918 resultados para sonic object


Relevância:

20.00% 20.00%

Publicador:

Resumo:

João Bernardo de Sena Esteves Falcão e Cunha

Relevância:

20.00% 20.00%

Publicador:

Resumo:

MAIDL, André Murbach; CARVILHE, Claudio; MUSICANTE, Martin A. Maude Object-Oriented Action Tool. Electronic Notes in Theoretical Computer Science. [S.l:s.n], 2008.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The morphogen Sonic Hedgehog (SHH) plays a critical role in the development of different tissues. In the central nervous system, SHH is well known to contribute to the patterning of the spinal cord and separation of the brain hemispheres. In addition, it has recently been shown that SHH signaling also contributes to the patterning of the telencephalon and establishment of adult neurogenic niches. In this work, we investigated whether SHH signaling influences the behavior of neural progenitors isolated from the dorsal telencephalon, which generate excitatory neurons and macroglial cells in vitro. We observed that SHH increases proliferation of cortical progenitors and generation of astrocytes, whereas blocking SHH signaling with cyclopamine has opposite effects. In both cases, generation of neurons did not seem to be affected. However, cell survival was broadly affected by blockade of SHH signaling. SHH effects were related to three different cell phenomena: mode of cell division, cell cycle length and cell growth. Together, our data in vitro demonstrate that SHH signaling controls cell behaviors that are important for proliferation of cerebral cortex progenitors, as well as differentiation and survival of neurons and astroglial cells.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goals of this study were to examine the visual information influence on body sway as a function of self- and object-motion perception and visual information quality. Participants that were aware (object-motion) and unaware (self-motion) of the movement of a moving room were asked to stand upright at five different distances from its frontal wall. The visual information effect on body sway decreased when participants were aware about the sensory manipulation. Moreover, while the visual influence on body sway decreased as the distance increased in the self-motion perception, no effects were observed in the object-motion mode. The overall results indicate that postural control system functioning can be altered by prior knowledge, and adaptation due to changes in sensory quality seem to occur in the self- but not in the object-motion perception mode. (C) 2004 Elsevier B.V.. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work reports a conception phase of a piston engine global model. The model objective is forecast the motor performance (power, torque and specific consumption as a function of rotation and environmental conditions). Global model or Zero-dimensional is based on flux balance through each engine component. The resulting differential equations represents a compressive unsteady flow, in which, all dimensional variables are areas or volumes. A review is presented first. The ordinary differential equation system is presented and a Runge-Kutta method is proposed to solve it numerically. The model includes the momentum conservation equation to link the gas dynamics with the engine moving parts rigid body mechanics. As an oriented to objects model the documentation follows the UML standard. A discussion about the class diagrams is presented, relating the classes with physical model related. The OOP approach allows evolution from simple models to most complex ones without total code rewrite. Copyright © 2001 Society of Automotive Engineers, Inc.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: This review of the literature intends to evaluate the effect of brushes with high frequency motion when compared with manual toothbrushes regarding the indices of plaque and gingival bleeding. METHODS: Patients presenting gingivitis and/or chronic periodontitis were evaluated in addition to patients having osseointegrated implants and fixed orthodontic appliances. Pertinent literature was reviewed to select articles according to previously defined inclusion criteria. RESULTS: In the assessed studies results showed significant decreases in plaque and gingival indices by utilization of both types of brushes. However, in the selected studies where sonic brushes were tested in orthodontic and dental implant patients there was a more significant decrease in the indices. Furthermore, there was no indication of gingival recession attributed to product use. CONCLUSION: Future studies with a more homogeneous methodology and better experiment designs will be needed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In this article, the authors measure throughput of sonic diamond microtubes and micronozzles that can work as passive gas flow controllers and flow meters under choking conditions. The behavior of the outlet pressure through the microdevices using an experimental setup with constant volume and constant temperature was determined in order to obtain the critical throughput, the critical mass flow rate, and the discharge coefficients of the diamond sonic microdevices. © 2007 American Vacuum Society.