787 resultados para difference-in-differences
Resumo:
Background: The goal of this study was to determine whether site-specific differences in the subgingival microbiota could be detected by the checkerboard method in subjects with periodontitis. Methods: Subjects with at least six periodontal pockets with a probing depth (PD) between 5 and 7 mm were enrolled in the study. Subgingival plaque samples were collected with sterile curets by a single-stroke procedure at six selected periodontal sites from 161 subjects (966 subgingival sites). Subgingival bacterial samples were assayed with the checkerboard DNA-DNA hybridization method identifying 37 species. Results: Probing depths of 5, 6, and 7 mm were found at 50% (n = 483), 34% (n = 328), and 16% (n = 155) of sites, respectively. Statistical analysis failed to demonstrate differences in the sum of bacterial counts by tooth type (P = 0.18) or specific location of the sample (P = 0.78). With the exceptions of Campylobacter gracilis (P <0.001) and Actinomyces naeslundii (P <0.001), analysis by general linear model multivariate regression failed to identify subject or sample location factors as explanatory to microbiologic results. A trend of difference in bacterial load by tooth type was found for Prevotella nigrescens (P <0.01). At a cutoff level of >/=1.0 x 10(5), Porphyromonas gingivalis and Tannerella forsythia (previously T. forsythensis) were present at 48.0% to 56.3% and 46.0% to 51.2% of sampled sites, respectively. Conclusions: Given the similarities in the clinical evidence of periodontitis, the presence and levels of 37 species commonly studied in periodontitis are similar, with no differences between molar, premolar, and incisor/cuspid subgingival sites. This may facilitate microbiologic sampling strategies in subjects during periodontal therapy.
Resumo:
OBJECTIVE: To test the null hypothesis that there is no difference between premolar position visualized on panoramic radiographs (PRs) and lateral headfilms (LHs). MATERIALS AND METHODS: The prevalence of differences in the direction of crown angulation between PR and LH was assessed. Furthermore, brass wire markers with different sagittal and transverse angulations were placed in a dry skull. With the markers in place, LHs and PRs were taken. RESULTS: A difference in the direction of crown angulation of unerupted second premolars between PR and LH occurred in 19.5% of patients. The reason for the angulation differences is a buccolingual orientation of the tooth, which appears as a mesiodistal angulation on the PR. CONCLUSION: The null hypothesis was rejected since in one-fifth of the patients premolar projection differs between the panoramic radiograph and the lateral headfilm.
Resumo:
BACKGROUND: The aim was to assess the clinical relevance of the World Health Organization and tumour node metastasis (TNM) classifications in patients with pancreatic neuroendocrine tumours (pNETs). METHODS: Prospectively collected data from 118 consecutive patients with a pNET receiving surgical intervention were analysed. RESULTS: Forty-one patients had well differentiated neuroendocrine tumours, 64 had well differentiated neuroendocrine carcinomas and 13 had poorly differentiated neuroendocrine carcinomas. Five-year survival rates were 95, 44 and 0 per cent respectively (P < 0.001). There was no difference in survival after R0 and R1/R2 resections in patients with neuroendocrine carcinomas (P = 0.905). In those with well differentiated neuroendocrine carcinomas, any resection and having a clinically non-functional tumour significantly increased survival (P = 0.003 and P = 0.037 respectively). The TNM stage was I in 37 patients, II in 15 patients, III in 32 patients and IV in 34 patients. There were significant differences in 5-year survival between stage I and II (88 and 85 per cent respectively) and stage III and IV (31 and 42 per cent respectively) (P = 0.010). CONCLUSION: Both classifications accurately reflect the clinical outcome of patients with pNET. The resection status may not be critical for long-term survival in patients with pNET.
