1000 resultados para second harmonic
Resumo:
OBJECTIVE: This study investigated the effectiveness of stereotactic body radiotherapy with helical TomoTherapy (T-SBRT) for treating medically inoperable primary and second-primary early stage non-small-cell lung neoplasm (SPLN) and evaluated whether the movement of organizing pneumonia (OP) within the irradiation field (IF) can be detected via analysis of radiological changes. METHODS: Patients (n = 16) treated for 1 year (2011-12) at our hospital by T-SBRT at a total dose of 60 Gy in five fractions were examined retrospectively. Outcome and toxicity were recorded and were separately described for SPLN. CT scans were reviewed by a single radiologist. RESULTS: Of the 16 patients, 5 (31.3%) had primary lung malignancies, 10 (62.5%) had SPLN, and 1 case (6.3%) had isolated mediastinal metastasis of lung neoplasm. Pathological evidence was obtained for 72.2% of all lesions. The median radiological follow-up was 11 months (10.5 months for SPLN). For all cases, the 6- and 12-month survival rates were 100% and 77.7% (100% and 71.4%, respectively, for SPLN), and the 6- and 12-month locoregional control rates were 100% in all cases. 2 (12.5%) of 16 patients developed grade 3 late transient radiation pneumonitis following steroid therapy and 1 (6.3%) presented asymptomatic infiltrates comparable to OP opacities. CONCLUSION: T-SBRT seems to be safe and effective. ADVANCES IN KNOWLEDGE: Mild OP is likely associated with radiation-induced anomalies in the IF, identification of migrating opacities can help discern relapse of radiation-induced opacities.
Resumo:
In this paper we describe a taxonomy of task demands which distinguishes between Task Complexity, Task Condition and Task Difficulty. We then describe three theoretical claims and predictions of the Cognition Hypothesis (Robinson 2001, 2003b, 2005a) concerning the effects of task complexity on: (a) language production; (b) interaction and uptake of information available in the input to tasks; and (c) individual differences-task interactions. Finally we summarize the findings of the empirical studies in this special issue which all address one or more of these predictions and point to some directions for continuing, future research into the effects of task complexity on learning and performance.
Resumo:
ZnO nanorods grown by both high temperature vapour phase transport and low temperature chemical bath deposition are very promising sources for UV third harmonic generation. Material grown by both methods show comparable efficiencies, in both cases an order of magnitude higher than surface third harmonic generation at the quartz-air interface of a bare quartz substrate. This result is in stark contrast to the linear optical properties of ZnO nanorods grown by these two methods, which show vastly different PL efficiencies. The third harmonic generated signal is analysed using intensity dependent measurements and interferometric frequency resolved optical gating, allowing extraction of the laser pulse parameters. The comparable levels of efficiency of ZnO grown by these very different methods as sources for third harmonic UV generation provides a broad suite of possible growth methods to suit various substrates, coverage and scalability requirements. Potential application areas range from interferometric frequency resolved optical gating characterization of few cycle fs pulses to single cell UV irradiation for biophysical studies.
Resumo:
BACKGROUND: Deep brain stimulation (DBS) is recognized as an effective treatment for movement disorders. We recently changed our technique, limiting the number of brain penetrations to three per side. OBJECTIVES: The first aim was to evaluate the electrode precision on both sides of surgery since we implemented this surgical technique. The second aim was to analyse whether or not the electrode placement was improved with microrecording and macrostimulation. METHODS: We retrospectively reviewed operation protocols and MRIs of 30 patients who underwent bilateral DBS. For microrecording and macrostimulation, we used three parallel channels of the 'Ben Gun' centred on the MRI-planned target. Pre- and post-operative MRIs were merged. The distance between the planned target and the centre of the implanted electrode artefact was measured. RESULTS: There was no significant difference in targeting precision on both sides of surgery. There was more intra-operative adjustment of the second electrode positioning based on microrecording and macrostimulation, which allowed to significantly approach the MRI-planned target on the medial-lateral axis. CONCLUSION: There was more electrode adjustment needed on the second side, possibly in relation with brain shift. We thus suggest performing a single central track with electrophysiological and clinical assessment, with multidirectional exploration on demand for suboptimal clinical responses.
