878 resultados para computer-assisted system
Comparison of three commercially available radio frequency coils for human brain imaging at 3 Tesla.
Resumo:
OBJECTIVE: To evaluate a transverse electromagnetic (TEM), a circularly polarized (CP) (birdcage), and a 12-channel phased array head coil at the clinical field strength of B0 = 3T in terms of signal-to-noise ratio (SNR), signal homogeneity, and maps of the effective flip angle alpha. MATERIALS AND METHODS: SNR measurements were performed on low flip angle gradient echo images. In addition, flip angle maps were generated for alpha(nominal) = 30 degrees using the double angle method. These evaluation steps were performed on phantom and human brain data acquired with each coil. Moreover, the signal intensity variation was computed for phantom data using five different regions of interest. RESULTS: In terms of SNR, the TEM coil performs slightly better than the CP coil, but is second to the smaller 12-channel coil for human data. As expected, both the TEM and the CP coils show superior image intensity homogeneity than the 12-channel coil, and achieve larger mean effective flip angles than the combination of body and 12-channel coil with reduced radio frequency power deposition. CONCLUSION: At 3T the benefits of TEM coil design over conventional lumped element(s) coil design start to emerge, though the phased array coil retains an advantage with respect to SNR performance.
Resumo:
RATIONALE AND OBJECTIVES: Recent developments of magnetic resonance imaging enabled free-breathing coronary MRA (cMRA) using steady-state-free-precession (SSFP) for endogenous contrast. The purpose of this study was a systematic comparison of SSFP cMRA with standard T2-prepared gradient-echo and spiral cMRA. METHODS: Navigator-gated free-breathing T2-prepared SSFP-, T2-prepared gradient-echo- and T2-prepared spiral cMRA was performed in 18 healthy swine (45-68 kg body-weight). Image quality was investigated subjectively and signal-to-noise ratio (SNR), contrast-to-noise ratio (CNR) and vessel sharpness were compared. RESULTS: SSFP cMRA allowed for high quality cMRA during free breathing with substantial improvements in SNR, CNR and vessel sharpness when compared with standard T2-prepared gradient-echo imaging. Spiral imaging demonstrated the highest SNR while image quality score and vessel definition was best for SSFP imaging. CONCLUSION: Navigator-gated free-breathing T2-prepared SSFP cMRA is a promising new imaging approach for high signal and high contrast imaging of the coronary arteries with improved vessel border definition.
Resumo:
With increasing costs for conducting surveys, many survey agencies resort to implementing call strategies. Obtaining contact in panel surveys as early as possible, without annoying people by contacting them at undesired times and ultimately causing them to refuse, requires using efficient call time strategies. In this research, the author uses call data from the Swiss Household Panel (SHP), a centralized Computer Assisted Telephone Interview (CATI) survey with a randomized (experimental) call-household assignment. Using random effects models, the author analyzes the efficiency gains of obtaining initial contact by assigning optimal times to first calls, and times and spacing to second and later calls depending on household sociodemography and prior call patterns. The author concludes with some recommendations for making early and successful contact during fieldwork.
Resumo:
Methods are presented to map complex fiber architectures in tissues by imaging the 3D spectra of tissue water diffusion with MR. First, theoretical considerations show why and under what conditions diffusion contrast is positive. Using this result, spin displacement spectra that are conventionally phase-encoded can be accurately reconstructed by a Fourier transform of the measured signal's modulus. Second, studies of in vitro and in vivo samples demonstrate correspondence between the orientational maxima of the diffusion spectrum and those of the fiber orientation density at each location. In specimens with complex muscular tissue, such as the tongue, diffusion spectrum images show characteristic local heterogeneities of fiber architectures, including angular dispersion and intersection. Cerebral diffusion spectra acquired in normal human subjects resolve known white matter tracts and tract intersections. Finally, the relation between the presented model-free imaging technique and other available diffusion MRI schemes is discussed.
Resumo:
A fully-automated 3D image analysis method is proposed to segment lung nodules in HRCT. A specific gray-level mathematical morphology operator, the SMDC-connection cost, acting in the 3D space of the thorax volume is defined in order to discriminate lung nodules from other dense (vascular) structures. Applied to clinical data concerning patients with pulmonary carcinoma, the proposed method detects isolated, juxtavascular and peripheral nodules with sizes ranging from 2 to 20 mm diameter. The segmentation accuracy was objectively evaluated on real and simulated nodules. The method showed a sensitivity and a specificity ranging from 85% to 97% and from 90% to 98%, respectively.
