898 resultados para micro total analysis system
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. Methods: This randomized controlled double-blind study included to date 31 patients: the gait signatures of 12 patients with mobile-bearing were compared to the gait signatures of 19 patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. Results: Better relative differences between pre-operative and post-operative 3 months and 6 months KSS (122% vs 34% at 3 months, 138% vs 36% at 6 months) and KSS function (154% vs 8% at 3 months, 183% vs 42% at 6 months) scores were observed for the fixed-bearing compared to the mobile-bearing. The same better improvements for fixed-bearing were also found with the range of knee angles (Affected side: 31% vs -5% at 3 months, 47% vs 5% at 6 months), (Unaffected side: 16% vs 5% at 3 months, 15% vs 6% at 6 months) and peak swing speeds of shank (Affected side: 18% vs -2% at 3 months, 30% vs 4% at 6 months), (Unaffected side: 8% vs -3% at 3 months, 7% vs 4% at 6 months). Conclusions: A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
Introduction: Ankle arthropathy is associated with a decreased motion of the ankle-hindfoot during ambulation. Ankle arthrodesis was shown to result in degeneration of the neighbour joints of the foot. Inversely, total ankle arthroplasty conceptually preserves the adjacent joints because of the residual mobility of the ankle but this has not been demonstrated yet in vivo. It has also been reported that degenerative ankle diseases, and even arthrodesis, do not result in alteration of the knee and hip joints. We present the preliminary results of a new approach of this problem based on ambulatory gait analysis. Patients and Methods: Motion analysis of the lower limbs was performed using a Physilog® (BioAGM, CH) system consisting of three-dimensional (3D) accelerometer and gyroscope, coupled to a magnetic system (Liberty©, Polhemus, USA). Both systems have been validated. Three groups of two patients were included into this pilot study and compared to healthy subjects (controls) during level walking: patients with ankle osteoarthritis (group 1), patients treated by ankle arthrodesis (group 2), patients treated by total ankle prosthesis (group 3). Results: Motion patterns of all analyzed joints over more than 20 gait cycles in each subject were highly repeatable. Motion amplitude of the ankle-hindfoot in control patients was similar to recently reported results. Ankle arthrodesis limited the motion of the ankle-hindfoot in the sagittal and horizontal planes. The prosthetic ankle allowed a more physiologic movement in the sagittal plane only. Ankle arthritis and its treatments did not influence the range of motion of the knee and hip joint during stance phase, excepted for a slight decrease of the hip flexion in groups 1 and 2. Conclusion: The reliability of the system was shown by the repeatability of the consecutive measurements. The results of this preliminary study were similar to those obtained through laboratory gait analysis. However, our system has the advantage to allow ambulatory analysis of 3D kinematics of the lower limbs outside of a gait laboratory and in real life conditions. To our knowledge this is a new concept in the analysis of ankle arthropathy and its treatments. Therefore, there is a potential to address specific questions like the difficult comparison of the benefits of ankle arthroplasty versus arthrodesis. The encouraging results of this pilot study offer the perspective to analyze the consequences of ankle arthropathy and its treatments on the biomechanics of the lower limbs ambulatory, in vivo and in daily life conditions.
Resumo:
Background: Mobile-bearing knee replacements have some theoretical advantages over fixed-bearing devices. However, very few randomized controlled clinical trials have been published to date, and studies showed little clinical and subjective advantages for the mobile-bearing using traditional systems of scoring. The choice of the ideal outcome measure to assess total joint replacement remains a complex issue. However, gait analysis provides objective and quantifying evidences of treatment evaluation. Significant methodological advances are currently made in gait analysis laboratories and ambulatory gait devices are now available. The goal of this study was to provide gait parameters as a new objective method to assess total knee arthroplasty outcome between patients with fixed- and mobile-bearing, using an ambulatory device with minimal sensor configuration. This randomized controlled double-blind study included to date 14 patients: the gait signatures of four patients with mobile-bearing were compared to the gait signatures of nine patients with fixed-bearing pre-operatively and post-operatively at 6 weeks, 3 months and 6 months. Each participant was asked to perform two walking trials of 30m long at his/her preferred speed and to complete a EQ-5D questionnaire, a WOMAC and Knee Society Score (KSS). Lower limbs rotations were measured by four miniature angular rate sensors mounted respectively, on each shank and thigh. A new method for a portable system for gait analysis has been developed with very encouraging results regarding the objective outcome of total knee arthroplasty using mobile- and fixed-bearings.
