910 resultados para Simultaneous correlation


Relevância:

20.00% 20.00%

Publicador:

Resumo:

The enhanced functional sensitivity offered by ultra-high field imaging may significantly benefit simultaneous EEG-fMRI studies, but the concurrent increases in artifact contamination can strongly compromise EEG data quality. In the present study, we focus on EEG artifacts created by head motion in the static B0 field. A novel approach for motion artifact detection is proposed, based on a simple modification of a commercial EEG cap, in which four electrodes are non-permanently adapted to record only magnetic induction effects. Simultaneous EEG-fMRI data were acquired with this setup, at 7T, from healthy volunteers undergoing a reversing-checkerboard visual stimulation paradigm. Data analysis assisted by the motion sensors revealed that, after gradient artifact correction, EEG signal variance was largely dominated by pulse artifacts (81-93%), but contributions from spontaneous motion (4-13%) were still comparable to or even larger than those of actual neuronal activity (3-9%). Multiple approaches were tested to determine the most effective procedure for denoising EEG data incorporating motion sensor information. Optimal results were obtained by applying an initial pulse artifact correction step (AAS-based), followed by motion artifact correction (based on the motion sensors) and ICA denoising. On average, motion artifact correction (after AAS) yielded a 61% reduction in signal power and a 62% increase in VEP trial-by-trial consistency. Combined with ICA, these improvements rose to a 74% power reduction and an 86% increase in trial consistency. Overall, the improvements achieved were well appreciable at single-subject and single-trial levels, and set an encouraging quality mark for simultaneous EEG-fMRI at ultra-high field.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Background: In longitudinal studies where subjects experience recurrent incidents over a period of time, such as respiratory infections, fever or diarrhea, statistical methods are required to take into account the within-subject correlation. Methods: For repeated events data with censored failure, the independent increment (AG), marginal (WLW) and conditional (PWP) models are three multiple failure models that generalize Cox"s proportional hazard model. In this paper, we revise the efficiency, accuracy and robustness of all three models under simulated scenarios with varying degrees of within-subject correlation, censoring levels, maximum number of possible recurrences and sample size. We also study the methods performance on a real dataset from a cohort study with bronchial obstruction. Results: We find substantial differences between methods and there is not an optimal method. AG and PWP seem to be preferable to WLW for low correlation levels but the situation reverts for high correlations. Conclusions: All methods are stable in front of censoring, worsen with increasing recurrence levels and share a bias problem which, among other consequences, makes asymptotic normal confidence intervals not fully reliable, although they are well developed theoretically.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The simultaneous etherification of isobutene and isoamylenes with ethanol has been studied using macroreticu-lar acid ion-exchange resins as catalyst. Most of the experiments were carried out over Amberlyst-35. In addition,Amberlyst-15 and Purolite CT-275 were also tested. Chemical equilibrium of four chemical reactions was studied:ethyl tert-butyl ether formation, tert-amyl ethyl ether formation from isoamylenes (2-methyl-1-butene and 2-methyl-2-butene) and isomerization reaction between both isoamylenes. Equilibrium data were obtained in a batchwisestirred tank reactor operated at 2.0 MPa and within the temperature range from 323 to 353 K. Experimental molarstandard enthalpy and entropy changes of reaction were determined for each reaction. From these data, the molarenthalpy change of formation of ethyl tert-butyl ether and tert-amyl ethyl ether were estimated. Besides, the chemical equilibrium between both diisobutene dimers, 2,4,4-trimethyl-1-pentene and 2,4,4-trimethyl-2-pentene, wasevaluated. A good agreement between thermodynamic results for the simultaneous etherification carried out in thiswork and those obtained for the isolated ethyl tert-butyl ether and tert-amyl ethyl ether systems was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The determination of gross alpha, gross beta and 226Ra activity in natural waters is useful in a wide range of environmental studies. Furthermore, gross alpha and gross beta parameters are included in international legislation on the quality of drinking water [Council Directive 98/83/EC].1 In this work, a low-background liquid scintillation counter (Wallac, Quantulus 1220) was used to simultaneously determine gross alpha, gross beta and 226Ra activity in natural water samples. Sample preparation involved evaporation to remove 222Rn and its short-lived decay daughters. The evaporation process concentrated the sample ten-fold. Afterwards, a sample aliquot of 8 mL was mixed with 12 mL of Ultima Gold AB scintillation cocktail in low-diffusion vials. In this study, a theoretical mathematical model based on secular equilibrium conditions between 226Ra and its short-lived decay daughters is presented. The proposed model makes it possible to determine 226Ra activity from two measurements. These measurements also allow determining gross alpha and gross beta simultaneously. To validate the proposed model, spiked samples with different activity levels for each parameter were analysed. Additionally, to evaluate the model's applicability in natural water, eight natural water samples from different parts of Spain were analysed. The eight natural water samples were also characterised by alpha spectrometry for the naturally occurring isotopes of uranium (234U, 235U and 238U), radium (224Ra and 226Ra), 210Po and 232Th. The results for gross alpha and 226Ra activity were compared with alpha spectrometry characterization, and an acceptable concordance was obtained.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

