996 resultados para Without Buffer Gas


Relevância:

20.00% 20.00%

Publicador:

Resumo:

INTRODUCTION: Paracoccidioidomycosis (PCM) is the most important systemic mycosis in South America. Central nervous system involvement is potentially fatal and can occur in 12.5% of cases. This paper aims to contribute to the literature describing eight cases of neuroparacoccidioidomycosis (NPMC) and compare their characteristics with patients without neurological involvement, to identify unique characteristics of NPCM. METHODS: A cohort of 213 PCM cases was evaluated at the Infectious Diseases Clinic of the University Hospital, Federal University of Minas Gerais, Brazil, from October 1976 to August 2008. Epidemiological, clinical, laboratory, therapeutic and follow-up data were registered. RESULTS: Eight patients presented NPCM. The observed NPCM prevalence was 3.8%. One patient presented the subacute form of PCM and the other seven presented the chronic form of the disease. The parenchymatous form of NPCM occurred in all patients. 60% of the patients who proceeded from the north/ northeast region of Minas Gerais State developed NPCM. The neurological involvement of a mother and her son was observed. NPCM patients exhibited demographical and clinical profiles similar to what is described in the literature. When NPCM cases were compared to PCM patients, there were differences in relation to origin and positive PCM family history. CONCLUSIONS: The results corroborate the clinical view that the neurological findings are extremely important in the evaluation of PCM patients. Despite the limitations of this study, the differences in relation to patient's origins and family history point to the need of further studies to determine the susceptibility factors involved in the neurological compromise.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

25th International Cryogenic Engineering Conference and the International Cryogenic Materials Conference in 2014, ICEC 25–ICMC 2014

Relevância:

20.00% 20.00%

Publicador:

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Introduction Cryptococcosis is an opportunistic mycosis, especially in patients that are human immunodeficiency virus (HIV)-positive, and frequently involves the central nervous system. Methods We assessed the potential of ventriculoperitoneal shunting (VPS) in preventing mortality due to uncontrollable intracranial hypertension (ICH) in 15 patients with acquired immunodeficiency syndrome (AIDS)-related cryptococcal meningitis. Results After 2 weeks of antifungal therapy consisting of amphotericin B deoxycholate with or without fluconazole, patients with persistent ICH underwent VPS, despite having persistent Cryptococcus neoformans infection. In 12 patients, the uncontrollable ICH was resolved by VPS. Conclusions Patients with cryptococcal meningoencephalitis who have ICH must be considered for VPS even with positive cerebrospinal fluid cultures.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equity research report

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The present work is divided in two parts: Part 1 is focused on the analysis and treatment of a 19th century portrait of Domingos Affonso, which belongs to the Ecomuseu Municipal do Seixal; and Part 2, which is entitled “The Microclimate Frame Project” is focused on the study of Artsorb® and on the planning of a microclimate frame for the painting. In Part 1, a study of the painting’s materials was performed using complementary analytical techniques and the painting’s condition was carefully evaluated. The painting exhibited signs of mould growth, and a more detailed investigation was made of this topic to understand if the fungal community was active and if it represented a real danger to the painting. A treatment was proposed, appropriate to the painting’s condition. A description of the treatment carried out, comprising the treatment options, is also present in this section. Within the study of the microclimate frame, in Part 2, the study of the potential corrosiveness of Artsorb® was a central subject. Artsorb® sheets are one of the most widely used materials for buffering relative humidity fluctuations in microclimate frames and its reported excellent performance is enhanced by its availability in lightweight sheets that can be easily placed inside microclimate frames. However, concerns have arisen regarding the presence of the corrosive salt lithium chloride in the composition of this buffer. Consequently, the present work also aimed to understand the potential risks of using Artsorb® and the possibility of avoiding exposure of lithium chloride to the artworks through the use of Tyvek®. Results from the preliminary tests seem to indicate that Artsorb® releases lithium chloride into air. This study also showed that a Tyvek® cover over Artsorb® reduces but does not eliminate evidence of chlorine contamination, and it significantly reduces the effectiveness of the buffering material. Considering that Artsorb® appears to be unsuitable due to the release of the corrosive salt, that Tyvek® was not efficient as a barrier for lithium chloride or as a permeable material to enable the proper functioning of Artsorb®, the buffering material proposed for the use in the microclimate frames is silica gel without indicator. Based on the choice of buffering material, as a result of this study, a microclimate frame is proposed.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: The objective was to describe the results of the injection of immotile spermatozoa with flexible tails when only immotile spermatozoa are present in the semen sample. METHODS: A retrospective study was conducted to analyze the procedure results for 10 couples who participated in our intracytoplasmic sperm injection program. The sperm tail was considered flexible when it moved up and down independently of the head movement, and it was considered inflexible when the movement occurred together (tail plus head). The fertilization and pregnancy rate were analyzed. RESULTS: The normal fertilization rate (presence of 2 pronuclei) was 30.3% (40/132), and the abnormal fertilization rate (presence of less than or more than 2 pronuclei) was 6.81% (9/132). A total of 52 embryos were obtained with 9 transfer procedures performed (pregnancy rate: 11.12%). CONCLUSIONS: The sperm tail flexibility test (STFT) is an easy and cost-effective way for selecting viable immotile spermatozoa and can be used as an alternative method for determining the viability of spermatozoa. This test seems to be a simple and risk-free method when compared to the swelling test.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Equity research report

