991 resultados para extraction procedures


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Treatment of colonic diverticular disease has evolved over the past years. Most episodes are simple and can be successfully treated with antibiotics alone. For complicated diverticulitis, a strong trend is developing towards less invasive therapies including interventional radiology and laparoscopic lavage in an effort to avoid the morbidity and discomfort of a diverting colostomy. Based on a better understanding of the natural history of the disease, the indication to prophylactic colectomy after a few episodes of simple diverticulitis has been seriously challenged. For those patients who need a colectomy, single port laparoscopy, NOTES and transanal specimen extraction are being proposed. However larger studies are needed to confirm the hypothetical advantages of these evolving techniques.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

High performance liquid chromatography (HPLC) is the reference method for measuring concentrations of antimicrobials in blood. This technique requires careful sample preparation. Protocols using organic solvents and/or solid extraction phases are time consuming and entail several manipulations, which can lead to partial loss of the determined compound and increased analytical variability. Moreover, to obtain sufficient material for analysis, at least 1 ml of plasma is required. This constraint makes it difficult to determine drug levels when blood sample volumes are limited. However, drugs with low plasma-protein binding can be reliably extracted from plasma by ultra-filtration with a minimal loss due to the protein-bound fraction. This study validated a single-step ultra-filtration method for extracting fluconazole (FLC), a first-line antifungal agent with a weak plasma-protein binding, from plasma to determine its concentration by HPLC. Spiked FLC standards and unknowns were prepared in human and rat plasma. Samples (240 microl) were transferred into disposable microtube filtration units containing cellulose or polysulfone filters with a 5 kDa cut-off. After centrifugation for 60 min at 15000g, FLC concentrations were measured by direct injection of the filtrate into the HPLC. Using cellulose filters, low molecular weight proteins were eluted early in the chromatogram and well separated from FLC that eluted at 8.40 min as a sharp single peak. In contrast, with polysulfone filters several additional peaks interfering with the FLC peak were observed. Moreover, the FLC recovery using cellulose filters compared to polysulfone filters was higher and had a better reproducibility. Cellulose filters were therefore used for the subsequent validation procedure. The quantification limit was 0.195 mgl(-1). Standard curves with a quadratic regression coefficient > or = 0.9999 were obtained in the concentration range of 0.195-100 mgl(-1). The inter and intra-run accuracies and precisions over the clinically relevant concentration range, 1.875-60 mgl(-1), fell well within the +/-15% variation recommended by the current guidelines for the validation of analytical methods. Furthermore, no analytical interference was observed with commonly used antibiotics, antifungals, antivirals and immunosuppressive agents. Ultra-filtration of plasma with cellulose filters permits the extraction of FLC from small volumes (240 microl). The determination of FLC concentrations by HPLC after this single-step procedure is selective, precise and accurate.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Bien que les complications sévères de l'anesthésie soient actuellement rares, des informations contradictoires existent à propos du rôle et de l'importance de l'hypertension artérielle chronique sur la survenue de complications en cours d'anesthésie. En raison de la prévalence élevée de l'hypertension artérielle dans la population et du grand nombre d'anesthésies effectuées, il est important de clarifier cette relation. Le but de l'étude était d'évaluer si les personnes hypertendues étaient à risque accru de présenter des complications lors d'anesthésies à partir de données collectées de routine lors d'anesthésies usuelles réalisées en Suisse. Nous avons utilisé les données figurant dans le registre ADS (Anesthésie Données Suisse) correspondant à des anesthésies, générales ou locorégionales, réalisées pour chirurgie élective chez des adultes, entre 2000 et 2004 dans 24 hôpitaux suisses. L'attention était portée principalement sur les incidents cardio-vasculaires, mais les autres incidents relevés de routine ont aussi été évalués. La présence d'une hypertension artérielle chronique était définie par la présence d'un traitement antihypertenseur ou par l'anamnèse d'une hypertension artérielle, combinée à la mesure d'une pression artérielle élevée (systolique >160 mm Hg ou diastolique >100 mm Hg) lors de l'examen préopératoire de l'anesthésiste. Les incidents relevés en cours d'anesthésie ont été définis a priori et sont enregistrés de routine sur la feuille d'anesthésie et reportés dans une base de données centralisée. En raison de la structure des données, des analyses hiérarchiques ont été effectuées incluant des variables individuelles (niveau 1), liées aux groupes d'interventions chirurgicales (niveau 2) et à l'hôpital (niveau 3). Parmi les 124 939 interventions, 27 881 (22%) concernaient des patients connus pour une hypertension artérielle chronique. Au moins un incident est survenu dans 16,8% des interventions (95% Cl 16,6 -17,0%). Chez 7 549 patients, au moins un incident cardio- vasculaire est survenu, soit dans 6% des anesthésies (95% Cl 5.9-6.2%). Le rapport des cotes (odds ratio) moyen ajusté pour les incidents cardio-vasculaires chez les patients hypertendus était de 1.38 (95% Cl 1.27-1.49), indiquant une augmentation du risque chez les patients hypertendus. Cependant, l'hypertension n'était pas liée à un risque augmenté de survenue d'un autre incident. Les rapports de cotes ajustés de la survenue d'une complication cardiovasculaire en présence d'une hypertension artérielle variaient selon les hôpitaux entre 0.41 et 2.25. Ainsi, cette étude confirme la présence d'un risque accru de survenue d'une complication cardiovasculaire chez un patient hypertendu lors d'une anesthésie pour chirurgie élective. Il s'agissait le plus souvent d'une arythmie ou d'une perturbation hémodynamique. Cette augmentation du risque proche de 40% a aussi été trouvée dans une revue systématique avec méta-analyse. L'hétérogénéité des institutions -qui persiste même en tenant compte des ajustements pour le type d'intervention chirurgicale et des variables individuelles (case-mix) - suggère des différences de pratique de l'anesthésie selon l'hôpital.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Selostus: Alumiini- ja rautaoksidien fosforikyllästysasteen arvioiminen suomalaisista peltomaista

