859 resultados para random loading


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Data comprising 1,719 milk yield records from 357 females (predominantly Murrah breed), daughters of 110 sires, with births from 1974 to 2004, obtained from the Programa de Melhoramento Genetic de Bubalinos (PROMEBUL) and from records of EMBRAPA Amazonia Oriental - EAO herd, located in Belem, Para, Brazil, were used to compare random regression models for estimating variance components and predicting breeding values of the sires. The data were analyzed by different models using the Legendre's polynomial functions from second to fourth orders. The random regression models included the effects of herd-year, month of parity date of the control; regression coefficients for age of females (in order to describe the fixed part of the lactation curve) and random regression coefficients related to the direct genetic and permanent environment effects. The comparisons among the models were based on the Akaike Infromation Criterion. The random effects regression model using third order Legendre's polynomials with four classes of the environmental effect were the one that best described the additive genetic variation in milk yield. The heritability estimates varied from 0.08 to 0.40. The genetic correlation between milk yields in younger ages was close to the unit, but in older ages it was low.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nonparametric simple-contrast estimates for one-way layouts based on Hodges-Lehmann estimators for two samples and confidence intervals for all contrasts involving only two treatments are found in the literature.Tests for such contrasts are performed from the distribution of the maximum of the rank sum between two treatments. For random block designs, simple contrast estimates based on Hodges-Lehmann estimators for one sample are presented. However, discussions concerning the significance levels of more complex contrast tests in nonparametric statistics are not well outlined.This work aims at presenting a methodology to obtain p-values for any contrast types based on the construction of the permutations required by each design model using a C-language program for each design type. For small samples, all possible treatment configurations are performed in order to obtain the desired p-value. For large samples, a fixed number of random configurations are used. The program prompts the input of contrast coefficients, but does not assume the existence or orthogonality among them.In orthogonal contrasts, the decomposition of the value of the suitable statistic for each case is performed and it is observed that the same procedure used in the parametric analysis of variance can be applied in the nonparametric case, that is, each of the orthogonal contrasts has a chi(2) distribution with one degree of freedom. Also, the similarities between the p-values obtained for nonparametric contrasts and those obtained through approximations suggested in the literature are discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During the winding process of HTS coils the tapes of Bi-2223 are subjected to the influence of bending strain, axial strain, compressive force and torsional deformation resulting in I-c degradation. In the literature the effects of the individual strain components are separately analyzed in spite of during coil winding and energizing the strain-stress effects are combined. In this work using commercial tapes of Bi-2223 Ag/AgMg with and without stainless steel reinforcement several samples were wound on cylindrical FRP G-10 holder in which different combined strains are applied. Measurements of I - V characteristic curves are done to determine the degree of critical current degradation and the operational limits. The results are compared with the I, values of short samples and other specimens subjected to deformation generated by loading types such as tensile and bending strain.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The SPPS methodology has continuously been investigated as a valuable model to monitor the solvation properties of polymeric materials. In this connection, the present work applied HRMAS-NMR spectroscopy to examine the dynamics of an aggregating peptide sequence attached to a resin core with varying peptide loading (up to 80%) and solvent system. Low and high substituted BHAR were used for assembling the VQAAIDYING sequence and some of its minor fragments. The HRMAS-NMR results were in agreement with the swelling of each resin, i.e. there was an improved resolution of resonance peaks in the better solvated conditions. Moreover, the peptide loading and the attached peptide sequence also affected the spectra. Strong peptide chain aggregation was observed mainly in highly peptide loaded resins when solvated in CDCl3. Conversely, due to the better swelling of these highly loaded resins in DMSO, improved NMR spectra were acquired in this polar aprotic solvent, thus enabling the detection of relevant sequence-dependent conformational alterations. The more prominent aggregation was displayed by the VQAAIDYING segment and not by any of its intermediary fragments and these findings were also corroborated by EPR studies of these peptide-resins labelled properly with an amino acid-type spin probe. Copyright (c) 2005 European Peptide Society and John Wiley & Sons, Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Alternative sampling procedures are compared to the pure random search method. It is shown that the efficiency of the algorithm can be improved with respect to the expected number of steps to reach an epsilon-neighborhood of the optimal point.