819 resultados para rater reliability
Resumo:
The aim of this study was to assess the ability to extract surgically relevant information from plain radiographs in trimalleolar fractures and to compare this with the information gathered from computed tomography (CT).
Resumo:
OBJECT: Ultrasound may be a reliable but simpler alternative to intraoperative MR imaging (iMR imaging) for tumor resection control. However, its reliability in the detection of tumor remnants has not been definitely proven. The aim of the study was to compare high-field iMR imaging (1.5 T) and high-resolution 2D ultrasound in terms of tumor resection control. METHODS: A prospective comparative study of 26 consecutive patients was performed. The following parameters were compared: the existence of tumor remnants after presumed radical removal and the quality of the images. Tumor remnants were categorized as: detectable with both imaging modalities or visible only with 1 modality. RESULTS: Tumor remnants were detected in 21 cases (80.8%) with iMR imaging. All large remnants were demonstrated with both modalities, and their image quality was good. Two-dimensional ultrasound was not as effective in detecting remnants<1 cm. Two remnants detected with iMR imaging were missed by ultrasound. In 2 cases suspicious signals visible only on ultrasound images were misinterpreted as remnants but turned out to be a blood clot and peritumoral parenchyma. The average time for acquisition of an ultrasound image was 2 minutes, whereas that for an iMR image was approximately 10 minutes. Neither modality resulted in any procedure-related complications or morbidity. CONCLUSIONS: Intraoperative MR imaging is more precise in detecting small tumor remnants than 2D ultrasound. Nevertheless, the latter may be used as a less expensive and less time-consuming alternative that provides almost real-time feedback information. Its accuracy is highest in case of more confined, deeply located remnants. In cases of more superficially located remnants, its role is more limited.
Resumo:
To interconnect a wireless sensor network (WSN) to the Internet, we propose to use TCP/IP as the standard protocol for all network entities. We present a cross layer designed communication architecture, which contains a MAC protocol, IP, a new protocol called Hop-to-Hop Reliability (H2HR) protocol, and the TCP Support for Sensor Nodes (TSS) protocol. The MAC protocol implements the MAC layer of beacon-less personal area networks (PANs) as defined in IEEE 802.15.4. H2HR implements hop-to-hop reliability mechanisms. Two acknowledgment mechanisms, explicit and implicit ACK are supported. TSS optimizes using TCP in WSNs by implementing local retransmission of TCP data packets, local TCP ACK regeneration, aggressive TCP ACK recovery, congestion and flow control algorithms. We show that H2HR increases the performance of UDP, TCP, and RMST in WSNs significantly. The throughput is increased and the packet loss ratio is decreased. As a result, WSNs can be operated and managed using TCP/IP.
Resumo:
There is a steadily increasing pressure on cost-savings and productivity growth in sectors of order-picking such that the wish for rationalization by automation is rising. Special problems are faced trying to automatize handling operations of order-picking articles packed in bags. The mechanical properties of the objects and their hard-to-predict shape and position represent obstacles and are complicating handling operations. A systematic approach in system design is required. This article deals with the properties of such products under aspects of difficulties arising in automated handling and points out a useful system development methodology.
Resumo:
INTRODUCTION Agitation is a major problem in acute schizophrenia. Only a few studies have tested antipsychotic agents in severely agitated patients, mainly because of legal issues. Furthermore, most studies were limited to the first 24 hours. We aimed to investigate the efficacy of oral haloperidol, risperidone, and olanzapine in reducing psychotic agitation in severely agitated patients with schizophrenia or schizophreniform or schizoaffective disorder over 96 hours using a prospective, randomized, rater-blinded, controlled design within a naturalistic treatment regimen. METHODS In total, 43 severely agitated patients at acute care psychiatric units were enrolled. Participants were randomly assigned to receive either daily haloperidol 15 mg, olanzapine 20 mg, or risperidone 2 to 6 mg over 5 days. Positive and Negative Syndrome Scale psychotic agitation subscale score was the primary outcome variable. A mixed-model analysis was applied. RESULTS All drugs were effective for rapid tranquilization within 2 hours. Over 5 days, the course differed between agents (P < 0.001), but none was superior. Dropouts occurred only in the risperidone and olanzapine groups. Men responded better to treatment than did women during the initial 2 hours (P = 0.046) as well as over the 5-day course (P < 0.001). No difference between drug groups was observed regarding diazepam or biperiden use. CONCLUSIONS Oral haloperidol, risperidone, and olanzapine seem to be suitable for treating acute severe psychotic agitation in schizophrenia spectrum disorders. Response to oral antipsychotics demonstrated a gender effect with poorer outcome in women throughout the study.
