985 resultados para exercise tests


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The treatment efficiency of laboratory wastewaters was evaluated and ecotoxicity tests with Chlorella vulgaris were performed on them to assess the safety of their environmental discharge. For chemical oxygen demand wastewaters, chromium (VI), mercury (II) and silver were efficiently removedby chemical treatments.Areduction of ecotoxicitywas achieved; nevertheless, an EC50 (effective concentration that causes a 50% inhibition in the algae growth) of 1.5% (v/v) indicated still high level of ecotoxicity. For chloride determination wastewaters, an efficient reduction of chromium and silver was achieved after treatment. Regarding the reduction of ecotoxicity observed, EC50 increased from 0.059% to 0.5%, only a 0.02% concentration in the aquatic environment would guarantee no effects. Wastewaters containing phenanthroline/iron (II) complex were treated by chemical oxidation. Treatmentwas satisfactory concerning chemical parameters, although an increase in ecotoxicitywas observed (EC50 reduced from 0.31% to 0.21%). The wastes from the kinetic study of persulphate and iodide reaction were treated with sodium bisulphite until colour was removed. Although they did not reveal significant ecotoxicity, only over 1% of the untreated waste produced observable effects over algae. Therefore, ecotoxicity tests could be considered a useful tool not only in laboratory effluents treatment, as shown, but also in hazardous wastewaters management.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

COPD is a major cause of morbidity and mortality worldwide, representing a major public health problem due to the high health and economic resource consumption. Pulmonary rehabilitation is a standard care recommendation for these patients, in order to control the symptoms and optimize the functional capacity, reducing health care costs associated with exacerbations and activity limitations and participation. However, in patients with severe COPD exercise performance can be difficult, due to extreme dyspnea, decreased muscle strength and fatigue. In addition, hypoxemia and dyspnea during efforts and daily activities may occur, limiting their quality of life. Thus, NIV have been used as adjunct to exercise, in order to improve exercise capacity in these patients. However, there is no consensus for this technique recommendation. Our objective was to verify whether the use of NIV during exercise is effective than exercise without NIV in dyspnea, walked distance, blood gases and health status in COPD patients, through a systematic review and meta-analysis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: Multiple sclerosis is a disease of the central nervous system that affects more frequently young women. It is a progressive and unpredictable disease, resulting in some cases of disabilities and limitations to physical, psychological and social level. Purpose: To review the literature for evidence based of the effectiveness of physiotherapy intervention in multiple sclerosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents a layered Smart Grid architecture enhancing security and reliability, having the ability to act in order to maintain and correct infrastructure components without affecting the client service. The architecture presented is based in the core of well design software engineering, standing upon standards developed over the years. The layered Smart Grid offers a base tool to ease new standards and energy policies implementation. The ZigBee technology implementation test methodology for the Smart Grid is presented, and provides field tests using ZigBee technology to control the new Smart Grid architecture approach. (C) 2014 Elsevier Ltd. All rights reserved.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

OBJECTIVE To assess the factors associated with the use of dietary supplements by people who exercise at gyms.METHODS A cross-sectional study with a sample defined by convenience, considering the number of gyms registered in the Conselho Regional de Educação Física (Regional Council of Physical Education) of Sao Luis, MA, Northeastern Brazil, from July 2011 to July 2012. The final sample comprised 723 individuals who exercise at gyms. The dependent variable was supplement use, and the explanatory variables were length of time and motivation of the physical exercises, duration, goal and self-perception of training, weekly frequency of gym attendance, sex, age, educational attainment, self-perception of body weight, smoking and self-perception of diet. The association between variables was analysed