Resumo:
The aim of this work is to present a new concept, called on-line desorption of dried blood spots (on-line DBS), allowing the direct analysis of a dried blood spot coupled to liquid chromatography mass spectrometry device (LC/MS). The system is based on an inox cell which can receive a blood sample (10 microL) previously spotted on a filter paper. The cell is then integrated into LC/MS system where the analytes are desorbed out of the paper towards a column switching system ensuring the purification and separation of the compounds before their detection on a single quadrupole MS coupled to atmospheric pressure chemical ionisation (APCI) source. The described procedure implies that no pretreatment is necessary in spite the analysis is based on whole blood sample. To ensure the applicability of the concept, saquinavir, imipramine, and verapamil were chosen. Despite the use of a small sampling volume and a single quadrupole detector, on-line DBS allowed the analyses of these three compounds over their therapeutic concentrations from 50 to 500 ng/mL for imipramine and verapamil and from 100 to 1000 ng/mL for saquinavir. Moreover, the method showed good repeatability with relative standard deviation (RSD) lower than 15% based on two levels of concentration (low and high). Function responses were found to be linear over the therapeutic concentration for each compound and were used to determine the concentrations of real patient samples for saquinavir. Comparison of the founded values with those of a validated method used routinely in a reference laboratory showed a good correlation between the two methods. Moreover, good selectivity was observed ensuring that no endogenous or chemical components interfered with the quantitation of the analytes. This work demonstrates the feasibility and applicability of the on-line DBS procedure for bioanalysis.
Resumo:
In the administration, planning, design, and maintenance of road systems, transportation professionals often need to choose between alternatives, justify decisions, evaluate tradeoffs, determine how much to spend, set priorities, assess how well the network meets traveler needs, and communicate the basis for their actions to others. A variety of technical guidelines, tools, and methods have been developed to help with these activities. Such work aids include design criteria guidelines, design exception analysis methods, needs studies, revenue allocation schemes, regional planning guides, designation of minimum standards, sufficiency ratings, management systems, point based systems to determine eligibility for paving, functional classification, and bridge ratings. While such tools play valuable roles, they also manifest a number of deficiencies and are poorly integrated. Design guides tell what solutions MAY be used, they aren't oriented towards helping find which one SHOULD be used. Design exception methods help justify deviation from design guide requirements but omit consideration of important factors. Resource distribution is too often based on dividing up what's available rather than helping determine how much should be spent. Point systems serve well as procedural tools but are employed primarily to justify decisions that have already been made. In addition, the tools aren't very scalable: a system level method of analysis seldom works at the project level and vice versa. In conjunction with the issues cited above, the operation and financing of the road and highway system is often the subject of criticisms that raise fundamental questions: What is the best way to determine how much money should be spent on a city or a county's road network? Is the size and quality of the rural road system appropriate? Is too much or too little money spent on road work? What parts of the system should be upgraded and in what sequence? Do truckers receive a hidden subsidy from other motorists? Do transportation professions evaluate road situations from too narrow of a perspective? In considering the issues and questions the author concluded that it would be of value if one could identify and develop a new method that would overcome the shortcomings of existing methods, be scalable, be capable of being understood by the general public, and utilize a broad viewpoint. After trying out a number of concepts, it appeared that a good approach would be to view the road network as a sub-component of a much larger system that also includes vehicles, people, goods-in-transit, and all the ancillary items needed to make the system function. Highway investment decisions could then be made on the basis of how they affect the total cost of operating the total system. A concept, named the "Total Cost of Transportation" method, was then developed and tested. The concept rests on four key principles: 1) that roads are but one sub-system of a much larger 'Road Based Transportation System', 2) that the size and activity level of the overall system are determined by market forces, 3) that the sum of everything expended, consumed, given up, or permanently reserved in building the system and generating the activity that results from the market forces represents the total cost of transportation, and 4) that the economic purpose of making road improvements is to minimize that total cost. To test the practical value of the theory, a special database and spreadsheet model of Iowa's county road network was developed. This involved creating a physical model to represent the size, characteristics, activity levels, and the rates at which the activities take place, developing a companion economic cost model, then using the two in tandem to explore a variety of issues. Ultimately, the theory and model proved capable of being used in full system, partial system, single segment, project, and general design guide levels of analysis. The method appeared to be capable of remedying many of the existing work method defects and to answer society's transportation questions from a new perspective.
