650 resultados para Tubos - Soldagem


Relevância:

10.00% 10.00%

Publicador:

Resumo:

Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pós-graduação em Ciência Odontólogica - FOA

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In contemporary industrial, welding processes are widely used, this is the most important process of joining metals used industrially. The welding can be used to build simple structures, like doors and gates for instance, in the same way can be used in situations of high responsibility, such as the nuclear industry and oil industry. Dissimilar welding is a case of welded joints, is characterized by the junction between different materials, for this case, stainless steel and carbon steel that are widely used in steam lines, power plants, nuclear reactors, petrochemical plants. Because their different mechanical and corrosive properties, the join, stainless steel with carbon steel, not only meets environmental requirements and also reduces cost. By using penetrating liquid tests, macrograph, hardness and tensile test was compared the possibility of replacing the current use of 309 rods as filler metal in dissimilar welding between carbon steel and stainless steel by add-on material carbon steel essentially, in this case E7018 coated electrode was used, but without the coating. After analysis of the results and for comparison, was proposed with some certainty that it is possible to replace the addition of materials, thus leading economy in this process widely used in the modern industry

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Pressure vessels are equipments that require a great care because of their high cost and human life risk in case of fail, and its fabrication methods are different for each manufacturer. Normally, pressure vessels and its parts are fabricated by welding, which may change local properties of metals. The head of a pressure vessel is a very important structural component and it is fabricated by welding and mechanical conformation. Because its excellent mechanical properties, de steel A-516 Grade 70 is often used in manufacturing of large pressure vessels that are subjected to high pressure and temperature, but was verified that its mechanical resistance is decreased when submitted to a tension relief heat treatment. By experience it was defined that before mechanical conformation of the head of a large pressure vessel, the steel should be submitted to a stress relief heat treatment in order to facilitate the mechanical conformation, but there is no quantitative analysis to prove this method and study its possible risks. In the present work the steel A-516 Grade 70 demonstrated a decrease of its mechanical resistance when submitted to a stress relief heat treatment, but keeping above the minimum limit defined in the literature. By other side its ductility was substantially increased, being possible to deduce that the stress relief heat treatment before mechanical conformation is a viable e recommended technique, but with reservations. With the data acquired during the fabrication e preparation of the specimen and the result of the tests, it was possible to elaborate a welding procedure that provides the same results obtained in this present work

Relevância:

10.00% 10.00%

Publicador:

Resumo:

