956 resultados para chemical water treatment


Relevância:

80.00% 80.00%

Publicador:

Resumo:

In the state of Rio Grande do Norte (RN), Brazil, there are about 80 sewage treatment systems being the predominant technology waste stabilization ponds. The Baldo s WWTP , due to its location and low availability of area, was designed as a hybrid conventional system (UASB reactor followed by activated sludge with biodiscs) at a tertiary level, being the most advanced WWTP in the State and also with the larger treatment capacity (1620 m3/h) .The paper presents the results of its performance based on samples collections from May to December 2012. Composite samples of the effluent of the grit chamber, UASB reactors, anoxic chambers, aeration tanks and treated effluent were collected weekly, every 4 hours for 24 hours. The results showed that the WWTP effluent presented adequate ranges of temperatures, pH and DO, however removal efficiencies of BOD and TSS were below the predicted by design. The UASB reactors also showed removals of BOD and TSS less than expected, due to the accumulation of sludge in the reactors, which eventually, was washed out in the effluent. The nitrification process was not satisfactory mainly due to problems in the oxygen distribution in the aeration tanks. The removal of ammonia and TKN were high, probably by the assimilation process

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Slow sand filtration is an efficient water treatment technique used for treating surface water with relatively low levels of contamination. Despite the slow sand filtration at pathogen, algae and cyanobacteria removal efficiency, it has some restrictions in relation to the required area for slow filters, and the cleaning activities for the filters and the stone pre-filters when used in the treatment. This research evaluated during 120 days the use of non woven & sand pre-filtration columns as part of a slow filtration process for the apparent color, turbidity, algae, cyanobacteria, phytoflagellates and diatomaceous. The columns shown an efficient removal of the monitored parameters and demonstrated as a vantage their faster and easier cleaning process and less awkward than the required to the stone pre-filters. The turbidity removal efficiency increased progressively during the experiment, especially after the first 35 days of the start; the apparent color removal by the pre-filtration columns was of 85%, and working together with the polishing of activated carbon columns was up to 95; the diatomaceous, phytoflagellates, algae and cyanobacteria removal by the columns achieve a weekly average of 95%, its recommended to use filtration rates lower to 1,5m(3)/m(2)/d.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Water treatment uses chlorine for disinfection causing formation of trihalomethanes. In this work, an electrolytic water pre-treatment was studied and applied to the water from a fountainhead. The action against microorganisms was evaluated using cast-iron and aluminum electrodes. Assays were made in laboratory using the electrolytic treatment. After 5 min of electrolysis the heterotrophic bacteria count was below 500 cfu/mL and complete elimination of total and fecal coliforms was observed. Using electrolytic treatment as a pretreatment of conventional tap water treatment is proposed.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Electrochemical processes in industrial effluents have been studied as a means to obtain higher efficiency in wastewater treatment. Heterogeneous photocatalysis appears as a low-cost alternative through the use of lower wattage lamps and thermal TiO2 films. Photocatalysis became a clean process for water treatment due to hydroxyl radicals generated on semiconductor surface. Such radicals are able to degrade several organic compounds. This study used different electrodes and analytical methods for degradation of phenol molecules to reduce treatment costs, improve efficiency, and identify compounds formed during the decomposition of phenolic molecules. Thermal growth of TiO2 film was observed on the titanium electrode in rutile form. Application of an electrical potential on the Ti/TiO2 working electrode increases efficiency in reducing concentration of phenol after photocatalytic treatment. Still, high energy radiation (UVC) showed best degradation rates in photolytic process. Different compounds formed during the degradation of phenol were also identified in the UVC-PE treatment.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Macroalgal communities and environmental variables were analyzed seasonally along a polluted tropical stream in São Paulo State, Brazil, We aimed to improve the knowledge of tropical macroalgal communities, to study the longitudinal and seasonal dynamics of these communities in influenced environments, to evaluate the relationship of algal frequency and abundance with selected environmental variables, and to look for potential macroalgal species indicators. The seasonal abundance pattern was similar to natural or low influenced systems and was mainly determined by rainfall regime. However, community composition was closely related to some chemical water pollution indicators, such as phosphorus and nitrogen compounds. Some species are suggested as potential indicators of organic pollution (e.g. Oscillatoria ornata, Stigeoclonium helveticum and Schizomeris leibleinii), but more detailed studies have to be developed to determine the tolerance limits of these species. on the basis of our results and literature data, the use of occurrence of Oscillatoriales in relation to other orders of Cyanoprokaryota is suggested to be a good indicator of organic pollution in tropical lotic ecosystems.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