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Experimental programs in constant and variable amplitude loading were performed to obtain a x N curves and to study retardation in fatigue crack growth due to overloads. The main aim of this research program was to analyse the effect of overload ratio and number of overload peaks. The effect of underloads, before and after the overload blocks was also studied. The generalised equation of Paris-Erdogan type was used for modelling of obtained data on crack propagation under constant amplitude load.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Enteropathogenic Escherichia coli ( EPEC) strains are important agents of infantile diarrhea all over the world, gaining even greater importance in developing countries. EPEC have also been isolated from various animal species, but most isolates belong to serotypes that differ from those recovered from humans. However, it has been demonstrated that several isolates from non- human primates belong to the serogroups and/ or serotypes related to those implicated in human disease. The objective of this study was to evaluate the genetic differences between thirteen strains isolated from non- human primates and the same number of strains isolated from human infections. Human isolates belonged to the same serogroup/ serotype as the monkey strains and the evaluation was done by analysis of random amplified polymorphic DNA. Dendrogram analysis showed that there was no clustering between human and monkey strains. Human and non- human isolates of the EPEC serotypes O127:H40 and O128:H2 shared 90 and 87% of their bands, respectively, indicating strong genomic similarity between the strains, leading to the speculation that they may have arisen from the same pathogenic clone. To our knowledge, this study is the first one comparing genomic similarity between human and non- human primate strains and the results provide further evidence that monkey EPEC strains correlate with human EPEC, as suggested in a previous investigation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Our aim was to assess the effects of magnesium sulphate given by iontophoresis on the viability of random skin flaps in rats. Endovenous magnesium sulphate is used to treat pre-eclampsia and diseases of blood vessels. Iontophoresis is an electrotherapeutic method which has shown satisfactory results in controlling ischaemia within the boundaries of the area in which it was given. Forty-five adult male Wistar rats, weighing 300 to 440 g were randomly divided into three groups of 15 animals each: random skin flap (control); random skin flap treated with magnesium sulphate without electrical stimulation; and random skin flap treated with magnesium sulphate with electrical stimulation of 4 mA for 20 minutes. The treatments were applied immediately after the operation and repeated on the following two days. The percentage of necrotic area was measured on the seventh postoperative day using a paper template. For each group, the mean percentage of flap necrosis was as follows: control, 46%; magnesium sulphate without electrical stimulation, 34%; and magnesium sulphate with electrical stimulation, 42%. There was no significant difference among the groups (p=0.18). Magnesium sulphate given by iontophoresis does not increase the viability of random skin flaps in rats.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the simultaneous rehabilitation of an edentulous patient with a hybrid (zygomatic and conventional implants) all-on-four implant-supported prosthesis for the maxilla and a standard (conventional implants) all-on-four implant-supported prosthesis for the mandible. The transfer impression was made with a multifunctional guide and the upper and lower prostheses were placed 24 h postoperatively. Clinical and radiographic examinations showed no infection or bony resorption 2 years later. Simultaneous maxillary and mandibular rehabilitation with all-on-four immediate loading is a viable, fast and effective option for edentulous patients. (C) 2009 Published by Elsevier Ltd on behalf of The British Association of Oral and Maxillofacial Surgeons.