O pescado e seus derivados têm uma grande importância na dieta, em todo o mundo. Sabe-se que peixes e frutos do mar fortalecem o sistema imunológico, contribuem para a redução dos níveis de colesterol, diminuem as chances de depressão, ajudam na formação dos músculos e protegem contra doenças cardiovasculares. Também, são ricos em vitaminas lipossolúveis A, D e E, além do ômega 3. Muitas vezes, esses produtos são consumidos crus ou com pouco preparo e com isso faz-se necessário medidas higiênico- sanitárias, pois podem ser contaminados com micro-organismos causadores de doenças. A análise microbiológica dos alimentos para se verificar a presença de micro-organismos prejudiciais é fundamental para se conhecer as condições de higiene nas quais estes alimentos foram preparados. Assim, 80 amostras de peixes e frutos do mar de peixarias e supermercados de Botucatu, SP, foram analisadas com o objetivo de verificar se esses alimentos estão dentro dos padrões estabelecidos pela legislação brasileira, através da RDC nº12, através da detecção da presença de Salmonella sp., Staphylococcus aureus e determinação do número mais provável de coliformes termotolerantes (CT), mesmo que este último não faça parte dos parâmetros para esse alimento, mas foi pesquisado para avaliação de suas condições higiênicas. Cada amostra (25 gramas) foi homogeneizada em 225ml de água peptonada e para a detecção de S. aureus, utilizou-se método spread Baird Parker, seguida de catalase, coagulase e kit Dry Spot. Para a detecção de Salmonella, utilizou-se caldo tetrationato (35ºC/24h) e Rapapport (42ºC/24h), semeados em ágar SS e XLD. As colônias foram testadas em TSI, ágar fenilalanina e testadas em poli soros somático e flagelar. Quanto aos CT, empregou-se a técnica de tubos múltiplos, inoculando diluições da amostra em caldo Lauril sulfato, na fase presuntiva e depois em caldo EC (45ºC) na fase confirmatória. De ...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Due to its high prevalence in general population, Angle Class II malocclusion has been widely studied by several authors, as well as the methods for its treatment. Among the possible treatment methods stands out the Herbst appliance. Reintroduced more than three decades ago in the orthodontics community, it became the most utilized appliance because it does not require patient compliance, and provides continued action through bilateral telescopic tubes. The objective of the present article was to demonstrate the early treatment of Class II Division 1 malocclusion with mandibular retrusion using Herbst appliance.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Nanotechnology, the science of minuscule, has developed products which are able t o manipulate atoms and molecules that could be applied in the sterilization process of dental instruments. Objetives: The objective of the present study was to evaluate the self-cleaning action of TiO2 and Ag nanoparticles coating on dental instruments by the photocataliys process under UV and visible light irradiation. Material and method: Microbiologic tests were done using dental cement spatulas coated with TiO2 and Ag nanoparticles (one or three layers), and contaminated with 10 mcrl of Pseudomonas aeruginosa and Enterococcus faecalis, respectively. After contamination, they were exposed to ultraviolet light and visible light for 120 minutes. Next, they were transferred to and stored in test tubes with BHI (Brain Heart Infusion) and incubated in 35 to 37 °C. Checking times for bacterial growth and for control and retrieval tests were done at: 24, 48, 72 and 96 hours. Result: The Pseudomonas aeruginosa was inactive after 120 minutes of ultraviolet light irradiation, thus confirming the heterogeneous photocatalytic activity of TiO2 and Ag. The Pseudomonas aeruginosa was not inactivated under visible light irradiation and the Enterococcus faecalis was not inactivated under UV and visible light irradiation of the dental cement spatulas coated with TiO2 and Ag nanoparticles in the readings to 96 hours, showing bacterial growth. Conclusion: There were no influence of one or three layers of TiO2 and Ag nanoparticles coating of the spatulas in the results. The heterogeneous photocatalysis activity of TiO2 and Ag under UV light irradiation was confirmed for Pseudomonas aeruginosa but not under visible light. Enterococcus faecalis did not confirmed the photocatalytics activity of TiO2 and Ag under UV light irradiation and visible lights irradiation.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The main objective of this work was to mount and test an experimental model to measure the hydraulic conductance of ex vivo dentin. Seventeen healthy third molars, with indication of extraction of healthy donors aged between 15 and 30 years were obtained by informed consent. After cleaning them, disinfecting them, including them in resin epoxy and cutting them, there were 17 samples of dentin, corresponding to a disk of resin with a coronal section of tooth showing the dentin exposed on both sides of it. Three machines to measure the hydraulic conductance of the dentin were assembled according to the description of the model of Pashley. Samples were installed in a Chamber of diffusion, connected by using silicone tubes to a graduated transfer pipette and a 20cm water column. Through the displacement of a bubble of water in the inside of the pipette, the hydraulic conductance of each sample was measured 3 times on the 14th, 21st, 28th and 35th day post extraction. The data were tabulated and analyzed statistically. There is no SS difference in the rate of flow of a measured sample in the three machines (p=0.5937). There is no SS difference in measurements of the hydraulic conductance of 13 samples of human dentin measured in days 14, 21, 28 and 35 postextraction (p=0.0704). It is possible to mount an experimental model to study the hydraulic conductance of dentin ex vivo, based on the model of Pashley. The model seems to be reliable, but more research is needed in order to validate its reliability.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Objective: The aim of this study was to evaluate the pH of calcium hydroxide (CalenTM) when associated or not with chlorhexidine 0.4%, and when associated with chlorhexidine with the addition of 20% or 10% of alphatocopherol (AchéTM), assessed in several periods of time. Methods: Fourty dentine tubes 20 mm, properly standardized, were made from bovine anterior teeth roots. Following, a perforation was achieved in the roots distal face at 7 mm from the cervical radicular line by using a #1/2 carbide bur. After complete root sealing is made, except in the perforation local, the radicular canals were filled with one of the following associations: Group I – Calen®; Group II – Calen™ with chlorehxidine at 0.4%; Group III – Calen™ with chlorhexidine at 0.4% with the addition of 20% (weight) of alhatocopherol compound and Group IV – Calen™ with chlorhexidine at 0.4% with the addition of 10% (weight) alphatocopherol. After cervical sealing is accomplished, the roots were immersed in water MiliQ and the pH, assessed in 24h, 7, 14, 21, 28 and 45 days. Results and Conclusion: In all periods tested, the pH of the calcium hydroxide (Calen™) was similar to the pH of the calcium hydroxide (Calen™) associated with chlorhexidine 0.4% and 10% alphatocopherol (p > 0.05). The association of 20% alphatocopherol obtained the pH lower than the association with 10% (p < 0.05). The pH of the association with chlorhexidine was similar to the pure calcium hydrocide (Calen™) after the 14th day (p > 0.05) only. Therefore, on the 45th day, this difference was significant again (p < 0.05).