We compared the fish assemblage structure from streams with different intensities of physical habitat degradation and chemical water pollution by domestic sewage in southeastern Brazil. Eight streams (R1-R8) showing less disturbed or more disturbed conditions of chemical water quality and of physical habitat quality were selected. Cumulative abundance and biomass, combined in ABC plots, revealed (i) biomass curves above the abundance curves, represented by the streams R1-R2 (water and habitat less disturbed) and R5-R6 (water more disturbed and habitat less disturbed), and (ii) biomass curves below the abundance curves, represented by the streams R3-R4 (water less disturbed and habitat more disturbed) and R7-R8 (water and habitat more disturbed). The quantitative structure of the ichthyofauna showed significant correspondence with physical habitat condition but not with chemical water quality. The most significant species to cause the dissimilarity between less disturbed and more disturbed physical habitats was the exotic Poecilia reticulata. Such results indicate that in the focused region-with little influence of industrial pollution, noncritical domestic sewage discharge, and soil predominantly used for pasture-streams with high physical habitat integrity possess a differently structured ichthyofauna than streams with relatively low physical habitat integrity, reinforcing the importance of the physical habitat quality and riparian conservation along these water courses, warranting the conservation of these systems. Indeed, our results also reinforce the importance of including biotic descriptors, particularly of the ichthyo-fauna, in water-monitoring programs designed to reveal signs of human interference.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

80.00% 80.00%

Publicador:

Resumo:

No Córrego do Sapateiro, situado no Parque Municipal do Ibirapuera, na cidade de São Paulo, SP, Brasil, amostras de água (50 mL) na profundidade de 10 centímetros foram coletadas em locais antes (local 1) e depois (local 2) da estação de tratamento de flotação, durante os meses da estação chuvosa e quente (janeiro, fevereiro e março) e da estação seca e fria (junho, julho e agosto) de 2008. Além disso, a temperatura, oxigênio dissolvido, condutividade e pH da água foram medidos com um equipamento Horiba U10. Coliformes totais e fecais foram analisados com o kit Aquatest®. A partir de cada amostra de água, alíquotas de 1 mL foram inoculadas em meio batata-dextrose-ágar, totalizando 10 placas de Petri para cada local de coleta. Após incubação por 10 dias a 22 ºC, as colônias fúngicas foram quantificadas, purificadas e identificadas. Os parâmetros abióticos da água não foram limitantes para a presença de geofungos, sendo influenciados pelo tratamento de flotação. Nos dois locais o número de coliformes totais e fecais foi predominantemente superior a 8 NMP dL-1 durante o período estudado. Vinte e sete táxons de fungos foram obtidos, distribuídos em 136 ocorrências. de acordo com o índice de similaridade de Sörensen, a micota dos dois locais coletados foram consideravelmente diferentes, apesar da semelhança entre o número de táxons e ocorrências. Os resultados indicam que o tratamento da água do Córrego do Sapateiro pelo sistema de flotação possivelmente causa modificações na composição taxonômica e na quantidade de UFC de fungos, ao contrário do que ocorreu com os coliformes totais e fecais, cujos resultados apresentaram-se menos conclusivos.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The work reported here involved the characterization of sludges produced at water treatment plants in Jaboticabal-SP using FeCl3 as flocculant, and in Taquaritinga-SP and Manaus-AM using Al2(SO4)3 as flocculant. An evaluation was also made of the interaction of organic matter extracted from the sludges with different metal species. The results indicated that all the sludges produced at water treatment plants have an important agricultural potential and that their use depends on the characteristics of the raw water and the type of flocculant employed in conventional treatment. The humic substances extracted from the sludges showed different affinities for metal species, favoring eventual exchanges between potentially toxic metals and macro- and micronutrients. An alternative for the use of sludge in agriculture is to pretreat it to remove potentially toxic metals and enrich it with micro- and macronutrients that can be released to the plant.