Resumo:
By modifying a domain first suggested by Ruth Goodman in 1935 and by exploiting the explicit solution by Fedorov of the Polyá-Chebotarev problem in the case of four symmetrically placed points, an improved upper bound for the univalent Bloch-Landau constant is obtained. The domain that leads to this improved bound takes the form of a disk from which some arcs are removed in such a way that the resulting simply connected domain is harmonically symmetric in each arc with respect to the origin. The existence of domains of this type is established, using techniques from conformal welding, and some general properties of harmonically symmetric arcs in this setting are established.
Resumo:
BACKGROUND: Lithium augmentation of antidepressants for treatment of unipolar major depression was one of the first adjunctive strategies based on a neuropharmacologic rationale. Randomized controlled trials supported its efficacy but most trials added lithium to tricyclic antidepressants (TCAs). Despite its efficacy, use of lithium augmentation remains infrequent. The current systematic review and meta-analysis examines the efficacy of lithium augmentation as an adjunct to second generation antidepressants as well as to TCAs and considers reasons for its infrequent use. METHOD: A systematic search of Medline and the Cochrane Clinical Trials database was performed. Randomized, placebo-controlled trials of lithium augmentation were selected. A fixed-effects meta-analysis was performed. Odds ratios for response were calculated for each treatment-control contrast, for the trials grouped by type of initial antidepressant (TCA or second generation antidepressant), and as a meta-analytic summary for all treatments combined. RESULTS: Nine trials that included 237 patients were selected. The odds ratio for response to lithium vs. placebo in all contrasts combined was 2.89 (95% CI 1.65, 5.05, z=3.72, p=0.0002). Heterogeneity was very low, I(2)=0%. Adjunctive lithium was effective with TCAs (7 contrasts) and with second generation agents (3 contrasts). Discontinuation due to adverse events was infrequent and did not differ between lithium and placebo. LIMITATIONS: The meta-analysis is limited by the small size and number of trials and limited data for treatment resistant patients. CONCLUSIONS: Adjunctive lithium appears to be as effective for second generation antidepressants as it was for the tricyclics.
Resumo:
A smoke-free law came into effect in Spain on 1st January 2006, affecting all enclosed workplaces except hospitality venues, whose proprietors can choose among totally a smoke-free policy, a partial restriction with designated smoking areas, or no restriction on smoking on the premises. We aimed to evaluate the impact of the law among hospitality workers by assessing second-hand smoke (SHS) exposure and the frequency of respiratory symptoms before and one year after the ban.
Resumo:
PURPOSE: Statistical shape and appearance models play an important role in reducing the segmentation processing time of a vertebra and in improving results for 3D model development. Here, we describe the different steps in generating a statistical shape model (SSM) of the second cervical vertebra (C2) and provide the shape model for general use by the scientific community. The main difficulties in its construction are the morphological complexity of the C2 and its variability in the population. METHODS: The input dataset is composed of manually segmented anonymized patient computerized tomography (CT) scans. The alignment of the different datasets is done with the procrustes alignment on surface models, and then, the registration is cast as a model-fitting problem using a Gaussian process. A principal component analysis (PCA)-based model is generated which includes the variability of the C2. RESULTS: The SSM was generated using 92 CT scans. The resulting SSM was evaluated for specificity, compactness and generalization ability. The SSM of the C2 is freely available to the scientific community in Slicer (an open source software for image analysis and scientific visualization) with a module created to visualize the SSM using Statismo, a framework for statistical shape modeling. CONCLUSION: The SSM of the vertebra allows the shape variability of the C2 to be represented. Moreover, the SSM will enable semi-automatic segmentation and 3D model generation of the vertebra, which would greatly benefit surgery planning.
