999 resultados para gamma detection
Resumo:
A label-free DNA aptamer-based impedance biosensor for the detection of E. coli outer membrane proteins (OMPs) was developed. Two single stranded DNA sequences were tested as recognition elements and compared. The aptamer capture probes were immobilized, with and without 6-mercapto-1-hexanol (MCH) on a gold electrode. Each step of the modification process was characterized by Faradaic impedance spectroscopy (FIS). A linear relationship between the electron-transfer resistance (Ret) and E. coli OMPs concentration was demonstrated in a dynamic detection range of 1 × 10−7–2 × 10−6 M. Moreover, the aptasensor showed selectivity despite the presence of other possible water contaminates and could be regenerated under low pH condition. The developed biosensor shows great potential to be incorporated in a biochip and used for in situ detection of E. coli OMPs in water samples.
Resumo:
Using low cost portable devices that enable a single analytical step for screening environmental contaminants is today a demanding issue. This concept is here tried out by recycling screen-printed electrodes that were to be disposed of and by choosing as sensory element a low cost material offering specific response for an environmental contaminant. Microcystins (MCs) were used as target analyte, for being dangerous toxins produced by cyanobacteria released into water bodies. The sensory element was a plastic antibody designed by surface imprinting with carefully selected monomers to ensure a specific response. These were designed on the wall of carbon nanotubes, taking advantage of their exceptional electrical properties. The stereochemical ability of the sensory material to detect MCs was checked by preparing blank materials where the imprinting stage was made without the template molecule. The novel sensory material for MCs was introduced in a polymeric matrix and evaluated against potentiometric measurements. Nernstian response was observed from 7.24 × 10−10 to 1.28 × 10−9 M in buffer solution (10 mM HEPES, 150 mM NaCl, pH 6.6), with average slopes of −62 mVdecade−1 and detection capabilities below 1 nM. The blank materials were unable to provide a linear response against log(concentration), showing only a slight potential change towards more positive potentials with increasing concentrations (while that ofthe plastic antibodies moved to more negative values), with a maximum rate of +33 mVdecade−1. The sensors presented good selectivity towards sulphate, iron and ammonium ions, and also chloroform and tetrachloroethylene (TCE) and fast response (<20 s). This concept was successfully tested on the analysis of spiked environmental water samples. The sensors were further applied onto recycled chips, comprehending one site for the reference electrode and two sites for different selective membranes, in a biparametric approach for “in situ” analysis.
Resumo:
A novel surface molecularly-imprinted (MI) material to detect myoglobin (Myo) using gold screen printed electrodes (SPE) was developed. The sensitive detection was carry out by introducing a carboxylic polyvinyl chloride (PVC-COOH) layer on gold SPE surface. Myo was attached to the surface of gold SPE/PVC-COOH and the vacant spaces around it were filled by polymerizing acrylamide and N,N-methylenebisacrylamide (cross-linker). This polymerization was initiated by ammonium persulphate. After removing the template, the obtained material was able to rebind Myo and discriminate it among other interfering species. Various characterization techniques including electrochemical impedance spectroscopy (EIS) and cyclic voltammetry (CV) confirmed the surface modification. This sensor seemed a promising tool for screening Myo in point-of-care.
Resumo:
Microcystin-LR (MC-LR) is a dangerous toxin found in environmental waters, quantified by high performance liquid chromatography and/or enzyme-linked immunosorbent assays. Quick, low cost and on-site analysis is thus required to ensure human safety and wide screening programs. This work proposes label-free potentiometric sensors made of solid-contact electrodes coated with a surface imprinted polymer on the surface of Multi-Walled Carbon NanoTubes (CNTs) incorporated in a polyvinyl chloride membrane. The imprinting effect was checked by using non-imprinted materials. The MC-LR sensitive sensors were evaluated, characterized and applied successfully in spiked environmental waters. The presented method offered the advantages of low cost, portability, easy operation and suitability for adaptation to flow methods.
