987 resultados para single event upset
Resumo:
Immune systems have been used in the last years to inspire approaches for several computational problems. This paper focus on behavioural biometric authentication algorithms’ accuracy enhancement by using them more than once and with different thresholds in order to first simulate the protection provided by the skin and then look for known outside entities, like lymphocytes do. The paper describes the principles that support the application of this approach to Keystroke Dynamics, an authentication biometric technology that decides on the legitimacy of a user based on his typing pattern captured on he enters the username and/or the password and, as a proof of concept, the accuracy levels of one keystroke dynamics algorithm when applied to five legitimate users of a system both in the traditional and in the immune inspired approaches are calculated and the obtained results are compared.
Resumo:
The jet energy scale (JES) and its systematic uncertainty are determined for jets measured with the ATLAS detector using proton–proton collision data with a centre-of-mass energy of s√=7 TeV corresponding to an integrated luminosity of 4.7 fb −1 . Jets are reconstructed from energy deposits forming topological clusters of calorimeter cells using the anti- kt algorithm with distance parameters R=0.4 or R=0.6 , and are calibrated using MC simulations. A residual JES correction is applied to account for differences between data and MC simulations. This correction and its systematic uncertainty are estimated using a combination of in situ techniques exploiting the transverse momentum balance between a jet and a reference object such as a photon or a Z boson, for 20≤pjetT<1000 GeV and pseudorapidities |η|<4.5 . The effect of multiple proton–proton interactions is corrected for, and an uncertainty is evaluated using in situ techniques. The smallest JES uncertainty of less than 1 % is found in the central calorimeter region ( |η|<1.2 ) for jets with 55≤pjetT<500 GeV . For central jets at lower pT , the uncertainty is about 3 %. A consistent JES estimate is found using measurements of the calorimeter response of single hadrons in proton–proton collisions and test-beam data, which also provide the estimate for pjetT>1 TeV. The calibration of forward jets is derived from dijet pT balance measurements. The resulting uncertainty reaches its largest value of 6 % for low- pT jets at |η|=4.5 . Additional JES uncertainties due to specific event topologies, such as close-by jets or selections of event samples with an enhanced content of jets originating from light quarks or gluons, are also discussed. The magnitude of these uncertainties depends on the event sample used in a given physics analysis, but typically amounts to 0.5–3 %.
Resumo:
A search for the production of single-top-quarks in association with missing energy is performed in proton--proton collisions at a centre-of-mass energy of s√ = 8 TeV with the ATLAS experiment at the Large Hadron Collider using data collected in 2012, corresponding to an integrated luminosity of 20.3 fb−1. In this search, the W boson from the top quark is required to decay into an electron or a muon and a neutrino. No deviation from the Standard Model prediction is observed, and upper limits are set on the production cross-section for resonant and non-resonant production of an invisible exotic state in association with a right-handed top quark. In the case of resonant production, for a spin-0 resonance with a mass of 500 GeV, an effective coupling strength above 0.15 is excluded at 95% confidence level for the top quark and an invisible spin-1/2 state with mass between 0 GeV and 100 GeV. In the case of non-resonant production, an effective coupling strength above 0.2 is excluded at 95% confidence level for the top quark and an invisible spin-1 state with mass between 0 GeV and 657 GeV.
Resumo:
This paper presents a single-phase Series Active Power Filter (Series APF) for mitigation of the load voltage harmonic content, while maintaining the voltage on the DC side regulated without the support of a voltage source. The proposed series active power filter control algorithm eliminates the additional voltage source to regulate the DC voltage, and with the adopted topology it is not used a coupling transformer to interface the series active power filter with the electrical power grid. The paper describes the control strategy which encapsulates the grid synchronization scheme, the compensation voltage calculation, the damping algorithm and the dead-time compensation. The topology and control strategy of the series active power filter have been evaluated in simulation software and simulations results are presented. Experimental results, obtained with a developed laboratorial prototype, validate the theoretical assumptions, and are within the harmonic spectrum limits imposed by the international recommendations of the IEEE-519 Standard.
Resumo:
Polygyny, characterized by the presence of several egg-laying queens, is considered as a temporary colony status. In stingless bees it is rarely observed. This paper reports the first case of natural polygyny in Melipona scutellaris colony, with five egg-laying queens.
