989 resultados para far-infrared spectra
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
Thesis (Ph.D.)--University of Washington, 2016-08
Resumo:
Upconverting nanoparticles have attracted much attention in science recently, specifically in view of medical and biological applications such as live imaging of cell temperatures or cancer treatment. The previously studied system of gadolinium oxide nanorods co-doped with erbium and ytterbium and decorated with different number densities of gold nanoparticles has been studied. So far, these particles have been proven as efficient nanothermometers in a temperature range from 300 up to 2000 K. In this work, a more detailed study on the morphological and radiative behaviour of these particles has been conducted. It was found that the laser power threshold for the onset of the black body radiation decreases strongly with the increase in the gold concentration. The temperature of the onset itself seems to remain approximately constant. The heating efficiency was determined to increase significantly with the gold concentration. The morphological study revealed that the temperature at the black body radiation threshold was not enough to induce any significant transformation in neither the nanorods nor the gold nanoparticles, as was expected from comparison with literature. However, significant changes in radiative properties and the morphology were detected for powders that underwent strong laser heating until the emission of brightly visible black body radiation.
Resumo:
This thesis presents detailed observational studies of the extended distributions of gas, galaxies, and dark matter around hyperluminous quasars (HLQSOs) at high redshift. Taken together, these works aim to coherently describe the relationships between these massive, accreting black holes and their environments: the nature of the regions that give rise to such massive black holes, the effect of HLQSO radiation on their surrounding galaxies and gas, and the ability of both galaxies and black holes to shed new light on the formation and evolution of the other.
Chapter 2 focuses on the continuum-color-selected galaxies drawn from the Keck Baryonic Structure Survey (KBSS). The KBSS is a uniquely deep spectroscopic survey of star-forming galaxies in the same volumes of space as 15 HLQSOs at 2.5 <
Chapter 3 describes the first results from a new survey (KBSS-Lyα) conducted for this thesis. The KBSS-Lyα survey uses narrowband imaging to identify Lyα-emitters (LAEs) in the ~Mpc regions around eight of the KBSS HLQSOs. Many of these LAEs show the effect of reprocessed HLQSO radiation in their emission through the process known as Lyα fluorescence. In this chapter, these fluorescent LAEs are used to generate a coarse map of the average HLQSO ionizing emission on Mpc scales, thereby setting the first direct constraints of the lifetime and angular distribution of activity for a population of these uniquely luminous black holes.
Chapter 4 contains a more detailed description of the KBSS-Lyα survey itself and the detailed properties of the star-forming and fluorescent objects selected therein. Using imaging and spectroscopic data covering rest-frame UV and optical wavelengths, including spectra from the new near-infrared spectrometer MOSFIRE, we characterize this population of nascent galaxies in terms of their kinematics, enrichment, gas properties, and luminosity distribution while comparing and contrasting them with previously-studied populations of continuum-selected galaxies and LAEs far from the effects of HLQSO emission.
At the conclusion of this thesis, I briefly present future directions for the continuation of this research. In Appendix A, I provide background information on the instrumentation used in this thesis, including my own contributions to MOSFIRE.
Resumo:
Cosmic X-ray background synthesis models (Gilli 2007) require a significant fraction of obscured AGN, some of which are expected to be heavily obscured (Compton-thick), but the number density of observationally found obscured sources is still an open issue (Vignali 2010, 2014). This thesis work takes advantage of recent NuSTAR data and is based on a multiwavelength research approach. Gruppioni et al. 2016 compared the AGN bolometric luminosity, for a sample of local 12 micron Seyfert galaxies, derived from the SED decomposition to the same quantity obtained by the 2-10 keV luminosity (IPAC-NED). A difference up to two orders of magnitude resulted between these quantities for some sources. Thus, the intrinsic X-ray luminosity obtained correcting for the obscuration may be underestimated. In this thesis we have tested this hypothesis by re-analysing the X-ray spectra of three of the sources (UGC05101, NGC1194 and NGC3079), for which observations from NuSTAR and Chandra and/or XMM-Newton were available. This is meant to extend our analysis to energies above 10 keV and thus estimate the AGN column density as reliable as possible. For spectral fitting we made use of both the commonly used XSPEC package and the two very recent MYtorus and BNtorus physical models. The available wide bandpass allowed us to achieve new and more solid insights into the X-ray spectral properties of these sources. The measured absorption column densities are highly suggestive of heavy obscuration. Once corrected the X-ray AGN luminosity for the obscuration estimated through our spectral analysis, we compared the L(X) values in the 2-10 keV band with those derived from the MIR band, by means of the relation by Gandhi, 2009. As expected, the values derived from this relation are in good agreement with those we measured, indicating that the column densities were underestimated in the previous literature works.
