962 resultados para cost efficiency
Resumo:
In spite of their wide application in comminution circuits, hydrocyclones have at least one significant disadvantage in that their operation inherently tends to return the fine denser liberated minerals to the grinding mill. This results in unnecessary overgrinding which adds to the milling cost and can adversely affect the efficiency of downstream processes. In an attempt to solve this problem, a three-product cyclone has been developed at the Julius Kruttschnitt Mineral Research Centre (JKMRC) to generate a second overflow in which the fine dense liberated minerals can be selectively concentrated for further treatment. In this paper, the design and operation of the three-product cyclone are described. The influence of the length of the second vortex finder on the performance of a 150-mm unit treating a mixture of magnetite and silica is investigated. Conventional cyclone tests were also conducted under similar conditions. Using the operational performance data of the three-product and conventional cyclones, it is shown that by optimising the length of the second vortex finder, the amount of fine dense mineral particles that reports to the three-product cyclone underflow can be reduced. In addition, the three-product cyclone can be used to generate middlings stream that may be more suitable for flash flotation than the conventional cyclone underflow, or alternatively, could be classified with a microscreen to separate the valuables from the gangue. At the same time, a fines stream having similar properties to those of the conventional overflow can be obtained. Hence, if the middlings stream was used as feed for flash flotation or microscreening, the fines stream could be used in lieu of the conventional overflow without compromising the feed requirements for the conventional flotation circuit. Some of the other potential applications of the new cyclone are described. (C) 2003 Elsevier Science B.V. All rights reserved.
Resumo:
BP Refinery (Bulwer Island) Ltd (BP) located on the eastern Australian coast is currently undergoing a major expansion as a part of the Queensland Clean Fuels Project. The associated wastewater treatment plant upgrade will provide a better quality of treated effluent than is currently possible with the existing infrastructure, and which will be of a sufficiently high standard to meet not only the requirements of imposed environmental legislation but also BP's environmental objectives. A number of challenges were faced when considering the upgrade, particularly; cost constraints and limited plot space, highly variable wastewater, toxicity issues, and limited available hydraulic head. Sequencing Batch Reactor (SBR) Technology was chosen for the lagoon upgrade based on the following; SBR technology allowed a retro-fit of the existing earthen lagoon without the need for any additional substantial concrete structures, a dual lagoon system allowed partial treatment of wastewaters during construction, SBRs give substantial process flexibility, SBRs have the ability to easily modify process parameters without any physical modifications, and significant cost benefits. This paper presents the background to this application, an outline of laboratory studies carried out on the wastewater and details the full scale design issues and methods for providing a cost effective, efficient treatment system using the existing lagoon system.
Resumo:
Effects of soil water availability on transpiration efficiency (WUET), instantaneous water use efficiency (WUEi) and carbon isotope composition (delta(13)C) were investigated in 7-month-old plants of humid coastal (Gympie) and dry inland ( Hungry Hills) provenances of Eucalyptus cloeziana F. Muell. and in a dry inland provenance of E. argophloia Blakely (Chinchilla), supplied with 100 (W-100), 70 (W-70) and 50% (W-50) of their water requirements. At W-100, WUET of the three provenances were not significantly different but as available soil moisture decreased, E. argophloia produced greater biomass and demonstrated significantly higher WUET than either E. cloeziana provenance. Midday WUEi was not significantly affected by watering regime within each provenance but was lowest in E. argophloia. A decrease in soil water availability caused a consistent increase in delta(13)C values in all three provenances; however, delta(13)C values of E. argophloia in all three water regimes were significantly lower than those of E. cloeziana provenances, which did not differ significantly from each other. For all three provenances, delta(13)C was not correlated with WUEi but height and root collar diameter were negatively correlated to delta(13)C. There was little evidence of differences in delta(13)C, WUET and WUEi between E. cloeziana provenances but clear differences between E. cloeziana and E. argophloia. The high WUET, low WUEi and low delta(13)C for E. argophloia may have implications in the selection of Eucalyptus provenances for commercial forestry in low-rainfall regions.