Resumo:
OBJECTIVE: The aim of this study was to determine the presence and absence of acupuncture ear points in healthy neonates. DESIGN: This was a prospective observational study performed at a university teaching hospital. Subjects: The subjects were healthy neonates. We compared male and female neonates, right and left lobe, term and preterm deliveries, and cesarean sections versus vaginal deliveries. Examinations took place on the fifth day after delivery and were performed by a neuronal pen (SVESA 1070, SVESA GmbH, Munich, Germany). An integrated optical signal detected the ear points that were assigned to the Chinese ear map. MAIN OUTCOME MEASURES: This study looked at the presence and absence of acupuncture ear points in neonates. RESULTS: There were 27 male neonates and 23 female neonates. In 66% of neonates, no points at all were found. We detected 0-4 points on the right lobe and 0-2 points on the left lobe. The psychovegetative rim was the most common point in 26% of all children. No psychic points were detected. No significant differences were found between right and left ear lobes, male and female neonates, or term and preterm deliveries with respect to numbers of points or access of points. Moreover, there were no differences among modes of delivery. CONCLUSIONS: Some ear points in healthy neonates are detectable and not dependent on side of the ear lobe. Females had significantly more acupuncture points. There was an extremely significant difference in the group with 2 active earpoints between cesarean and vaginally delivered neonates. The most important point was the psychovegetative rim and the absence of psychic points in favor of the organ points. Possibly, ear points in neonates could be used for diagnostic and therapeutic options in neonates in the future.
Resumo:
BACKGROUND: Pain associated with routine procedures in NICUs is often inadequately managed. Barriers to more appropriate pain management are nurses' and physicians' knowledge and the challenges of collaborative decision-making. Few studies describe the differing perceptions of procedural pain intensity among nurses and physicians in NICUs which could complicate common decision-making. This study set out to explore the factors influencing pain intensity assessment and to gain insight into a possible pain intensity classification of routine procedures in the NICU. METHOD: A survey was conducted among 431 neonatal health care professionals from 4 tertiary level NICUs. Each routine procedure was assessed on a 10-point visual analogue scale (VAS) assuming absence of analgesia. RESULTS: Multiple ANCOVA models showed that nurses rated 19 of the 27 procedures as significantly more painful than did physicians (p<0.05). We found no differences in pain assessment based on professional experience, gender or age. Of the 27 procedures listed, 70% were rated as painful and 44% were judged very painful. Ranking and classification of the pain intensity of routine procedures were drawn up. The general ranking of the median across all procedures shows that "insertion of a thoracic drain" is assessed as the most painful procedure. CONCLUSIONS: The majority of routine procedures in an NICU are considered to be painful. Nurses generally rate procedures as more painful than do physicians. This difference in assessment deserves exploration in regard to its impact on collaborative decision-making in neonate pain management.
Resumo:
INTRODUCTION: Inhaled nitric oxide (INO) allows selective pulmonary vasodilation in acute respiratory distress syndrome and improves PaO2 by redistribution of pulmonary blood flow towards better ventilated parenchyma. One-third of patients are nonresponders to INO, however, and it is difficult to predict who will respond. The aim of the present study was to identify, within a panel of inflammatory mediators released during endotoxin-induced lung injury, specific mediators that are associated with a PaO2 response to INO. METHODS: After animal ethics committee approval, pigs were anesthetized and exposed to 2 hours of endotoxin infusion. Levels of cytokines, prostanoid, leucotriene and endothelin-1 (ET-1) were sampled prior to endotoxin exposure and hourly thereafter. All animals were exposed to 40 ppm INO: 28 animals were exposed at either 4 hours or 6 hours and a subgroup of nine animals was exposed both at 4 hours and 6 hours after onset of endotoxin infusion. RESULTS: Based on the response to INO, the animals were retrospectively placed into a responder group (increase in PaO2 > or = 20%) or a nonresponder group. All mediators increased with endotoxin infusion although no significant differences were seen between responders and nonresponders. There was a mean difference in ET-1, however, with lower levels in the nonresponder group than in the responder group, 0.1 pg/ml versus 3.0 pg/ml. Moreover, five animals in the group exposed twice to INO switched from responder to nonresponder and had decreased ET-1 levels (3.0 (2.5 to 7.5) pg/ml versus 0.1 (0.1 to 2.1) pg/ml, P < 0.05). The pulmonary artery pressure and ET-1 level were higher in future responders to INO. CONCLUSIONS: ET-1 may therefore be involved in mediating the response to INO.