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Report on applying agreed-upon procedures to the Fayette County Engineer’s Office for the period July 1, 2012 through June 30, 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The goal of this study was to compare the quantity and purity of DNA extracted from biological tracesusing the QIAsymphony robot with that of the manual QIAamp DNA mini kit currently in use in ourlaboratory. We found that the DNA yield of robot was 1.6-3.5 times lower than that of the manualprotocol. This resulted in a loss of 8% and 29% of the alleles correctly scored when analyzing 1/400 and 1/800 diluted saliva samples, respectively. Specific tests showed that the QIAsymphony was at least 2-16times more efficient at removing PCR inhibitors. The higher purity of the DNA may therefore partlycompensate for the lower DNA yield obtained. No case of cross-contamination was observed amongsamples. After purification with the robot, DNA extracts can be automatically transferred in 96-wellsplates, which is an ideal format for subsequent RT-qPCR quantification and DNA amplification. Lesshands-on time and reduced risk of operational errors represent additional advantages of the robotic platform.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Intraarterial procedures such as chemoembolization and radioembolization aim for the palliative treatment of advanced hepatocellular carcinoma (stage BCLC B and C with tumoral portal thrombosis). The combination of hepatic intraarterial chemotherapy and systemic chemotherapy can increase the probability of curing colorectal cancer with hepatic metastases not immediately accessible to surgical treatment or percutaneous ablation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim  Background The expected benefit of transvaginal specimen extraction is reduced incision-related morbidity. Objectives A systematic review of transvaginal specimen extraction in colorectal surgery was carried out to assess this expectation. Method  Search strategy The following keywords, in various combinations, were searched: NOSE (natural orifices specimen extraction), colorectal, colon surgery, transvaginal, right hemicolectomy, left hemicolectomy, low anterior resection, sigmoidectomy, ileocaecal resection, proctocolectomy, colon cancer, sigmoid diverticulitis and inflammatory bowel diseases. Selection criteria Selection criteria included large bowel resection with transvaginal specimen extraction, laparoscopic approach, human studies and English language. Exclusion criteria were experimental studies and laparotomic approach or local excision. All articles published up to February 2011 were included. Results  Twenty-three articles (including a total of 130 patients) fulfilled the search criteria. The primary diagnosis was colorectal cancer in 51% (67) of patients, endometriosis in 46% (60) of patients and other conditions in the remaining patients. A concurrent gynaecological procedure was performed in 17% (22) of patients. One case of conversion to laparotomy was reported. In two patients, transvaginal extraction failed. In left- and right-sided resections, the rate of severe complications was 3.7% and 2%, respectively. Two significant complications, one of pelvic seroma and one of rectovaginal fistula, were likely to have been related to transvaginal extraction. The degree of follow up was specified in only one study. Harvested nodes and negative margins were adequate and reported in 70% of oncological cases. Conclusion  Vaginal extraction of a colorectal surgery specimen shows potential benefit, particularly when associated with a gynaecological procedure. Data from prospective randomized trials are needed to support the routine use of this technique.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agreed-upon procedures report on the Iowa Sheep and Wool Promotion Board for the period July 1, 2011 through June 30, 2013

