939 resultados para Thoracic surgery, video-assisted


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Analysis of minimally invasive surgical videos is a powerful tool to drive new solutions for achieving reproducible training programs, objective and transparent assessment systems and navigation tools to assist surgeons and improve patient safety. This paper presents how video analysis contributes to the development of new cognitive and motor training and assessment programs as well as new paradigms for image-guided surgery.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AIM: To define the financial and management conditions required to introduce a femtosecond laser system for cataract surgery in a clinic using a fuzzy logic approach. METHODS: In the simulation performed in the current study, the costs associated to the acquisition and use of a commercially available femtosecond laser platform for cataract surgery (VICTUS, TECHNOLAS Perfect Vision GmbH, Bausch & Lomb, Munich, Germany) during a period of 5y were considered. A sensitivity analysis was performed considering such costs and the countable amortization of the system during this 5y period. Furthermore, a fuzzy logic analysis was used to obtain an estimation of the money income associated to each femtosecond laser-assisted cataract surgery (G). RESULTS: According to the sensitivity analysis, the femtosecond laser system under evaluation can be profitable if 1400 cataract surgeries are performed per year and if each surgery can be invoiced more than $500. In contrast, the fuzzy logic analysis confirmed that the patient had to pay more per surgery, between $661.8 and $667.4 per surgery, without considering the cost of the intraocular lens (IOL). CONCLUSION: A profitability of femtosecond laser systems for cataract surgery can be obtained after a detailed financial analysis, especially in those centers with large volumes of patients. The cost of the surgery for patients should be adapted to the real flow of patients with the ability of paying a reasonable range of cost.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interacting with a computer system in the operating room (OR) can be a frustrating experience for a surgeon, who currently has to verbally delegate to an assistant every computer interaction task. This indirect mode of interaction is time consuming, error prone and can lead to poor usability of OR computer systems. This thesis describes the design and evaluation of a joystick-like device that allows direct surgeon control of the computer in the OR. The device was tested extensively in comparison to a mouse and delegated dictation with seven surgeons, eleven residents, and five graduate students. The device contains no electronic parts, is easy to use, is unobtrusive, has no physical connection to the computer and makes use of an existing tool in the OR. We performed a user study to determine its effectiveness in allowing a user to perform all the tasks they would be expected to perform on an OR computer system during a computer-assisted surgery. Dictation was found to be superior to the joystick in qualitative measures, but the joystick was preferred over dictation in user satisfaction responses. The mouse outperformed both joystick and dictation, but it is not a readily accepted modality in the OR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: This study has been undertaken to audit a single-center experience with laparoscopically-assisted resection rectopexy for full-thickness rectal prolapse. The clinical Outcomes and long-term results were evaluated. METHODS: The data were prospectively collected for the duration of the operation, time to passage of flatus postoperatively, hospital stay, morbidity, and mortality. For follow-up, patients received a questionnaire or were contacted. The data were divided into quartiles over the study period, and the differences in operating time and length of hospital stay were tested using the Kruskal-Wallis test. RESULTS: Between March 1992 and October 2003, a total of 117 patients underwent laparoscopic resection rectopexy for rectal prolapse. The median operating time during the first quartile (representing the early experience) was 180 minutes compared with 110 minutes for the fourth quartile (Kruskal-Wallis test for operating time = 35.523, 3 df, P < 0.0001). Overall morbidity was 9 percent (ten patients), with one death (< 1 percent). One patient had a ureteric injury requiring conversion. One minor anastomotic leak Occurred, necessitating laparoscopic evacuation of a pelvic abscess. Altogether, 77 patients were available for follow-up. The median follow-up was 62 months. Eighty percent of the patients reported alleviation of their symptoms after the operation. Sixty-nine percent of the constipated patients experienced an improvement in bowel frequency. No patient had new or worsening symptoms of constipation after Surgery. Two (2.5 percent) patients had full-thickness rectal prolapse recurrence. Mucosal prolapse recurred in 14 (18 percent) patients. Anastomotic dilation was performed for stricture in five (4 percent) patients. CONCLUSIONS: Laparoscopically-assisted resection rectopexy for rectal prolapse provides a favorable functional outcome and low recurrence rate. Shorter operating time is achieved with experience. The minimally invasive technique benefits should be considered when offering rectal prolapse patients a transabdominal approach for repair, and emphasis should now be on advanced training in the laparoscopic approach.

