978 resultados para input parameter value recommendation
Resumo:
This paper presents the application of multidimensional scaling (MDS) analysis to data emerging from noninvasive lung function tests, namely the input respiratory impedance. The aim is to obtain a geometrical mapping of the diseases in a 3D space representation, allowing analysis of (dis)similarities between subjects within the same pathology groups, as well as between the various groups. The adult patient groups investigated were healthy, diagnosed chronic obstructive pulmonary disease (COPD) and diagnosed kyphoscoliosis, respectively. The children patient groups were healthy, asthma and cystic fibrosis. The results suggest that MDS can be successfully employed for mapping purposes of restrictive (kyphoscoliosis) and obstructive (COPD) pathologies. Hence, MDS tools can be further examined to define clear limits between pools of patients for clinical classification, and used as a training aid for medical traineeship.
Resumo:
This paper presents a programable perturbation and observation control implementation for a wind generation system and its power electronic converter. The objective of the method in this particular application is to adjust the power delivered to charge a battery to its maximum and allowable value, function of the real values of several parameters and their continuous variation, the most important the wind velocity and the turbine efficiency. Also, to improve the power throughput and to use the turbine and generator marginal zones of operation, an unusual power converter is used, allowing a wide range for the input voltage values. The implemented control is continuously measuring the actual power and looks for a new and powerful operation point. © 2014 IEEE.
Resumo:
The interlaminar fracture toughness in pure mode II (GIIc) of a Carbon-Fibre Reinforced Plastic (CFRP) composite is characterized experimentally and numerically in this work, using the End-Notched Flexure (ENF) fracture characterization test. The value of GIIc was extracted by a new data reduction scheme avoiding the crack length measurement, named Compliance-Based Beam Method (CBBM). This method eliminates the crack measurement errors, which can be non-negligible, and reflect on the accuracy of the fracture energy calculations. Moreover, it accounts for the Fracture Process Zone (FPZ) effects. A numerical study using the Finite Element Method (FEM) and a triangular cohesive damage model, implemented within interface finite elements and based on the indirect use of Fracture Mechanics, was performed to evaluate the suitability of the CBBM to obtain GIIc. This was performed comparing the input values of GIIc in the numerical models with the ones resulting from the application of the CBBM to the numerical load-displacement (P-) curve. In this numerical study, the Compliance Calibration Method (CCM) was also used to extract GIIc, for comparison purposes.
Resumo:
OBJECTIVE To assess the impact of consuming ultra-processed foods on the nutritional dietary profile in Brazil.METHODS Cross-sectional study conducted with data from the module on individual food consumption from the 2008-2009 Pesquisa de Orçamentos Familiares (POF – Brazilian Family Budgets Survey). The sample, which represented the section of the Brazilian population aged 10 years or over, involved 32,898 individuals. Food consumption was evaluated by two 24-hour food records. The consumed food items were classified into three groups: natural or minimally processed, including culinary preparations with these foods used as a base; processed; and ultra-processed.RESULTS The average daily energy consumption per capita was 1,866 kcal, with 69.5% being provided by natural or minimally processed foods, 9.0% by processed foods and 21.5% by ultra-processed food. The nutritional profile of the fraction of ultra-processed food consumption showed higher energy density, higher overall fat content, higher saturated and trans fat, higher levels of free sugar and less fiber, protein, sodium and potassium, when compared to the fraction of consumption related to natural or minimally processed foods. Ultra-processed foods presented generally unfavorable characteristics when compared to processed foods. Greater inclusion of ultra-processed foods in the diet resulted in a general deterioration in the dietary nutritional profile. The indicators of the nutritional dietary profile of Brazilians who consumed less ultra-processed foods, with the exception of sodium, are the stratum of the population closer to international recommendations for a healthy diet.CONCLUSIONS The results from this study highlight the damage to health that is arising based on the observed trend in Brazil of replacing traditional meals, based on natural or minimally processed foods, with ultra-processed foods. These results also support the recommendation of avoiding the consumption of these kinds of foods.
