982 resultados para femtosecond optical heterodyne detection of optical Kerr


Relevância:

100.00% 100.00%

Publicador:

Resumo:

The misuse of human growth hormone (hGH) in sport is deemed to be unethical and dangerous because of various adverse effects. Thus, it has been added to the International Olympic Committee list of banned substances. Until now, the very low concentration of hGH in the urine made its measurement difficult using classical methodology. Indeed, for routine diagnosis, only plasma measurements were available. However, unlike blood samples, urine is generally provided in abundant quantities and is, at present, the only body fluid allowed to be analysed in sport doping controls. A recently developed enzyme-linked immunosorbent assay (Norditest) makes it now possible, without any extraction, to measure urinary hGH (u-hGH) in a dynamic range of 2-50 ng hGH/l. In our protocol, untreated and treated non-athlete volunteers were followed. Some of them received therapeutical doses of recombinant hGH (Norditropin) for one week either intramuscularly (three increasing doses) or subcutaneously (12 i.u. every day). The u-hGH excretion after treatment showed dramatic increases of 50-100 times the basal values and returned to almost the mean normal level after 24 h. u-hGH was also measured in samples provided by the anti-doping controls at major and minor competitions. Depending on the type of efforts made during the competition, the hGH concentration in urine was dramatically increased. Insulin-like growth factor binding proteins and beta 2-microglobulins in urine and/or in blood could be necessary for the correct investigation of any hGH doping test procedure.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Coagulase-negative Staphylococcus spp. was considered nonpathogenic until the emergence of multiresistance and the demonstration of their participation as infectious agents. In Brazil, oxacillin resistance may be present in over 80% of isolates, and the Clinical and Laboratory Standards Institute standardized a disk-diffusion method to predict this resistance in Staphylococcus. The aim of this study was to evaluate the variability among commercial disks of oxacillin (1 µg) and cefoxitin (30 µg) widely used in clinical laboratories of microbiology, compared with mecA gene and minimum inhibitory concentration (MIC) of oxacillin. The use of oxacillin and cefoxitin disks simultaneously allowed the detection of important differences, particularly, in less frequent species such as S. cohnii, S. haemolyticus, S. saprophyticus, and S. sciuri. Disks of cefoxitin of the brand 2 displayed good correlation with the mecA gene (98.7%) and oxacillin MIC (97.8%), while major discrepancies were observed using disks of brand 1. One of the critical points in the diffusion disk test is the quality of the disks: the use of better quality disks associated with molecular methods lead to better results to define the best antibiotic therapy.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Seven swine were experimentally infected with Taenia solium eggs and blood samples from each animal were periodically collected. At the end of the experiment (t140) the animals did not show clinical aspects of cysticercosis or parasites in tongue inspection. All animals were slaughtered and cut into thin slices in searching for cysts. The number of cysts found in each animal varied from 1 to 85. Enzyme-linked immunosorbent assay (ELISA) tests for antibody (Ab) detection and for antigen (Ag) detection were performed, which presented respectively 71 and 57% of positivity. By immunoblot (IB), using 18/14(T. crassiceps Ag) or lentil-lectin-purified glycoproteins from T. solium Ag (LLGP) as Ag, five (71%) and six (86%) animals were positive, respectively. The association between Ag-ELISA with any IB (18/14 or LLGP) allowed the detection of all animals at 140 days post-experimental infection (days p.e.i.). The use of IB 18/14 combined to the Ag-ELISA allowed the detection of all animals since 70 days p.e.i., and the association between IB LLGP and Ag-ELISA allowed the detection of all animals since 112 days p.e.i. While all animals could be considered healthy by conventional screening tests, the use of immunoassays for detecting Ab and Ag showed better accuracy; therefore it would be more useful than usual clinical examination for screening cysticercosis in slightly infected pigs.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