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of this study was to evaluate the shape of dental cavities made with the CVDentus® system using different ultrasound power levels. One standard cavity was made on the buccal aspect of 15 bovine incisors with a CVDentus® cylindrical bur (82142). The sample was divided into three groups: G1 - ultrasound with power II; G2 - ultrasound with power III; and G3 - ultrasound with power IV. A standardizing device was used to obtain standardized preparations and ultrasound was applied during one minute in each dental preparation. The cavities were sectioned in the middle, allowing observation of the cavity's profile with a magnifying glass, and width and depth measurement using the Leica Qwin program. The Kruskal-Wallis (p < 0.05) and Dunn statistical analyses demonstrated differences between the dental cavity shapes when powers III and IV were used. However, the cavities that were made with power III presented dimensions similar to those of the bur used for preparation. We concluded that the power recommended by the manufacturer (III) is the most adequate for use with the CVDentus® system.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This study quantified alterations in root dentin permeability after exposure to different acid beverages. Twenty-five third molars were sectioned below the cementoenamel junction, the root segment was collected, and the pulp tissue was removed. The root segments were connected to a hydraulic pressure apparatus to measure the permeability of root dentin after the following sequential steps, with 5 specimens in each: 1) phosphoric acid etching for 30 s (maximum permeability), 2) root planning to create new smear layer, 3) exposure to different acid substances for 5 min (orange, cola drink, vinegar, white wine, lemon juice), 4) toothbrushing with sonic toothbrush for 3 min, 5) toothbrushing with sonic toothbrush plus dentifrice for 3 min. Considering step I as 100%, the data were converted into percentage and each specimen was its own control. Data were analyzed statistically by Kruskal-Wallis and Dunn's post test at 5% significance level. All acidic substances increased dentin permeability significantly after scraping (p<0.05). Toothbrushing after exposure to acid substances decreased dentin permeability and the association with dentifrice accentuated the decrease (p<0.05), except for the specimens treated with cola drink. Thus, it may be concluded that all tested acid fruit juices increased dentin permeability, and toothbrushing with or without dentifrice can decrease root dentin permeability after dentin exposure to acid diet.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-conventional database management systems are used to achieve a better performance when dealing with complex data. One fundamental concept of these systems is object identity (OID), because each object in the database has a unique identifier that is used to access and reference it in relationships to other objects. Two approaches can be used for the implementation of OIDs: physical or logical OIDs. In order to manage complex data, was proposed the Multimedia Data Manager Kernel (NuGeM) that uses a logical technique, named Indirect Mapping. This paper proposes an improvement to the technique used by NuGeM, whose original contribution is management of OIDs with a fewer number of disc accesses and less processing, thus reducing management time from the pages and eliminating the problem with exhaustion of OIDs. Also, the technique presented here can be applied to others OODBMSs. © 2011 IEEE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Based on literature review, electronic systems design employ largely top-down methodology. The top-down methodology is vital for success in the synthesis and implementation of electronic systems. In this context, this paper presents a new computational tool, named BD2XML, to support electronic systems design. From a block diagram system of mixed-signal is generated object code in XML markup language. XML language is interesting because it has great flexibility and readability. The BD2XML was developed with object-oriented paradigm. It was used the AD7528 converter modeled in MATLAB / Simulink as a case study. The MATLAB / Simulink was chosen as a target due to its wide dissemination in academia and industry. From this case study it is possible to demonstrate the functionality of the BD2XML and make it a reflection on the design challenges. Therefore, an automatic tool for electronic systems design reduces the time and costs of the design.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Non-conventional database management systems are used to achieve a better performance when dealing with complex data. One fundamental concept of these systems is object identity (OID). Two techniques can be used for the implementation of OIDs: physical or logical. A logical implementation of OIDs, based on an Indirection Table, is used by NuGeM, a multimedia data manager kernel which is described in this paper. NuGeM Indirection Table allows the relocation of all pages in a database. The proposed strategy modifies the workings of this table so that it is possible to reduce considerably the number of I/O operations during the request and release of pages containing objects and their OIDs. Tests show a reduction of 84% in reading operations and a 67% reduction in writing operations when pages are requested. Although no changes were observed in writing operations during the release of pages, a 100% of reduction in reading operations was obtained. © 2012 IEEE.