975 resultados para pulse-width modulator


Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE: To verify if there is difference in the buccal and posterior corridor width in cases treated with extraction of one and four premolars. METHODS: Through posed smile photographs of 23 Class II patients, subdivision, treated with extraction of one premolar and 25 Class I and Class II patients, subdivision, treated with extraction of four premolars, the percentage of buccal and posterior corridor width was calculated. The two protocols of extractions were compared regarding the buccal and posterior corridor width by independent t tests. RESULTS: There was no statistically significant difference on the buccal and posterior corridor widths between patients treated with symmetric and asymmetric extraction. CONCLUSION: The buccal and posterior corridor did not differ between the evaluated protocols of extractions.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We present a new Ultra Wide Band (UWB) Timed- Array Transmitter System with Beamforming capability for high-resolution remote acquisition of vital signals. The system consists of four identical channels, where each is formed of a serial topology with three modules: programmable delay circuit (PDC or τ), a novel UWB 5th Gaussian Derivative order pulse generator circuit (PG), and a planar Vivaldi antenna. The circuit was designed using 0.18μm CMOS standard process and the planar antenna array was designed with filmconductor on Rogers RO3206 substrate. Spice simulations results showed the pulse generation with 104 mVpp amplitude and 500 ps width. The power consumption is 543 μW, and energy consumption 0.27 pJ per pulse using a 2V power supply at a pulse repetition rate (PRR) of 100 MHz. Electromagnetic simulations results, using CST Microwave (MW) Studio 2011, showed the main lobe radiation with a gain maximum of 13.2 dB, 35.5º x 36.7º angular width, and a beam steering between 17º and -11º for azimuthal (θ) angles and 17º and -18º for elevation (φ) angles at the center frequency of 6 GHz

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We report the control of Au nanoparticle (NP) formation by using shaped 30 fs pulses, in a solution containing HAuCl4 and chitosan. By using a sinusoidal spectral phase, a periodic train of pulses is generated. When the period of the pulse train matches certain Raman resonances of chitosan, the reducing agent of the process, an enhancement of the Au NP formation is observed. Theoretical quantum chemical calculations indicate that the outer groups of the chitosan are mostly influenced by low Raman frequencies, which is in reasonably agreement with the experimental data and indicates an enhancement in the Au NP formation as the pulse train period increases (low frequency).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Investigation on impulsive signals, originated from Partial Discharge (PD) phenomena, represents an effective tool for preventing electric failures in High Voltage (HV) and Medium Voltage (MV) systems. The determination of both sensors and instruments bandwidths is the key to achieve meaningful measurements, that is to say, obtaining the maximum Signal-To-Noise Ratio (SNR). The optimum bandwidth depends on the characteristics of the system under test, which can be often represented as a transmission line characterized by signal attenuation and dispersion phenomena. It is therefore necessary to develop both models and techniques which can characterize accurately the PD propagation mechanisms in each system and work out the frequency characteristics of the PD pulses at detection point, in order to design proper sensors able to carry out PD measurement on-line with maximum SNR. Analytical models will be devised in order to predict PD propagation in MV apparatuses. Furthermore, simulation tools will be used where complex geometries make analytical models to be unfeasible. In particular, PD propagation in MV cables, transformers and switchgears will be investigated, taking into account both irradiated and conducted signals associated to PD events, in order to design proper sensors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Im Rahmen dieser Arbeit wurde ein flugzeuggetragenes Laserablations-Einzelpartikel-Massenspektrometer von Grund auf entworfen, gebaut, charakterisiert und auf verschiedenen Feldmesskampagnen eingesetzt. Das ALABAMA (Aircraft-based Laser ABlation Aerosol MAss Spectrometer) ist in der Lage die chemische Zusammensetzung und Größe von einzelnen