Relevância:

30.00% 30.00%

Publicador:

Relevância:

30.00% 30.00%

Publicador:

Resumo:

To study the visual and refractive outcomes after laser-assisted subepithelial keratectomy (LASEK) performed with a 213 nm solid-state laser for a broad range of refractive errors.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

FULL TEXT: Like many people one of my favourite pastimes over the holiday season is to watch the great movies that are offered on the television channels and new releases in the movie theatres or catching up on those DVDs that you have been wanting to watch all year. Recently we had the new ‘Star Wars’ movie, ‘The Force Awakens’, which is reckoned to become the highest grossing movie of all time, and the latest offering from James Bond, ‘Spectre’ (which included, for the car aficionados amongst you, the gorgeous new Aston Martin DB10). It is always amusing to see how vision correction or eye injury is dealt with by movie makers. Spy movies and science fiction movies have a freehand to design aliens with multiples eyes on stalks or retina scanning door locks or goggles that can see through walls. Eye surgery is usually shown in some kind of day case simplified laser treatment that gives instant results, apart from the great scene in the original ‘Terminator’ movie where Arnold Schwarzenegger's android character encounters an injury to one eye and then proceeds to remove the humanoid covering to this mechanical eye over a bathroom sink. I suppose it is much more difficult to try and include contact lenses in such movies. Although you may recall the film ‘Charlie's Angels’, which did have a scene where one of the Angels wore a contact lens that had a retinal image imprinted on it so she could by-pass a retinal scan door lock and an Eddy Murphy spy movie ‘I-Spy’, where he wore contact lenses that had electronic gadgetry that allowed whatever he was looking at to be beamed back to someone else, a kind of remote video camera device. Maybe we aren’t quite there in terms of devices available but these things are probably not the behest of science fiction anymore as the technology does exist to put these things together. The technology to incorporate electronics into contact lenses is being developed and I am sure we will be reporting on it in the near future. In the meantime we can continue to enjoy the unrealistic scenes of eye swapping as in the film ‘Minority Report’ (with Tom Cruise). Much more closely to home, than in a galaxy far far away, in this issue you can find articles on topics much nearer to the closer future. More and more optometrists in the UK are becoming registered for therapeutic work as independent prescribers and the number is likely to rise in the near future. These practitioners will be interested in the review paper by Michael Doughty, who is a member of the CLAE editorial panel (soon to be renamed the Jedi Council!), on prescribing drugs as part of the management of chronic meibomian gland dysfunction. Contact lenses play an active role in myopia control and orthokeratology has been used not only to help provide refractive correction but also in the retardation of myopia. In this issue there are three articles related to this topic. Firstly, an excellent paper looking at the link between higher spherical equivalent refractive errors and the association with slower axial elongation. Secondly, a paper that discusses the effectiveness and safety of overnight orthokeratology with high-permeability lens material. Finally, a paper that looks at the stabilisation of early adult-onset myopia. Whilst we are always eager for new and exciting developments in contact lenses and related instrumentation in this issue of CLAE there is a demonstration of a novel and practical use of a smartphone to assisted anterior segment imaging and suggestions of this may be used in telemedicine. It is not hard to imagine someone taking an image remotely and transmitting that back to a central diagnostic centre with the relevant expertise housed in one place where the information can be interpreted and instruction given back to the remote site. Back to ‘Star Wars’ and you will recall in the film ‘The Phantom Menace’ when Qui-Gon Jinn first meets Anakin Skywalker on Tatooine he takes a sample of his blood and sends a scan of it back to Obi-Wan Kenobi to send for analysis and they find that the boy has the highest midichlorian count ever seen. On behalf of the CLAE Editorial board (or Jedi Council) and the BCLA Council (the Senate of the Republic) we wish for you a great 2016 and ‘may the contact lens force be with you’. Or let me put that another way ‘the CLAE Editorial Board and BCLA Council, on behalf of, a great 2016, we wish for you!’

