843 resultados para shape descriptors
Resumo:
The HIV-1 RT inhibitory activity of 2-(2,6-dihalophenyl)-3-(substituted pyridin-2-yl)-thiazolidin-4-ones has been analyzed with different topological descriptors obtained from DRAGON software. Here, simple topological descriptors (TOPO), Galvez topological charge indices (GVZ) and 2D autocorrelation descriptors (2DAUTO) have been found to yield good predictive models for the activity of these compounds. The correlations obtained from the TOPO class descriptors suggest that less extended or compact saturated structural templates would be better for the activity. The participating GVZ class descriptors suggest that they have same degree of influence on the activity. In 2DAUTO class, the large participation of descriptors of lags seven and three indicate the association of activity information with the seven and three centered structural fragments of these compounds. The physicochemical weighting components of these descriptors suggest homogeneous influence of mass, volume, electronegativity and/ or polarizability on the activity.
Resumo:
In healthy people, glucose is metabolized through Embden-Meyerhoff pathway. In cases of diabetes mellitus, with the increased levels of glucose in insulin-insensitive tissues the Aldose Reductase (AR) in polyol pathway facilitates the conversion of glucose to sorbitol. In this cascade of events the accumulated sorbitol is attributed to be responsible for cataract, neuropathy and retinopathy in diabetic cases.1,2 Thus, the inhibition of AR in polyol pathway may prevent and lead to the cure of the complications arising out of the diabetes mellitus. In this background, Matsuda and coworkers3 studied the AR inhibitory activity of large number of flavones and related compounds from traditional antidiabetic remedies. Here, many of these compounds shared 2-Aryl-benzpyran-4-one as scaffold for different chemical groups surrounding this moiety. This offers scope to investigate the AR inhibitory activity of these compounds in relation to the functional group environment surrounding this core
Resumo:
Two series of closely related antimalarial agents, 7-chloro-4-(3’,5’-disubstitutedanilino) quinolines, have been analyzed using Combinatorial Protocol in Multiple Linear Regression (CP-MLR) for the structure-activity relations with more than 450 topological descriptors for each set. The study clearly suggested that 3’- and 5’- substituents of the anilino moiety map different domains in the activity space. While one domain favors the compact structural frames having aromatic, heterocyclic ring(s) substituted with closely spaced F, NO2 and O functional groups, the other prefers structural frames enriched with unsaturation, loops, branches, electronic content and devoid of carbonyl function. Also, this study gives an indication in favour of the electron rich centres in the aniline substituent groups for better antimalarial activity; an observation in line with several of the previous reports too. The models developed and the participating descriptors suggest that the substituent groups of the 4-anilino moiety of the 4-(3’, 5’-disubstitutedanilino)quinolines hold scope for further modification in the optimisation of the antimalarial activity.
Resumo:
One goal of interbody fusion is to increase the height of the degenerated disc space. Interbody cages in particular have been promoted with the claim that they can maintain the disc space better than other methods. There are many factors that can affect the disc height maintenance, including graft or cage design, the quality of the surrounding bone and the presence of supplementary posterior fixation. The present study is an in vitro biomechanical investigation of the compressive behaviour of three different interbody cage designs in a human cadaveric model. The effect of bone density and posterior instrumentation were assessed. Thirty-six lumbar functional spinal units were instrumented with one of three interbody cages: (1) a porous titanium implant with endplate fit (Stratec), (2) a porous, rectangular carbon-fibre implant (Brantigan) and (3) a porous, cylindrical threaded implant (Ray). Posterior instrumentation (USS) was applied to half of the specimens. All specimens were subjected to axial compression displacement until failure. Correlations between both the failure load and the load at 3 mm displacement with the bone density measurements were observed. Neither the cage design nor the presence of posterior instrumentation had a significant effect on the failure load. The loads at 3 mm were slightly less for the Stratec cage, implying lower axial stiffness, but were not different with posterior instrumentation. The large range of observed failure loads overlaps the potential in vivo compressive loads, implying that failure of the bone-implant interface may occur clinically. Preoperative measurements of bone density may be an effective tool to predict settling around interbody cages.
Resumo:
Randomly spread fibroblasts on fibronectin-coated elastomeric membranes respond to cyclic strain by a varying degree of focal adhesion assembly and actin reorganization. We speculated that the individual shape of the cells, which is linked to cytoskeletal structure and pre-stress, might tune these integrin-dependent mechanotransduction events. To this aim, fibronectin circles, squares and rectangles of identical surface area (2000μm(2)) were micro-contact printed onto elastomeric substrates. Fibroblasts plated on these patterns occupied the corresponding shapes. Cyclic 10% equibiaxial strain was applied to patterned cells for 30min, and changes in cytoskeleton and cell-matrix adhesions were quantified after fluorescence staining. After strain, megakaryocytic leukemia-1 protein translocated to the nucleus in most cells, indicating efficient RhoA activation independently of cell shape. However, circular and square cells (with radial symmetry) showed a significantly greater increase in the number of actin stress fibers and vinculin-positive focal adhesions after cyclic strain than rectangular (bipolar) cells of identical size. Conversely, cyclic strain induced larger changes in pY397-FAK positive focal complexes and zyxin relocation from focal adhesions to stress fibers in bipolar compared to symmetric cells. Thus, radially symmetric cells responded to cyclic strain with a larger increase in assembly, whereas bipolar cells reacted with more pronounced reorganization of actin stress fibers and matrix contacts. We conclude that integrin-mediated responses to external mechanical strain are differentially modulated in cells that have the same spreading area but different geometries, and do not only depend on mere cell size.
Resumo:
We derive multiscale statistics for deconvolution in order to detect qualitative features of the unknown density. An important example covered within this framework is to test for local monotonicity on all scales simultaneously. We investigate the moderately ill-posed setting, where the Fourier transform of the error density in the deconvolution model is of polynomial decay. For multiscale testing, we consider a calibration, motivated by the modulus of continuity of Brownian motion. We investigate the performance of our results from both the theoretical and simulation based point of view. A major consequence of our work is that the detection of qualitative features of a density in a deconvolution problem is a doable task, although the minimax rates for pointwise estimation are very slow.
Resumo:
Prevention and treatment of osteoporosis rely on understanding of the micromechanical behaviour of bone and its influence on fracture toughness and cell-mediated adaptation processes. Postyield properties may be assessed by nonlinear finite element simulations of nanoindentation using elastoplastic and damage models. This computational study aims at determining the influence of yield surface shape and damage on the depth-dependent response of bone to nanoindentation using spherical and conical tips. Yield surface shape and damage were shown to have a major impact on the indentation curves. Their influence on indentation modulus, hardness, their ratio as well as the elastic-to-total work ratio is well described by multilinear regressions for both tip shapes. For conical tips, indentation depth was not statistically significant (p<0.0001). For spherical tips, damage was not a significant parameter (p<0.0001). The gained knowledge can be used for developing an inverse method for identification of postelastic properties of bone from nanoindentation.