Resumo:
INTRODUCTION: Sedative and analgesic drugs are frequently used in critically ill patients. Their overuse may prolong mechanical ventilation and length of stay in the intensive care unit. Guidelines recommend use of sedation protocols that include sedation scores and trials of sedation cessation to minimize drug use. We evaluated processed electroencephalography (response and state entropy and bispectral index) as an adjunct to monitoring effects of commonly used sedative and analgesic drugs and intratracheal suctioning. METHODS: Electrodes for monitoring bispectral index and entropy were placed on the foreheads of 44 critically ill patients requiring mechanical ventilation and who previously had no brain dysfunction. Sedation was targeted individually using the Ramsay Sedation Scale, recorded every 2 hours or more frequently. Use of and indications for sedative and analgesic drugs and intratracheal suctioning were recorded manually and using a camera. At the end of the study, processed electroencephalographical and haemodynamic variables collected before and after each drug application and tracheal suctioning were analyzed. Ramsay score was used for comparison with processed electroencephalography when assessed within 15 minutes of an intervention. RESULTS: The indications for boli of sedative drugs exhibited statistically significant, albeit clinically irrelevant, differences in terms of their association with processed electroencephalographical parameters. Electroencephalographical variables decreased significantly after bolus, but a specific pattern in electroencephalographical variables before drug administration was not identified. The same was true for opiate administration. At both 30 minutes and 2 minutes before intratracheal suctioning, there was no difference in electroencephalographical or clinical signs in patients who had or had not received drugs 10 minutes before suctioning. Among patients who received drugs, electroencephalographical parameters returned to baseline more rapidly. In those cases in which Ramsay score was assessed before the event, processed electroencephalography exhibited high variation. CONCLUSIONS: Unpleasant or painful stimuli and sedative and analgesic drugs are associated with significant changes in processed electroencephalographical parameters. However, clinical indications for drug administration were not reflected by these electroencephalographical parameters, and barely by sedation level before drug administration or tracheal suction. This precludes incorporation of entropy and bispectral index as target variables for sedation and analgesia protocols in critically ill patients.
Resumo:
In-cylinder pressure transducers have been used for decades to record combustion pressure inside a running engine. However, due to the extreme operating environment, transducer design and installation must be considered in order to minimize measurement error. One such error is caused by thermal shock, where the pressure transducer experiences a high heat flux that can distort the pressure transducer diaphragm and also change the crystal sensitivity. This research focused on investigating the effects of thermal shock on in-cylinder pressure transducer data quality using a 2.0L, four-cylinder, spark-ignited, direct-injected, turbo-charged GM engine. Cylinder four was modified with five ports to accommodate pressure transducers of different manufacturers. They included an AVL GH14D, an AVL GH15D, a Kistler 6125C, and a Kistler 6054AR. The GH14D, GH15D, and 6054AR were M5 size transducers. The 6125C was a larger, 6.2mm transducer. Note that both of the AVL pressure transducers utilized a PH03 flame arrestor. Sweeps of ignition timing (spark sweep), engine speed, and engine load were performed to study the effects of thermal shock on each pressure transducer. The project consisted of two distinct phases which included experimental engine testing as well as simulation using a commercially available software package. A