927 resultados para movie rating
Resumo:
Video presented as part of ACIS 2009 conference in Melbourne Australia. This movie is a demonstration of the use of 3D Virtual Environments to visualise 3D BPMN Process Models, and in particular, to highlight any issues with the process model that are spatial in nature. This work is part of a paper accepted for the Asia-Pacific Conference on Conceptual Modelling (APCCM 2010) to be held in Brisbane - http://2010.apccm.org/
Resumo:
Cold-formed steel lipped channels are commonly used in LSF wall construction as load bearing studs with plasterboards on both sides. Under fire conditions, cold-formed thin-walled steel sections heat up quickly resulting in fast reduction in their strength and stiffness. Usually the LSF wall panels are subjected to fire from one side which will cause thermal bowing, neutral axis shift and magnification effects due to the development of non-uniform temperature distributions across the stud. This will induce an additional bending moment in the stud and hence the studs in LSF wall panels should be designed as a beam column considering both the applied axial compression load and the additional bending moment. Traditionally the fire resistance rating of these wall panels is based on approximate prescriptive methods. Very often they are limited to standard wall configurations used by the industry. Therefore a detailed research study is needed to develop fire design rules to predict the failure load and hence the failure time of LSF wall panels subject to non-uniform temperature distributions. This paper presents the details of an investigation to develop suitable fire design rules for LSF wall studs under non-uniform elevated temperature distributions. Applications of the previously developed fire design rules based on AISI design manual and Eurocode 3 Parts 1.2 and 1.3 to LSF wall studs were investigated in detail and new simplified fire design rules based on AS/NZS 4600 and Eurocode 3 Part 1.3 were proposed in the current study with suitable allowances for the interaction effects of compression and bending actions. The accuracy of the proposed fire design rules was verified by using the results from full scale fire tests and extensive numerical studies.
Resumo:
Light Gauge Steel Framing (LSF) walls made of cold-formed and thin-walled steel lipped channel studs with plasterboard linings on both sides are commonly used in commercial, industrial and residential buildings. However, there is limited data about their structural and thermal performance under fire conditions while past research showed contradicting results about the benefits of using cavity insulation. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. In this research 11 full scale tests were conducted on conventional load bearing steel stud walls with and without cavity insulation, and the new composite panel system to study their thermal and structural performance under standard fire conditions. These tests showed that the use of cavity insulation led to inferior fire performance of walls, and provided supporting research data. They demonstrated that the use of insulation externally in a composite panel enhanced the thermal and structural performance of LSF walls and increased their fire resistance rating. This paper presents the details of the LSF wall tests and the thermal and structural performance data and fire resistance rating of load-bearing wall assemblies lined with varying plasterboard-insulation configurations under two different load ratios. Fire test results including the time–temperature and deflection profiles are presented along with the failure times and modes.
Resumo:
Light Gauge Steel Framing (LSF) walls are made of cold-formed, thin-walled steel lipped channel studs with plasterboard linings on both sides. However, these thin-walled steel sections heat up quickly and lose their strength under fire conditions despite the protection provided by plasterboards. A new composite wall panel was recently proposed to improve the fire resistance rating of LSF walls, where an insulation layer was used externally between the plasterboards on both sides of the wall frame instead of using it in the cavity. A research study using both fire tests and numerical studies was undertaken to investigate the structural and thermal behaviour of load bearing LSF walls made of both conventional and the new composite panels under standard fire conditions and to determine their fire resistance rating. This paper presents the details of finite element models of LSF wall studs developed to simulate the structural performance of LSF wall panels under standard fire conditions. Finite element analyses were conducted under both steady and transient state conditions using the time-temperature profiles measured during the fire tests. The developed models were validated using the fire test results of 11 LSF wall panels with various plasterboard/insulation configurations and load ratios. They were able to predict the fire resistance rating within five minutes. The use of accurate numerical models allowed the inclusion of various complex structural and thermal effects such as local buckling, thermal bowing and neutral axis shift that occurred in thin-walled steel studs under non-uniform elevated temperature conditions. Finite element analyses also demonstrated the improvements offered by the new composite panel system over the conventional cavity insulated system.
Resumo:
Traditionally the fire resistance rating of LSF wall systems is based on approximate prescriptive methods developed using limited fire tests. Therefore a detailed research study into the performance of load bearing LSF wall systems under standard fire conditions was undertaken to develop improved fire design rules. It used the extensive fire performance results of eight different LSF wall systems from a series of full scale fire tests and numerical studies for this purpose. The use of previous fire design rules developed for LSF walls subjected to non-uniform elevated temperature distributions based on AISI design manual and Eurocode3 Parts 1.2 and 1.3 was investigated first. New simplified fire design rules based on AS/NZS 4600, North American Specification and Eurocode 3 Part 1.3 were then proposed in this study with suitable allowances for the interaction effects of compression and bending actions. The importance of considering thermal bowing, magnified thermal bowing and neutral axis shift in the fire design was also investigated. A spread sheet based design tool was developed based on the new design rules to predict the failure load ratio versus time and temperature curves for varying LSF wall configurations. The accuracy of the proposed design rules was verified using the test and FEA results for different wall configurations, steel grades, thicknesses and load ratios. This paper presents the details and results of this study including the improved fire design rules for predicting the load capacity of LSF wall studs and the failure times of LSF walls under standard fire conditions.