Resumo:
O presente artigo aborda a quest??o da apura????o de custos de servi??os p??blicos a partir da perspectiva do processo or??ament??rio no setor p??blico. Nesse sentido, o objetivo principal do trabalho consiste em explicitar uma sistem??tica de an??lise e apura????o de custos de servi??os p??blicos que seja adaptada ao processo or??ament??rio do setor p??blico brasileiro e, assim, contribuir para a obten????o da efici??ncia alocativa e efici??ncia operacional. A sistem??tica de apura????o de custos aqui proposta ?? totalmente compat??vel com os sistemas gerenciais de informa????o utilizados pelo Governo e tem baixo custo de operacionaliza????o porque n??o implica mudan??as apreci??veis nos sistemas de informa????o em uso e na forma de registro das informa????es na contabilidade p??blica. Por fim, a sistem??tica de apura????o de custos de servi??os p??blicos proposta atende ?? Lei de Responsabilidade Fiscal e a complementa quanto ?? apura????o de custos de servi??os e produtos do setor p??blico.
Resumo:
A baciloscopia é o principal método diagnóstico da tuberculose (TB) em razão do seu baixo custo, rapidez e facilidade de execução. Porém sua sensibilidade é baixa, principalmente nas formas paucibacilares da doença. Nesse sentido, novas metodologias que resultem no aumento da sensibilidade da baciloscopia tornam-se absolutamente necessárias. Neste estudo, nos propusemos a aprimorar e padronizar o sistema de filtração BacFil e avaliar sua performance e acurácia em amostras paucibacilares (lavado broncoalveolar). Para alcançar esses objetivos desenvolvemos o estudo em duas fases. Na primeira fase, foram realizados ensaios para definir: 1) utilização de membranas brancas para visualização de BAAR corados por Auramina-O; 2) aumento do volume de NALC, utilização de pérolas de vidro no processo de digestão das amostras e mudança no sistema do suporte do pré-filtro; 3) meios de fixação da membrana de filtração na lâmina de microscopia; 4) limite de detecção da técnica; 5) aumento do volume de NaOCl e a influência desse aumento na visualização de BAAR na membrana. Verificou-se que: a membrana de policarbonato branca tem a mesma eficiência da membrana de policarbonato preta na visualização de BAAR fluorescentes; o método modificado utilizando maior concentração de NALC, pérolas de vidro e sistema de pré-filtro baseado em orifícios obteve 98% de passagem das amostras pelo sistema; a melhor forma de fixação da membrana na lâmina foi obtida por intermédio da utilização de fita dupla face; o limite de detecção da técnica de filtração utilizando o sistema BacFil versão 6.0 foi de 2 a 9 BAAR por mililitro de suspensão bacteriana com D.O de 0,250 ± 0,01 a 625nm; o aumento da concentração de NaOCl para 10% ajuda na passagem de um maior volume de amostra pelo sistema, porém ocasiona a diminuição da quantidade BAAR na membrana de filtração após o período necessário para todo o processo. Na segunda fase foi avaliado acurácia da técnica padronizada em 101 amostras de lavado broncoalveolar (LBA) de pacientes com suspeita de TB provenientes do Hospital Universitário Cassiano Antônio de Moraes. Observou-se que a sensibilidade da técnica de filtração (BacFil versão 6.0) foi de 76% e especificidade de 95%. A sensibilidade obtida foi significativamente maior do que a observada na baciloscopia após centrifugação que foi de 59% (p = 0,001). No entanto, constatou-se uma diminuição de especificidade na técnica de filtração (95%) em relação a técnica de 8 centrifugação (99%). Concluímos que as modificações realizadas nos sistema de filtração permitiu sanar os problemas técnicos apresentados nas versões anteriores e aumentar a sensibilidade da baciloscopia de amostras paucibacilares (lavado broncoalveolar) para o diagnóstico da TB pulmonar.