by hierarchical Poisson regression based on a theoretical model.RESULTS Supplement use was reported by 64.7% of the participants. Most of the sample was male (52.6%). The most frequent age group was 20 to 39 years (74.4%). Most participants (46.1%) had been exercising for over a year. The following variables were associated with supplement use: self-perceiving body weight as below ideal (p < 0.001), smoking (p < 0.001), exercising for 7 to 12 months (p = 0.028) or more than one year (p < 0.001), spending more than two hours at the gym (p = 0.051), and perceiving training as moderate (p = 0.024) or intense (p = 0.001).CONCLUSIONS The use of supplements lacks proper professional guidance, being motivated by individuals unsatisfied with their low body weight and who perceive their workout as intense, which raises the need for monitoring this population.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Micro-abrasion wear tests with ball-cratering configuration are widely used. Sources of variability are already studied by different authors and conditions for testing are parameterized by BS EN 1071-6: 2007 standard which refers silicon carbide as abrasive. However, the use of other abrasives is possible and allowed. In this work, ball-cratering wear tests were performed using four different abrasive particles of three dissimilar materials: diamond, alumina and silicon carbide. Tests were carried out under the same conditions on a steel plate provided with TiB2 hard coating. For each abrasive, five different test durations were used allowing understanding the initial wear phenomena. Composition and shape of abrasive particles were investigated by SEM and EDS. Scar areas were observed by optical and electronic microscopy in order to understand the wear effects caused by each of them. Scar geometry and grooves were analyzed and compared. Wear coefficient was calculated for each situation. It was observed that diamond particles produce well-defined and circular wear scars. Different silicon carbide particles presented dissimilar results as consequence of distinct particle shape and size distribution.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Em termos profissionais, a satisfação no trabalho é sem dúvida um tema bastante debatido e atual. Neste sentido, este estudo teve como objetivo analisar a satisfação profissional dos enfermeiros especialistas em enfermagem de reabilitação e também averiguar se o local de trabalho ou o exercício de cuidados de especialidade influenciam a satisfação profissional deste grupo de enfermeiros. A satisfação profissional foi avaliada através da aplicação da “Escala de Avaliação da Satisfação no Trabalho dos Enfermeiros”, construída e validada por Frederico & Loureiro (2009) a 306 profissionais de Enfermagem, especialistas em enfermagem de reabilitação. O Alpha de Cronbach foi de 0,85, refletindo um bom nível de consistência interna. Foram analisadas seis dimensões da satisfação: satisfação com as chefias; satisfação com benefícios e recompensas; satisfação com a natureza do trabalho; satisfação com a comunicação; satisfação com a equipa e satisfação com os requisitos do trabalho. Foi realizado um estudo transversal analítico. Na análise estatística dos dados, recorreu-se à análise fatorial, ao coeficiente de correlação de Spearman, a testes paramétricos t-student para amostras independentes e One-Way ANOVA. Os resultados mostram que os enfermeiros especialistas em enfermagem de reabilitação encontram-se ligeiramente insatisfeitos. Os fatores de insatisfação estão relacionados com benefícios e recompensas, requisitos do trabalho e com a comunicação. A natureza do trabalho e o relacionamento com a equipa são fatores com os quais obtêm maior satisfação. Em relação às chefias existe uma aproximação à satisfação. Relativamente à avaliação do grau de satisfação profissional global, concluiu-se que os enfermeiros que exercem funções nos Cuidados de Saúde Primários encontram-se mais insatisfeitos profissionalmente, do que os que exercem a sua atividade profissional ao nível hospitalar. Os enfermeiros que exercem cuidados gerais apresentam-se mais insatisfeitos do que os que exercem cuidados de especialidade. Também a idade e a remuneração pelo cargo desempenhado são fatores determinantes. Os enfermeiros mais jovens são os que se apresentam mais insatisfeitos. Os enfermeiros que não são remunerados pelo cargo desempenhado demonstram maior insatisfação profissional.