We identified different diarrheagenic (DEC) Escherichia coli pathotypes isolated from 1,207 children with and without acute endemic diarrhea in Salvador, Bahia, Brazil collected as part of a case-control study. Since the identification of DEC cannot be based on only biochemical and culture criteria, we used a multiplex polymerase chain reaction developed by combining five specific primer pairs for Enteropathogenic Escherichia coli (EPEC), Shiga toxin-producing E. coli/ Enterohaemorrhagic E. coli (STEC/EHEC), Enterotoxigenic E. coli (ETEC) and Enteroaggregative E. coli (EAEC) to detect these pathotypes simultaneously in a single-step reaction. In order to distinguish typical and atypical EPEC strains, these were tested for the presence of EAF plasmid. The prevalence of diarrheagenic E. coli in this sample of a global case-control study was 25.4% (259 patients) and 18.7% (35 patients) in the diarrhea group (1,020 patients) and the control group (187 patients), respectively. The most frequently isolated pathotype was EAEC (10.7%), followed by atypical EPEC (9.4%), ETEC (3.7%), and STEC (0.6%). Typical EPEC was detected only in one sample. The prevalence of the pathotypes studied in children with diarrhea was not significantly different from that in children without diarrhea.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The frequency and severity of human infections associated with Corynebacterium ulcerans appear to be increasing in different countries. Here, we describe the first C. ulcerans strain producing a diphtheria-like toxin isolated from an elderly woman with a fatal pulmonary infection and a history of leg skin ulcers in the Rio de Janeiro metropolitan area.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Elevation of the biliary CEA level in patients with liver metastases from colorectal carcinoma has been reported. The aim of this study is to determine the potential value of biliary CEA assay in the early detection of liver metastases. Biliary and serum CEA levels were determined in patients operated on for a colorectal cancer and in control groups. Among 13 patients with liver metastases from colorectal carcinomas, biliary CEA levels were markedly elevated (> 40 ng/ml) in nine, moderately elevated (5-40 ng/ml) in two and normal (arbitrarily defined as < 5 ng/ml) in two. Of 28 patients with primary colorectal carcinoma without detectable hepatic secondaries, three had marked CEA elevation in the bile, 10 had moderate CEA elevation and 15 had normal levels. Among nine patients with non-malignant hepatobiliary pathology, there was one marked biliary CEA elevation, one moderate elevation and seven normal levels. None of the 13 individuals with no identified hepatobiliary pathology had elevated biliary CEA levels. The follow-up of patients with a primary colorectal tumour, no evidence of hepatic secondaries and a biliary CEA elevation is of particular interest. If subsequent appearance of liver metastases is found in such cases, intra-operative biliary CEA assay could be considered a valuable diagnostic test. Further studies will then have to prove the possible benefit of a specific treatment for this group of patients.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The incidence of Shigella spp. was assessed in 877 infants from the public hospital in Rondônia (Western Amazon region, Brazil) where Shigella represents the fourth cause of diarrhea. Twenty-five isolates were identified: 18 were Shigella flexneri, three Shigella sonnei, three Shigella boydii and one Shigella dysenteriae. With the exception of S. dysenteriae, all Shigella spp. isolated from children with diarrhea acquired multiple antibiotic resistances. PCR detection of ipa virulence genes and invasion assays of bloody diarrhea and fever (colitis) were compared among 25 patients testing positive for Shigella. The ipaH and ipaBCD genes were detected in almost all isolates and, unsurprisingly, all Shigella isolates associated with colitis were able to invade HeLa cells. This work alerts for multiple antibiotic resistant Shigella in the region and characterizes presence of ipa virulence genes and invasion phenotypesin dysenteric shigellosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