Resumo:
The energy harvesting efficiency of electrospun poly(vinylidene fluoride), its copolymer vinylidene fluoride-trifluoroethylene and composites of the later with piezoelectric BaTiOon interdigitated electrodes has been investigated. Further, a study of the influence of the electrospinning processing parameters on the size and distribution of the composites fibers has been performed. It is found that the best energy harvesting performance is obtained for the pure poly(vinylidene fluoride) fibers, with power outputs up to 0.03 W and 25 W under low and high mechanical deformation. The copolymer and the composites show reduced power output due to increased mechanical stiffness. The obtained values, among the largest found in the literature, the easy processing and the low cost and robustness of the polymer, demonstrate the applicability of the developed system.
Resumo:
Nitrogen has a complex dynamics in the soil-plant-atmosphere system. N fertilizers are subject to chemical and microbial transformations in soils that can result in significant losses. Considering the cost of fertilizers, the adoption of good management practices like fertigation could improve the N use efficiency by crops. Water balances (WB) were applied to evaluate fertilizer N leaching using 15N labeled urea in west Bahia, Brazil. Three scenarios (2008/2009) were established: i) rainfall + irrigation the full year, ii) rainfall only; and iii) rainfall + irrigation only in the dry season. The water excess was considered equal to the deep drainage for the very flat area (runoff = 0) with a water table located several meters below soil surface (capillary rise = 0). The control volume for water balance calculations was the 0 - 1 m soil layer, considering that it involves the active root system. The water drained below 1 m was used to estimate fertilizer N leaching losses. WB calculations used the mathematic model of Penman-Monteith for evapotranspiration, considering the crop coefficient equal to unity. The high N application rate associated to the high rainfall plus irrigation was found to be the main cause for leaching, which values were 14.7 and 104.5 kg ha-1 for the rates 400 and 800 kg ha-1 of N, corresponding to 3.7 and 13.1 % of the applied fertilizer, respectively.
Resumo:
Studies on nutritional efficiency of phosphorus in conilon coffee plants are important tools to unravel the high limitation that natural low levels of this nutrient in soil impose to these species cultivars. Therefore, this study aimed at evaluating the nutritional efficiency and the response to phosphorus of conilon coffee clones. Plants were managed during 150 days in pots containing 10 dm³ of soil, in greenhouse. A factorial scheme 13 x 2 was used, with three replications, being the factors: 13 clones constituting the clonal cultivar "Vitória Incaper 8142" and two levels of phosphate fertilization (0% and 150% of the P2O5 usualy recommended), in a completely randomized design (CRD). The results indicate a differentiated response of dry matter production and of phosphorus content on each level of phosphate fertilization for the conilon coffee clones and that CV-04, CV-05 and CV-08 clones are nutritionally efficient and responsive to the phosphate fertilization.
Resumo:
This paper explores the main determinants of the use of the cost accounting system (CAS) in Portuguese local government (PLG). Regression analysis is used to study the fit of a model of accounting changes in PLG, focused on cost accounting systems oriented to activities and outputs. Based on survey data gathered from PLG, we have found that the use of information in decision-making and external reporting is still a mirage. We obtain evidence about the influence of the internal organizational context (especially the lack of support and difficulties in the CAS implementation) in the use for internal purposes, while the institutional environment (like external pressures to implement the CAS) appears to be more deterministic of the external use. Results strengthen the function of external reporting to legitimate the organization’s activities to external stakeholders. On the other hand, some control variables (like political competition, usefulness and experience) also evidence some explanatory power in the model. Some mixed results were found that appeal to further research in the future. Our empirical results contribute to understand the importance of interconnecting the contingency and institutional approaches to gain a clear picture of cost accounting changes in the public sector.