Aerosolpartikeln im submikrometer-Bereich (135 – 900 nm) zu untersuchen.rnNach dem Fokussieren in einer aerodynamischen Linse wird dafür zunächst derrnaerodynamische Durchmesser der einzelnen Partikel mit Hilfe einer Flugzeitmessung zwischen zwei Dauerstrichlasern bestimmt. Anschließend werden die zuvor detektierten und klassifizierten Partikel durch einen gezielten Laserpuls einzeln verdampft und ionisiert. Die Ionen werden in einem bipolaren Flugzeit-Massenspektrometer entsprechend ihrem Masse zu- Ladungs Verhältnisses getrennt und detektiert. Die entstehenden Massenspektren bieten einen detaillierten Einblick in die chemische Struktur der einzelnen Partikel.rnDas gesamte Instrument wurde so konzipiert, dass es auf dem neuen Höhenforschungsflugzeug HALO und anderen mobilen Plattformen eingesetzt werden kann. Um dies zu ermöglichen wurden alle Komponenten in einem Rahmen mit weniger als 0.45 m³ Volumen untergebracht. Das gesamte Instrument inklusive Rahmen wiegt weniger als 150 kg und erfüllt die strengen sicherheitsvorschriften für den Betrieb an Bord von Forschungsflugzeugen. Damit ist ALABAMA das kleinste und leichteste Instrument seiner Art.rnNach dem Aufbau wurden die Eigenschaften und Grenzen aller Komponenten detailliert im Labor und auf Messkampagnen charakterisiert. Dafür wurden zunächst die Eigenschaften des Partikelstrahls, wie beispielsweise Strahlbreite und –divergenz, ausführlich untersucht. Die Ergebnisse waren wichtig, um die späteren Messungen der Detektions- und Ablationseffizienz zu validieren.rnBei den anschließenden Effizienzmessungen wurde gezeigt, dass abhängig von ihrer Größe und Beschaffenheit, bis zu 86 % der vorhandenen Aerosolpartikel erfolgreich detektiert und größenklassifiziert werden. Bis zu 99.5 % der detektierten Partikel konnten ionisiert und somit chemisch untersucht werden. Diese sehr hohen Effizienzen sind insbesondere für Messungen in großer Höhe entscheidend, da dort zum Teil nur sehr geringe Partikelkonzentrationen vorliegen.rnDas bipolare Massenspektrometer erzielt durchschnittliche Massenauflösungen von bis zu R=331. Während Labor- und Feldmessungen konnten dadurch Elemente wie Au, Rb, Co, Ni, Si, Ti und Pb eindeutig anhand ihres Isotopenmusters zugeordnet werden.rnErste Messungen an Bord eines ATR-42 Forschungsflugzeuges während der MEGAPOLI Kampagne in Paris ergaben einen umfassenden Datensatz von Aerosolpartikeln innerhalb der planetaren Grenzschicht. Das ALABAMA konnte unter harten physischen Bedingungen (Temperaturen > 40°C, Beschleunigungen +/- 2 g) verlässlich und präzise betrieben werden. Anhand von charakteristischen Signalen in den Massenspektren konnten die Partikel zuverlässig in 8 chemische Klassen unterteilt werden. Einzelne Klassen konnten dabei bestimmten Quellen zugeordnet werden. So ließen sich beispielsweise Partikel mit starkerrnNatrium- und Kaliumsignatur eindeutig auf die Verbrennung von Biomasse zurückführen.rnALABAMA ist damit ein wertvolles Instrument um Partikel in-situ zu charakterisieren und somit verschiedenste wissenschaftliche Fragestellungen, insbesondere im Bereich der Atmosphärenforschung, zu untersuchen.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Within this thesis a new double laser pulse pumping scheme for plasma-based, transient collisionally excited soft x-ray lasers (SXRL) was developed, characterized and utilized for applications. SXRL operations from ~50 up to ~200 electron volt were demonstrated applying this concept. As a central technical tool, a special Mach-Zehnder interferometer in the chirped pulse amplification (CPA) laser front-end was developed for the generation of fully controllable double-pulses to optimally pump SXRLs.rnThis Mach-Zehnder device is fully controllable and enables the creation of two CPA pulses of different pulse duration and variable energy balance with an adjustable time delay. Besides the SXRL pumping, the double-pulse configuration was applied to determine the B-integral in the CPA laser system by amplifying short pulse replica in the system, followed by an analysis in the time domain. The measurement of B-integral values in the 0.1 to 1.5 radian range, only limited by the reachable laser parameters, proved to be a promising tool to characterize nonlinear effects in the CPA laser systems.rnContributing to the issue of SXRL pumping, the double-pulse was configured to optimally produce the gain medium of the SXRL amplification. The focusing geometry of the two collinear pulses under the same grazing incidence angle on the target, significantly