Resumo:
A prior project, HR-388, (which was entitled "Total Cost of Transportation analysis of road and highway issues"), explored the use of a total economic cost basis for evaluation of road based transportation issues. It was conducted as a proof-of-concept effort between 1996 and 2002, with the final report presented in May 2002. TR-477 rebuilt the analytical model using current data, then performed general, system level, county level, and road segment level analyses. The results are presented herein and will be distributed to all county engineers for information and local use.
Resumo:
An assay for the simultaneous analysis of pharmaceutical compounds and their metabolites from micro-whole blood samples (i.e. 5 microL) was developed using an on-line dried blood spot (on-line DBS) device coupled with hydrophilic interaction/reversed-phase (HILIC/RP) LC/MS/MS. Filter paper is directly integrated to the LC device using a homemade inox desorption cell. Without any sample pretreatment, analytes are desorbed from the paper towards an automated system of valves linking a zwitterionic-HILIC column to an RP C18 column. In the same run, the polar fraction is separated by the zwitterionic-HILIC column while the non-polar fraction is eluted on the RP C18. Both fractions are detected by IT-MS operating in full scan mode for the survey scan and in product ion mode for the dependant scan using an ESI source. The procedure was evaluated by the simultaneous qualitative analysis of four probes and their relative phase I and II metabolites spiked in whole blood. In addition, the method was successfully applied to the in vivo monitoring of buprenorphine metabolism after the administration of an intraperitoneal injection of 30 mg/kg on adult female Wistar rat.
Resumo:
AbstractObjective:To define the distal femur rotation pattern in a Brazilian population, correlating such pattern with the one suggested by the arthroplasty instruments, and analyzing the variability of each anatomic parameter.Materials and Methods:A series of 101 magnetic resonance imaging studies were evaluated in the period between April and June 2012. The epidemiological data collection was performed with the aid of the institution's computed imaging system, and the sample included 52 male and 49 female patients. The measurements were made in the axial plane, with subsequent correlation and triangulation with the other plans. The posterior condylar line was used as a reference for angle measurements. Subsequently, the anatomical and surgical transepicondylar axes and the anteroposterior trochlear line were specified. The angles between the reference line and the studied lines were calculated with the aid of the institution's software.Results:The mean angle between the anatomical transepicondylar axis and the posterior condylar line was found to be 6.89°, ranging from 0.25° to 12°. For the surgical transepicondylar axis, the mean value was 2.89°, ranging from –2.23° (internal rotation) to 7.86°, and for the axis perpendicular to the anteroposterior trochlear line, the mean value was 4.77°, ranging from –2.09° to 12.2°.Conclusion:The anatomical transepicondylar angle showed mean values corresponding to the measurement observed in the Caucasian population. The utilized instruments are appropriate, but no anatomical parameter proved to be steady enough to be used in isolation.