Resumo:
The Fourier transform-infrared (FT-IR) signature of dry samples of DNA and DNA-polypeptide complexes, as studied by IR microspectroscopy using a diamond attenuated total reflection (ATR) objective, has revealed important discriminatory characteristics relative to the PO2(-) vibrational stretchings. However, DNA IR marks that provide information on the sample's richness in hydrogen bonds have not been resolved in the spectral profiles obtained with this objective. Here we investigated the performance of an all reflecting objective (ARO) for analysis of the FT-IR signal of hydrogen bonds in DNA samples differing in base richness types (salmon testis vs calf thymus). The results obtained using the ARO indicate prominent band peaks at the spectral region representative of the vibration of nitrogenous base hydrogen bonds and of NH and NH2 groups. The band areas at this spectral region differ in agreement with the DNA base richness type when using the ARO. A peak assigned to adenine was more evident in the AT-rich salmon DNA using either the ARO or the ATR objective. It is concluded that, for the discrimination of DNA IR hydrogen bond vibrations associated with varying base type proportions, the use of an ARO is recommended.
Resumo:
A miniaturised gas analyser is described and evaluated based on the use of a substrate-integrated hollow waveguide (iHWG) coupled to a microsized near-infrared spectrophotometer comprising a linear variable filter and an array of InGaAs detectors. This gas sensing system was applied to analyse surrogate samples of natural fuel gas containing methane, ethane, propane and butane, quantified by using multivariate regression models based on partial least square (PLS) algorithms and Savitzky-Golay 1(st) derivative data preprocessing. The external validation of the obtained models reveals root mean square errors of prediction of 0.37, 0.36, 0.67 and 0.37% (v/v), for methane, ethane, propane and butane, respectively. The developed sensing system provides particularly rapid response times upon composition changes of the gaseous sample (approximately 2 s) due the minute volume of the iHWG-based measurement cell. The sensing system developed in this study is fully portable with a hand-held sized analyser footprint, and thus ideally suited for field analysis. Last but not least, the obtained results corroborate the potential of NIR-iHWG analysers for monitoring the quality of natural gas and petrochemical gaseous products.
Resumo:
Split-plot design (SPD) and near-infrared chemical imaging were used to study the homogeneity of the drug paracetamol loaded in films and prepared from mixtures of the biocompatible polymers hydroxypropyl methylcellulose, polyvinylpyrrolidone, and polyethyleneglycol. The study was split into two parts: a partial least-squares (PLS) model was developed for a pixel-to-pixel quantification of the drug loaded into films. Afterwards, a SPD was developed to study the influence of the polymeric composition of films and the two process conditions related to their preparation (percentage of the drug in the formulations and curing temperature) on the homogeneity of the drug dispersed in the polymeric matrix. Chemical images of each formulation of the SPD were obtained by pixel-to-pixel predictions of the drug using the PLS model of the first part, and macropixel analyses were performed for each image to obtain the y-responses (homogeneity parameter). The design was modeled using PLS regression, allowing only the most relevant factors to remain in the final model. The interpretation of the SPD was enhanced by utilizing the orthogonal PLS algorithm, where the y-orthogonal variations in the design were separated from the y-correlated variation.