The objective of this study was to evaluate the prevalence and dissemination of human astroviruses (HAstV) in the environment by analyzing urban sewage samples from a wastewater treatment plant in the city of Rio de Janeiro, Brazil. A one-year study was performed with a total of 48 raw and treated sewage composite samples, which were collected biweekly from an activated sludge plant. Virus particles were concentrated by the adsorption-elution method using negatively charged membranes associated to a Centriprep Concentrator® 50 (Nihon Millipore). HAstV were detected in 16.7% of the samples in raw and treated sewage by using both qualitative and quantitative reverse transcriptase-polymerase chain reactions (RT-PCR and qPCR, respectively). Positive untreated sewage sample exhibited mean values of 1.1 x 10(4) gEq/mL. The qPCR sensitivity was 18 gEq/reaction. Through utilization of qPCR, a HAstV recovery efficiency of 4.2% and 4.3% was demonstrated for raw and treated sewage samples, respectively. The presence of HAstV in both the raw and treated sewage samples demonstrated the dissemination of these viruses in the environment as well as viral permanence after sewage treatment. There was a reduction in the total and faecal coliform levels, indicating efficiency of the wastewater treatment plant.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Human adenovirus (HAdV) and human respiratory syncytial virus (HRSV) are important etiologic agents of acute respiratory infections. In this study, a duplex polymerase chain reaction (PCR) assay was developed for the simultaneous detection of HAdV and HRSV in clinical samples. Sixty previously screened nasopharyngeal aspirates were used: 20 HAdV-positive, 20 HRSV-positive and 20 double-negative controls. Eight samples were positive for both viruses. The duplex PCR assay proved to be as sensitive and specific as single-target assays and also detected the mixed infections with certainty. The identification of both viruses in a single reaction offers a reduction in both cost and laboratory diagnostic time.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Water is a vehicle for disseminating human and veterinary toxoplasmosis due to oocyst contamination. Several outbreaks of toxoplasmosis throughout the world have been related to contaminated drinking water. We have developed a method for the detection of Toxoplasma gondii oocysts in water and we propose a strategy for the detection of multiple waterborne parasites, including Cryptosporidium spp. and Giardia. Water samples were filtered to recover Toxoplasma oocysts and, after the detection of Cryptosporidium oocysts and Giardia cysts by immunofluorescence, as recommended by French norm procedure NF T 90-455, the samples were purified on a sucrose density gradient. Detection of Toxoplasma was based on PCR amplification and mouse inoculation to determine the presence and infectivity of recovered oocysts. After experimental seeding assays, we determined that the PCR assay was more sensitive than the bioassay. This strategy was then applied to 482 environmental water samples collected since 2001. We detected Toxoplasma DNA in 37 environmental samples (7.7%), including public drinking water; however, none of them were positive by bioassay. This strategy efficiently detects Toxoplasma oocysts in water and may be suitable as a public health sentinel method. Alternative methods can be used in conjunction with this one to determine the infectivity of parasites that were detected by molecular methods.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A study was carried out to evaluate the presence of serological markers for the immunodiagnosis of the vertical transmission of toxoplasmosis. We tested the sensitivity, specificity and predictive values (positive and negative) of different serological methods for the early diagnosis of congenital toxoplasmosis. In a prospective longitudinal study, 50 infants with suspected congenital toxoplasmosis were followed up in the ambulatory care centre of Congenital Infections at University Hospital in Goiânia, Goiás, Brazil, from 1 January 2004-30 September 2005. Microparticle Enzyme Immunoassay (MEIA), Enzyme-Linked Fluorescent Assay (ELFA) and Immune-Fluorescent Antibody Technique (IFAT) were used to detect specific IgM anti-Toxoplasma gondii antibodies and a capture ELISA was used to detect specific IgA antibodies. The results showed that 28/50 infants were infected. During the neonatal period, IgM was detected in 39.3% (11/28) of those infected infants and IgA was detected in 21.4% (6/28). The sensitivity, specificity and predictive values (positive and negative) of each assay were, respectively: MEIA and ELFA: 60.9%, 100%, 100%, 55.0%; IFAT: 59.6%, 91.7%, 93.3%, 53.7%; IgA capture ELISA: 57.1%, 100%, 100%, 51.2%. The presence of specific IgM and IgA antibodies during the neonatal period was not frequent, although it was correlated with the most severe cases of congenital transmission. The results indicate that the absence of congenital disease markers (IgM and IgA) in newborns, even after confirming the absence with several techniques, does not constitute an exclusion criterion for toxoplasmosis.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Significant advances were made in the diagnosis of filariasis in the 1990s with the emergence of three new alternative tools: ultrasound and tests to detect circulating antigen using two monoclonal antibodies, Og4C3 and AD12-ICT-card. This study aimed to identify which of these methods is the most sensitive for diagnosis of infection. A total of 256 individuals, all male and carrying microfilariae (1-15,679 MF/mL), diagnosed by nocturnal venous blood samples, were tested by all three techniques. The tests for circulating filarial antigen concurred 100% and correctly identified 246/256 (96.69%) of the positive individuals, while ultrasound detected only 186/256 (73.44%). Of the circulating antigen tests, ICT-card was the most convenient method for identification of Wuchereria bancrofti carriers. It was easy to perform, practical and quick.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Mutations in the katG gene have been identified and correlated with isoniazid (INH) resistance in Mycobacterium tuberculosis isolates. The mutation AGC→ACC (Ser→Thr) at katG315 has been reported to be the most frequent and is associated with transmission and multidrug resistance. Rapid detection of this mutation could therefore improve the choice of an adequate anti-tuberculosis regimen, the epidemiological monitoring of INH resistance and, possibly, the tracking of transmission of resistant strains. An in house reverse hybridisation assay was designed in our laboratory and evaluated with 180 isolates of M. tuberculosis. It could successfully characterise the katG315 mutation in 100% of the samples as compared to DNA sequencing. The test is efficient and is a promising alternative for the rapid identification of INH resistance in regions with a high prevalence of katG315 mutants.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