Resumo:
Background There is growing consensus that a multidisciplinary, comprehensive and standardised process for assessing the fitness of older patients for chemotherapy should be undertaken to determine appropriate cancer treatment. Aim This study tested a model of cancer care for the older patient incorporating Comprehensive Geriatric Assessment (CGA), which aimed to ensure that 'fit' individuals amenable to active treatment were accurately identified; 'vulnerable' patients more suitable for modified or supportive regimens were determined; and 'frail 'individuals who would benefit most from palliative regimens were also identified and offered the appropriate level of care. Methods A consecutive-series n=178 sample of patients >65 years was recruited from a major Australian cancer centre. The following instruments were administered by an oncogeriatric nurse prior to treatment: Vulnerable Elders Survey-13; Cumulative Illness Rating Scale (Geriatric); Malnutrition Screening Tool; Mini-mental State Examination; Geriatric Depression Scale; Barthel Index; and Lawton Instrumental Activities of Daily Living Scale. Scores from these instruments were aggregated to predict patient fitness, vulnerability or frailty for chemotherapy. Physicians provided a concurrent (blinded) prediction of patient fitness, vulnerability or frailty based on their clinical assessment. Data were also collected on actual patient outcomes (eg treatment completed as predicted, treatment reduced) during monthly audits of patient trajectories. Data analysis Data analysis is underway. A sample of 178 is adequate to detect, with 90% power, kappa coefficients of agreement between CGA and physician assessments of K>0.90 ("almost perfect agreement"). Primary endpoints comprise a) whether the nurse-led CGA determination of fit, vulnerable or frail agrees with the oncologist's assessments of fit, vulnerable or frail and b) whether the CGA and physician assessments accurately predict actual patient outcomes. Conclusion An oncogeriatric nurse-led model of care is currently being developed from the results. We conclude with a discussion of the pivotal role of nurses in CGA-based models of care.
Resumo:
Cold–formed Light gauge Steel Frame (LSF) wall systems are increasingly used in low-rise and multi-storey buildings and hence their fire safety has become important in the design of buildings. A composite LSF wall panel system was developed recently, where a thin insulation was sandwiched between two plasterboards to improve the fire performance of LSF walls. Many experimental and numerical studies have been undertaken to investigate the fire performance of non-load bearing LSF wall under standard conditions. However, only limited research has been undertaken to investigate the fire performance of load bearing LSF walls under standard and realistic design fire conditions. Therefore in this research, finite element thermal models of both the conventional load bearing LSF wall panels with cavity insulation and the innovative LSF composite wall panel were developed to simulate their thermal behaviour under standard and realistic design fire conditions. Suitable thermal properties were proposed for plasterboards and insulations based on laboratory tests and available literature. The developed models were then validated by comparing their results with available fire test results of load bearing LSF wall. This paper presents the details of the developed finite element models of load bearing LSF wall panels and the thermal analysis results. It shows that finite element models can be used to simulate the thermal behaviour of load bearing LSF walls with varying configurations of insulations and plasterboards. Failure times of load bearing LSF walls were also predicted based on the results from finite element thermal analyses. Finite element analysis results show that the use of cavity insulation was detrimental to the fire rating of LSF walls while the use of external insulation offered superior thermal protection to them. Effects of realistic design fire conditions are also presented in this paper.
Resumo:
Reports of children and teachers taking transformative social action in schools are becoming rare. This session illustrates how teachers, while feeling the weight of accountability testing in schools, are active agents who can re-imagine literacy pedagogy to change elements of their community. It reports the critical dimensions of a movie-making unit with Year 5 students within a school reform project. The students filmed interviews with people in the local shops to gather lay-knowledge and experiences of the community. The short documentaries challenged stereotypes about what it is like to live in Logan, and critically identified potential improvements to public spaces in the local community. A student panel presented these multimodal texts at a national conference of social activists and community leaders. The report does not valorize or privilege local or lay knowledge over dominant knowledge, but argues that prescribed curriculum should not hinder the capacity for critical consciousness.