Resumo:
BACKGROUND: The use of a robotic surgical system is claimed to allow precise traction and counter-traction, especially in a narrow pelvis. Whether this translates to improvement of the quality of the resected specimen is not yet clear. The aim of the study was to compare the quality of the TME and the short-term oncological outcome between robotic and laparoscopic rectal cancer resections. METHODS: 20 consecutive robotic TME performed in a single institution for rectal cancer (Rob group) were matched 1:2 to 40 laparoscopic resections (Lap group) for gender, body mass index (BMI), and distance from anal verge on rigid proctoscopy. The quality of TME was assessed by 2 blinded and independent pathologists and reported according to international standardized guidelines. RESULTS: Both samples were well matched for gender, BMI (median 25.9 vs. 24.2 kg/m(2), p = 0.24), and level of the tumor (4.1 vs. 4.8 cm, p = 0.20). The quality of the TME was better in the Robotic group (complete TME: 95 vs. 55 %; p = 0.0003, nearly complete TME 5 vs. 37 %; p = 0.04, incomplete TME 0 vs. 8 %, p = 0.09). A trend for lower positive circumferential margin was observed in the Robotic group (10 vs. 25 %, p = 0.1). CONCLUSIONS: These results suggest that robotic-assisted surgery improves the quality of TME for rectal cancer. Whether this translates to better oncological outcome needs to be further investigated.
Resumo:
A flow system coupled to a tungsten coil atomizer in an atomic absorption spectrometer (TCA-AAS) was developed for As(III) determination in waters, by extraction with sodium diethyldithiocarbamate (NaDDTC) as complexing agent, and by sorption of the As(III)-DDTC complex in a micro-column filled with 5 mg C18 reversed phase (10 µL dry sorbent), followed by elution with ethanol. A complete pre-concentration/elution cycle took 208 s, with 30 s sample load time (1.7 mL) and 4 s elution time (71 µL). The interface and software for the synchronous control of two peristaltic pumps (RUN/ STOP), an autosampler arm, seven solenoid valves, one injection valve, the electrothermal atomizer and the spectrometer Read function were constructed. The system was characterized and validated by analytical recovery studies performed both in synthetic solutions and in natural waters. Using a 30 s pre-concentration period, the working curve was linear between 0.25 and 6.0 µg L-1 (r = 0.9976), the retention efficiency was 94±1% (6.0 µg L-1), and the pre-concentration coefficient was 28.9. The characteristic mass was 58 pg, the mean repeatability (expressed as the variation coefficient) was 3.4% (n=5), the detection limit was 0.058 µg L-1 (4.1 pg in 71 µL of eluate injected into the coil), and the mean analytical recovery in natural waters was 92.6 ± 9.5 % (n=15). The procedure is simple, economic, less prone to sample loss and contamination and the useful lifetime of the micro-column was between 200-300 pre-concentration cycles.
Resumo:
À une époque où l'immigration internationale est de plus en plus difficile et sélective, le statut de réfugié constitue un bien public précieux qui permet à certains non-citoyens l'accès et l'appartenance au pays hôte. Reposant sur le jugement discrétionnaire du décideur, le statut de réfugié n’est accordé qu’aux demandeurs qui établissent une crainte bien fondée de persécution en cas de retour dans leur pays d'origine. Au Canada, le plus important tribunal administratif indépendant, la Commission de l'immigration et du statut de réfugié du Canada (CISR), est chargé d’entendre les demandeurs d'asile et de rendre des décisions de statut de réfugié. Cette thèse cherche à comprendre les disparités dans le taux d’octroi du statut de réfugié entre les décideurs de la CISR qui sont politiquement nommés. Au regard du manque de recherches empiriques sur la manière avec laquelle le Canada alloue les possibilités d’entrée et le statut juridique pour les non-citoyens, il était nécessaire de lever le voile sur le fonctionnement de l’administration sur cette question. En explorant la