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Sealer 26® cement contains bisphenol epoxy resin associated with calcium hydroxide, presenting smaller radiopacity than other endodontic cements. Aiming to improve this property, iodoform has been added in its composition. However, this addition's possible changes in physical and chemical properties still need to be studied. OBJECTIVE: To evaluate the apical sealing ability, solubility, and pH of Sealer 26® alone or with iodoform, at several proportions. MATERIAL AND METHODS: Three experimental mixtures of Sealer 26®, alone or with iodoform, were prepared and subjected to solubility test. Additionally, these combinations were inserted into polyethylene tubes and immersed in distilled water, and, their pH was evaluated after 24-h and 7-day periods. Subsequently, forty roots of extracted lower incisors subdivided into four groups of 10 specimens each, were retrograde filled with one of the previously described mixtures and gutta-percha points. The roots were immersed in Rhodamine B, under vacuum, for 72 hours. After this period, the specimens were longitudinally sectioned, root fragments photographed, these images scanned, and apical infiltration measured by Image tool software. The obtained data were subjected to statistical analysis, at a significance level of 5%. RESULTS: Marginal leakage and solubility tests did not show any difference among the experimental groups (p > 0.05). pH analysis was only statistically different at 24-h period and between Sealer 26® alone and 1.1g iodoform group (p < 0.05). CONCLUSION: The presence of iodoform in Sealer 26®, at the used proportions, did not alter the solubility, apical marginal leakage and pH properties of the original cement.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Conselho Nacional de Desenvolvimento Científico e Tecnológico (CNPq)

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aperfeiçoamento em equipamento para digestão de amostras por via úmida. É descrito um aperfeiçoamento em equipamento para digestão de amostras por via úmida que emprega tubos de digestão (20) fechados não encapsulados e aquecimento condutivo que possibilita a rápida decomposição de amostras botânicas, alimentícias, clínicas, ambientais e similares, promovendo um gradiente de temperatura em direção à parte superior do tubo de digestão, permitindo que a temperatura da fase gasosa seja inferior à da fase líquida, de forma que as digestões são realizadas à pressão pouco elevada e, consequentemente, os tubos de digestão utilizados podem ter paredes menos espessas, permitindo o rápido aquecimento e resfriamento das amostras, bem como baixo custo de operação e manutenção, simplicidade, alta frequência analítica,; redução do consumo de reagentes e diminuição da geração de resíduos, dito equipamento provido de um gabinete (10) que evita a contaminação da atmosfera do laboratório por vapores ácidos e a perda dos componentes voláteis da amostra durante o aquecimento