Resumo:
A novel optical disposable probe for screening fluoroquinolones in fish farming waters is presented, having Norfloxacin (NFX) as target compound. The colorimetric reaction takes place in the solid/liquid interface consisting of a plasticized PVC layer carrying the colorimetric reagent and the sample solution. NFX solutions dropped on top of this solid-sensory surface provided a colour change from light yellow to dark orange. Several metals were tested as colorimetric reagents and Fe(III) was selected. The main parameters affecting the obtained colour were assessed and optimised in both liquid and solid phases. The corresponding studies were conducted by visible spectrophotometry and digital image acquisition. The three coordinates of the HSL model system of the collected image (Hue, Saturation and Lightness) were obtained by simple image management (enabled in any computer). The analytical response of the optimised solid-state optical probe against concentration was tested for several mathematical transformations of the colour coordinates. Linear behaviour was observed for logarithm NFX concentration against Hue+Lightness. Under this condition, the sensor exhibited a limit of detection below 50 μM (corresponding to about 16 mg/mL). Visual inspection also enabled semi-quantitative information. The selectivity was ensured against drugs from other chemical groups than fluoroquinolones. Finally, similar procedure was used to prepare an array of sensors for NFX, consisting on different metal species. Cu(II), Mn(II) and aluminon were selected for this purpose. The sensor array was used to detect NFX in aquaculture water, without any prior sample manipulation.
Resumo:
Strongyloides ratti larval extract was used for the standardization of ELISA to detect genus-specific IgE in human strongyloidiasis. Forty serum samples from monoinfected patients shedding S. stercoralis larvae (Group I), 40 from patients with other intestinal parasites (Group II), and 40 from copronegative healthy subjects (Group III) were analyzed. Genus-specific IgE levels (ELISA Index: EI) were significantly higher in the group I (EI = 1.43) than groups II (EI = 0.70) and III (EI = 0.71), showing positivity rates of 55%, 2.5% and 0%, respectively. Similarly, sera from copropositive patients had significantly higher levels of total IgE (866 IU/mL) as compared to those from group II (302 IU/mL) and III (143 IU/mL). A significant positive correlation was found between levels of Strongyloides specific-IgE and total IgE in sera from patients with strongyloidiasis. In conclusion, S. ratti heterologous extract showed to be a useful tool for detecting genus-specific IgE by ELISA, contributing for a better characterization of the immune response profile in human strongyloidiasis.
Resumo:
The formalin-Tween sedimentation method was compared with the formalin-ether sedimentation for parasitic detection. Of a total 297 fecal specimens examined, 72.1% were positive. The formalin-tween technique was effective for ascertaining helminths, particularly Ascaris lumbricoides, Trichuris trichiura and hookworm eggs; however it has less capability for protozoa detection. This method is simple, inexpensive, less time consuming and highly sensitive when detecting the parasitic infection, particularly when focusing on helminth eggs.
Resumo:
Chromoblastomycosis (CBM) is a chronic subcutaneous infection caused by several dematiaceous fungi. The most commonly etiological agent found in Brazil is Fonsecaea pedrosoi, which appears as thick walled, brownish colored cells with transverse and longitudinal division in the lesions, called "muriform cells". This disease is found worldwide but countries like Madagascar and Brazil have highest incidence. Diagnosis is made by clinical, direct and histopathologic examination and culture of specimens. Serological tests have been used to identify specific antibodies against Fonsecaea pedrosoi antigens, as well as immunotechniques have been used for CBM serological identification and diagnosis. In the present study double immunodiffusion (DID), counterimmunoelectrophoresis (CIE) and immunoenzymatic test (ELISA) have been used to evaluate humoral immune response in patients with CBM caused by F. pedrosoi. Metabolic antigen was used for immunoprecipitation tests (DID and CIE) while somatic antigen for ELISA. Our results demonstrated 53% sensitivity and 96% specificity for DID, while CIE presented 68% sensitivity and 90.5% specificity. ELISA demonstrated 78% sensibility and 83% specificity. Serological tests can be a useful tool to study different aspects of CBM, such as helping differential diagnosis, when culture of the pathogenic agent is impossible.