Resumo:
Globalised communication in society today is characterised by multimodal forms of meaning making in the context of increased cultural and linguistic diversity. This research paper responds to these imperatives, applying Halliday's (1978, 1994) categories of systemic functional linguistics - representational or ideational, interactive or interpersonal, and compositional or textual meanings. Following the work of Kress (2000), van Leeuwen (Kress and van Leeuwen, 1996), and Jewitt (2006), multimodal semiotic analysis is applied to claymation movies that were collaboratively designed by Year 6 students. The significance of this analysis is the metalanguage for textual work in the kineikonic mode - moving images.
Resumo:
Globalised communication in society today is characterised by multimodal forms of meaning making in a context of increased cultural and linguistic diversity, calling for the teaching of multiliteracies. This transformation requires the development of a new metalanguage or language of description for the burgeoning and hybridised variety of text forms associated with information and multimedia technologies. To continue to teach to a narrow band of print-based genres, grammars, and skills is to ignore the reality of textual practices outside of schools. This paper draws from classroom research in a multiliteracies classroom to provide a multimodal analysis of a claymation movie. The significance of the paper is the synthesis of a multimodal metalanguage for teachers and students to describe the features of work in the kineikonic (moving image) mode.
Resumo:
Despite its potential multiple contributions to sustainable policy objectives, urban transit is generally not widely used by the public in terms of its market share compared to that of automobiles, particularly in affluent societies with low-density urban forms like Australia. Transit service providers need to attract more people to transit by improving transit quality of service. The key to cost-effective transit service improvements lies in accurate evaluation of policy proposals by taking into account their impacts on transit users. If transit providers knew what is more or less important to their customers, they could focus their efforts on optimising customer-oriented service. Policy interventions could also be specified to influence transit users’ travel decisions, with targets of customer satisfaction and broader community welfare. This significance motivates the research into the relationship between urban transit quality of service and its user perception as well as behaviour. This research focused on two dimensions of transit user’s travel behaviour: route choice and access arrival time choice. The study area chosen was a busy urban transit corridor linking Brisbane central business district (CBD) and the St. Lucia campus of The University of Queensland (UQ). This multi-system corridor provided a ‘natural experiment’ for transit users between the CBD and UQ, as they can choose between busway 109 (with grade-separate exclusive right-of-way), ordinary on-street bus 412, and linear fast ferry CityCat on the Brisbane River. The population of interest was set as the attendees to UQ, who travelled from the CBD or from a suburb via the CBD. Two waves of internet-based self-completion questionnaire surveys were conducted to collect data on sampled passengers’ perception of transit service quality and behaviour of using public transit in the study area. The first wave survey is to collect behaviour and attitude data on respondents’ daily transit usage and their direct rating of importance on factors of route-level transit quality of service. A series of statistical analyses is conducted to examine the relationships between transit users’ travel and personal characteristics and their transit usage characteristics. A factor-cluster segmentation procedure is applied to respodents’ importance ratings on service quality variables regarding transit route preference to explore users’ various perspectives to transit quality of service. Based on the perceptions of service quality collected from the second wave survey, a series of quality criteria of the transit routes under study was quantitatively measured, particularly, the travel time reliability in terms of schedule adherence. It was proved that mixed traffic conditions and peak-period effects can affect transit service reliability. Multinomial logit models of transit user’s route choice were estimated using route-level service quality perceptions collected in the second wave survey. Relative importance of service quality factors were derived from choice model’s significant parameter estimates, such as access and egress times, seat availability, and busway system. Interpretations of the parameter estimates were conducted, particularly the equivalent in-vehicle time of access and egress times, and busway in-vehicle time. Market segmentation by trip origin was applied to investigate the difference in magnitude between the parameter estimates of access and egress times. The significant costs of transfer in transit trips were highlighted. These importance ratios were applied back to quality perceptions collected as RP data to compare the satisfaction levels between the service attributes and to generate an action relevance matrix to prioritise attributes for quality improvement. An empirical study on the relationship between average passenger waiting time and transit service characteristics was performed using the service quality perceived. Passenger arrivals for services with long headways (over 15 minutes) were found to be obviously coordinated with scheduled departure times of transit vehicles in order to reduce waiting time. This drove further investigations and modelling innovations in passenger’ access arrival time choice and its relationships with transit service characteristics and average passenger waiting time. Specifically, original contributions were made in formulation of expected waiting time, analysis of the risk-aversion attitude to missing desired service run in the passengers’ access time arrivals’ choice, and extensions of the utility function specification for modelling passenger access arrival distribution, by using complicated expected utility forms and non-linear probability weighting to explicitly accommodate the risk of missing an intended service and passenger’s risk-aversion attitude. Discussions on this research’s contributions to knowledge, its limitations, and recommendations for future research are provided at the concluding section of this thesis.