Resumo:
PURPOSE: To investigate the potential of free-breathing 3D steady-state free precession (SSFP) imaging with radial k-space sampling for coronary MR-angiography (MRA), coronary projection MR-angiography and coronary vessel wall imaging. MATERIALS AND METHODS: A navigator-gated free-breathing T2-prepared 3D SSFP sequence (TR = 6.1 ms, TE = 3.0 ms, flip angle = 120 degrees, field-of-view = 360 mm(2)) with radial k-space sampling (384 radials) was implemented for coronary MRA. For projection coronary MRA, this sequence was combined with a 2D selective aortic spin tagging pulse. Coronary vessel wall imaging was performed using a high-resolution inversion-recovery black-blood 3D radial SSFP sequence (384 radials, TR = 5.3 ms, TE = 2.7 ms, flip angle = 55 degrees, reconstructed resolution 0.35 x 0.35 x 1.2 mm(3)) and a local re-inversion pulse. Six healthy volunteers (two for each sequence) were investigated. Motion artifact level was assessed by two radiologists. Results: In coronary MRA, the coronary lumen was displayed with a high signal and high contrast to the surrounding lumen. Projection coronary MRA demonstrated selective visualization of the coronary lumen while surrounding tissue was almost completely suppressed. In coronary vessel wall imaging, the vessel wall was displayed with a high signal when compared to the blood pool and the surrounding tissue. No visible motion artifacts were seen. Conclusion: 3D radial SSFP imaging enables coronary MRA, coronary projection MRA and coronary vessel wall imaging with a low motion artifact level.
Resumo:
This paper addresses a fully automatic landmarks detection method for breast reconstruction aesthetic assessment. The set of landmarks detected are the supraesternal notch (SSN), armpits, nipples, and inframammary fold (IMF). These landmarks are commonly used in order to perform anthropometric measurements for aesthetic assessment. The methodological approach is based on both illumination and morphological analysis. The proposed method has been tested with 21 images. A good overall performance is observed, although several improvements must be achieved in order to refine the detection of nipples and SSNs.
Resumo:
Dystonia is associated with impaired somatosensory ability. The electrophysiological method of repetitive transcranial magnetic stimulation (rTMS) can be used for noninvasive stimulation of the human cortex and can alter cortical excitability and associated behavior. Among others, rTMS can alter/improve somatosensory discrimation abilities, as shown in healthy controls. We applied 5Hz-rTMS over the left primary somatosensory cortex (S1) in 5 patients with right-sided writer's dystonia and 5 controls. We studied rTMS effects on tactile discrimination accuracy and concomitant rTMS-induced changes in hemodynamic activity measured by functional magnetic resonance imaging (fMRI). Before rTMS, patients performed worse on the discrimination task than controls even though fMRI showed greater task-related activation bilaterally in the basal ganglia (BG). In controls, rTMS led to improved discrimination; fMRI revealed this was associated with increased activity of the stimulated S1, bilateral premotor cortex and BG. In dystonia patients, rTMS had no effect on discrimination; fMRI showed similar cortical effects to controls except for no effects in BG. Improved discrimination after rTMS in controls is linked to enhanced activation of S1 and BG. Failure of rTMS to increase BG activation in dystonia may be associated with the lack of effect on sensory discrimination in this group and may reflect impaired processing in BG-S1 connections. Alternatively, the increased BG activation seen in the baseline state without rTMS may reflect a compensatory strategy that saturates a BG contribution to this task.
Resumo:
Evaluation of segmentation methods is a crucial aspect in image processing, especially in the medical imaging field, where small differences between segmented regions in the anatomy can be of paramount importance. Usually, segmentation evaluation is based on a measure that depends on the number of segmented voxels inside and outside of some reference regions that are called gold standards. Although some other measures have been also used, in this work we propose a set of new similarity measures, based on different features, such as the location and intensity values of the misclassified voxels, and the connectivity and the boundaries of the segmented data. Using the multidimensional information provided by these measures, we propose a new evaluation method whose results are visualized applying a Principal Component Analysis of the data, obtaining a simplified graphical method to compare different segmentation results. We have carried out an intensive study using several classic segmentation methods applied to a set of MRI simulated data of the brain with several noise and RF inhomogeneity levels, and also to real data, showing that the new measures proposed here and the results that we have obtained from the multidimensional evaluation, improve the robustness of the evaluation and provides better understanding about the difference between segmentation methods.
Resumo:
A new quantitative approach of the mandibular sexual dimorphism, based on computer-aided image analysis and elliptical Fourier analysis of the mandibular outline in lateral view is presented. This method was applied to a series of 117 dentulous mandibles from 69 male and 48 female individuals native of Rhenish countries. Statistical discriminant analysis of the elliptical Fourier harmonics allowed the demonstration of a significant sexual dimorphism in 97.1% of males and 91.7% of females, i.e. in a higher proportion than in previous studies using classical metrical approaches. This original method opens interesting perspectives for increasing the accuracy of sex identification in current anthropological practice and in forensic procedures.
Resumo:
MRI tractography is the mapping of neural fiber pathways based on diffusion MRI of tissue diffusion anisotropy. Tractography based on diffusion tensor imaging (DTI) cannot directly image multiple fiber orientations within a single voxel. To address this limitation, diffusion spectrum MRI (DSI) and related methods were developed to image complex distributions of intravoxel fiber orientation. Here we demonstrate that tractography based on DSI has the capacity to image crossing fibers in neural tissue. DSI was performed in formalin-fixed brains of adult macaque and in the brains of healthy human subjects. Fiber tract solutions were constructed by a streamline procedure, following directions of maximum diffusion at every point, and analyzed in an interactive visualization environment (TrackVis). We report that DSI tractography accurately shows the known anatomic fiber crossings in optic chiasm, centrum semiovale, and brainstem; fiber intersections in gray matter, including cerebellar folia and the caudate nucleus; and radial fiber architecture in cerebral cortex. In contrast, none of these examples of fiber crossing and complex structure was identified by DTI analysis of the same data sets. These findings indicate that DSI tractography is able to image crossing fibers in neural tissue, an essential step toward non-invasive imaging of connectional neuroanatomy.