Resumo:
Cyanobacteria deteriorate the water quality and are responsible for emerging outbreaks and epidemics causing harmful diseases in Humans and animals because of their toxins. Microcystin-LR (MCT) is one of the most relevant cyanotoxin, being the most widely studied hepatotoxin. For safety purposes, the World Health Organization recommends a maximum value of 1 μg L−1 of MCT in drinking water. Therefore, there is a great demand for remote and real-time sensing techniques to detect and quantify MCT. In this work a Fabry–Pérot sensing probe based on an optical fibre tip coated with a MCT selective thin film is presented. The membranes were developed by imprinting MCT in a sol–gel matrix that was applied over the tip of the fibre by dip coating. The imprinting effect was obtained by curing the sol–gel membrane, prepared with (3-aminopropyl) trimethoxysilane (APTMS), diphenyl-dimethoxysilane (DPDMS), tetraethoxysilane (TEOS), in the presence of MCT. The imprinting effect was tested by preparing a similar membrane without template. In general, the fibre Fabry–Pérot with a Molecular Imprinted Polymer (MIP) sensor showed low thermal effect, thus avoiding the need of temperature control in field applications. It presented a linear response to MCT concentration within 0.3–1.4 μg L−1 with a sensitivity of −12.4 ± 0.7 nm L μg−1. The corresponding Non-Imprinted Polymer (NIP) displayed linear behaviour for the same MCT concentration range, but with much less sensitivity, of −5.9 ± 0.2 nm L μg−1. The method shows excellent selectivity for MCT against other species co-existing with the analyte in environmental waters. It was successfully applied to the determination of MCT in contaminated samples. The main advantages of the proposed optical sensor include high sensitivity and specificity, low-cost, robustness, easy preparation and preservation.
Resumo:
6th Graduate Student Symposium on Molecular Imprinting
Resumo:
Oysters are edible organisms that are often ingested partially cooked or even raw, presenting therefore a very high risk to the consumers' health, especially in tropical regions. The presence of Vibrio cholerae and Vibrio parahaemolyticus in oysters sampled at an estuary in the Brazilian northeastern region was studied, with 300 oysters tested through an 8-months period. The salinity of the water at the sampling point varied between 3% and 27. V. cholerae was the most frequently detected species (33.3% of the samples), and of the 22 V. cholerae isolates, 20 were identified as non-O1/non-O139, with two of the colonies presenting a rough surface and most of remaining ones belonging to the Heiberg II fermentation group. V. parahaemolyticus was isolated from just one of the samples. Other bacteria such as Providencia spp., Klebsiella spp. and Morganella morganii were also isolated.
Resumo:
Background: A new method for determining serum specific IgE (IMMULITE“ 2000 3gAllergy) has recently become available. Objective: To evaluate the clinical performance of IMMULITE 2000 in the diagnosis of cow’s milk allergy compared with that of UniCAP“. Additionally, we verified the behavior of both methods at two diagnostic decision points proposed by other authors. Methods: The study population consisted of 31 children with cow’s milk allergy (group A) and a control group of 19 atopic children without food allergy(group B). A blood sample from each child was tested using both methods and the results were compared. Results: In group A, the values for cow’s milk IgE ranged from 0.35 kU/L (the lowest common detection limit) to above 100 kU/L. In group B, the values were less than 1.1 kU/L for IMMULITE 2000 and less than 1.6 kU/L for UniCAP. An agreement of 90 % in IgE classes was obtained. Both methods demonstrated exactly the same diagnostic performance(sensitivity: 100 %; specificity: 78.9 %; negative predictive value: 100%; positive predictive value: 84.6%;efficiency: 90.2 %). The evaluation of the two methods at the two different decision points proposed in the literature showed a better positive predictive value with UniCAP, but we obtained equivalent performance with IMMULITE 2000 by choosing higher cutoff values. Conclusions: We conclude that IMMULITE 2000 is as effective as UniCAP in the diagnosis of cow’s milk allergy. Both methods can be used to obtain site-specific decision points that are population, age and disease dependent.
Resumo:
This work presents the integration of obstacle detection and analysis capabilities in a coherent and advanced C&C framework allowing mixed-mode control in unmanned surface systems. The collision avoidance work has been successfully integrated in an operational autonomous surface vehicle and demonstrated in real operational conditions. We present the collision avoidance system, the ROAZ autonomous surface vehicle and the results obtained at sea tests. Limitations of current COTS radar systems are also discussed and further research directions are proposed towards the development and integration of advanced collision avoidance systems taking in account the different requirements in unmanned surface vehicles.
Resumo:
In this work a forest fire detection solution using small autonomous aerial vehicles is proposed. The FALCOS unmanned aerial vehicle developed for remote-monitoring purposes is described. This is a small size UAV with onboard vision processing and autonomous flight capabilities. A set of custom developed navigation sensors was developed for the vehicle. Fire detection is performed through the use of low cost digital cameras and near-infrared sensors. Test results for navigation and ignition detection in real scenario are presented.