre utiliseé pour des expériences dèlicates. Le mieux est de se servir de venin pur, et c'est ce que nous avons fait pour les expériences minutieuses. Quand on n'en possède pas, on peut établir pour chaque série des expériences à tenter-la dose minima mortelle en poids (grammes et fractions) de vésicules. D'après les bases ici consignées, et avec une trés petite erreur, on peut calculer la quantité de venin pur de cette dóse. Ce calcul est d'ailleurs dispensable. On peut s'en rapporter simplement au poids sec des vésicules totales et dire que la D. m. m. est de tant de milligr. secs. Comme le venin se conserve mal dans les vésicules, il faut, dans ce procédé, doser la D. m. m. toutes les fois que l'on veut procéder á une sériê d'expériences. Le venin desséché rappelle, d'après le temps de conservations au Laboratoire, celui de Crotatus terrificus et celui des Lachesis (quand il est vieux). Il est retenu au passage en partie, par les bougies Berkfeld et Chamberland. La conservation en état de dessication est la meilleure. Ainsi gardé, à l'abri de la lumierè, aux approches de 0,gr., pendant 8 mois, il perd à peine 1,2 à 1,4 de sa valeur primitive. L'echauffement à 100 gr. trouble une dissolution de venin dans l'eau distilleé; sans atteindre toutefois son pouvoir toxique, quand on l'injecte par la voie intra-cérébrale. Nous avons fait l'experience par 11 voies diverses. Sur des animaux sensibles, nous n'avons pas obtenu de phénomènes toxiques, apparemment, par les voies suivantes: 1) buccale; 2) gastrique; 3) rectale; 4) chambre oculaire antérieure; 5) cornéenne; 6) trachéenne; 7) meningée {sur; intra; 8) simple contact, bien que direct, avec le systemè nerveux central. La gravité des phènomènes décroît suivant l'échelle ci-dessous: 1) intra-cérébrale...
Resumo:
A case of ganglioneuroma in the neck of a girl sixteen years old first noticed at the age of fifteen months is reported. The tumor successfully removed at operation has the size of an orange and is in relation by its internal surface with the trachea, oesophagus and vertebral column. Anteriorly it is crossed by the left common carotid and internal jugular vein which are meanwhile dissociated. Although this suggests an origin from the pneumogastric nerve no convincing proof of such an origin was obtained.
Resumo:
PURPOSE: To evaluate a diagnostic strategy for pulmonary embolism that combined clinical assessment, plasma D-dimer measurement, lower limb venous ultrasonography, and helical computed tomography (CT). METHODS: A cohort of 965 consecutive patients presenting to the emergency departments of three general and teaching hospitals with clinically suspected pulmonary embolism underwent sequential noninvasive testing. Clinical probability was assessed by a prediction rule combined with implicit judgment. All patients were followed for 3 months. RESULTS: A normal D-dimer level (<500 microg/L by a rapid enzyme-linked immunosorbent assay) ruled out venous thromboembolism in 280 patients (29%), and finding a deep vein thrombosis by ultrasonography established the diagnosis in 92 patients (9.5%). Helical CT was required in only 593 patients (61%) and showed pulmonary embolism in 124 patients (12.8%). Pulmonary embolism was considered ruled out in the 450 patients (46.6%) with a negative ultrasound and CT scan and a low-to-intermediate clinical probability. The 8 patients with a negative ultrasound and CT scan despite a high clinical probability proceeded to pulmonary angiography (positive: 2; negative: 6). Helical CT was inconclusive in 11 patients (pulmonary embolism: 4; no pulmonary embolism: 7). The overall prevalence of pulmonary embolism was 23%. Patients classified as not having pulmonary embolism were not anticoagulated during follow-up and had a 3-month thromboembolic risk of 1.0% (95% confidence interval: 0.5% to 2.1%). CONCLUSION: A noninvasive diagnostic strategy combining clinical assessment, D-dimer measurement, ultrasonography, and helical CT yielded a diagnosis in 99% of outpatients suspected of pulmonary embolism, and appeared to be safe, provided that CT was combined with ultrasonography to rule out the disease.
Resumo:
OBJECTIVE. The purpose of this study was to evaluate the prevalence of mesenteric venous thrombosis (MVT) in the Swiss Inflammatory Bowel Disease Cohort Study and to correlate MVT with clinical outcome. MATERIALS AND METHODS. Abdominal portal phase CT was used to examine patients with inflammatory bowel disease (IBD). Two experienced abdominal radiologists retrospectively analyzed the images, focusing on the superior and inferior mesenteric vein branches and looking for signs of acute or chronic thrombosis. The location of abnormalities was registered. The presence of MVT was correlated with IBD-related radiologic signs and complications. RESULTS. The cases of 160 patients with IBD (89 women, 71 men; Crohn disease [CD], 121 patients; ulcerative colitis [UC], 39 patients; median age at diagnosis, 27 years for patients with CD, 32 years for patients with UC) were analyzed. MVT was detected in 43 patients with IBD (26.8%). One of these patients had acute MVT; 38, chronic MVT; and four, both. The prevalence of MVT did not differ between CD (35/121 [28.9%]) and UC (8/39 [20.5%]) (p = 0.303). The location of thrombosis was different between CD and UC (CD, jejunal or ileal veins only [p = 0.005]; UC, rectocolic veins only [p = 0.001]). Almost all (41/43) cases of thrombosis were peripheral. MVT in CD patients was more frequently associated with bowel wall thickening (p = 0.013), mesenteric fat hypertrophy (p = 0.005), ascites (p = 0.002), and mesenteric lymph node enlargement (p = 0.036) and was associated with higher rate of bowel stenosis (p < 0.001) and more intestinal IBD-related surgery (p = 0.016) in the outcome. Statistical analyses for patients with UC were not relevant because of the limited population (n = 8). CONCLUSION. MVT is frequently found in patients with IBD. Among patients with CD, MVT is associated with bowel stenosis and CD-related intestinal surgery.
Resumo:
Patients who develop a severe stenosis in biological pulmonary conduits previously implanted for pulmonary outflow trunk reconstructions are treated either by surgical re-replacement, or by transcatheter stent-valve implantation through a femoral vein access. A catheter-based sub-xyphoidian access through the right ventricle for stent-valve positioning in a pulmonary conduit has rarely been proposed. We describe the case of a 20-year-old man who underwent a pulmonary trunk reconstruction for a congenital pulmonary valve dysplasia and a few years later developed a stenosis in the pulmonary conduit. He was successfully treated with a 23 mm Edwards Sapien stent-valve implantation in pulmonary position, through an unusual right ventricular, sub-xyphoidian access and without contrast medium injections and pleura opening.