819 resultados para gonadosomatic index


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. This paper is a report of a study to test the proposed factor structure of the Index of Sources of Stress in Nursing Students. Background. Research across many countries has identified a number of sources of distress in nursing students but little attempt has been made to understand and measure sources of eustress or those stressors likely to enhance performance and well-being. The Index of Sources of Stress in Nursing Students was developed to do this. Exploratory factor analysis suggested a three-factor structure, the factors being labelled: learning and teaching; placement-related and course organization. It is important, however, to subject the instrument to confirmatory factor analysis as a further test of construct validity. Method. A convenience sample of final year nursing students (n = 176) was surveyed in one university in Northern Ireland in 2007. The Index of Sources of Stress in Nursing Students, which measures sources of stress likely to contribute to distress and eustress, was completed electronically. The LISREL programme was used to carry out the confirmatory factor analysis and test the factor structure suggested in the exploratory analysis. Findings. The proposed factor structure for the items measuring ‘Uplifts’ proved to be a good fit to the data and the proposed factor structure for the items measuring ‘Hassles’ showed adequate fit. Conclusion. In nursing programmes adopting the academic model and combining university-based learning with placement experience, this instrument can be used to help identify the sources of stress or course demands that students rate as distressing and those that help them to achieve. The validity of the ISSN could be further evaluated in other education settings.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Refractive index determination of minerals and gems often requires their immersion in fluids with the same refractive index. However, these natural materials frequently have refractive indices above the ranges of common organic solvents. Most available high refractive index immersion materials are solid at room temperature, toxic, noxious, corrosive, carcinogenic, or any combination thereof. Since the physical properties of ionic liquids can be tuned by varying the cation and/or anion, we have developed immersion fluids for mineralogical studies which are relatively benign. We report here the syntheses of a range of ionic liquids ( many novel) based on the 1-alkyl-3-methylimidazolium cation, which all have refractive indices greater than 1.4, and can be used as immersion fluids for optical mineralogy studies. We further show that for a series of ionic liquids with the same anion, the refractive indices can be adjusted by systematic changes in the cation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We study two-dimensional Banach spaces with polynomial numerical indices equal to zero.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The development of a reflective, gold-coated long-period grating-based sensor for the measurement of chloride ions in solution is discussed. The sensor scheme is based around a long-period fiber grating (LPG)-based Michelson interferometer where the sensor was calibrated and evaluated in the laboratory using sodium chloride solutions, over a wide range of concentrations, from 0.01 to 4.00 M. The grating response creates shifts in the spectral characteristic of the interferometer, formed using the LPG and a reflective surface on the distal end of the fiber, due to the change of refracting index of the solution surrounding it. It was found that the sensitivity of the device could be enhanced over that obtained from a bare fiber by coating the LPG-based interferometer with gold nanoparticles and the results of a cross-comparison of performance were obtained and details discussed. The approach will be explored as a basis to create a portable, low-power device, developed with the potential for installation in concrete structures to determine the ingress of chloride ions, operating through monitoring the refractive index change.