994 resultados para Tests accuracy
Resumo:
We present dual-wavelength Digital Holographic Microscopy (DHM) measurements on a certified 8.9 nm high Chromium thin step sample and demonstrate sub-nanometer axial accuracy. We introduce a modified DHM Reference Calibrated Hologram (RCH) reconstruction algorithm taking into account amplitude contributions. By combining this with a temporal averaging procedure and a specific dual-wavelength DHM arrangement, it is shown that specimen topography can be measured with an accuracy, defined as the axial standard deviation, reduced to at least 0.9 nm. Indeed, it is reported that averaging each of the two wavefronts recorded with real-time dual-wavelength DHM can provide up to 30% spatial noise reduction for the given configuration, thanks to their non-correlated nature. ©2008 COPYRIGHT SPIE
The hematology laboratory in blood doping (bd): 2014 update on the athlete biological passport (APB)
Resumo:
Introduction: Blood doping (BD) is the use of Erythropoietic Stimulating Agents (ESAs) and/or transfusion to increase aerobic performance in athletes. Direct toxicologic techniques are insufficient to unmask sophisticated doping protocols. The Hematological module of the ABP (World Anti-Doping Agency), associates decision support technology and expert assessment to indirectly detect BD hematological effects. Methods: The ABP module is based on blood parameters, under strict pre-analytical and analytical rules for collection, storage and transport at 2-12°C, internal and external QC. Accuracy, reproducibility and interlaboratory harmonization fulfill forensic standard. Blood samples are collected in competition and out-ofcompetition. Primary parameters for longitudinal monitoring are: - hemoglobin (HGB); - reticulocyte percentage (RET); - OFF score, indicator of suppressed erythropoiesis, calculated as [HGB(g/L) * 60-√RET%]. Statistical calculation predicts individual expected limits by probabilistic inference. Secondary parameters are RBC, HCT, MCHC-MCH-MCV-RDW-IFR. ABP profiles flagged as atypical are review by experts in hematology, pharmacology, sports medicine or physiology, and classified as: - normal - suspect (to target) - likely due to BD - likely due to pathology. Results: Thousands of athletes worldwide are currently monitored. Since 2010, at least 35 athletes have been sanctioned and others are prosecuted on the sole basis of abnormal ABP, with a 240% increase of positivity to direct tests for ESA, thanks to improved targeting of suspicious athletes (WADA data). Specific doping scenarios have been identified by the Experts (Table and Figure). Figure. Typical HGB and RET profiles in two highly suspicious athletes. A. Sample 2: simultaneous increases in HGB and RET (likely ESA stimulation) in a male. B. Samples 3, 6 and 7: "OFF" picture, with high HGB and low RET in a female. Sample 10: normal HGB and increased RET (ESA or blood withdrawal). Conclusions: ABP is a powerful tool for indirect doping detection, based on the recognition of specific, unphysiological changes triggered by blood doping. The effect of factors of heterogeneity, such as sex and altitude, must also be considered. Schumacher YO, et al. Drug Test Anal 2012, 4:846-853. Sottas PE, et al. Clin Chem 2011, 57:969-976.
Resumo:
Sobriety checkpoints are not usually randomly located by traffic authorities. As such, information provided by non-random alcohol tests cannot be used to infer the characteristics of the general driving population. In this paper a case study is presented in which the prevalence of alcohol-impaired driving is estimated for the general population of drivers. A stratified probabilistic sample was designed to represent vehicles circulating in non-urban areas of Catalonia (Spain), a region characterized by its complex transportation network and dense traffic around the metropolis of Barcelona. Random breath alcohol concentration tests were performed during spring 2012 on 7,596 drivers. The estimated prevalence of alcohol-impaired drivers was 1.29%, which is roughly a third of the rate obtained in non-random tests. Higher rates were found on weekends (1.90% on Saturdays, 4.29% on Sundays) and especially at night. The rate is higher for men (1.45%) than for women (0.64%) and the percentage of positive outcomes shows an increasing pattern with age. In vehicles with two occupants, the proportion of alcohol-impaired drivers is estimated at 2.62%, but when the driver was alone the rate drops to 0.84%, which might reflect the socialization of drinking habits. The results are compared with outcomes in previous surveys, showing a decreasing trend in the prevalence of alcohol-impaired drivers over time.