Resumo:
We study some properties of the monotone solutions of the boundary value problem (p(u'))' - cu' + f(u) = 0, u(-infinity) = 0, u(+infinity) = 1, where f is a continuous function, positive in (0, 1) and taking the value zero at 0 and 1, and P may be an increasing homeomorphism of (0, 1) or (0, +infinity) onto [0, +infinity). This problem arises when we look for travelling waves for the reaction diffusion equation partial derivative u/partial derivative t = partial derivative/partial derivative x [p(partial derivative u/partial derivative x)] + f(u) with the parameter c representing the wave speed. A possible model for the nonlinear diffusion is the relativistic curvature operator p(nu)= nu/root 1-nu(2). The same ideas apply when P is given by the one- dimensional p- Laplacian P(v) = |v|(p-2)v. In this case, an advection term is also considered. We show that, as for the classical Fisher- Kolmogorov- Petrovski- Piskounov equations, there is an interval of admissible speeds c and we give characterisations of the critical speed c. We also present some examples of exact solutions. (C) 2014 Elsevier Inc. All rights reserved.
Resumo:
A avaliação de empresas sempre constituiu um tema de elevada reflexão, sendo que vários especialistas tentam encontrar os modelos que melhor se adaptam a situações específicas e para as quais precisam de determinar um valor. No contexto empresarial português começa a ganhar significância a prática da gestão orientada para a criação de valor (Value-Based Management). O conceito de Value-Based Management assistiu a um particular desenvolvimento nos últimos 20 anos como resultado da globalização e desregulamentação dos mercados financeiros, dos avanços nas tecnologias de informação e do aumento da importância dos investidores institucionais. Vários analistas apresentaram evidência de que as empresas que adotam sistemas VBM melhoram o seu desempenho económico em relação a outras de dimensão semelhante no mesmo setor. É neste contexto que o EVA (Economic Value Added) se apresenta como uma métrica de desempenho privilegiada nos processos de controlo das decisões estratégicas tomadas. No presente trabalho pretendemos abordar o conceito da gestão baseada na criação de valor e a sua importância para o acionista, o que implica rever outros modelos de avaliação tradicionais baseados no valor contabilístico. Como métrica de avaliação do desempenho passado da empresa ao nível da criação de valor vamos dar particular importância ao estudo do EVA, fazendo referência à possível correlação entre esta métrica e o MVA (Market Value Added). O objetivo principal é analisar empiricamente a relação do EVA como medida de desempenho associada à criação de valor para os acionistas com a performance da empresa. Com efeito, vamos efetuar um estudo de caso, que vai incidir sobre um grupo empresarial português, referência no seu setor de atividade, o Grupo Galp Energia, cotado na Euronext Lisbon. Pensamos que a crescente prática da gestão baseada na criação de valor nas empresas cotadas em Portugal e a necessidade de aferir os resultados desta, tornam esta investigação pertinente, para além do facto de serem poucos os estudos empíricos à questão da criação de valor e a sua correlação com o valor acrescentado de mercado e com o valor de mercado dos capitais próprios das empresas cotadas em Portugal.
Resumo:
Mestrado em Engenharia Química - Ramo Optimização Energética na Indústria Química
Resumo:
The study of transient dynamical phenomena near bifurcation thresholds has attracted the interest of many researchers due to the relevance of bifurcations in different physical or biological systems. In the context of saddle-node bifurcations, where two or more fixed points collide annihilating each other, it is known that the dynamics can suffer the so-called delayed transition. This phenomenon emerges when the system spends a lot of time before reaching the remaining stable equilibrium, found after the bifurcation, because of the presence of a saddle-remnant in phase space. Some works have analytically tackled this phenomenon, especially in time-continuous dynamical systems, showing that the time delay, tau, scales according to an inverse square-root power law, tau similar to (mu-mu (c) )(-1/2), as the bifurcation parameter mu, is driven further away from its critical value, mu (c) . In this work, we first characterize analytically this scaling law using complex variable techniques for a family of one-dimensional maps, called the normal form for the saddle-node bifurcation. We then apply our general analytic results to a single-species ecological model with harvesting given by a unimodal map, characterizing the delayed transition and the scaling law arising due to the constant of harvesting. For both analyzed systems, we show that the numerical results are in perfect agreement with the analytical solutions we are providing. The procedure presented in this work can be used to characterize the scaling laws of one-dimensional discrete dynamical systems with saddle-node bifurcations.