improved the generation of the active plasma medium. On one hand the effect was induced by the intrinsically guaranteed exact overlap of the two pulses on the target, and on the other hand by the grazing incidence pre-pulse plasma generation, which allows for a SXRL operation at higher electron densities, enabling higher gain in longer wavelength SXRLs and higher efficiency at shorter wavelength SXRLs. The observation of gain enhancement was confirmed by plasma hydrodynamic simulations.rnThe first introduction of double short-pulse single-beam grazing incidence pumping for SXRL pumping below 20 nanometer at the laser facility PHELIX in Darmstadt (Germany), resulted in a reliable operation of a nickel-like palladium SXRL at 14.7 nanometer with a pump energy threshold strongly reduced to less than 500 millijoule. With the adaptation of the concept, namely double-pulse single-beam grazing incidence pumping (DGRIP) and the transfer of this technology to the laser facility LASERIX in Palaiseau (France), improved efficiency and stability of table-top high-repetition soft x-ray lasers in the wavelength region below 20 nanometer was demonstrated. With a total pump laser energy below 1 joule the target, 2 mircojoule of nickel-like molybdenum soft x-ray laser emission at 18.9 nanometer was obtained at 10 hertz repetition rate, proving the attractiveness for high average power operation. An easy and rapid alignment procedure fulfilled the requirements for a sophisticated installation, and the highly stable output satisfied the need for a reliable strong SXRL source. The qualities of the DGRIP scheme were confirmed in an irradiation operation on user samples with over 50.000 shots corresponding to a deposited energy of ~ 50 millijoule.rnThe generation of double-pulses with high energies up to ~120 joule enabled the transfer to shorter wavelength SXRL operation at the laser facility PHELIX. The application of DGRIP proved to be a simple and efficient method for the generation of soft x-ray lasers below 10 nanometer. Nickel-like samarium soft x-ray lasing at 7.3 nanometer was achieved at a low total pump energy threshold of 36 joule, which confirmed the suitability of the applied pumping scheme. A reliable and stable SXRL operation was demonstrated, due to the single-beam pumping geometry despite the large optical apertures. The soft x-ray lasing of nickel-like samarium was an important milestone for the feasibility of applying the pumping scheme also for higher pumping pulse energies, which are necessary to obtain soft x-ray laser wavelengths in the water window. The reduction of the total pump energy below 40 joule for 7.3 nanometer short wavelength lasing now fulfilled the requirement for the installation at the high-repetition rate operation laser facility LASERIX.rn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Oxidativer Stress in Form reaktiver Sauerstoffspezies (ROS) und Exzitotoxizität durch supraphysiologische Konzentrationen des Neurotransmitters Glutamat sind nicht nur beteiligt an der Pathogenese vielzähliger neurodegenerativer Erkrankungen wie Schlaganfall, Hirntrauma, Alzheimer Demenz oder Multipler Sklerose, sondern spielen zudem eine Schlüsselrolle im dort beobachteten Zusammenbruch der Blut-Hirn-Schranke. Glutamat führt durch Stimulation neuronaler und endothelialer NMDA-Rezeptoren zu einer Generierung von ROS. Nicht verfolgt worden war bisher, welche Auswirkungen ROS umgekehrt auch auf den NMDA-Rezeptor haben könnten. Im Rahmen der vorliegenden Arbeit wurde daher untersucht, ob und in welcher Weise die Exposition gegenüber reaktiven Sauerstoffspezies einen Einfluss auf die Expression und Aktivierbarkeit von NMDA-Rezeptoren auf zerebrovaskulären Endothelzellen ausübt.rnEs konnte zunächst die Expression der funktionell obligaten NR-1 Untereinheit des NMDA-Rezeptors auf der verwendeten Zelllinie b.End3 mittels Immunfluoreszenz-Mikroskopie gesichert werden. Ein Nachweis von mRNA für die Untereinheiten NR1 und NR2B, C und D erfolgte mittels RT-PCR. In der Analyse der replizierten RNA zeigten sich Hinweise für eine heterogene Komposition der exprimierten endothelialen NMDA-Rezeptoren.rnEs konnte weiter mit Hilfe der In-Cell-Western-Technik gezeigt werden, dass die Expression des NMDA-Rezeptors durch transiente Stimulation mit reaktiven Sauerstoffspezies im Sinne einer Heraufregulation moduliert werden kann. Die Stimulation der Zellen mit den reaktiven Sauerstoffspezies O2-, ONOO- und H2O2 führte dabei im Experiment zu einer deutlichen Zunahme der