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The work presented in this thesis aims at developing a new separation process based on the application of supported magnetic ionic liquid membranes, SMILMs, using magnetic ionic liquids, MILs. MILs have attracted growing interest due to their ability to change their physicochemical characteristics when exposed to variable magnetic field conditions. The magnetic responsive behavior of MILs is thus expected to contribute for the development of more efficient separation processes, such as supported liquid membranes, where MILs may be used as a selective carrier. Driven by the MILs behavior, these membranes are expected to switch reversibly their permeability and selectivity by in situ and non-invasive adjustment of the conditions (e.g. intensity, direction vector and uniformity) of an external applied magnetic field. The development of these magnetic responsive membrane processes were anticipated by studies, performed along the first stage of this PhD work, aiming at getting a deep knowledge on the influence of magnetic field on MILs properties. The influence of the magnetic field on the molecular dynamics and structural rearrangement of MILs ionic network was assessed through a 1H-NMR technique. Through the 1H-NMR relaxometry analysis it was possible to estimate the self-diffusion profiles of two different model MILs, [Aliquat][FeCl4] and [P66614][FeCl4]. A comparative analysis was established between the behavior of magnetic and non-magnetic ionic liquids, MILs and ILs, to facilitate the perception of the magnetic field impact on MILs properties. In contrast to ILs, MILs show a specific relaxation mechanism, characterized by the magnetic dependence of their self-diffusion coefficients. MILs self-diffusion coefficients increased in the presence of magnetic field whereas ILs self-diffusion was not affected. In order to understand the reasons underlying the magnetic dependence of MILs self-diffusion, studies were performed to investigate the influence of the magnetic field on MILs’ viscosity. It was observed that the MIL´s viscosity decreases with the increase of the magnetic field, explaining the increase of MILs self-diffusion according to the modified Stokes- Einstein equation. Different gas and liquid transport studies were therefore performed aiming to determine the influence of the magnetic behavior of MILs on solute transport through SMILMs. Gas permeation studies were performed using pure CO2 andN2 gas streams and air, using a series of phosphonium cation based MILs, containing different paramagnetic anions. Transport studies were conducted in the presence and absence of magnetic field at a maximum intensity of 1.5T. The results revealed that gas permeability increased in the presence of the magnetic field, however, without affecting the membrane selectivity. The increase of gas permeability through SMILMs was related to the decrease of the MILs viscosity under magnetic field conditions.(...)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper presents the assessment of the out-of-plane response due to seismic loading of a masonry structure without rigid diaphragm. This structure corresponds to real scale brick masonry specimen with a main façade connected to two return walls. Two modelling approaches were defined for this evaluation. The first one consisted on macro modelling, whereas the second one on simplified micro modelling. As a first step of this study, static nonlinear analyses were conducted to the macro model aiming at evaluating the out-of-plane response and failure mechanism of the masonry structure. A sensibility analyses was performed in order to assess the mesh size and material model dependency. In addition, the macro models were subjected to dynamic nonlinear analyses with time integration in order to assess the collapse mechanism. Finally, these analyses were also applied to a simplified micro model of the masonry structure. Furthermore, these results were compared to experimental response from shaking table tests. It was observed that these numerical techniques simulate correctly the in-plane behaviour of masonry structures. However, the

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tese de Doutoramento em Ciências - Especialidade em Biologia

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Purpose: To evaluate how soft lens power affects rigid gas-permeable (RGP) lens power and visual acuity (VA) in piggyback fittings for keratoconus. Methods: Sixteen keratoconus subjects (30 eyes) were included in the study. Piggyback contact lens fittings combining Senofilcon-A soft lenses of −6.00, −3.00, +3.00 and +6.00 D with Rose K2 RGP contact lenses were performed. Corneal topography was taken on the naked eye and over each soft contact lens before fitting RGP lenses. Mean central keratometry, over-refraction, RGP back optic zone radius (BOZR) and estimated final power as well as VA were recorded and analyzed. Results: In comparison to the naked eye, the mean central keratometry flattened with both negative lens powers (p < 0.05 in all cases), did not change with the +3.00 soft lens power (p = 1.0); and steepened with the +6.00 soft lens power (p = 0.02). Rigid gas-permeable over-refraction did not change significantly between different soft lens powers (all p > 0.05). RGP’s BOZR decreased significantly with both positive in comparison with both negative soft lens powers (all p < 0.001), but no significant differences were found among negative- or positive-powers separately (both p > 0.05). Estimated RGP’s final power increased significantly with positive in comparison with negative lens powers (all p < 0.001), but no significant differences were found among negative or positive lens powers separately (both p > 0.05). Visual acuity did not change significantly between the different soft lens powers assessed (all p > 0.05). Conclusion: The use of negative-powered soft lenses in piggyback fitting reduces RGP lens power without impacting VA in keratoconus subjects.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To evaluate neophyte contact lens wearers’ fitting to rigid gas permeable (RGP) contact lenses in terms of wearing time, tear volume, stability, corneal staining, and subjective ratings, over a 1-month period of time. Methods: Twenty-two young healthy subjects were enrolled for wearing RGP on a daily wear basis. The participants included in this study never wore contact lenses and showed a value under 10 in McMonnies Questionnaire. Contact Lens Dry Eye Questionnaire, Visual Analog Scales, Schirmer test, tear film break-up time (BUT), and corneal staining grading were performed. Follow-up visits were scheduled at 1, 7, 15, and 28 days. Results: Six subjects dropped out due to discomfort from the study before 1 month (27% of discontinuation rate). Successful RGP wearers (16 participants) achieved high levels of subjective vision and reported comfort scores of approximately 9 of 10 between 10 and 15 days. They reported wearing their lenses for an average of 10.1262.43 hr after 1 month of wear. Conversely, unsuccessful wearers discontinued wearing the lenses after the first 10 to 15 days, showing comfort scores and wearing time significantly lower compared with the first day of wear. Schirmer test showed a signifi- cant increase at 10 days (P,0.001), and the BUT trends decreased after the first week of wear in unsuccessful group. Conclusions: Symptomatology related with dryness and discomfort, detected during the first 10 days of the adaptation, may help the clinician to predict those participants who will potentially fail to adapt to RGP lens wear.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Dissertação de mestrado em Engenharia Industrial (área de especialização em Qualidade, Segurança e Manutenção)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objetivo Avaliar a equivalência semântica e a consistência interna da Game Addiction Scale (GAS): versão em português. Métodos O procedimento constituiu-se das seguintes etapas: a) revisão da literatura; b) tradução do instrumento original; c) retrotradução; d) revisão técnica e avaliação da compreensão verbal, realizada por profissionais da área da saúde; e) avaliação da compreensão verbal do instrumento, por uma amostra de estudantes; f) análise da consistência interna (alfa de Cronbach). Os participantes, com exceção dos especialistas, foram selecionados por conveniência. A participação dos sujeitos foi diferente em cada fase: tradutores (n = 2), retrotradução (n = 1), revisão técnica (n = 2), especialistas (n = 12), pré-teste com estudantes universitários (n = 40) e mensuração com estudantes universitários (n = 100). Resultados Poucas alterações semânticas de expressões e termos foram realizadas para adaptar-se à cultura-alvo. O nível de compreensão verbal dos participantes (especialistas e estudantes) foi superior a 90% e a análise do alfa de Cronbach correspondeu a 0,92 para todo o instrumento. Conclusão A Escala de Dependência de Jogos Eletrônicos (ESDEJE) foi submetida a tradução e adaptação para o idioma português (do Brasil), apresentando consistência interna adequada. Ademais, sugere-se a realização do processo de validação referente à equivalência de mensuração e reprodutibilidade do instrumento.