Resumo:
Objective Assessing the accuracy of the defining characteristics (DC) of the nursing diagnosis Sedentary Lifestyle (SL) in people with hypertension. Method A cross-sectional study carried out in a referral center in the outpatient care of people with hypertension and diabetes, with a sample of 285 individuals. The form used in the study was designed from operational definitions constructed for each DC of the diagnosis. Four nurses with training to carry out diagnostic inferences did the clinical assessment for the presence of SL. Results The prevalence of SL was 55.8%. Regarding measures of accuracy, the main DC for SL was chooses a daily routine lacking physical exercise, with sensitivity of 100% and specificity of 84.13%. Two DC stood out in the logistic regression, namely: reports preference for activities low in physical activity and poor performance in instrumental activities of daily living (IADL). Conclusion The results allowed identifying the best clinical indicators for SL in hypertensive adults.
Resumo:
PURPOSE: To investigate the effect of intraocular straylight (IOS) induced by white opacity filters (WOF) on threshold measurements for stimuli employed in three perimeters: standard automated perimetry (SAP), pulsar perimetry (PP) and the Moorfields motion displacement test (MDT).¦METHODS: Four healthy young (24-28 years old) observers were tested six times with each perimeter, each time with one of five different WOFs and once without, inducing various levels of IOS (from 10% to 200%). An increase in IOS was measured with a straylight meter. The change in sensitivity from baseline was normalized, allowing comparison of standardized (z) scores (change divided by the SD of normative values) for each instrument.¦RESULTS: SAP and PP thresholds were significantly affected (P < 0.001) by moderate to large increases in IOS (50%-200%). The drop in motion displacement (MD) from baseline with WOF 5, was approximately 5 dB, in both SAP and PP which represents a clinically significant loss; in contrast the change in MD with MDT was on average 1 minute of arc, which is not likely to indicate a clinically significant loss.¦CONCLUSIONS: The Moorfields MDT is more robust to the effects of additional straylight in comparison with SAP or PP.
Resumo:
Various test methods exist for measuring heat of cement hydration; however, most current methods require expensive equipment, complex testing procedures, and/or extensive time, thus not being suitable for field application. The objectives of this research are to identify, develop, and evaluate a standard test procedure for characterization and quality control of pavement concrete mixtures using a calorimetry technique. This research project has three phases. Phase I was designed to identify the user needs, including performance requirements and precision and bias limits, and to synthesize existing test methods for monitoring the heat of hydration, including device types, configurations, test procedures, measurements, advantages, disadvantages, applications, and accuracy. Phase II was designed to conduct experimental work to evaluate the calorimetry equipment recommended from the Phase I study and to develop a standard test procedure for using the equipment and interpreting the test results. Phase II also includes the development of models and computer programs for prediction of concrete pavement performance based on the characteristics of heat evolution curves. Phase III was designed to study for further development of a much simpler, inexpensive calorimeter for field concrete. In this report, the results from the Phase I study are presented, the plan for the Phase II study is described, and the recommendations for Phase III study are outlined. Phase I has been completed through three major activities: (1) collecting input and advice from the members of the project Technical Working Group (TWG), (2) conducting a literature survey, and (3) performing trials at the CP Tech Center’s research lab. The research results indicate that in addition to predicting maturity/strength, concrete heat evolution test results can also be used for (1) forecasting concrete setting time, (2) specifying curing period, (3) estimating risk of thermal cracking, (4) assessing pavement sawing/finishing time, (5) characterizing cement features, (6) identifying incompatibility of cementitious materials, (7) verifying concrete mix proportions, and (8) selecting materials and/or mix designs for given environmental conditions. Besides concrete materials and mix proportions, the configuration of the calorimeter device, sample size, mixing procedure, and testing environment (temperature) also have significant influences on features of concrete heat evolution process. The research team has found that although various calorimeter tests have been conducted for assorted purposes and the potential uses of calorimeter tests are clear, there is no consensus on how to utilize the heat evolution curves to characterize concrete materials and how to effectively relate the characteristics of heat evolution curves to concrete pavement performance. The goal of the Phase II study is to close these gaps.