comparison was performed to characterize the quality of the data between the actual cylinder pressure and the simulated results. This comparison was valuable because the simulation results did not include thermal shock effects. All three sets of tests showed the peak cylinder pressure was basically unaffected by thermal shock. Comparison of the experimental data with the simulated results showed very good correlation. The spark sweep was performed at 1300 RPM and 3.3 bar NMEP and showed that the differences between the simulated results (no thermal shock) and the experimental data for the indicated mean effective pressure (IMEP) and the pumping mean effective pressure (PMEP) were significantly less than the published accuracies. All transducers had an IMEP percent difference less than 0.038% and less than 0.32% for PMEP. Kistler and AVL publish that the accuracy of their pressure transducers are within plus or minus 1% for the IMEP (AVL 2011; Kistler 2011). In addition, the difference in average exhaust absolute pressure between the simulated results and experimental data was the greatest for the two Kistler pressure transducers. The location and lack of flame arrestor are believed to be the cause of the increased error. For the engine speed sweep, the torque output was held constant at 203 Nm (150 ft-lbf) from 1500 to 4000 RPM. The difference in IMEP was less than 0.01% and the PMEP was less than 1%, except for the AVL GH14D which was 5% and the AVL GH15DK which was 2.25%. A noticeable error in PMEP appeared as the load increased during the engine speed sweeps, as expected. The load sweep was conducted at 2000 RPM over a range of NMEP from 1.1 to 14 bar. The difference in IMEP values were less 0.08% while the PMEP values were below 1% except for the AVL GH14D which was 1.8% and the AVL GH15DK which was at 1.25%. In-cylinder pressure transducer data quality was effectively analyzed using a combination of experimental data and simulation results. Several criteria can be used to investigate the impact of thermal shock on data quality as well as determine the best location and thermal protection for various transducers.
Resumo:
Lung volume reduction surgery (LVRS) has been proposed for patients with severe emphysema to improve dyspnoea and pulmonary function. It is unknown, however, whether prognosis and pulmonary function in these patients can be improved compared to conservative treatment. The effect of LVRS and conservative therapy were compared prospectively in 57 patients with emphysema, who fulfilled the standard criteria for LVRS. The patients were divided into two groups according to their own decision. Patients in group 1 (n=29, eight females, mean+/-SEM 58.8+/-1.7 yrs, forced expiratory volume in one second (FEV1) 27.6+/-1.3% of the predicted value) underwent LVRS. Patients in group 2 (n=28, five females, 58.5+/-1.8 yrs, FEV1 30.8+/-1.4% pred) preferred to postpone LVRS. There were no significant differences in lung function between the two groups at baseline; however, there was a tendency towards better functional status in the control group. The control group had a better modified Medical Research Council (MMRC) dyspnea score (3.1+/-0.15 versus 3.5+/-0.1, p<0.04). Model-based comparisons were used to estimate the differences between the two groups over 18 months. Significant improvements were observed in the LVRS group compared to the control group in FEV1, total lung capacity (TLC), Residual volume (RV), MMRC dyspnea score and 6-min walking distance on all follow up visits. The estimated difference in FEV1 was 33% (95% confidence interval 13-58%; p>0.0001), in TLC 12.9% (7.9-18.8%; p>0.0001), in RV 60.9% 32.6-89.2%; p>0.0001), in 6-min walking distance 230 m (138-322 m; p<0.002) and in MMRC dyspnoea score 1.17 (0.79-1.55; p<0.0001). In conclusion, lung volume reduction surgery is more effective than conservative treatment for the improvement of dyspnoea, lung function and exercise capacity in selected patients with severe emphysema.