Resumo:
We report the STAR measurements of dielectron (e(+)e(-)) production at midrapidity (|y(ee)|<1) in Au+Au collisions at √[s(NN)]=200 GeV. The measurements are evaluated in different invariant mass regions with a focus on 0.30-0.76 (ρ-like), 0.76-0.80 (ω-like), and 0.98-1.05 (ϕ-like) GeV/c(2). The spectrum in the ω-like and ϕ-like regions can be well described by the hadronic cocktail simulation. In the ρ-like region, however, the vacuum ρ spectral function cannot describe the shape of the dielectron excess. In this range, an enhancement of 1.77±0.11(stat)±0.24(syst)±0.33(cocktail) is determined with respect to the hadronic cocktail simulation that excludes the ρ meson. The excess yield in the ρ-like region increases with the number of collision participants faster than the ω and ϕ yields. Theoretical models with broadened ρ contributions through interactions with constituents in the hot QCD medium provide a consistent description of the dilepton mass spectra for the measurement presented here and the earlier data at the Super Proton Synchrotron energies.
Resumo:
Atomic charge transfer-counter polarization effects determine most of the infrared fundamental CH intensities of simple hydrocarbons, methane, ethylene, ethane, propyne, cyclopropane and allene. The quantum theory of atoms in molecules/charge-charge flux-dipole flux model predicted the values of 30 CH intensities ranging from 0 to 123 km mol(-1) with a root mean square (rms) error of only 4.2 km mol(-1) without including a specific equilibrium atomic charge term. Sums of the contributions from terms involving charge flux and/or dipole flux averaged 20.3 km mol(-1), about ten times larger than the average charge contribution of 2.0 km mol(-1). The only notable exceptions are the CH stretching and bending intensities of acetylene and two of the propyne vibrations for hydrogens bound to sp hybridized carbon atoms. Calculations were carried out at four quantum levels, MP2/6-311++G(3d,3p), MP2/cc-pVTZ, QCISD/6-311++G(3d,3p) and QCISD/cc-pVTZ. The results calculated at the QCISD level are the most accurate among the four with root mean square errors of 4.7 and 5.0 km mol(-1) for the 6-311++G(3d,3p) and cc-pVTZ basis sets. These values are close to the estimated aggregate experimental error of the hydrocarbon intensities, 4.0 km mol(-1). The atomic charge transfer-counter polarization effect is much larger than the charge effect for the results of all four quantum levels. Charge transfer-counter polarization effects are expected to also be important in vibrations of more polar molecules for which equilibrium charge contributions can be large.
Resumo:
It is well known that long term use of shampoo causes damage to human hair. Although the Lowry method has been widely used to quantify hair damage, it is unsuitable to determine this in the presence of some surfactants and there is no other method proposed in literature. In this work, a different method is used to investigate and compare the hair damage induced by four types of surfactants (including three commercial-grade surfactants) and water. Hair samples were immersed in aqueous solution of surfactants under conditions that resemble a shower (38 °C, constant shaking). These solutions become colored with time of contact with hair and its UV-vis spectra were recorded. For comparison, the amount of extracted proteins from hair by sodium dodecyl sulfate (SDS) and by water were estimated by the Lowry method. Additionally, non-pigmented vs. pigmented hair and also sepia melanin were used to understand the washing solution color and their spectra. The results presented herein show that hair degradation is mostly caused by the extraction of proteins, cuticle fragments and melanin granules from hair fiber. It was found that the intensity of solution color varies with the charge density of the surfactants. Furthermore, the intensity of solution color can be correlated to the amount of proteins quantified by the Lowry method as well as to the degree of hair damage. UV-vis spectrum of hair washing solutions is a simple and straightforward method to quantify and compare hair damages induced by different commercial surfactants.