Resumo:
When the electrostatic spraying is used correctly, it provides advantages over conventional systems, however many factors can affect the system efficiency. Therefore, the objective of this study was to evaluate the charge/mass ratio (Q/M) at different spraying distances (0, 1, 2, 3, 4 and 5 m), and the liquid deposition efficiency on the target. Evaluating the Q/M ratio the Faraday cage method was used and to evaluate the liquid deposition efficiency the artificial targets were positioned longitudinally and transversely to the spray jet. It was found that the spraying distance affects the Q/M ratio, consequently, the liquid deposition efficiency. For the closest distance to the target the Q/M ratio was 4.11 mC kg-1, and at distances of 1, 2, 3, 4 and 5 m, the ratio decreased to 1.38, 0.64, 0.31, 0.17 and 0.005 mC kg-1, respectively. For the liquid deposition, the electrostatic system was affected by the target orientation and spraying distance. The target transversely to the jet of liquid did not improve the liquid deposition, but longitudinally increased the deposition up to 3 meters of distance.
Resumo:
NBPT (N-(n-butyl) thiophosphoric triamide), a urease inhibitor, has been reported as one of the most promising compounds to maximize urea nitrogen use in agricultural systems. The objective of this study was to evaluate the performance of irrigated wheat fertilized with urea or urea + NBPT as single or split application. The experiment was conducted from June to October 2006 in Viçosa, MG, Brazil. The experimental design followed a 2×2 factorial scheme, in which urea or urea + NBPT were combined with two modes of application: full dose at sowing (60kg ha-1) or split (20kg ha-1 at sowing + 40kg ha-1 as topdressing at tillering), in randomized blocks with ten replications. The split application of nitrogen fertilization does not improve the yield wheat under used conditions. The use of urease inhibitor improves the grain yield of wheat crop when urea is applied in topdressing at tillering, but its use does not promote difference when urea is applied in the furrow at planting.
Resumo:
The long-lived flowers of orchids increase the chances of pollination and thus the reproductive success of the species. However, a question arises: does the efficiency of pollination, expressed by fruit set, vary with the flower age? The objective of this study was to verify whether the flower age of Corymborkis flava(Sw.) Kuntze affects pollination efficiency. The following hypotheses were tested: 1) the fruit set of older flowers is lower than that of younger ones; 2) morphological observations (perianth and stigmatic area), stigma receptivity test by using a solution of hydrogen peroxide and hand-pollination tests are equally effective in defining the period of stigmatic receptivity. Flowers were found to be receptive from the first to the fourth day of anthesis. Fruit set of older flowers (third and fourth day) was lower than that of younger flowers. Morphological observations, the stigma receptivity test and hand-pollinations were equally effective in defining the period of stigmatic receptivity. However, to evaluate the maximum degree of stigma receptivity of orchid species with long-lived flowers, we recommend hand-pollinations, beyond the period of receptivity.
Resumo:
ABSTRACT The efficiency of nitrogen fertilizer in corn is usually low, negatively affecting plant nutrition, the economic return, and the environment. In this context, a variable rate of nitrogen, prescribed by crop sensors, has been proposed as an alternative to the uniform rate of nitrogen traditionally used by farmers. This study tested the hypothesis that variable rate of nitrogen, prescribed by optical sensor, increases the nitrogen use efficiency and grain yield as compared to uniform rate of nitrogen. The following treatments were evaluated: 0; 70; 140; and 210 kg ha-1 under uniform rate of nitrogen, and 140 kg ha -1 under variable rate of nitrogen. The nitrogen source was urea applied on the soil surface using a distributor equipped with the crop sensor. In this study, the grain yield ranged from 10.2 to 15.5 Mg ha-1, with linear response to nitrogen rates. The variable rate of nitrogen increased by 11.8 and 32.6% the nitrogen uptake and nitrogen use efficiency, respectively, compared to the uniform rate of nitrogen. However, no significant increase in grain yield was observed, indicating that the major benefit of the variable rate of nitrogen was reducing the risk of environmental impact of fertilizer.
Resumo:
Quantitative analysis of cine cardiac magnetic resonance (CMR) images for the assessment of global left ventricular morphology and function remains a routine task in clinical cardiology practice. To date, this process requires user interaction and therefore prolongs the examination (i.e. cost) and introduces observer variability. In this study, we sought to validate the feasibility, accuracy, and time efficiency of a novel framework for automatic quantification of left ventricular global function in a clinical setting.