Resumo:
Here we investigate the expression of OCT4 human lung adenocarcinoma and bronchioloalveolar carcinoma (BAC) tumor biopsies and tumor-derived primary cell cultures. OCT4 has been detected in several human tumors suggesting a potentially critical role in tumorigenesis. We assessed the presence of OCT4 in clinical tumor samples of both adenocarcinoma and BAC at the cellular and transcriptional levels, respectively. Furthermore, we evaluated tumor-derived cell cultures for potential differences in OCT4 expression. Immunohistochemical analysis depicted OCT4 in 2 of 8 adenocarcinoma tumor samples and 3 of 5 BAC tumor samples, with no apparent difference in the degree of expression among the sections examined. These results were validated by transcript analysis. Flow cytometric assessment of 11 adenocarcinoma-derived cell cultures and 3 BAC-derived cell cultures revealed significantly higher OCT4 expression in adenocarcinoma tumors compared to their normal counterparts. This, however, was not observed in the BAC cultures. Comparative studies of OCT4 in adenocarcinoma and BAC tumor cell cultures demonstrated a dramatically higher expression in the former. The expression of OCT4 may represent a specific and effective target for therapeutic intervention in adenocarcinoma and BAC. In addition, the aberrant expression and distribution of OCT4 may indicate important parameters concerning the differences between adenocarcinoma and BAC.
Resumo:
AIMS: Lesion length remains a predictor of target lesion revascularisation and results of long lesion stenting remain poor. Sirolimus-eluting stents have been shown to perform better than paclitaxel eluting stents in long lesions. In this substudy of the LEADERS trial, we compared the performance of biolimus biodegradable polymer (BES) and sirolimus permanent polymer stents (SES) in long lesions. METHODS AND RESULTS: A total of 1,707 'all-comer' patients were randomly allocated to treatment with BES and SES. A stratified analysis of angiographic and clinical outcomes at nine months and one year, respectively was performed for vessels with lesion length <20 mm versus >20 mm (as measured by quantitative angiography).Of 1,707 patients, 592 BES patients with 831 lesions and 619 SES patients with 876 lesions had only short lesions treated. One hundred and fifty-three BES patients with 166 lesions and 151 SES patients with 162 lesions had long lesions. There were no significant differences in baseline clinical characteristics, except for higher number of patients with long lesions presenting with acute myocardial infarction in both stent groups. Long lesions tended to have lower MLD and greater percent diameter stenosis at baseline than short lesions. Late loss was greater for long lesions than short lesions. There was no statistically significant difference in late loss between BES and SES stents (0.32+/-0.69 vs 0.24+/-0.57, p=0.59). Binary in-segment restenosis was present in 23.2% versus 13.1% of long lesions treated with BES and SES, respectively (p=0.042). In patients with long lesions, the overall MACE rate was similar for BES and SES (17% vs 14.6%; p=0.62). There was a trend towards higher overall TLR rate with BES (12.4 % vs 6.0%; HR=2.06; p=0.07) and clinically driven TLR (10.5% vs 5.3%: HR 1.94; p=0.13). Rates of definite stent thrombosis were 3.3% in the long lesion group and 1.3-1.7 % in the short lesion group. CONCLUSIONS: BES and SES appear similar with respect to MACE in long lesions in this "all-comer" patient population. However, long lesions tended to have a higher rate of binary in-segment restenosis and TLR following BES than SES treatment.
Resumo:
Plates used for fracture fixation produce vascular injury to the underlying cortical bone. During the recovery of the blood supply, temporary osteoporosis is observed as a result of Haversian remodeling of the necrotic bone. This process temporarily reduces the strength of the bone. We tackled the postulate that quantitative differences exist between animal species, and in different bones within the same species, due to variations in the relative importance of the endosteal and periosteal blood supplies. Using implants scaled to the size of the bone, we found comparable cortical vascular damage in the sheep and in the dog, and in the tibia and femur of each animal. We observed a significant reduction in cortical vascular damage using plates that had a smaller contact area with the underlying bone. No significant difference in cortical vascular damage was noted in animals of different ages.