Purpose: To evaluate the diagnostic value and image quality of CT with filtered back projection (FBP) compared with adaptive statistical iterative reconstructed images (ASIR) in body stuffers with ingested cocaine-filled packets.Methods and Materials: Twenty-nine body stuffers (mean age 31.9 years, 3 women) suspected for ingestion of cocaine-filled packets underwent routine-dose 64-row multidetector CT with FBP (120kV, pitch 1.375, 100-300 mA and automatic tube current modulation (auto mA), rotation time 0.7sec, collimation 2.5mm), secondarily reconstructed with 30 % and 60 % ASIR. In 13 (44.83%) out of the body stuffers cocaine-filled packets were detected, confirmed by exact analysis of the faecal content including verification of the number (range 1-25). Three radiologists independently and blindly evaluated anonymous CT examinations (29 FBP-CT and 68 ASIR-CT) for the presence and number of cocaine-filled packets indicating observers' confidence, and graded them for diagnostic quality, image noise, and sharpness. Sensitivity, specificity, area under the receiver operating curve (ROC) Az and interobserver agreement between the 3 radiologists for FBP-CT and ASIR-CT were calculated.Results: The increase of the percentage of ASIR significantly diminished the objective image noise (p<0.001). Overall sensitivity and specificity for the detection of the cocaine-filled packets were 87.72% and 76.15%, respectively. The difference of ROC area Az between the different reconstruction techniques was significant (p= 0.0101), that is 0.938 for FBP-CT, 0.916 for 30 % ASIR-CT, and 0.894 for 60 % ASIR-CT.Conclusion: Despite the evident image noise reduction obtained by ASIR, the diagnostic value for detecting cocaine-filled packets decreases, depending on the applied ASIR percentage.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

A new oligochromatographic assay, Speed-Oligo Novel Influenza A H1N1, was designed and optimized for the specific detection of the 2009 influenza A H1N1 virus. The assay is based on a PCR method coupled to detection of PCR products by means of a dipstick device. The target sequence is a 103-bp fragment within the hemagglutinin gene. The analytical sensitivity of the new assay was measured with serial dilutions of a plasmid that contained the target sequence, and we determined that down to one copy per reaction of the plasmid was reliably detected. Diagnostic performance was assessed with 103 RNAs from suspected cases (40 positive and 63 negative results) previously analyzed with a reference real-time PCR technique. All positive cases were confirmed, and no false-positive results were detected with the new assay. No cross-reactions were observed when other viral strains or clinical samples with other respiratory viruses were tested. According to these results, this new assay has 100% sensitivity and specificity. The turnaround time for the whole procedure was 140 min. The assay may be especially useful for the specific detection of 2009 H1N1 virus in laboratories not equipped with real-time PCR instruments