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Nanocrystalline diamond (NCD) coatings offer an excellent alternative for tribological applications, preserving most of the intrinsic mechanical properties of polycrystalline CVD diamond and adding to it an extreme surface smoothness. Silicon nitride (Si3N4) ceramics are reported to guarantee high adhesion levels to CVD microcrystalline diamond coatings, but the NCD adhesion to Si3N4 is not yet well established. Micro-abrasion tests are appropriate for evaluating the abrasive wear resistance of a given surface, but they also provide information on thin film/substrate interfacial resistance, i.e., film adhesion. In this study, a comparison is made between the behaviour of NCD films deposited by hot-filament chemical vapour deposition (HFCVD) and microwave plasma assisted chemical vapour deposition (MPCVD) techniques. Silicon nitride (Si3N4) ceramic discs were selected as substrates. The NCD depositions by HFCVD and MPCVD were carried out using H2–CH4 and H2–CH4–N2 gas mixtures, respectively. An adequate set of growth parameters was chosen for each CVD technique, resulting in NCD films having a final thickness of 5 m. A micro-abrasion tribometer was used, with 3 m diamond grit as the abrasive slurry element. Experiments were carried out at a constant rotational speed (80 r.p.m.) and by varying the applied load in the range of 0.25–0.75 N. The wear rate for MPCVD NCD (3.7±0.8 × 10−5 m3N−1m−1) is compatible with those reported for microcrystalline CVD diamond. The HFCVD films displayed poorer adhesion to the Si3N4 ceramic substrates than the MPCVD ones. However, the HFCVD films show better wear resistance as a result of their higher crystallinity according to the UV Raman data, despite evidencing premature adhesion failure.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Ball rotating micro-abrasion tribometers are commonly used to carry out wear tests on thin hard coatings. In these tests, different kinds of abrasives were used, as alumina (Al2O3), silicon carbide (SiC) or diamond. In each kind of abrasive, several particle sizes can be used. Some studies were developed in order to evaluate the influence of the abrasive particle shape in the micro-abrasion process. Nevertheless, the particle size was not well correlated with the material removed amount and wear mechanisms. In this work, slurry of SiC abrasive in distilled water was used, with three different particles size. Initial surface topography was accessed by atomic force microscopy (AFM). Coating hardness measurements were performed with a micro-hardness tester. In order to evaluate the wear behaviour, a TiAlSiN thin hard film was used. The micro-abrasion tests were carried out with some different durations. The abrasive effect of the SiC particles was observed by scanning electron microscopy (SEM) both in the films (hard material) as in the substrate (soft material), after coating perforation. Wear grooves and removed material rate were compared and discussed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This work is a contribution to the e-Framework, arguably the most prominent e-learning framework today, and consists of the definition of a service for the automatic evaluation of programming exercises. This evaluation domain differs from trivial evaluations modelled by languages such as the IMS Question & Test Interoperability (QTI) specification. Complex evaluation domains justify the development of specialized evaluators that participate in several business processes. These business processes can combine other type of systems such as Programming Contest Management Systems, Learning Management Systems, Integrated Development Environments and Learning Object Repositories where programming exercises are stored as Learning Objects. This contribution describes the implementation approaches used, more precisely, behaviours & requests, use & interactions, applicable standards, interface definition and usage scenarios.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

A serologic study was undertaken in a group of 43 patients with active paracoccidioidomycosis who were treated in the same form (ketoconazole), for identical periods of time (6 months), and folio wed-up for various periods posttherapy. The tests employed were agar gel immunodiffusion (AGID) and complement fixation (FC). Also studied were 50 sera from patients with proven histoplasmosis and pulmonary aspergilloma, 30 patients with culturaly proven tuberculosis as well as 92 specimens from healthy individuals, residents in the endemic area for paracoccidioidomycosis. A single lot of yeast filtrate antigen was used throughout the study. The value of each test was measured according to GALEN and GAMBINO6. Both tests were highly sensitive, 89 and 93% respectively. Regarding their specificity, the