Resumo:
Lucid dream and nightmare frequencies vary greatly between individuals and to assess these differences reliable instruments are needed. The present study aimed to examine the reliability of eight-point scales for measuring lucid dream and nightmare frequencies. The scales were administered twice (with a four-week interval) to 93 sport students. A re-test reliability for the lucid dream frequency was found r=.89 (p<.001) and for the nightmare frequency r=.75 (p<.001). Both eight-point scales appear to be reliable measures for assessing individual differences in lucid dream and nightmare frequencies.
Resumo:
Background: The design of Virtual Patients (VPs) is essential. So far there are no validated evaluation instruments for VP design published. Summary of work: We examined three sources of validity evidence of an instrument to be filled out by students aimed at measuring the quality of VPs with a special emphasis on fostering clinical reasoning: (1) Content was examined based on theory of clinical reasoning and an international VP expert team. (2) Response process was explored in think aloud pilot studies with students and content analysis of free text questions accompanying each item of the instrument. (3) Internal structure was assessed by confirmatory factor analysis (CFA) using 2547 student evaluations and reliability was examined utilizing generalizability analysis. Summary of results: Content analysis was supported by theory underlying Gruppen and Frohna’s clinical reasoning model on which the instrument is based and an international VP expert team. The pilot study and analysis of free text comments supported the validity of the instrument. The CFA indicated that a three factor model comprising 6 items showed a good fit with the data. Alpha coefficients per factor were 0,74 - 0,82. The findings of the generalizability studies indicated that 40-200 student responses are needed in order to obtain reliable data on one VP. Conclusions: The described instrument has the potential to provide faculty with reliable and valid information about VP design. Take-home messages: We present a short instrument which can be of help in evaluating the design of VPs.
Resumo:
Lameness represents a major welfare and production issue in the poultry industry with a recent survey estimating 27% of birds lame and 3% unable to walk by 40 d of age. A variety of factors may induce lameness and are typically grouped into 2 broad classes on the basis of being infectious or skeletal in nature with the latter accounting for the majority of cases. The current work sought to build upon a large body of literature assessing the anatomical properties of bone in lame birds. Our specific objectives sought to identify relationships between relevant anatomical properties of the tibia and metatarsus using digital quantification from radiographs of legs and a measure of walking difficulty. Resulting output was statistically analyzed to assess 1) observer reliability for consistency in placing the leg during the radiograph procedure and quantification of the various measures within a radiograph, 2) the relationship between the various measurements of anatomical bone properties and sex, bird mass, and gait score, and 3) the relationship between each measurement and leg symmetry. Our anatomical bone measures were found to be reliable (intra-rater and test-retest reliabilities < 0.75) within radiograph for all measures and 8 of the 10 measures across radiographs. Several measures of bone properties in the tibia correlated to difficulty walking as measured by gait score (P < 0.05), indicating greater angulations with increasing lameness. Of the measures that manifested a gait score × bird mass interaction, heavier birds appeared to exhibit less angulation with increasing difficulty walking with lighter birds the opposite. These interactions suggest possibilities for influencing effects of activity or feed intake on bone mineralization with the bone angulation observed. Our efforts agree with that of others and indicate that angulation of the tibia may be related to lameness, though subsequent efforts involving comprehensive measures of bird activity, growth rates, and internal bone structure will be needed if the validity of the measures are to be accepted.