Resumo:
Few science fiction films have been made in Australia by Australians for Australian audiences, with most of the handful of locally-produced films made since the mid-1990s. Yet there has always been a solid Australian audience for non-Australian science fiction films and a strong international niche audience for the genre. While Australia has provided below-the-line crews and heads of departments (cinematographers, production designers, and so on) for many non-Australian science fiction films produced domestically, few Australian film directors have specialised in the genre. This is somewhat surprising considering that Alex Proyas achieved a degree of international success for his gothic science fiction film Dark City (1998), and George Miller achieved international fame following the worldwide success of Mad Max II (1981). Although the science fiction element of Mad Max II is tenuous – and even more so in the case of the original Mad Max (George Miller, 1979) – Miller is credited with creating a new (sub)genre which incorporates science fiction elements and has been widely imitated internationally: the dystopian, post-apocalyptic movie. Nevertheless, Australia has only produced a small number of science fiction movies. In addition to the above films, key titles include: Mad Max Beyond Thunderdome (George Miller, 1985), Shirley Thompson versus the Aliens (Jim Sharman, 1972), The Time Guardian (Brian Hannant, 1987), The Chain Reaction (Ian Barry, 1980) and, more recently, Knowing (Alex Proyas, 2009), Daybreakers (Michael and Peter Spierig, 2009), and Iron Sky (Timo Vuorensola, 2012).
Resumo:
The dc capacitors voltage unbalancing is the main technical drawback of a diode-clamped multilevel inverter (DCMLI), with more than three levels. A voltage-balancing circuit based on buck–boost chopper connected to the dc link of DCMLI is a reliable and robust solution to this problem. This study presents four different schemes for controlling the chopper circuit to achieve the capacitor voltages equalisation. These can be broadly categorised as single-pulse, multi-pulse and hysteresis band current control schemes. The single-pulse scheme does not involve faster switching actions but need the chopper devices to be rated for higher current. The chopper devices current rating can be kept limited by using the multi-pulse scheme but it involves faster switching actions and slower response. The hysteresis band current control scheme offers faster dynamics, lower current rating of the chopper devices and can nullify the initial voltage imbalance as well. However, it involves much faster switching actions which may not be feasible for some of its applications. Therefore depending on the system requirements and ratings, one of these schemes may be used. The performance and validity of the proposed schemes are confirmed through both simulation and experimental investigations on a prototype five-level diode-clamped inverter.
Resumo:
Background: Medication remains the cornerstone treatment for mental illness. Cognition is one of the strongest predictors of non-adherence. The aim of this preliminary investigation was to examine the association between the Large Allen Cognitive Level Screen (LACLS) and medication adherence among a small sample of mental health service users to determine whether the LACLS has potential as a screening tool for capacity to manage medication regimens. Method: Demographic and clinical information was collected from a small sample of people who had recently accessed community mental health services. Participants then completed the LACLS and the Medication Adherence Rating Scale (MARS) at a single time point. The strength of association between the LACLS and MARS was examined using Spearman rank-order correlation. Results: A strong positive correlation between the LACLS and medication adherence (r = 0.71, p = 0.01) was evident. No participants reported the use of medication aids despite evidence of impaired cognitive functioning. Conclusion: This investigation has provided the first empirical evidence indicating that the LACLS may have utility as a screening instrument for capacity to manage medication adherence among this population. While promising, this finding should be interpreted with caveats given its preliminary nature.
Resumo:
In recent times, fire has become a major disaster in buildings due to the increase in fire loads, as a result of modern furniture and light weight construction. This has caused problems for safe evacuation and rescue activities, and in some instances lead to the collapse of buildings (Lewis, 2008 and Nyman, 2002). Recent research has shown that the actual fire resistance of building elements exposed to building fires can be less than their specified fire resistance rating (Lennon and Moore, 2003, Jones, 2002, Nyman, 2002 and Abecassis-Empis et al. 2008). Conventionally the fire rating of building elements is determined using fire tests based on the standard fire time-temperature curve given in ISO 834. This ISO 834 curve was developed in the early 1900s, where wood was the basic fuel source. In reality, modern buildings make use of thermoplastic materials, synthetic foams and fabrics. These materials are high in calorific values and increase both the speed of fire growth and heat release rate, thus increasing the fire severity beyond that of the standard fire curve. Hence it suggests the need to use realistic fire time-temperature curves in tests. Real building fire temperature profiles depend on the fuel load representing the combustible building contents, ventilation openings and thermal properties of wall lining materials. Fuel load is selected based on a review and suitable realistic fire time-temperature curves were developed. Fire tests were then performed for plasterboard lined light gauge steel framed walls for the developed realistic fire curves. This paper presents the details of the development of suitable realistic building fire curves, and the fire tests using them. It describes the fire performance of tested walls in comparison to the standard fire tests and highlights the differences between them. This research has shown the need to use realistic fire exposures in assessing the fire resistance rating of building elements.