Resumo:
Collection : Archives de la linguistique française ; 188
Resumo:
Le cancer du poumon est la première cause de mortalité associée au cancer dans le monde. Le traitement curatif des tumeurs pulmonaires non-à-petites-cellules (NSCLC) diagnostiquées à un stade précoce se base sur une approche chirurgicale. Cependant, étant donné les comorbidités liées à la consommation de tabac, dont la bronchopneumopathie chronique occupe la première place, l'éligibilité chirurgicale pour ce type de cancer se trouve fréquemment limitée. Dans ce contexte, l'emploi de la radiothérapie stéréotaxique (SBRT) est une alternative valable chez les patients atteints d'un NSCLC primaire de stade précoce, et qui sont considérés inopérables à cause de leurs comorbidités. Depuis peu seulemement, le spectre de la SBRT a été élargi aux patients atteints d'un deuxième NSCLC primaire (SPLC), faisant suite à un premier NSCLC, traité avec un but curatif. Ils concernent donc des patients ayant déjà subits une intervention chirurgicale au préalable et qui présentent une réserve fonctionnelle pulmonaire extrêmement réduite. Le succès croissant de la SBRT résulte soit d'une efficacité thérapeutique comparables à la chirurgie, soit de sa toxicité qui semble limitée. À notre connaissance, seulement une étude a reporté des issues cliniques de patients affectés par des NSCLC primaires traités par SBRT. Cette dernière a utilisé la tomothérapie comme système d'irradiation (T-SBRT), sur un faible échantillon de patients (n = 27). Concernant l'irradiation des patients présentant des SPLC, la littérature disponible est pauvre et aucune publication a décrit l'utilisation de la T-SBRT. Ces éléments innovants ont donc motivé la rédaction d'un travail de thèse concernant les premières données cliniques de l'expérience faite au CHUV. Du point de vue des effets secondaires, si la pneumonie actinique précoce et tardive survenant au niveau du champ d'irradiation est désormais une complication iatrogène bien connue de la SBRT, une seule étude s'est intéressée à ce sujet dans le cadre de la T-SBRT. De plus, une entité bénigne et transitoire de pneumonie ( ?) a été reconnue depuis peu : la pneumonie organisée radio-induite (OP). Celle-ci semble se chevaucher comme un autre effet iatrogène à l'extérieur du champ d'irradiation. Originellement, cette dernière avait été rapportée dans les suites de la radiothérapie pour les cancer du sein. Elle a été décrite comme étant initialement limitée au champ d'irradiation et successivement pouvant s'étendre dynamiquement en dehors de celui-ci. Nous avons donc supposé que des infiltrats de OP peuvent être présents chez des patients asymptomatiques, et que ce dynamisme pourrait être identifié déjà au sein du champ d'irradiation. Notre étude a démontré que le traitement par T-SBRT garde des issues cliniques très encourageantes, aussi bien pour les tumeurs primaires que pour les SPLC. Entre autre, ce traitement semble avoir une toxicité limitée, et l'existence vraisemblable de la OP, déjà au sein du champ d'irradiation, peut aider les radiologues à différencier les infiltrats radio-induits d'une une récidive tumorale.
Resumo:
Introduction La stimulation cérébrale profonde est reconnue comme étant un traitement efficace des pathologies du mouvement. Nous avons récemment modifié notre technique chirurgicale, en limitant le nombre de pénétrations intracérébrales à trois par hémisphère. Objectif Le premier objectif de cette étude est d'évaluer la précision de l'électrode implantée des deux côtés de la chirurgie, depuis l'implémentation de cette technique chirurgicale. Le deuxième objectif est d'étudier si l'emplacement de l'électrode implantée était amélioré grâce à l'électrophysiologie. Matériel et méthode Il s'agit d'une étude rétrospective reprenant les protocoles opératoires et imageries à résonnance magnétique (IRM) cérébrales de 30 patients ayant subi une stimulation cérébrale profonde bilatérale. Pour l'électrophysiologie, nous avons utilisé trois canules parallèles du « Ben Gun », centrées sur la cible planifiée grâce à l'IRM. Les IRM pré- et post-opératoires ont été fusionnées. La distance entre la cible planifiée et le centre de l'artéfact de l'électrode implantée a été mesurée. Résultats Il n'y a pas eu de différence significative concernant la précision du ciblage des deux côtés (hémisphères) de la chirurgie. Il y a eu plus d'ajustements peropératoires du deuxième côté de la chirurgie, basé sur l'électrophysiologie, ce qui a permis d'approcher de manière significative la cible planifiée grâce à l'IRM, sur l'axe médio- latéral. Conclusion Il y a plus d'ajustements nécessaires de la position de la deuxième électrode, possiblement en lien avec le « brain shift ». Nous suggérons de ce fait d'utiliser une trajectoire d'électrode centrale accompagnée par de l'électrophysiologie, associé à une évaluation clinique. En cas de résultat clinique sub-optimal, nous proposons d'effectuer une exploration multidirectionnelle.