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work presents a comparative analysis about the behaviour of pile caps supported by 3 piles subjected to axial loading. Piles with 20 cm and 30 cm diameters were analysed. The main reinforcement was maintained in all the specimens, however, the arrangement of the secondary reinforcement varied. The main reinforcement consisted of steel bars connecting the piles. The secondary reinforcement was made up of: (a) bars going through the piles and through the projection of the column, (b) bars forming a network, and (c) vertical and horizontal stirrups. The main objective was the observation of the pile cap behaviour regarding the cracks and the modes of rupture. The real scale specimens were subjected to experimental tests until failure by rupture. Instruments were placed with the aim to obtain the displacement of the bases, the strains in the main and secondary reinforcement bars, in the compression struts, in the lower and upper nodal zones and in the sides of the caps. None of the caps reached failure by rupture with a load less than 1.12 times the theoretical load. The specimens ruptured due to the cracking of the compression strut and/or the yielding of the reinforcement bars in one direction.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We demonstrate random lasing action in a biopolymer that has large potential for medical applications. The novel random laser consists of nanofibers of bacterial cellulose impregnated with silica nanoparticles and Rhodamine 6G.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives. Evaluate the flexural strength (sigma) and subcritical crack growth (SCG) under cyclic loading of glass-infiltrated alumina-based (IA, In-Ceram Alumina) and zirconia-reinforced (IZ, In-Ceram Zirconia) ceramics, testing the hypothesis that wet environment influences the SCG of both ceramics when submitted to cyclic loading.Methods. Bar-shaped specimens of IA (n = 45) and IZ ( n = 45) were fabricated and loaded in three-point bending (3P) in 37 degrees C artificial saliva (IA(3P) and IZ(3P)) and cyclic fatigued (F) in dry (D) and wet (W) conditions (IA(FD), IA(FW), IZ(FD), IZ(FW)). The initial sigma and the number of cycles to fracture were obtained from 3P and F tests, respectively. Data was examined using Weibull statistics. The SCG behavior was described in terms of crack velocity as a function of maximum stress intensity factor (K(Imax)).Results. The Weibull moduli (m = 8) were similar for both ceramics. The characteristic strength (sigma(0)) of IA and IZ was and 466 MPa 550 MPa, respectively. The wet environment significantly increased the SCG of IZ, whereas a less evident effect was observed for IA. In general, both ceramics were prone to SCG, with crack propagation occurring at K(I) as low as 43-48% of their critical K(I). The highest sigma of IZ should lead to longer lifetimes for similar loading conditions.Significance. Water combined with cyclic loading causes pronounced SCG in IZ and IA materials. The lifetime of dental restorations based on these ceramics is expected to increase by reducing their direct exposure to wet conditions and/or by using high content zirconia ceramics with higher strength. (C) 2010 Academy of Dental Materials. Published by Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AimTo evaluate prospectively the clinical and radiographic outcomes after 2 years of loading of 6 mm long moderately rough implants supporting single crowns in the posterior regions.Material and methodsForty SLActive Straumann (R) short (6 mm) implants were placed in 35 consecutively treated patients. Nineteen implants, 4.1 mm in diameter, and 21 implants, 4.8 mm in diameter, were installed. Implants were loaded after 6 weeks of healing. Implant survival rate, marginal bone loss and resonance frequency analysis (RFA) were evaluated at different intervals. The clinical crown/implant ratio was also calculated.ResultsTwo out of 40 implants were lost before loading. Hence, the survival rate before loading was 95%. No further technical or biological complications were encountered during the 2-year follow-up. The mean marginal bone loss before loading was 0.34 +/- 0.38 mm. After loading, the mean marginal bone loss was 0.23 +/- 0.33 and 0.21 +/- 0.39 mm at the 1- and 2-year follow-ups. The RFA values increased between insertion (70.2 +/- 9) and the 6-week evaluation (74.8 +/- 6.1). The clinical crown/implant ratio increased with time from 1.5 at the delivery of the prosthesis to 1.8 after 2 years of loading.ConclusionShort implants (6 mm) with a moderately rough surface loaded early (after 6 weeks) during healing yielded high implant survival rates and moderate loss of bone after 2 years of loading. Longer observation periods are needed to draw more definite conclusions on the reliability of short implants supporting single crowns.To cite this article:Rossi F, Ricci E, Marchetti C, Lang NP, Botticelli D. Early loading of single crowns supported by 6-mm-long implants with a moderately rough surface: a prospective 2-year follow-up cohort study.Clin. Oral Impl. Res. 21, 2010; 937-943.doi: 10.1111/j.1600-0501.2010.01942.x.