Resumo:
O objetivo deste trabalho foi o estudo do efeito do Grau de Hidrólise (GH) do poli(vinil álcool) (PVA) nas propriedades dos filmes à base de blendas de gelatina suína e PVA com dois GH. Os filmes foram produzidos com soluções com 2 g de macromoléculas/100 g de solução, contendo 23,1 g de PVA.100 g-1 de macromoléculas e 25 g de glicerol/100 g de macromoléculas. As propriedades mecânicas e térmicas, cor, opacidade, umidade e solubilidade, além de espectros de infravermelho com transformada de Fourier (FTIR) dos filmes, foram estudadas. As soluções foram analisadas por reometria dinâmica. Os filmes produzidos com o PVA de menor GH foram mais higroscópicos e mais solúveis. Mas o tipo de PVA não afetou a cor, afetando a opacidade e o brilho dos filmes. O PVA com maior GH proporcionou filmes mais resistentes, e o PVA de menor GH produziu filmes mais resistentes à tração, embora menos deformáveis na perfuração. O GH do PVA não afetou a temperatura de transição vítrea dos filmes, determinada na primeira varredura, mas a afetou na segunda varredura. Os resultados das análises de FTIR corroborraram com esses resultados. As propriedades viscoelásticas das soluções não foram afetadas pelo GH do PVA, muito possivelmente por se tratar de soluções diluídas.
Resumo:
The 4,5-diamine-2,6-dimercaptopyrimidine (DADMcP) compound is an interesting multifunctional species exhibiting a rather complex tautomerism, encompassing nine tautomeric forms. Investigation of tautomerism in this compound has been carried out by means of FTIR spectroscopy, in association with ab-initio HF/SCF and DFT calculations. According to this study three tautomers are energetically favored; the thione form being the most stable one. The theoretical vibrational spectra of such tautomeric forms have been successfully simulated by means of DFT calculations, allowing the elucidation and assignment of the complex composition of the vibrational bands observed for the mixture of isomers.
Resumo:
Searches for field horizontal-branch (FHB) stars in the halo of the Galaxy in the past have been carried out by several techniques, such as objective-prism surveys and visual or infrared photometric surveys. By choosing adequate color criteria, it is possible to improve the efficiency of identifying bona fide FHB stars among the other objects that exhibit similar characteristics, such as main-sequence A-stars, blue stragglers, subdwarfs, etc. In this work, we report the results of a spectroscopic survey carried out near the south Galactic pole intended to validate FHB stars originally selected from the HK objective-prism survey of Beers and colleagues, based on near-infrared color indices. A comparison between the stellar spectra obtained in this survey with theoretical stellar atmosphere models allows us to determine T(eff), log g, and [Fe/H] for 13 stars in the sample. Stellar temperatures were calculated from measured (B-V)(o), when this measurement was available (16 stars). The color index criteria adopted in this work are shown to correctly classify 30% of the sample as FHB, 25% as non-FHB (main-sequence stars and subdwarfes), whereas 40% could not be distinguished between FHB and main-sequence stars. We compare the efficacy of different color criteria in the literature intended to select FHB stars, and discuss the use of the Mg II 4481 line to estimate the metallicity.
Resumo:
Single-point diamond turning of monocrystalline semiconductors is an important field of research within brittle materials machining. Monocrystalline silicon samples with a (100) orientation have been diamond turned under different cutting conditions (feed rate and depth of cut). Micro-Raman spectroscopy and atomic force microscopy have been used to assess structural alterations and surface finish of the samples diamond turned under ductile and brittle modes. It was found that silicon undergoes a phase transformation when machined in the ductile mode. This phase transformation is evidenced by the creation of an amorphous surface layer after machining which has been probed by Raman scattering. Compressive residual stresses are estimated for the machined surface and it is observed that they decrease with an increase in the feed rate and depth of cut. This behaviour has been attributed to the formation of subsurface cracks when the feed rate is higher than or equal to 2.5 mu m/rev. The surface roughness was observed to vary with the feed rate and the depth of cut. An increase in the surface roughness was influenced by microcrack formation when the feed rate reached 5.0 mu m/rev. Furthermore, a high-pressure phase transformation induced by the tool/material interaction and responsible for the ductile response of this typical brittle material is discussed based upon the presented Raman spectra. The application of this machining technology finds use for a wide range of high quality components, for example the creation of a micrometre-range channel for microfluidic devices as well as microlenses used in the infrared spectrum range.