NR1-Expression, die spätestens nach 72 Stunden höchst signifikant war.rnUm zu überprüfen, welche Bedeutung diese Überexpression für die Integrität der Blut-Hirn-Schranke unter den exzitotoxischen Bedingungen hoher Glutamatkonzentrationen haben könnte, wurde mit Hilfe des ECIS-Systems („Electrical Cell-Substrate Impedance Sensing“) die Impedanz ROS-präexponierter Endothelmonolayer gemessen. Auf Rezeptorstimulation mit dem spezifischen Agonisten NMDA reagierten die vorbehandelten Gruppen mit einem Abfall der Impedanz gegenüber der nicht vorbehandelten Kontrolle.rnrnDie vorliegenden Ergebnisse zeigen, dass ROS in der Lage sind, funktionelle endotheliale NMDA-Rezeptoren zu induzieren und auf diesem Weg zu einem verstärkten Abfall der BHS-Integrität unter den Bedingungen exzitotoxischen und oxidativen Stresses führen. Dies stellt einen neuen Mechanismus zur Erklärung der Pathogenese des Blut-Hirn-Schrankenversagens dar.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Immune modulation by herpesviruses, such as cytomegalovirus, is critical for the establishment of acute and persistent infection confronting a vigorous antiviral immune response of the host. Therefore, the action of immune-modulatory proteins has long been the subject of research, with the final goal to identify new strategies for antiviral therapy.rnIn the case of murine cytomegalovirus (mCMV), the viral m152 protein has been identified to play a major role in targeting components of both the innate and the adaptive immune system in terms of infected host-cell recognition in the effector phase of the antiviral immune response. On the one hand, it inhibits cell surface expression of RAE-1 and thereby prevents ligation of the activating natural killer (NK)-cell receptor NKG2D. On the other hand, it decreases cell surface expression of peptide-loaded MHC class I molecules thereby preventing antigen presentation to CD8 T cells. Ultimately, the outcome of CMV infection is determined by the interplay between viral and cellular factors.rnIn this context, the work presented here has revealed a novel and intriguing connection between viral m152 and cellular interferon (IFN), a key cytokine of the immune system: rnthe m152 promoter region contains an interferon regulatory factor element (IRFE) perfectly matching the consensus sequence of cellular IRFEs.rnThe biological relevance of this regulatory element was first suggested by sequence comparisons revealing its evolutionary conservation among various established laboratory strains of mCMV and more recent low-passage wild-derived virus isolates. Moreover, search of the mCMV genome revealed only three IRFE sites in the complete sequence. Importantly, the functionality of the IRFE in the m152 promoter was confirmed with the use of a mutant virus, representing a functional deletion of the IRFE, and its corresponding revertant virus. In particular, m152 gene expression was found to be inhibited in an IRFE-dependent manner in infected cells. Essentially, this inhibition proved to have a severe impact on the immune-modulatory function of m152, first demonstrated by a restored direct antigen presentation on infected cells for CD8 T-cell activation. Even more importantly, this effect of IRFE-mediated IFN signaling was validated in vivo by showing that the protective antiviral capacity of adoptively-transferred, antigen-specific CD8 T cells is also significantly restored by the IRFE-dependent inhibition of m152. Somewhat curious and surprising, the decrease in m152 protein simultaneously prevented an enhanced activation of NK cells in acute-infected mice, apparently independent of the RAE-1/NKG2D ligand/receptor interaction but rather due to reduced ‘missing-self’ recognition.rnTaken together, this work presents a so far unknown mechanism of IFN signaling to control mCMV immune modulation in acute infection.rnrn

Relevância:

20.00% 20.00%

Publicador:

Resumo:

During short-term postural changes, the factors determining the amplitude of intracranial pulse pressure (ICPPA) remain constant, except for cerebrovascular resistance (CVR). Therefore, it may be possible to draw conclusions from the ICPPA onto the cerebrovascular resistance (CVR) and thus the relative change in cerebral perfusion pressure (CPP).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Since the late 1950s, reports on an unusual giant-cell granulomatous lesion affecting the jaws, lungs, stomach and intestines have been published. Histopathologically, the lesions showed the presence of structureless hyaline rings with multinucleated giant cells. The aim of this review was to summarize the literature on the etiopathogenesis of the so-called oral and extraoral pulse or hyaline ring granuloma. Literature was searched using PubMed and Medline. In addition, hand search was performed. Search words were oral and extraoral hyaline ring granuloma, giant-cell hyaline angiopathy, pulse granuloma and chronic periostitis. Numerous terms for hyaline ring granuloma have been introduced over time (1971-2008). One hundred seventy-three cases of oral hyaline ring granuloma have been retrieved from the literature. In the mandible, 72.3% occurred . Two theories for etiopathogenesis have been proposed: (1) the origin of the hyaline rings is due to a foreign material (pulse and legumes) having penetrated the oral mucosa or gastrointestinal tract and lungs (exogenous theory) and (2) the rings are due to hyaline degenerative changes in walls of blood vessels (endogenous theory). Experimental production of oral and extraoral hyaline ring granulomas is consistent with the exogenous origin. Particles or remains of leguminous cells having been implanted or aspirated into human tissues whether located to the oral cavity or throughout the entire digestive tract and respiratory system are thought to be causative. Pulse or hyaline ring granulomas are rare but are well-defined oral and extraoral lesions due to implantation of the cellulose moiety of plant foods in contrast to the starch components.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Sphingosine-1-phosphate (S1P) acts as high affinity agonist at specific G-protein-coupled receptors, S1P(1-5), that play important roles e.g. in the cardiovascular and immune systems. A S1P receptor modulating drug, FTY720 (fingolimod), has been effective in phase III clinical trials for multiple sclerosis. FTY720 is a sphingosine analogue and prodrug of FTY720-phosphate, which activates all S1P receptors except S1P(2) and disrupts lymphocyte trafficking by internalizing the S1P(1) receptor. Cis-4-methylsphingosine (cis-4M-Sph) is another synthetic sphingosine analogue that is readily taken up by cells and phosphorylated to cis-4-methylsphingosine-1-phosphate (cis-4M-S1P). Therefore, we analysed whether cis-4M-Sph interacted with S1P receptors through its metabolite cis-4M-S1P in a manner similar to FTY720. Indeed, cis-4M-Sph caused an internalization of S1P receptors, but differed from FTY720 as it acted on S1P(2) and S1P(3) and only weakly on S1P(1), while FTY720 internalized S1P(1) and S1P(3) but not S1P(2). Consequently, pre-incubation with cis-4M-Sph specifically desensitized S1P-induced [Ca(2+)](i) increases, which are mediated by S1P(2) and S1P(3), in a time- and concentration-dependent manner. This effect was not shared by sphingosine or FTY720, indicating that metabolic stability and targeting of S1P(2) receptors were important. The desensitization of S1P-induced [Ca(2+)](i) increases was dependent on the expression of SphKs, predominantly of SphK2, and thus mediated by cis-4M-S1P. In agreement, cis-4M-S1P was detected in the supernatants of cells exposed to cis-4M-Sph. It is concluded that cis-4M-Sph, through its metabolite cis-4M-S1P, acts as a S1P receptor modulator and causes S1P receptor internalization and desensitization. The data furthermore help to define requirements for sphingosine kinase substrates as S1P receptor modulating prodrugs.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulse-pressure variation (PPV) due to increased right ventricular afterload and dysfunction may misleadingly suggest volume responsiveness. We aimed to assess prediction of volume responsiveness with PPV in patients with increased pulmonary artery pressure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We found that pulse pressure variation (PPV) did not predict volume responsiveness in patients with increased pulmonary artery pressure. This study tests the hypothesis that PPV does not predict fluid responsiveness during an endotoxin-induced acute increase in pulmonary artery pressure and right ventricular loading.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Induced mild hypothermia after cardiac arrest interferes with clinical assessment of the cardiovascular status of patients. In this situation, non-invasive cardiac output measurement could be useful. Unfortunately, arterial pulse contour is altered by temperature, and the performance of devices using arterial blood pressure contour analysis to derive cardiac output may be insufficient.