Resumo:
Several suction–water-content (s-w) calibrations for the filter paper method (FPM) used for soil-suction measurement have been published. Most of the calibrations involve a bilinear function (i.e., two different equations) with an inflection point occurring at 60 kPa
Resumo:
Programa Doutoral em Líderes para as Indústrias Tecnológicas
Resumo:
OBJECTIVE - This study compared the early and late results of the use of one single stent with those of the use of multiple stents in patients with lesions longer than 20mm. METHODS - Prospective assessment of patients electively treated with stents, with optimal stent deployment and followed-up for more than 3 months. From February '94 to January '98, 215 patients with lesions >20mm were treated. These patients were divided into 2 groups as follows: Group A - 105 patients (49%) with one stent implanted; Group B - 110 patients (51%) with multiple stents implanted. RESULTS - The mean length of the lesions was 26mm in group A (21-48mm) versus 29mm in group B (21-52mm) (p=0.01). Major complications occurred in one patient (0.9%) in group A (subacute thrombosis, myocardial infarctionand death) and in 2 patients (1.8%) in group B (one emergency surgery and one myocardial infarction) (p=NS). The results of the late follow-up period (>6 months) were similar for both groups (group A = 82% vs group B = 76%; p=NS), and we observed an event-free survical in 89% of the patients in group A and in 91% of the patients in group B (p=NS). Angina (group A = 11% vs group B = 7%) and lesion revascularization (group A = 5% vs group B = 6%; p=NS) also occurred in a similar percentage. No infarction or death was observed in the late follow-up period; restenosis was identified in 33% and 29% of the patients in groups A and B, respectively (p=NS). CONCLUSION - The results obtained using one stent and using multiple stents were similar; the greater cost-effectiveness of one stent implantation, however, seems to make this strategy the first choice.
Resumo:
"Available online 21 March 2016"
Resumo:
OBJETIVE: The evaluation, by exercise stress testing, of the cardiorespiratory effects of pyridostigmine (PYR), a reversible acetylcholinesterase inhibitor. METHODS: A double-blind, randomized, cross-over, placebo-controlled comparison of hemodynamic and ventilation variables of 10 healthy subjects who underwent three exercise stress tests (the first for adaptation and determination of tolerance to exercise, the other two after administration of placebo or 45mg of PYR). RESULTS: Heart rate at rest was: 68±3 vs 68±3bpm before and after placebo, respectively (P=0.38); 70±2 vs 59±2bpm, before and after pyridostigmine, respectively (P<0.01). During exercise, relative to placebo: a significantly lower heart rate after PYR at, respectively, 20% (P=0.02), 40% (P=0.03), 80% (P=0.05) and 100% (P=0.02) of peak effort was observed. No significant differences were observed in arterial blood pressure, oxygen consumption at submaximal and maximal effort, exercise duration, respiratory ratio, CO2 production, ventilation threshold, minute ventilation, and oxygen pulse. CONCLUSION: Pyridostigmine, at a dose of 45mg, decreases heart rate at rest and during exercise, with minimal side effects and without interfering with exercise tolerance and ventilation variables.
Resumo:
The case of a 16-year-old patient with atrioventricular tachycardia caused by a single left anterolateral accessory pathway is reported. When the patient underwent radiofrequency ablation, a lesion on the mitral annulus lateral wall produced changes in the retrograde atrial activation pattern determined by that pathway; changes ranged from a delay in depolarization of the annulus posterior portions to full left atrium counterclockwise activation. Such phenomena were probably caused by a block in the isthmus between the annulus and the lower left pulmonary vein ostium. This case illustrates the importance of the mitral-pulmonary isthmus in the process of left atrium activation, an alert to changes induced by its unintentional block during accessory pathway ablation.
Resumo:
This paper presents a model predictive current control applied to a proposed single-phase five-level active rectifier (FLAR). This current control strategy uses the discrete-time nature of the active rectifier to define its state in each sampling interval. Although the switching frequency is not constant, this current control strategy allows to follow the reference with low total harmonic distortion (THDF). The implementation of the active rectifier that was used to obtain the experimental results is described in detail along the paper, presenting the circuit topology, the principle of operation, the power theory, and the current control strategy. The experimental results confirm the robustness and good performance (with low current THDF and controlled output voltage) of the proposed single-phase FLAR operating with model predictive current control.
Resumo:
This work presents a molecular-scale agent-based model for the simulation of enzymatic reactions at experimentally measured concentrations. The model incorporates stochasticity and spatial dependence, using diffusing and reacting particles with physical dimensions. We developed strategies to adjust and validate the enzymatic rates and diffusion coefficients to the information required by the computational agents, i.e., collision efficiency, interaction logic between agents, the time scale associated with interactions (e.g., kinetics), and agent velocity. Also, we tested the impact of molecular location (a source of biological noise) in the speed at which the reactions take place. Simulations were conducted for experimental data on the 2-hydroxymuconate tautomerase (EC 5.3.2.6, UniProt ID Q01468) and the Steroid Delta-isomerase (EC 5.3.3.1, UniProt ID P07445). Obtained results demonstrate that our approach is in accordance to existing experimental data and long-term biophysical and biochemical assumptions.
Resumo:
East Germany, men, fertility, first births, event history analysis, problem-centered interviews, methodical integration, triangulation, social psychology, gender