To-date, there has been no effective chiral capillary electrophoresis-mass spectrometry (CE-MS) method reported for the simultaneous enantioseparation of the antidepressant drug, venlafaxine (VX) and its structurally-similar major metabolite, O-desmethylvenlafaxine (O-DVX). This is mainly due to the difficulty of identifying MS compatible chiral selector, which could provide both high enantioselectivity and sensitive MS detection. In this work, poly-sodium N-undecenoyl-L,L-leucylalaninate (poly-L,L-SULA) was employed as a chiral selector after screening several dipeptide polymeric chiral surfactants. Baseline separation of both O-DVX and VX enantiomers was achieved in 15min after optimizing the buffer pH, poly-L,L-SULA concentration, nebulizer pressure and separation voltage. Calibration curves in spiked plasma (recoveries higher than 80%) were linear over the concentration range 150-5000ng/mL for both VX and O-DVX. The limit of detection (LOD) was found to be as low as 30ng/mL and 21ng/mL for O-DVX and VX, respectively. This method was successfully applied to measure the plasma concentrations of human volunteers receiving VX or O-DVX orally when co-administered without and with indinivar therapy. The results suggest that micellar electrokinetic chromatography electrospray ionization-tandem mass spectrometry (MEKC-ESI-MS/MS) is an effective low cost alternative technique for the pharmacokinetics and pharmacodynamics studies of both O-DVX and VX enantiomers. The technique has potential to identify drug-drug interaction involving VX and O-DVX enantiomers while administering indinivar therapy.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

One of the most important problems in optical pattern recognition by correlation is the appearance of sidelobes in the correlation plane, which causes false alarms. We present a method that eliminate sidelobes of up to a given height if certain conditions are satisfied. The method can be applied to any generalized synthetic discriminant function filter and is capable of rejecting lateral peaks that are even higher than the central correlation. Satisfactory results were obtained in both computer simulations and optical implementation.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

AIMS: c-Met is an emerging biomarker in pancreatic ductal adenocarcinoma (PDAC); there is no consensus regarding the immunostaining scoring method for this marker. We aimed to assess the prognostic value of c-Met overexpression in resected PDAC, and to elaborate a robust and reproducible scoring method for c-Met immunostaining in this setting. METHODS AND RESULTS: c-Met immunostaining was graded according to the validated MetMab score, a classic visual scale combining surface and intensity (SI score), or a simplified score (high c-Met: ≥20% of tumour cells with strong membranous staining), in stage I-II PDAC. A computer-assisted classification method (Aperio software) was developed. Clinicopathological parameters were correlated with disease-free survival (DFS) and overall survival(OS). One hundred and forty-nine patients were analysed retrospectively in a two-step process. Thirty-seven samples (whole slides) were analysed as a pre-run test. Reproducibility values were optimal with the simplified score (kappa = 0.773); high c-Met expression (7/37) was associated with shorter DFS [hazard ratio (HR) 3.456, P = 0.0036] and OS (HR 4.257, P = 0.0004). c-Met expression was concordant on whole slides and tissue microarrays in 87.9% of samples, and quantifiable with a specific computer-assisted algorithm. In the whole cohort (n = 131), patients with c-Met(high) tumours (36/131) had significantly shorter DFS (9.3 versus 20.0 months, HR 2.165, P = 0.0005) and OS (18.2 versus 35.0 months, HR 1.832, P = 0.0098) in univariate and multivariate analysis. CONCLUSIONS: Simplified c-Met expression is an independent prognostic marker in stage I-II PDAC that may help to identify patients with a high risk of tumour relapse and poor survival.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: Because desmoid tumors exhibit an unpredictable clinical course, translational research is crucial to identify the predictive factors of progression in addition to the clinical parameters. The main issue is to detect patients who are at a higher risk of progression. The aim of this work was to identify molecular markers that can predict progression-free survival (PFS). EXPERIMENTAL DESIGN: Gene-expression screening was conducted on 115 available independent untreated primary desmoid tumors using cDNA microarray. We established a prognostic gene-expression signature composed of 36 genes. To test robustness, we randomly generated 1,000 36-gene signatures and compared their outcome association to our define 36-genes molecular signature and we calculated positive predictive value (PPV) and negative predictive value (NPV). RESULTS: Multivariate analysis showed that our molecular signature had a significant impact on PFS while no clinical factor had any prognostic value. Among the 1,000 random signatures generated, 56.7% were significant and none was more significant than our 36-gene molecular signature. PPV and NPV were high (75.58% and 81.82%, respectively). Finally, the top two genes downregulated in no-recurrence were FECH and STOML2 and the top gene upregulated in no-recurrence was TRIP6. CONCLUSIONS: By analyzing expression profiles, we have identified a gene-expression signature that is able to predict PFS. This tool may be useful for prospective clinical studies. Clin Cancer Res; 21(18); 4194-200. ©2015 AACR.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Lorca basin is one of the Neogene basins OS South Eastern Spain. The infilling Tortonian-Messinian deposits are mainly composed OS marls and reach up to 1,200 m in thickness. A biostratigraphic survey OS these deposits, assisted by the determination OS the magnetic polarity reversal pattern Sor most OS these deposits (900 m), has enabled the Tortonian-Messinian chronostratigraphy to be precised. The close sampling space for biostratigraphic determination has enabled the accurate location OS Sour main biostratigraphic events than can be correlated with charactenstic events of the Mediterranean biostratigraphic Zones. In addition, the location OS the TortonianNessinian boundary has been accurately placed at some 150 m below the main gypsurn unit outcropping in the basin. The integrated bio-magnetostratigraphic data fiom the studied section allows a tentative interpretation OS the identified magnetozones. Thus, a correlation to the Geomagnetic Polarity Time Scale is presented for more than 900 m of pre-evaporite Miocene stratigraphic succession fiom the Lorca basin. Moreover, about 15' OS anticlockwise rotation has been detected. Its significance is evaluated in the basin geodynamic framework.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