Resumo:
PURPOSE: EEG and somatosensory evoked potential are highly predictive of poor outcome after cardiac arrest; their accuracy for good recovery is however low. We evaluated whether addition of an automated mismatch negativity-based auditory discrimination paradigm (ADP) to EEG and somatosensory evoked potential improves prediction of awakening. METHODS: EEG and ADP were prospectively recorded in 30 adults during therapeutic hypothermia and in normothermia. We studied the progression of auditory discrimination on single-trial multivariate analyses from therapeutic hypothermia to normothermia, and its correlation to outcome at 3 months, assessed with cerebral performance categories. RESULTS: At 3 months, 18 of 30 patients (60%) survived; 5 had severe neurologic impairment (cerebral performance categories = 3) and 13 had good recovery (cerebral performance categories = 1-2). All 10 subjects showing improvements of auditory discrimination from therapeutic hypothermia to normothermia regained consciousness: ADP was 100% predictive for awakening. The addition of ADP significantly improved mortality prediction (area under the curve, 0.77 for standard model including clinical examination, EEG, somatosensory evoked potential, versus 0.86 after adding ADP, P = 0.02). CONCLUSIONS: This automated ADP significantly improves early coma prognostic accuracy after cardiac arrest and therapeutic hypothermia. The progression of auditory discrimination is strongly predictive of favorable recovery and appears complementary to existing prognosticators of poor outcome. Before routine implementation, validation on larger cohorts is warranted.
Resumo:
We present a new method for constructing exact distribution-free tests (and confidence intervals) for variables that can generate more than two possible outcomes.This method separates the search for an exact test from the goal to create a non-randomized test. Randomization is used to extend any exact test relating to meansof variables with finitely many outcomes to variables with outcomes belonging to agiven bounded set. Tests in terms of variance and covariance are reduced to testsrelating to means. Randomness is then eliminated in a separate step.This method is used to create confidence intervals for the difference between twomeans (or variances) and tests of stochastic inequality and correlation.
Resumo:
This paper explores biases in the elicitation of utilities under risk and the contribution that generalizations of expected utility can make to the resolution of these biases. We used five methods to measure utilities under risk and found clear violations of expected utility. Of the theories studies, prospect theory was most consistent with our data. The main improvement of prospect theory over expected utility was in comparisons between a riskless and a risky prospect(riskless-risk methods). We observed no improvement over expected utility in comparisons between two risky prospects (risk-risk methods). An explanation why we found no improvement of prospect theory over expected utility in risk-risk methods may be that there was less overweighting of small probabilities in our study than has commonly been observed.
Resumo:
We introduce several exact nonparametric tests for finite sample multivariatelinear regressions, and compare their powers. This fills an important gap inthe literature where the only known nonparametric tests are either asymptotic,or assume one covariate only.
Resumo:
It is proved the algebraic equality between Jennrich's (1970) asymptotic$X^2$ test for equality of correlation matrices, and a Wald test statisticderived from Neudecker and Wesselman's (1990) expression of theasymptoticvariance matrix of the sample correlation matrix.
Resumo:
Asymptotic chi-squared test statistics for testing the equality ofmoment vectors are developed. The test statistics proposed aregeneralizedWald test statistics that specialize for different settings by inserting andappropriate asymptotic variance matrix of sample moments. Scaled teststatisticsare also considered for dealing with situations of non-iid sampling. Thespecializationwill be carried out for testing the equality of multinomial populations, andtheequality of variance and correlation matrices for both normal andnon-normaldata. When testing the equality of correlation matrices, a scaled versionofthe normal theory chi-squared statistic is proven to be an asymptoticallyexactchi-squared statistic in the case of elliptical data.