874 resultados para fractures fixation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Stereology is an essential method for quantitative analysis of lung structure. Adequate fixation is a prerequisite for stereological analysis to avoid bias in pulmonary tissue, dimensions and structural details. We present a technique for in situ fixation of large animal lungs for stereological analysis, based on closed loop perfusion fixation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To clarify the occurrence, causes, severity, and predictors of concomitant injuries in pediatric patients with facial fractures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pulmonary fat embolism (PFE) is frequently encountered in blunt trauma. The clinical manifestation ranges from no impairment in light cases to death due to right-sided heart failure or hypoxaemia in severe cases. Occasionally, pulmonary fat embolism can give rise to a fat embolism syndrome (FES), which is marked by multiorgan failure, respiratory disorders, petechiae and often death. It is well known that fractures of long bones can lead to PFE. Several authors have argued that PFE can arise due to mere soft tissue injury in the absence of fractures, a claim other authors disagree upon. In this study, we retrospectively examined 50 victims of blunt trauma with regard to grade and extent of fractures and crushing of subcutaneous fatty tissue and presence and severity of PFE. Our results indicate that PFE can arise due to mere crushing of subcutaneous fat and that the fracture grade correlated well with PFE severity (p = 0.011). The correlation between PFE and the fracture severity (body regions affected by fractures and fracture grade) showed a lesser significant correlation (p = 0.170). The survival time (p = 0.567), the amount of body regions affected by fat crushing (p = 0.336) and the fat crush grade (p = 0.485) did not correlate with the PFE grade, nor did the amount of body regions affected by fractures. These results may have clinical implications for the assessment of a possible FES development, as, if the risk of a PFE is known, preventive steps can be taken.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

In Switzerland, the number, incidence, and cost of acute hospitalizations for major osteoporotic fractures (MOF) and major cardiovascular events (MCE) increased in both women and men between 2000 and 2008, although the mean length of stay (LOS) was significantly reduced. Similar trend patterns were observed for hip fractures and strokes (decrease) and nonhip fractures and acute myocardial infarctions (increase).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The FREEDOM (Fracture REduction Evaluation of Denosumab in Osteoporosis every 6 Months) trial showed denosumab significantly reduced the risk of fractures in postmenopausal women with osteoporosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

FRAX-based cost-effective intervention thresholds in the Swiss setting were determined. Assuming a willingness to pay at 2× Gross Domestic Product per capita, an intervention aimed at reducing fracture risk in women and men with a 10-year probability for a major osteoporotic fracture at or above 15% is cost-effective.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

There are two main types of bone in the human body, trabecular and cortical bone. Cortical bone is primarily found on the outer surface of most bones in the body while trabecular bone is found in vertebrae and at the end of long bones (Ross 2007). Osteoporosis is a condition that compromises the structural integrity of trabecular bone, greatly reducing the ability of the bone to absorb energy from falls. The current method for diagnosing osteoporosis and predicting fracture risk is measurement of bone mineral density. Limitations of this method include dependence on the bone density measurement device and dependence on type of test and measurement location (Rubin 2005). Each year there are approximately 250,000 hip fractures in the United States due to osteoporosis (Kleerekoper 2006). Currently, the most common method for repairing a hip fracture is a hip fixation surgery. During surgery, a temporary guide wire is inserted to guide the permanent screw into place and then removed. It is believed that directly measuring this screw pullout force may result in a better assessment of bone quality than current indirect measurement techniques (T. Bowen 2008-2010, pers. comm.). The objective of this project is to design a device that can measure the force required to extract this guide wire. It is believed that this would give the surgeon a direct, quantitative measurement of bone quality at the site of the fixation. A first generation device was designed by a Bucknell Biomedical Engineering Senior Design team during the 2008- 2009 Academic Year. The first step of this project was to examine the device, conduct a thorough design analysis, and brainstorm new concepts. The concept selected uses a translational screw to extract the guide wire. The device was fabricated and underwent validation testing to ensure that the device was functional and met the required engineering specifications. Two tests were conducted, one to test the functionality of the device by testing if the device gave repeatable results, and the other to test the sensitivity of the device to misalignment. Guide wires were extracted from 3 materials, low density polyethylene, ultra high molecular weight polyethylene, and polypropylene and the force of extraction was measured. During testing, it was discovered that the spring in the device did not have a high enough spring constant to reach the high forces necessary for extracting the wires without excessive deflection of the spring. The test procedure was modified slightly so the wires were not fully threaded into the material. The testing results indicate that there is significant variation in the screw pullout force, up to 30% of the average value. This significant variation was attributed to problems in the testing and data collection, and a revised set of tests was proposed to better evaluate the performance of the device. The fabricated device is a fully-functioning prototype and further refinements and testing of the device may lead to a 3rd generation version capable of measuring the screw pullout force during hip fixation surgery.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

We describe a case of a fatal speed flying accident in which the victim was electrocuted, burned and fell from a great height. Post-mortem imaging revealed acute appearing fractures on CT, without bone marrow oedema on MRI. Based on the known clinical imaging findings of bone marrow oedema in acute fractures, we concluded that the speed flyer died from electrocution rather than the fall and that the fractures occurred post-mortem. Radiological imaging augmented the reconstruction of the peri-mortem events. Further research is needed to assess whether bone marrow oedema in acute fractures is a reliable vital sign.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following Lichtenstein hernia repair, up to 25% of patients experience prolonged postoperative and chronic pain as well as discomfort in the groin. One of the underlying causes of these complaints are the compression or irritation of nerves by the sutures used to fixate the mesh. We compared the level and rate of chronic pain in patients operated with the classical Lichtenstein technique fixated by sutures to patients with sutureless mesh fixation technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

For nonsurgical treatment of fractures of the proximal phalanges of the triphalangeal fingers, different dynamic casts have been described. The main principle behind these casts is advancement and tightening of the extensor hood, caused by a combination of blocking the metacarpophalangeal joints in flexion and actively flexing the proximal interphalangeal joints. In contrast to established treatment protocols using functional forearm casts, the Lucerne cast allows for free mobilization of the wrist joint. The purpose of the current multicenter study was to compare the results of conservative, functional treatment using 2 different methods, either a forearm cast or a Lucerne cast.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The purpose of our prospective study was to document the clinical and radiological results of conservative-functional treatment of extraarticular proximal phalangeal fractures without immobilisation of the wrist.

Relevância:

20.00% 20.00%

Publicador: