943 resultados para Vertical Plate
Resumo:
In this work, we describe an experimental setup in which an electric current is used to determine the angular velocity attained by a plate rotating around a shaft in response to a torque applied for a given period. Based on this information, we show how the moment of inertia of a plate can be determined using a procedure that differs considerably from the ones most commonly used, which generally involve time measurements. Some experimental results are also presented which allow one to determine parameters such as the exponents and constant of the conventional equation of a plate's moment of inertia.
Resumo:
The Wii Balance Board (WBB) began to be investigated as a low-cost alternative for assessing static balance in vertical posture. However, studies employed methodological procedures that did not eliminate result variability between the tests and equipment used. Objective: Determine the validity and reproducibility of the WBB as an instrument for assessing static balance in the vertical position, using simultaneous data analysis and superimposed equipment. Methods: This is an accuracy study of 29 healthy young individuals of both sexes aged 18 to 30 years. Subjects were assessed 24h apart (test-retest), using unipodal and bipodal support tests, with eyes closed and open. To that end the WBB was placed on top of a force platform (FP) and data (postural sway) were collected simultaneously on both devices. Validity and reproducibility were analyzed using the interclass correlation coefficient (ICC). Finally, Bland-Altman analysis was applied to assess agreement. Results: The sample was composed of 23 women and 6 men, with mean age of 24.2±6.3 years, 60.7±6.3 kg and 1.64±4.2 m. The validity of the WBB compared to the FP was excellent for all 4 tasks proposed (ICC = 0.93 0.98). The reproducibility analyzed by test-retest was excellent for the bipodal support tasks (ICC = 0.93-0.98) and only moderate for the unipodal support tests (ICC = 0.46 0.70). Graphic analysis exhibited good agreement between the devices, since most of the measures were within the limits of agreement. Conclusion: this study proved the validity and reproducibility of the Wii Balance Board as an instrument for assessing static balance in vertical posture, using simultaneous analysis with superimposed equipment. Thus, the WBB has been increasingly used by physical therapists and other health professionals in their clinical practice, as both a rehabilitation and assessment tool
Resumo:
The objective of this paper is to show an alternative representation in time domain of a non-transposed three-phase transmission line decomposed in its exact modes by using two transformation matrices. The first matrix is Clarke's matrix that is real, frequency independent, easily represented in computational transient programs (EMTP) and separates the line into quasi-modes a, b and zero. After that, Quasi-modes a and zero are decomposed into their exact modes by using a modal transformation matrix whose elements can be synthesized in time domain through standard curve-fitting techniques. The main advantage of this alternative representation is to reduce the processing time because a frequency dependent modal transformation matrix of a three-phase line has nine elements to be represented in time domain while a modal transformation matrix of a two-phase line has only four elements. This paper shows modal decomposition process and eigenvectors of a non-transposed three-phase line with a vertical symmetry plane whose nominal voltage is 440 kV and line length is 500 km.
Resumo:
The study of algorithms for active vibration control in smart structures is an area of interest, mainly due to the demand for better performance of mechanical systems, such as aircraft and aerospace structures. Smart structures, formed using actuators and sensors, can improve the dynamic performance with the application of several kinds of controllers. This article describes the application of a technique based on linear matrix inequalities (LMI) to design an active control system. The positioning of the actuators, the design of a robust state feedback controller and the design of an observer are all achieved using LMI. The following are considered in the controller design: limited actuator input, bounded output (energy) and robustness to parametric uncertainties. Active vibration control of a flat plate is chosen as an application example. The model is identified using experimental data by an eigensystem realization algorithm (ERA) and the placement of the two piezoelectric actuators and single sensor is determined using a finite element model (FEM) and an optimization procedure. A robust controller for active damping is designed using an LMI framework, and a reduced model with observation and control spillover effects is implemented using a computer. The simulation results demonstrate the efficacy of the approach, and show that the control system increases the damping in some of the modes.
Resumo:
This paper presents an experimental technique for structural health monitoring (SHM) based on Lamb waves approach in an aluminum plate using piezoelectric material as actuators and sensors. Lamb waves are a form of elastic perturbation that remains guided between two parallel free surfaces, such as the upper and lower surfaces of a plate, beam or shelf. Lamb waves are formed when the actuator excites the surface of the structure with a pulse after receiving a signal. Two PZTs were placed in the plate surface and one of them was used to send a predefined wave through the structure. Thus, the other PZT (adjacent) becomes the sensor. Using this methodology, this paper presents one case of damage detection considering the aluminum plate in the free-free-free-free boundary condition. The damage was simulated by adding additional mass on the plate. It is proposed two damage detection indexes obtained from the experimental signal, involving the Fast Fourier Transform (FFT) and the power spectral density (PSD) that were computed using the output signal. The results show the viability of the presented methodology to damage detection in smart structures
Resumo:
In systems that combine the outputs of classification methods (combination systems), such as ensembles and multi-agent systems, one of the main constraints is that the base components (classifiers or agents) should be diverse among themselves. In other words, there is clearly no accuracy gain in a system that is composed of a set of identical base components. One way of increasing diversity is through the use of feature selection or data distribution methods in combination systems. In this work, an investigation of the impact of using data distribution methods among the components of combination systems will be performed. In this investigation, different methods of data distribution will be used and an analysis of the combination systems, using several different configurations, will be performed. As a result of this analysis, it is aimed to detect which combination systems are more suitable to use feature distribution among the components
Resumo:
A presença marcante de uma prosa-poética na produção ficcional de Clarice Lispector possibilitou-nos exemplificar algumas noções centrais (tempo vertical e instante poético) na rica e sugestiva reflexão de Gaston Bachelard acerca do universo poético
Resumo:
Objective: To compare the efficiency of an Aeroneb Pro vibrating plate and an Atomisor MegaHertz ultrasonic nebulizer for providing ceftazidime distal lung deposition.Design: In vitro experiments. One gram of cetazidime was nebulized in respiratory circuits and mass median aerodynamic diameter of particles generated by ultrasonic and vibrating plate nebulizers was compared using a laser velocimeter. In vivo experiments. Lung tissue concentrations and extrapulmonary depositions were measured in ten anesthetized ventilated piglets with healthy lungs that received 1 g of ceftazidime by nebulization with either an ultrasonic (n = 5), or a vibrating plate (n = 5) nebulizer.Setting: A two-bed Experimental Intensive Care Unit of a University School of Medicine.Intervention: Following sacrifice, 5 subpleural specimens were sampled in dependent and nondependent lung regions for measuring ceftazidime lung tissue concentrations by high-performance liquid chromatography.Measurements and results: Mass median aerodynamic diameters generated by both nebulizers were similar with more than 95% of the particles between 0.5 and 5 mu m. Lung tissue concentrations were 553 +/- 123 [95% confidence interval: 514-638] mu g g(-1) using ultrasonic nebulizer, and 452 +/- 172 [95% confidence interval: 376-528] mu g g(-1) using vibrating plate nebulizers (NS). Extrapulmonary depositions were, respectively, of 38 +/- 5% (ultrasonic) and 34 +/- 4% (vibrating plate) (NS).Conclusions: Vibrating plate nebulizer is comparable to ultrasonic nebulizers for ceftazidime nebulization. It may represent a new attractive technology for inhaled antibiotic therapy.
Resumo:
The purpose of this study was to evaluate through radiographic and microscopic analysis the efficiency of the filling techniques by vertical hidraulic compression after the root canal mechanical instrumentation in vitro as well to evaluate the marginal apical leakage through macroscopic and microscopic analysis. Thirty human mandibular molars were used , they were divided on three groups, these were subdivided on six subgroups with five specimens each, come down to 106 root canals filled. Initially, the teeth were instrumented with Profile system series 29 and filled with two ways: single accessory cone or single cone associated with gutta-percha secundary cone, with Fill Canal sealer or Sealer 26. Completed the filling, the teeth were coated with araldit and finger -nail polish except for the apical 2 mm and dried for 3 hours, thep radiographs were taken of the teeth in orto and disto-radiai directions. Next, the coronal seal was carried out with composite resin photopolymerized and with their process of making impermeable. Teeth of positive controls were used without araldit and finger-nail polish whereas the negative controls were used with total coat of araldit and finger-nail polish. The specimens were placed in 2% Methylene Blue dye for 24 hours and thermocycled for 7 days. Afterwards, sections were made of each tooth at mesial and distal roat, after this the teeth were radiographed at buccolíngual direction for a macroscopic analysis and at buccolingual and mesiodistal directions for assessment of the marginal apical leakage. Cross sections were made 3 mm to 3mm since the tooth apice. The sections obtained for each group were observed with a stereomicroscope to evaluate the quality of the root canal filling and the marginal apical leakage. The results showed that: In the four techniques the marginal dye leakage was present in the apical third; in all groups the quality of the root canal filling in the radiography was better at mesial root canal and the single cone technique showed inefficient when only a single distal root canal was present. In the radiographic evaluation the best quality of the root canal filling was observed in the 1A group (single accessory cone + FiIl Canal), as in the mesial root as in the distal root wich Shcwed twe root canals: when the distaI root had only one canal. the best result was showed by 28 group (single accessory cone associated with secundary cone + Fill Canal) In the macroscopic analysis of longitudinal !eaKage (outside surface). less leakage was showed as In the mesial root as in the distal root in the negative control group (3) followed 2A group (single accessory cone + Sealer 26). When the microscopic analysis of tranversal leakage of both roots (inside surface) was carried out. the groups that showed less dye leakage were the negative control (38) followed the 28 group (single acessory cone associated with secundary cone + Sealer 26). The homogeneity o filling was best noted in the 1 A group (.single accessoty cone + Fill Canal). The groups that showed less dye penetration in the tranversal leakage (total area) were negative control (3B) and 2B
Resumo:
The Araripe Basin is located over Precambrian terrains of the Borborema Province, being part of Northeast Brazil inner basins. Its origin is related to the fragmentation of the Gondwana supercontinent and consequently opening of South Atlantic during early Cretaceous. The basin has a sedimentary infill encompassing four distinct evolution stages, comprising Paleozoic syneclisis, pre-rift, rift and post-rift. The target of this study comprises the post-rift section of the basin focusing deformational styles which affect evaporates from Ipubi Member of the Santana Formation, which is composed by gypsum and anidrite layers interbedded with shales. These units occur widespread across the basin. In the central part of the basin, near Nova Olinda-Santana do Cariri, evaporites are affected by an essentialy brittle deformation tipified by fibrous gypsum filled fractures, cutting massive layers of gypsum and anidrite. Veins with variable orientations and dips are observed in the region distributed over three main populations: i) a dominant NWSE with shallow to moderate NE dipping population, consisting of gypsum filled veins in which fibers are normal to vein walls; i) NE-SW veins with moderate SE dips containing subhorizontal growth fibers; and iii) N-S veins with shallow E-W dips with fibers oblique to vein walls. In the west portion of the basin, near Trindade-Ipubi-Araripina towns, evaporate layers are dominantly constituted by gypsum/anidrite finely stratified, showing a minor density of veins. These layers are affected by a unique style of deformation, more ductile, typified by gentle to open horizontal normal folding with several tens of meters length and with double plunging NW-SE or NE-SW hinges, configuring domic features. In detail, gypsum/anidrite laminae are affected by metre to decimeter scale close to tight folding, usually kinked, with broken hinges, locally turning into box folds. Veins show NE-SW main directions with shallow NE dips, growth fibers are parallel to vein walls, constituting slickenfibers. This region is marked by faults that affect Araripina Formation with NW-SE, NE-SW and E-W directions. The main structural styles and general orientations of structures which affected the post-rift section of Araripe Basin yielded important kinematic information analysis which led us to infer a E-W to NE-SW extension direction to the northeastern part of the Basin, whereas in the southeastern part, extension occurred in N-S direction. Thus, it was possible to determine a regional kinematic setting, through this analysis, characterizing a NE-SW to ENE-WSW system for the post-rift section, which is compatible with the tension settings for the Sout American Plate since Albian. Local variations at the fluid pressure linked (or not) to sedimentary overload variation define local tension settings. This way, at the northeastern portion of the basin, the post-rift deformation was governed by a setting which σ 1 is sub-horizontal trending NE-SW and, σ 3 is sub-vertical, emphasizing a reverse fault situation. At the southwestern portion however there was characterized a strike slip fault setting, featuring σ 1 trending ENEWSW and σ3 trending NNW-SSE
Resumo:
Este estudo avalia os fatores maternos e fetais envolvidos na transmissão vertical do HIV-1 em 47 pares de mãe e filho. As variáveis comportamentais, demográficas e obstétricas foram obtidas mediante entrevista; os dados referentes ao parto e ao recém-nascido, dos prontuários das maternidades. Durante o terceiro trimestre de gestação foi realizada a contagem da carga viral materna e dos linfócitos T CD4+. A média de idade foi de 25 anos e 23,4% das gestantes eram primigestas, e o fator comportamental mais prevalente foi não usar preservativos. Dentre as gestantes, 48,9% tinham células CD4+ superior a 500 células/mm³ e 93,6% se enquadravam na categoria clínica A; 95,7% submeteram-se à profilaxia com zidovudina durante a gestação ou no parto, a qual foi ministrada a todos os recém-nascidos; 50,0% delas foram submetidas à cesárea eletiva. Apesar de expostas a vários fatores de risco e protetores, nenhuma criança tornou-se infectada. A transmissão vertical resulta de um desequilíbrio entre os fatores, com predomínio dos de risco sobre os protetores.
Resumo:
Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)
Resumo:
This study aimed to develop a plate to treat fractures of the mandibular body in dogs and to validate the project using finite elements and biomechanical essays. Mandible prototypes were produced with 10 oblique ventrorostral fractures (favorable) and 10 oblique ventrocaudal fractures (unfavorable). Three groups were established for each fracture type. Osteosynthesis with a pure titanium plate of double-arch geometry and blocked monocortical screws offree angulanon were used. The mechanical resistance of the prototype with unfavorable fracture was lower than that of the fcworable fracture. In both fractures, the deflection increased and the relative stiffness decreased proportionally to the diminishing screw number The finite element analysis validated this plate study, since the maximum tension concentration observed on the plate was lower than the resistance limit tension admitted by the titanium. In conclusion, the double-arch geometry plate fixed with blocked monocortical screws has sufficient resistance to stabilize oblique,fractures, without compromising mandibular dental or neurovascular structures. J Vet Dent 24 (7); 212 - 221, 2010
Resumo:
Purpose: Three-dimensional finite element analysis was used to evaluate the effect of vertical and angular misfit in three-piece implant-supported screw-retained fixed prostheses on the biomechanical response in the peri-implant bone, implants, and prosthetic components. Materials and Methods: Four three-dimensional models were fabricated to represent a right posterior mandibular section with one implant in the region of the second premolar (2PM) and another in the region of the second molar (2M). The implants were splinted by a three-piece implant-supported metal-ceramic prosthesis and differed according to the type of misfit, as represented by four different models: Control = prosthesis with complete fit to the implants; UAM (unilateral angular misfit) = prosthesis presenting unilateral angular misfit of 100 pm in the mesial region of the 2M; UVM (unilateral vertical misfit) = prosthesis presenting unilateral vertical misfit of 100 pm in the mesial region of the 2M; and TVM (total vertical misfit) = prosthesis presenting total vertical misfit of 100 pm in the platform of the framework in the 2M. A vertical load of 400 N was distributed and applied on 12 centric points by the software Ansys, ie, a vertical load of 150 N was applied to each molar in the prosthesis and a vertical load of 100 N was applied at the 2PM. Results: The stress values and distribution in peri-implant bone tissue were similar for all groups. The models with misfit exhibited different distribution patterns and increased stress magnitude in comparison to the control. The highest stress values in group UAM were observed in the implant body and retention screw. The groups UVM and TVM exhibited high stress values in the platform of the framework and the implant hexagon, respectively. Conclusions: The three types of misfit influenced the magnitude and distribution of stresses. The influence of misfit on peri-implant bone tissue was modest. Each type of misfit increased the stress values in different regions of the system. INT J ORAL MAXILLOFAC IMPLANTS 2011;26:788-796
Resumo:
The aim of this study was to describe the treatment used in an elderly patient presenting with bruxism and dental erosion, with good gingival health and bone support, but with decreased occlusal vertical dimension (OVD). The oral rehabilitation of elderly patients presenting with bruxism in association with tooth erosion has been a great challenge for dentists. The loss of OVD, the presence of occlusal instability and the absence of an effective anterior guide due excessive dental wear, can damage stomatognathic system (SS) biology, the function and the aesthetics. In the first treatment stage, an overlay removable partial denture (ORPD) was fabricated for the immediate re-establishment of function and aesthetics. After a 2-month follow up, with the patient presenting no symptoms, a second rehabilitation stage was accomplished, with fixed and removable prostheses. Oral rehabilitation with an ORPD was able to re-establish the SS biology, but a correct diagnosis and treatment plan are essential for success. The ORPD is a non-invasive and reversible restoring modality for general dentists that allow the re-establishment of the patient's immediate aesthetics and function at low cost.