Resumo:
Twenty patients with prolonged septicemic salmonellosis (Group 1) and 20 with schistosomiasis mansoni (Group 2) were selected for this study. In both groups, the Widal test was done using antigens of the sample Ty 901 (S. typhi). The test was also applied in 6 group 1 patients with antigens prepared from salmonellae isolated from these patients (autoantigens). Titres over 1:200 were considered significant. Ten group 1 patients (50%) were positive for antigen "H" and 5 (25%) were positive for antigen "O". Three patients with negative "H" and "O" reactions became positive with high titres when using autoantigens. Two other cases maintained the same positive titres and one case showed a fourfold increase in titres when the test was done 'with antigens of the Salmonella isolated. The Widal test was positive in most patients infected with group D Salmonellae. Considering titres above 1:200, all cases were negative in Group 2. The authors conclude that the Widal test has low positivity in prolonged septicemic salmonellosis. The test may be valuable in the diagnosis of this disease when using S. paratyphi "A" and "B" antigens and a mixture of Salmonella antigens taken from other groups.
Resumo:
5th Portuguese Conference on Automatic Control, September, 5-7, 2002, Aveiro, Portugal
Resumo:
Dissertação apresentada para obtenção do grau de Doutor em Matemática na especialidade de Equações Diferenciais, pela Universidade Nova de Lisboa,Faculdade de Ciências e Tecnologia
Resumo:
Mestrado em Engenharia Química
Resumo:
O objectivo principal deste trabalho é a realização de uma auditoria, à qualidade do ar interior (QAI), a um edifício de serviços – COCIGA, SA, tendo como base o Regulamento dos Sistemas Energéticos de Climatização dos Edifícios (RSECE). A auditoria QAI implica a medição de vários parâmetros físicos, químicos, microbiológicos e também a inspecção aos componentes do sistema de climatização com a finalidade de averiguar o seu estado de limpeza e manutenção. Assim, foram seleccionados 3 espaços, para a realização de amostragens designados por Comercial - Produtos, AVAC e Mezaninne das oficinas, nos quais foi efectuada a medição de diversos parâmetros, de acordo com as imposições do RSECE, utilizando medidores portáteis ou recorrendo a métodos analíticos. Relativamente aos parâmetros físicos, registaram-se valores de temperatura, para os três espaços estudados, entre os 21 e os 24 ºC e valores médios de humidade relativa de cerca de 50 %. Outro parâmetro medido, e de grande importância para garantir o conforto dos ocupantes, foi a velocidade do ar nos postos de trabalho. De acordo com o RSECE este valor não deve ser superior a 0,2 m/s, o que se verificou em todos os pontos medidos. O último parâmetro físico medido foi a concentração de partículas (PM10) tendo-se obtido valores de cerca de 23 μg/m3ar, valor bastante inferior ao máximo permitido pelo RSECE (150 μg/m3ar). Também no que diz respeito aos parâmetros químicos, ou seja, CO2, CO, formaldeído e ozono, não se verificaram valores superiores aos regulamentares. No caso do CO2, o valor máximo encontrado, nestes três espaços, foi de 745 ppm na Mezaninne das Oficinas e para o CO, na zona AVAC com uma concentração de 0,73 ppm. A medição do formaldeído registou valores perto dos 45 μg/m3ar e o ozono apenas foi detectado, em concentração muito reduzida, na zona Comercial – Produtos. Por fim, as concentrações de bactérias e fungos, de acordo com o RSECE, não devem ultrapassar as 500 UFC/m3ar (parâmetros microbiológicos). Em qualquer dos espaços, os valores medidos foram inferiores ao máximo legal, não ultrapassando as 50 UFC/m3ar. Da avaliação do projecto AVAC, e através da medição dos caudais de insuflação/ extracção em cada zona, concluiu-se que os seus valores não estão de acordo com os valores do projecto inicial que poderá ser imputada a uma insuficiência no funcionamento do sistema detectada na altura das medições. No que diz respeito ao estado de limpeza do sistema AVAC, apenas foi possível inspeccionar as unidades de tratamento de ar, tendo-se constatado que se encontram em boas condições. Ou seja, do ponto de vista do RSECE, e referindo-nos apenas à vertente da Qualidade do Ar Interior, o edifício em causa, cumpre todos os limites impostos para as concentrações de poluentes mas, apresenta algumas deficiências no que respeita aos caudais de ar novo insuflados em cada espaço.