Resumo:
We present a segmentation method for fetal brain tissuesof T2w MR images, based on the well known ExpectationMaximization Markov Random Field (EM- MRF) scheme. Ourmain contribution is an intensity model composed of 7Gaussian distribution designed to deal with the largeintensity variability of fetal brain tissues. The secondmain contribution is a 3-steps MRF model that introducesboth local spatial and anatomical priors given by acortical distance map. Preliminary results on 4 subjectsare presented and evaluated in comparison to manualsegmentations showing that our methodology cansuccessfully be applied to such data, dealing with largeintensity variability within brain tissues and partialvolume (PV).
Resumo:
La plataforma ACME (Avaluació Continuada i Millora de l’Ensenyament) va ser creada l’any 1998 per un grup de professors del departament d’Informàtica i Matemàtica Aplicada de la Universitat de Girona.L’ACME es va concebre com una plataforma d’e-learning, és a dir, un sistema que mitjançant l’ús d’Internet afavorís l’aprenentatge, permeten la interactivitat entre alumne i professor sobre un temari comú.Actualment l’ACME s’utilitza com a complement a les classes presencials, on el professor exposa de manera magistral els conceptes i resol algun exercici a mode d’exemple, per tal que després l’alumne, utilitzant la plataforma ACME, intenti resoldre els exercicis proposats pel professorL’objectiu d’aquest Projecte Final de Carrera és desenvolupar l’anàlisi, disseny i implementació de les modificacions necessàries a incorporar a la plataforma ACME per tal de generar documents PDF dels exercicis de l’ACME. El projecte consta de tres parts: Permetre que l’alumne sigui capaç d’obtenir un fitxer en el qual hi hagin tots els exercicis de l’assignatura escollida, El professor també podrà obtenir el dossier d’un alumne en concret, permetre que el professor pugui generar un dossier de problemes base a partir dels exercicis que hagi seleccionat del repositori i permetre que el professor pugui generar un conjunt de dossiers de problemes per a després repartir entre els seus alumnes
Resumo:
La Universitat de Girona, i més concretament el Departament d’Informàtica i Matemàtica Aplicada, ja fa uns anys que ha posat en marxa el Projecte Avaluació Continuada i Millora de l’Ensenyament, també anomenat ACME. Aquest projecte és una plataforma d'e-learning, és a dir, un sistema d’aprenentatge a través de la xarxa que potencia la col•laboració digital i el bescanvi d’informació entre alumne i professor. El creixement que ha experimentat la plataforma, ha estat possible gràcies al disseny modular de l’aplicació, on cada nova funcionalitat que estava essent desenvolupada evolucionava de manera independent a la resta de la plataforma i sense comprometre’n el funcionament. Per afegir un nou mòdul a l’ACME, s’utilitzen els mòduls de base que confereixen l'estructura a la plataforma i les eines per incorporar nous mòduls, amb el que la implantació d’aquests a la plataforma és d’elevada senzillesa. Actualment, la majoria de les assignatures de primer del Grau d’Informàtica ja disposen d’exercicis adaptats a la plataforma, el que dóna una uniformitat en les eines i plataformes que utilitzen els alumnes en la seva formació. Però no hi són totes les assignatures, falta incloure l’assignatura de Lògica a la plataforma. D’aquesta manera, tant els alumnes com els professors de l’assignatura, podran treure profit dels beneficis esmentats que aporta l’ACME. Concretament, a l’assignatura de Lògica es disposava d’uns aplicatius a la plataforma Moodle de la Universitat de Girona on es guiava a l’alumne en la resolució dels exercicis. Aquest mètode és molt interessant com a mètode pedagògic per a l’aprenentatge inicial de l’assignatura, però no representa un repte real on els alumnes hagin d’aplicar els seus coneixements per a la seva realització. Els alumnes també disposaven d’un dossier on se’ls proposava uns exercicis molt complets, i a les pàgines finals d’aquest se’ls donava la solució. Aleshores, de manera voluntària els alumnes realitzaven els exercicis i comprovaven amb la solució si havien aprés a resoldre’ls. Per tant, tant els responsables de l'assignatura de Lògica com els responsables de la plataforma ACME van veure que es podrien desenvolupar eines a l'ACME per tal de corregir de forma automàtica els exercicis de l'assignatura. Incorporar l’assignatura de Lògica a l’ACME permet que els alumnes es vegin més involucrats a fer exercicis durant els curs de manera continuada, gràcies als terminis d’entrega, i facilita als professors la seva tasca deslliurant-los de les correccions i oferint-los-hi eines de seguiment