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Rapport de synthèse : Le glaucome à angle ouvert est une neuropathie optique chronique progressive pour laquelle de nombreux traitements tant médicaux que chirurgicaux ont été proposés. La prise en charge chirurgicale s'articule principalement autour de deux chirurgies filtrantes, la trabéculectomie et la sclérectomie profonde avec implant de collagène. Cependant, les complications postopératoires de ces deux interventions étant relativement fréquentes, la recherche s'est orientée vers des traitements alternatifs dont la mise en place de micro-drains. Ces implants de drainage diminuent la pression intraoculaire en créant un court-circuit du flux d'humeur aqueuse de la chambre antérieure vers l'espace sous-conjonctival avec formation d'une bulle de filtration. L'implant Ex-PRESS R-50 est un implant miniature (2.5 mm de long pour 400 µm de diamètre) en acier inoxydable et biocompatible. La présente étude s'est proposée d'étudier l'efficacité et la sécurité de l'implant miniature Ex-Press R-50 lors d'une opération combinée cataracte-glaucome. Trente-cinq yeux de 35 patients (âge moyen: 75 ans) ont été inclus dans l'étude. Tous les patients ont bénéficié d'une opération de la cataracte par phacoemulsification et mise en place d'un implant de chambre postérieure suivie de l'implantation du micro-drain. Les pressions intraoculaires préopératoires et postopératoires, la meilleure acuité visuelle corrigée, le nombre de médicaments anti-glaucomateux ainsi que le type et le nombre de complications ont été évalués mensuellement puis tous les 6 mois pendant 4 ans. Le succès total a été défini par une pression postopératoire finale inférieure à 18mmHg sans traitement médical associé, le succès partiel par une pression postopératoire finale inférieure à 18mmHg avec ou sans traitement médical associé.. Le suivi moyen a été de 36.9 mois avec une baisse de la pression intraoculaire significative d'environ 25%. Une augmentation de l'acuité visuelle a été observée après l'opération de la cataracte et le nombre de médicaments anti-glaucomateux a été réduit de 57%. Dix patients ont bénéficié d'un traitement supplémentaire de la bulle de filtration par injection d'anti-métabolite (mitomycine C). Nous avons observé 8 complications majeures (4 érosions conjonctivales et 4 obstructions de l'orifice interne du micro-drain), toutes suivies de l'ablation de l'implant et de la réalisation d'une chirurgie classique du glaucome. En se basant sur les courbes de Kaplan-Meier à 48 mois, le taux de succès total était de 32.7% et le succès partiel de 53.7%. Nous pouvons conclure suite à ce travail que l'implant miniature Ex-PRESS R-50 est associé à un nombre trop élevé de complications, même si les cas non compliqués ont bénéficié d'une baisse significative de la pression intraoculaire. La modification de l'architecture du micro-drain ainsi que de la technique chirurgicale devrait augmenter le taux de succès.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Agreed-upon procedures report on the City of Urbana, Iowa for the period July 1, 2013 through June 30, 2014

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVES: This systematic review aims to assess the risks (both thromboembolic and bleeding) of an oral anticoagulation therapy (OAT) patient undergoing implant therapy and to provide a management protocol to patients under OAT undergoing implant therapy. MATERIAL AND METHODS: Medline, Cochrane Data Base of Systematic Reviews, the Cochrane Central Register of Controlled Trials and EMBASE (from 1980 to December 2008) were searched for English-language articles published between 1966 and 2008. This search was completed by a hand research accessing the references cited in all identified publications. RESULTS: Nineteen studies were identified reporting outcomes after oral surgery procedures (mostly dental extractions in patients on OAT following different management protocols and haemostatic therapies). Five studies were randomized-controlled trials (RCTs), 11 were controlled clinical trials (CCTs) and three were prospective case series. The OAT management strategies as well as the protocols during and after surgery were different. This heterogeneity prevented any possible data aggregation and synthesis. The results from these studies are very homogeneous, reporting minor bleeding in very few patients, without a significant difference between the OAT patients who continue with the vitamin K antagonists vs. the patients who stopped this medication before surgery. These post-operative bleeding events were controlled only with local haemostatic measures: tranexamic acid mouthwashes, gelatine sponges and cellulose gauzes's application were effective. Post-operative bleeding did not correlate with the international normalised ratio (INR) status. In none of the studies was a thromboembolic event reported. CONCLUSIONS: OAT patients (INR 2-4) who do not discontinue the AC medication do not have a significantly higher risk of post-operative bleeding than non-OAT patients and they also do not have a higher risk of post-operative bleeding than OAT patients who discontinue the medication. In patients with OAT (INR 2-4) without discontinuation, topical haemostatic agents were effective in preventing post-operative bleeding. OAT discontinuation is not recommended for minor oral surgery, such as single tooth extraction or implant placement, provided that this does not involve autogenous bone grafts, extensive flaps or osteotomy preparations extending outside the bony envelope. Evidence does not support that dental implant placement in patients on OAT is contraindicated.