AGID was totally specific while the CF exhibited 96.6% and 97% specificity in front of tuberculosis patients and healthy individuals respectively and 82% in comparison with patients with other mycoses. The concept of predictive value, that is, the certainty one has in accepting a positive test as diagnostic of paracoccidioidomycosis, favored the AGID procedure (100%) over the CF test. The latter could sort out with 93% certainty a patient with paracoccidioidomycosis among a group of healthy individuals and with 97.5% in the case of TB patients; when the group in question was composed by individuals with other deep mycoses, such certainty was lower (81%). The above results indicate that both the AGID and the CF tests furnish results of high confidence; one should not relay, however, in the CF alone as a means to establish the specific diagnosis of paracoccidioidomycosis.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introdução: em indivíduos com dor lombo-pélvica (LPP), parece existir uma alteração de controlo motor e diminuição da endurance dos músculos do tronco. A realização de exercícios de controlo motor pode melhorar a endurance dessa musculatura e consequentemente o controlo motor. Objetivos: detetar diferenças nos tempos e rácios de endurance dos músculos do tronco em indivíduos com e sem dor lombo-pélvica e avaliar o efeito de dois programas de exercícios de controlo motor (segundo Richardson e segundo McGill) nos mesmos outcomes em indivíduos com LPP. Métodos: estudo transversal com uma amostra de 111 indivíduos, 52 para o grupo sem dor (NLPP) e 59 para o com LPP e estudo experimental, constituído pelos indivíduos LPP (59), alocados nos grupos de Pilates (20), McGill (20) ou no grupo controlo (19). Avaliaramse os tempos obtidos nos testes de endurance para os músculos extensores, flexores, flexores laterais direitos e esquerdos do tronco e respetivos rácios, tendo em conta o modelo de McGill. As avaliações dos grupos do estudo experimental realizaram-se antes e após as 8 semanas de exercício. Resultados: os indivíduos com LPP apresentaram tempos e rácios de endurance significativamente inferiores aos indivíduos NLPP (p<0.001). Após as 8 semanas de exercício, registaram-se diferenças estatisticamente significativas entre os grupos em todos os testes de endurance, sendo que o grupo de McGill apresentou tempos significativamente superiores aos do grupo de Pilates para os músculos flexores (p=0.001), flexores laterais direitos (p=0.002) e esquerdos (p=0.009). Quanto aos rácios de endurance, não se detetaram apenas diferenças estatisticamente significativas no rácio flexão lateral esquerda/extensão. Conclusão: os indivíduos com LPP apresentaram tempos e rácios de endurance do tronco inferiores aos dos indivíduos sem dor. Ambos os programas de exercícios melhoraram os tempos e os rácios de endurance, tendo existido uma tendência para melhores resultados na abordagem segundo McGill

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Indirect Immunofluorescence (IFA), Plaque Reduction Neutralization (PRN) and Haemagglutination Inhibition (HI) tests for measles antibodies were carried out in 197 sera obtained from umbilical cord and vaccinated children. The IFA was also applied to blood samples collected with filter paper. IFA results demonstrated that the test is relatively simple to perform, with good reproducibility for different antigen lots. Good correlation was obtained between IFA, PRN and HI antibody titers. Better correlation was demonstrated with IFA and PRN than with HI and PRN tests. Sensitivity of IFA in detecting antibody was less effective than PRN, however more effective than HI using rhesus monkey red blood cells. PRN antibody titers over 100 were detected by IFA but not by HI (9.7% with negative results). IFA may be of considerable practical use and able to substitute HI in Seroepidemiological surveys and to evaluate vaccine efficacy. It also can be simplified by employing filter paper collected samples.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An enzyme-linked immunosorbent assay (ELISA) for measles antibodies was compared with Plaque Neutralization (PRN), Haemagglutination inhibition (HI) and Fluorescent antibody (IFA) tests in 181 sera from vaccinated children and umbilical cord. Of 179 positive samples by the sensitive PRN, only two, with titers of 8, were negative by ELISA (copositivity of 98.9%). IFA and HI presented, respectively, copo-sitivities of 93.3% and 82.7%. The ELISA presented a high sensitivity as well as a good reproducibility and represents an alternative for the time consuming PRN for detection of low measles antibodies.