Resumo:
A serologic study was undertaken in a group of 43 patients with active paracoccidioidomycosis who were treated in the same form (ketoconazole), for identical periods of time (6 months), and folio wed-up for various periods posttherapy. The tests employed were agar gel immunodiffusion (AGID) and complement fixation (FC). Also studied were 50 sera from patients with proven histoplasmosis and pulmonary aspergilloma, 30 patients with culturaly proven tuberculosis as well as 92 specimens from healthy individuals, residents in the endemic area for paracoccidioidomycosis. A single lot of yeast filtrate antigen was used throughout the study. The value of each test was measured according to GALEN and GAMBINO6. Both tests were highly sensitive, 89 and 93% respectively. Regarding their specificity, the AGID was totally specific while the CF exhibited 96.6% and 97% specificity in front of tuberculosis patients and healthy individuals respectively and 82% in comparison with patients with other mycoses. The concept of predictive value, that is, the certainty one has in accepting a positive test as diagnostic of paracoccidioidomycosis, favored the AGID procedure (100%) over the CF test. The latter could sort out with 93% certainty a patient with paracoccidioidomycosis among a group of healthy individuals and with 97.5% in the case of TB patients; when the group in question was composed by individuals with other deep mycoses, such certainty was lower (81%). The above results indicate that both the AGID and the CF tests furnish results of high confidence; one should not relay, however, in the CF alone as a means to establish the specific diagnosis of paracoccidioidomycosis.
Resumo:
The main purpose of this work was the development of procedures for the simulation of atmospheric ows over complex terrain, using OpenFOAM. For this aim, tools and procedures were developed apart from this code for the preprocessing and data extraction, which were thereafter applied in the simulation of a real case. For the generation of the computational domain, a systematic method able to translate the terrain elevation model to a native OpenFOAM format (blockMeshDict) was developed. The outcome was a structured mesh, in which the user has the ability to de ne the number of control volumes and its dimensions. With this procedure, the di culties of case set up and the high computation computational e ort reported in literature associated to the use of snappyHexMesh, the OpenFOAM resource explored until then for the accomplishment of this task, were considered to be overwhelmed. Developed procedures for the generation of boundary conditions allowed for the automatic creation of idealized inlet vertical pro les, de nition of wall functions boundary conditions and the calculation of internal eld rst guesses for the iterative solution process, having as input experimental data supplied by the user. The applicability of the generated boundary conditions was limited to the simulation of turbulent, steady-state, incompressible and neutrally strati ed atmospheric ows, always recurring to RaNS (Reynolds-averaged Navier-Stokes) models. For the modelling of terrain roughness, the developed procedure allowed to the user the de nition of idealized conditions, like an uniform aerodynamic roughness length or making its value variable as a function of topography characteristic values, or the using of real site data, and it was complemented by the development of techniques for the visual inspection of generated roughness maps. The absence and the non inclusion of a forest canopy model limited the applicability of this procedure to low aerodynamic roughness lengths. The developed tools and procedures were then applied in the simulation of a neutrally strati ed atmospheric ow over the Askervein hill. In the performed simulations was evaluated the solution sensibility to di erent convection schemes, mesh dimensions, ground roughness and formulations of the k - ε and k - ω models. When compared to experimental data, calculated values showed a good agreement of speed-up in hill top and lee side, with a relative error of less than 10% at a height of 10 m above ground level. Turbulent kinetic energy was considered to be well simulated in the hill windward and hill top, and grossly predicted in the lee side, where a zone of ow separation was also identi ed. Despite the need of more work to evaluate the importance of the downstream recirculation zone in the quality of gathered results, the agreement between the calculated and experimental values and the OpenFOAM sensibility to the tested parameters were considered to be generally in line with the simulations presented in the reviewed bibliographic sources.