prise de décision relative aux réfugiés à partir d'une perspective de Street Level Bureaucracy Theory (SLBT) et une méthodologie ethnographique qui combine l'observation directe, les entretiens semi-structurés et l'analyse de documents, l'étude a d'abord cherché à comprendre si la variation dans le taux d’octroi du statut était le résultat de différences dans les pratiques et le raisonnement discrétionnaires du décideur et ensuite à retracer les facteurs organisationnels qui alimentent les différences. Dans la lignée des travaux de SLBT qui documentent la façon dont la situation de travail structure la discrétion et l’importance des perceptions individuelles dans la prise de décision, cette étude met en exergue les différences de fond parmi les décideurs concernant les routines de travail, la conception des demandeurs d’asile, et la meilleure façon de mener leur travail. L’analyse montre comment les décideurs appliquent différentes approches lors des audiences, allant de l’interrogatoire rigide à l’entrevue plus flexible. En dépit des contraintes organisationnelles qui pèsent sur les décideurs pour accroître la cohérence et l’efficacité, l’importance de l’évaluation de la crédibilité ainsi que l’invisibilité de l’espace de décision laissent suffisamment de marge pour l’exercice d’un pouvoir discrétionnaire. Même dans les environnements comme les tribunaux administratifs où la surabondance des règles limite fortement la discrétion, la prise de décision est loin d’être synonyme d’adhésion aux principes de neutralité et hiérarchie. La discrétion est plutôt imbriquée dans le contexte de routines d'interaction, de la situation de travail, de l’adhésion aux règles et du droit. Même dans les organisations qui institutionnalisent et uniformisent la formation et communiquent de façon claire leurs demandes aux décideurs, le caractère discrétionnaire de la décision est par la nature difficile, voire impossible, à contrôler et discipliner. Lorsqu'ils sont confrontés à l'ambiguïté des objectifs et aux exigences qui s’opposent à leur pouvoir discrétionnaire, les décideurs réinterprètent la définition de leur travail et banalisent leurs pratiques. Ils formulent une routine de rencontre qui est acceptable sur le plan organisationnel pour évaluer les demandeurs face à eux. Cette thèse montre comment les demandeurs, leurs témoignages et leurs preuves sont traités d’une manière inégale et comment ces traitements se répercutent sur la décision des réfugiés.
Resumo:
Quality related problems have become dominant in the seafood processing industry in Kerala. This has resulted in the rejection of seafood sent from India to many destinations. The latest being the total block listing of seafood companies from India from being exported to Europe and partial block listing by the US. The quality systems prevailed in the seafood industry in India were outdated and no longer in use in the developed world. According to EC Directive discussed above all the seafood factories exporting to European countries have to adopt HACCP. Based on this, EIA has now made HACCP system mandatory in all the seafood processing factories in India. This transformation from a traditional product based inspection system to a process control system requires thorough changes in the various stages of production and quality management. This study is conducted by the author with to study the status of the existing infrastructure and quality control system in the seafood industry in Kerala with reference to the recent developments in the quality concepts in international markets and study the drawbacks, if any, of the existing quality management systems in force in the seafood factories in Kerala for introducing the mandatory HACCP concept. To assess the possibilities of introducing Total Quality Management system in the seafood industry in Kerala in order to effectively adopt the HACCP concept. This is also aimed at improving the quality of the products and productivity of the industry by sustaining the world markets in the long run.