As malformações cardíacas são as mais freqüentes anomalias congênitas ao nascimento, entretanto, a sua detecção pré-natal pela ultra-sonografia convencional permanece baixa. As ultra-sonografias de terceira e quarta dimensões surgiram no início da década de 90, apresentando grandes aplicações em obstetrícia, principalmente nos casos de diagnósticos duvidosos à ultra-sonografia bidimensional. O spatio-temporal image correlation (STIC) representa grande avanço na área de ultra-som de quarta dimensão; constitui-se em um software acoplado ao aparelho Voluson 730 Expert, que permite a aquisição volumétrica do coração fetal e suas conexões vasculares. As análises volumétricas são realizadas nos modos multiplanar e de renderização, podendo-se também utilizar o Doppler. Apresenta, como grandes vantagens, a aquisição rápida e a possibilidade de análise posterior por especialistas em ecocardiografia fetal. Pode ser aplicada para a pesquisa de quaisquer cardiopatias congênitas, pois permite a aquisição de qualquer plano, diferentemente do ultra-som bidimensional. Sua principal desvantagem está relacionada aos movimentos fetais. A maior difusão do método pode permitir um aumento na detecção de malformações cardíacas, pois possibilita ao ultra-sonografista geral encaminhar, via Internet, os volumes para a análise por especialistas em ecocardiografia fetal.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper reports the method development for the simultaneous determination of methylmercury MeHgþ) and inorganic mercury (iHg) species in seafood samples. The study focused on the extraction and quantification of MeHgþ (the most toxic species) by liquid chromatography coupled to on-line UV irradiation and cold vapour atomic fluorescence spectroscopy (LC-UV-CV-AFS), using HCl 4 mol/L as the extractant agent. Accuracy of the method has been verified by analysing three certified reference materials and different spiked samples. The values found for total Hg and MeHgþ for the CRMs did not differ significantly from certified values at a 95% confidence level, and recoveries between 85% and 97% for MeHgþ, based on spikes, were achieved. The detection limits (LODs) obtained were 0.001 mg Hg/kg for total mercury, 0.0003 mg Hg/kg for MeHgþ and 0.0004 mg Hg/kg for iHg. The quantification limits (LOQs) established were 0.003 mg Hg/kg for total mercury, 0.0010 mg Hg/kg for MeHgþ and 0.0012 mg Hg/kg for iHg. Precision for each mercury species was established, being 12% in terms of RSD in all cases. Finally, the developed method was applied to 24 seafood samples from different origins and total mercury contents. The concentrations for Total Hg, MeHg and iHg ranged from 0.07 to 2.33, 0.003-2.23 and 0.006-0.085 mg Hg/kg, respectively. The established analytical method allows to obtain results for mercury speciation in less than 1 one hour including both, sample pretreatment and measuring step.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objectives: To correlate the chronic stimulated electrode position on postoperative MRI with the clinical response obtained in PD patients. Material and Method: We retrospectively reviewed 14 consecutive parkinsonian patients who were selected for STN-DBS surgery. Coordinates were determined on an IR T2 MRI coronal section per pendicular to AC-PC plane 3 mm posterior to midcommissural point (MCP) and 12 mm lateral to the midline the inferior aspect of subthalamic region. A CRW stereotactic frame was used for the surgical procedure. A 3D IR T2 MRI was performed postoperatively to determine the location of the stimulated contact in each patient. The clinical results were assessed independently by the neurological team. Results: All but 2 patients had monopolar stimulation. The mean coordinates of the stimulated contacts were: AP ^ ÿ4:23G1:4, Lat ^ 1:12G0:15, Vert ^ ÿ4:1 G2:7 to the MCP. With a mean follow-up of 8 months, all stimulated patients had a significant clinical improvement (preop/postop «ON» UPDRS: 25:8G7:0= 23:3 G8:6; preop/postop «OFF» UPDRS: 50:2G11:4=26:0 G7:8), 60% of them without any antiparkinsonian drug. Conclusion: According to the stereotactic atlas of Schaltenbrand and Warren and the 3D shape of the STN, our results show that our targetting is accurate and almost all the stimulated contacts are comprised in the STN volume. This indicates that MRI is a safe, precise and reproducible procedure for targetting the STN. The location of the stimulated contact within the STN volume is a good predictor of the clinical results.