Resumo:
The purpose of this retrospective study was to compare patterns of vertebral fractures and luxations in 42 cats and 47 dogs, and to evaluate the impact of species-related differences on clinical outcome. Data regarding aetiology, neurological status, radiographic appearance and follow-up were compared between the groups. The thoracolumbar (Th3-L3) area was the most commonly affected location in both cats (49%) and dogs (58%). No lesions were observed in the cervical vertebral segments in cats, and none of the cats showed any signs of a Schiff-Sherrington syndrome. Vertebral luxations were significantly more frequent in dogs (20%) than in cats (6%), whereas combined fracture-luxations occurred significantly more often in cats (65%) than in dogs (37%). Caudal vertebral segment displacement was mostly dorsal in cats and ventral in dogs, with a significant difference in direction between cats and large dogs. The clinical outcome did not differ significantly between the two populations, and was poor in most cases (cats: 61%; dogs: 56%). The degree of dislocation and axis deviation were both significantly associated with a worse outcome in dogs, but not in cats. Although several differences in vertebral fractures and luxation patterns exist between cats and dogs, these generally do not seem to affect outcome.
Resumo:
Since 2000, a surprisingly high number of macroscopical gonad alterations has been reported in whitefish (Coregonus spp.) from Lake Thun, Switzerland. This unique phenomenon is still unexplained and has received much public attention. As one possible trigger for these effects, the presence of persistent, bioaccumulative and toxic compounds acting as endocrine disruptors in the lake has been discussed. In this study, concentrations of selected persistent organic pollutants were examined in two morphs of whitefish from Lake Thun and their link to the observed abnormalities was investigated. Analyzed compound classes included polychlorinated biphenyls, polychlorinated dibenzo-p-dioxins and dibenzofurans, polychlorinated naphthalenes, polybrominated diphenyl ethers and hexabromocyclododecanes. The target substances were identified in all samples and concentrations of the analyzed compounds were highly correlated among each other. These correlations show that the analyzed substances have the same distribution pattern throughout the lake and that uptake, accumulation and elimination processes are similar. Significant differences in contaminant levels within the samples existed between the two analyzed morphs of whitefish, most likely due to different age, food patterns and growth rate. No difference in contaminant levels was observed between fish with abnormal gonads and fish with normal gonads, suggesting no causal link between the investigated lipophilic organohalogen compounds present in fish and the observed gonad abnormalities in whitefish from Lake Thun. A comparison to existing data shows that concentrations in Lake Thun whitefish are at the lower bound of contaminant levels in whitefish from Swiss lakes or from European waters.
Resumo:
Chronic obstructive pulmonary disease (COPD) is characterized by emphysema and chronic bronchitis and is a leading cause of morbidity and mortality worldwide. Tobacco smoke and deficiency in α1-antitrypsin (AAT) are the most prominent environmental and genetic risk factors, respectively. Yet the pathogenesis of COPD is not completely elucidated. Disease progression appears to include a vicious circle driven by self-perpetuating lung inflammation, endothelial and epithelial cell death, and proteolytic degradation of extracellular matrix proteins. Like AAT, serpinB1 is a potent inhibitor of serine proteases including neutrophil elastase and cathepsin G. Because serpinB1 is expressed in myeloid and lung epithelial cells and is protective during lung infections, we investigated the role of serpinB1 in preventing age-related and cigarette smoke-induced emphysema in mice. Fifteen-month-old mice showed increased lung volume and decreased pulmonary function compared with young adult mice (3 mo old), but no differences were observed between serpinB1-deficient (KO) and wild-type (WT) mice. Chronic exposure to secondhand cigarette smoke resulted in structural emphysematous changes compared with respective control mice, but no difference in lung morphometry was observed between genotypes. Of note, the different pattern of stereological changes induced by age and cigarette smoke suggest distinct mechanisms leading to increased airway volume. Finally, expression of intracellular and extracellular protease inhibitors were differently regulated in lungs of WT and KO mice following smoke exposure; however, activity of proteases was not significantly altered. In conclusion, we showed that, although AAT and serpinB1 are similarly potent inhibitors of neutrophil proteases, serpinB1 deficiency is not associated with more severe emphysema.