Relevância:

30.00% 30.00%

Publicador:

Resumo:

With the proliferation of multimedia data and ever-growing requests for multimedia applications, there is an increasing need for efficient and effective indexing, storage and retrieval of multimedia data, such as graphics, images, animation, video, audio and text. Due to the special characteristics of the multimedia data, the Multimedia Database management Systems (MMDBMSs) have emerged and attracted great research attention in recent years. Though much research effort has been devoted to this area, it is still far from maturity and there exist many open issues. In this dissertation, with the focus of addressing three of the essential challenges in developing the MMDBMS, namely, semantic gap, perception subjectivity and data organization, a systematic and integrated framework is proposed with video database and image database serving as the testbed. In particular, the framework addresses these challenges separately yet coherently from three main aspects of a MMDBMS: multimedia data representation, indexing and retrieval. In terms of multimedia data representation, the key to address the semantic gap issue is to intelligently and automatically model the mid-level representation and/or semi-semantic descriptors besides the extraction of the low-level media features. The data organization challenge is mainly addressed by the aspect of media indexing where various levels of indexing are required to support the diverse query requirements. In particular, the focus of this study is to facilitate the high-level video indexing by proposing a multimodal event mining framework associated with temporal knowledge discovery approaches. With respect to the perception subjectivity issue, advanced techniques are proposed to support users' interaction and to effectively model users' perception from the feedback at both the image-level and object-level.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Recently, blood oxygen level-dependent (BOLD) functional magnetic resonance imaging (fMRI) has become a routine clinical procedure for localization of language and motor brain regions and has been replacing more invasive preoperative procedures. However, the fMRI results from these tasks are not always reproducible even from the same patient. Evaluating the reproducibility of language and speech mapping is especially complicated due to the complex brain circuitry that may become activated during the functional task. Non-language areas such as sensory, attention, decision-making, and motor brain regions may also be activated in addition to the specific language regions during a traditional sentence-completion task. In this study, I test a new approach, which utilizes 4-minute video-based tasks, to map language and speech brain regions for patients undergoing brain surgery. Results from 35 subjects have shown that the video-based task activates Wernicke’s area, as well as Broca’s area in most subjects. The computed laterality indices, which indicate the dominant hemisphere from that functional task, have indicated left dominance from the video-based tasks. This study has shown that the video-based task may be an alternative method for localization of language and speech brain regions for patients who are unable to complete the sentence-completion task.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Interacting with a computer system in the operating room (OR) can be a frustrating experience for a surgeon, who currently has to verbally delegate to an assistant every computer interaction task. This indirect mode of interaction is time consuming, error prone and can lead to poor usability of OR computer systems. This thesis describes the design and evaluation of a joystick-like device that allows direct surgeon control of the computer in the OR. The device was tested extensively in comparison to a mouse and delegated dictation with seven surgeons, eleven residents, and five graduate students. The device contains no electronic parts, is easy to use, is unobtrusive, has no physical connection to the computer and makes use of an existing tool in the OR. We performed a user study to determine its effectiveness in allowing a user to perform all the tasks they would be expected to perform on an OR computer system during a computer-assisted surgery. Dictation was found to be superior to the joystick in qualitative measures, but the joystick was preferred over dictation in user satisfaction responses. The mouse outperformed both joystick and dictation, but it is not a readily accepted modality in the OR.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Small bowel obstruction (SBO) is a very common condition, in the vast majority of cases caused by post-operative adhesions. It often requires surgical treatment. Traditionally, this consisted of a laparotomy, but nowadays a laparoscopic approach is also possible. This study discusses 24 cases of SBO and compares them with literature data. Successful complete laparoscopic treatment was feasible in 9 patients, while conversion to laparoscopically-assisted surgery or laparotomy was required for the others.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

The Authors discuss on a laparoscopic-assisted approach for excision of a sessile villous adenomatous polyp of the cecum, unresectable by endoscopy. Because of the large implant of the polyp, endoscopic polypectomy was considered at high risk and a surgical laparoscopic procedure was scheduled for removal of the lesion. After right colon mobilization, an intraoperative endoscopy confirmed the location of th polyp in the posterior wall of the cecum, closed to the ileo-cecal valve. A small 10 cm laparotomy, through which the cecum was pulled out the abdominal cavity, was performed. Then, a minimal colotomy along the intestinal taenia was carried out to allow a safe and complete excision of the polyp. This laparoscopic approach differs from the other laparoscopic-assisted methods reported in the Literature since it provides at the same time the postoperative advantages associated with minimal access surgery and a safe oncological removal of the polyp with low risks of complications. .