Resumo:
The analytical determination of atmospheric pollutants still presents challenges due to the low-level concentrations (frequently in the mu g m(-3) range) and their variations with sampling site and time In this work a capillary membrane diffusion scrubber (CMDS) was scaled down to match with capillary electrophoresis (CE) a quick separation technique that requires nothing more than some nanoliters of sample and when combined with capacitively coupled contactless conductometric detection (C(4)D) is particularly favorable for ionic species that do not absorb in the UV-vis region like the target analytes formaldehyde formic acid acetic acid and ammonium The CMDS was coaxially assembled inside a PTFE tube and fed with acceptor phase (deionized water for species with a high Henry s constant such as formaldehyde and carboxylic acids or acidic solution for ammonia sampling with equilibrium displacement to the non-volatile ammonium ion) at a low flow rate (8 3 nLs(-1)) while the sample was aspirated through the annular gap of the concentric tubes at 25 mLs(-1) A second unit in all similar to the CMDS was operated as a capillary membrane diffusion emitter (CMDE) generating a gas flow with know concentrations of ammonia for the evaluation of the CMDS The fluids of the system were driven with inexpensive aquarium air pumps and the collected samples were stored in vials cooled by a Peltier element Complete protocols were developed for the analysis in air of NH(3) CH(3)COOH HCOOH and with a derivatization setup CH(2)O by associating the CMDS collection with the determination by CE-C(4)D The ammonia concentrations obtained by electrophoresis were checked against the reference spectrophotometric method based on Berthelot s reaction Sensitivity enhancements of this reference method were achieved by using a modified Berthelot reaction solenoid micro-pumps for liquid propulsion and a long optical path cell based on a liquid core waveguide (LCW) All techniques and methods of this work are in line with the green analytical chemistry trends (C) 2010 Elsevier B V All rights reserved
Resumo:
Direct analysis, with minimal sample pretreatment, of antidepressant drugs, fluoxetine, imipramine, desipramine, amitriptyline, and nortriptyline in biofluids was developed with a total run time of 8 min. The setup consists of two HPLC pumps, injection valve, capillary RAM-ADS-C18 pre-column and a capillary analytical C 18 column connected by means of a six-port valve in backflush mode. Detection was performed with ESI-MS/MS and only 1 mu m of sample was injected. Validation was adequately carried out using FLU-d(5) as internal standard. Calibration curves were constructed under a linear range of 1-250 ng mL(-1) in plasma, being the limit of quantification (LOQ), determined as 1 ng mL(-1), for all the analytes. With the described approach it was possible to reach a quantified mass sensitivity of 0.3 pg for each analyte (equivalent to 1.1-1.3 fmol), translating to a lower sample consumption (in the order of 103 less sample than using conventional methods). (C) 2008 Elsevier B.V. All rights reserved.
Resumo:
Energy efficiency and renewable energy use are two main priorities leading to industrial sustainability nowadays according to European Steel Technology Platform (ESTP). Modernization efforts can be done by industries to improve energy consumptions of the production lines. These days, steel making industrial applications are energy and emission intensive. It was estimated that over the past years, energy consumption and corresponding CO2 generation has increased steadily reaching approximately 338.15 parts per million in august 2010 [1]. These kinds of facts and statistics have introduced a lot of room for improvement in energy efficiency for industrial applications through modernization and use of renewable energy sources such as solar Photovoltaic Systems (PV).The purpose of this thesis work is to make a preliminary design and simulation of the solar photovoltaic system which would attempt to cover the energy demand of the initial part of the pickling line hydraulic system at the SSAB steel plant. For this purpose, the energy consumptions of this hydraulic system would be studied and evaluated and a general analysis of the hydraulic and control components performance would be done which would yield a proper set of guidelines contributing towards future energy savings. The results of the energy efficiency analysis showed that the initial part of the pickling line hydraulic system worked with a low efficiency of 3.3%. Results of general analysis showed that hydraulic accumulators of 650 liter size should be used by the initial part pickling line system in combination with a one pump delivery of 100 l/min. Based on this, one PV system can deliver energy to an AC motor-pump set covering 17.6% of total energy and another PV system can supply a DC hydraulic pump substituting 26.7% of the demand. The first system used 290 m2 area of the roof and was sized as 40 kWp, the second used 109 m2 and was sized as 15.2 kWp. It was concluded that the reason for the low efficiency was the oversized design of the system. Incremental modernization efforts could help to improve the hydraulic system energy efficiency and make the design of the solar photovoltaic system realistically possible. Two types of PV systems where analyzed in the thesis work. A method was found calculating the load simulation sequence based on the energy efficiency studies to help in the PV system simulations. Hydraulic accumulators integrated into the pickling line worked as energy storage when being charged by the PV system as well.