985 resultados para Respirators (Medical equipment)
Resumo:
This study presents a reproducible, cost-effective in vitro encrustation model and, furthermore, describes the effects of components of the artificial urine and the presence of agents that modify the action of urease on encrustation on commercially available ureteral stents. The encrustation model involved the use of small-volume reactors (700 mL) containing artificial urine and employing an orbital incubator (at 37 degrees C) to ensure controlled stirring. The artificial urine contained sources of calcium and magnesium (both as chlorides), albumin and urease. Alteration of the ratio (% w/w) of calcium salt to magnesium salt affected the mass of encrustation, with the greatest encrustation noted whenever magnesium was excluded from the artificial urine. Increasing the concentration of albumin, designed to mimic the presence of protein in urine, significantly decreased the mass of both calcium and magnesium encrustation until a plateau was observed. Finally, exclusion of urease from the artificial urine significantly reduced encrustation due to the indirect effects of this enzyme on pH. Inclusion of the urease inhibitor, acetohydroxamic acid, or urease substrates (methylurea or ethylurea) into the artificial medium markedly reduced encrustation on ureteral stents. In conclusion, this study has described the design of a reproducible, cost-effective in vitro encrustation model. Encrustation was markedly reduced on biomaterials by the inclusion of agents that modify the action of urease. These agents may, therefore, offer a novel clinical approach to the control of encrustation on urological medical devices. (c) 2005 Wiley Periodicals, Inc.
Resumo:
Background & Aims: Wide between-center variation in adenoma detection rates (ADRs) was observed in the U.K. Flexible Sigmoidoscopy Screening Trial (overall, 12.1%; range, 8.6%-15.9%; P <0.0001). The aim of this study was to determine whether the observed differences could be attributed to varying performance by endoscopists, to examine the effect of experience on performance, and to identify an attainable, standard ADR to which endoscopists could aspire.
Methods: Thirteen medical endoscopists, one per trial center, each performed about 3000 examinations (200 per month) using the same equipment and protocol. Overall and monthly ADRs were compared using multivariable logistic regression.
Results: Differences in ADRs were not explained by patient characteristics, incidence of colorectal cancer in the local population, or the endoscopists' medical specialty or previous experience. Average ADRs increased significantly with screening experience (up to 400 examinations). Endoscopists were classified as higher, intermediate, or lower adenoma detectors, and performance levels were maintained over time. Higher detectors had ADRs of 15% overall (men, 20%; women, 10%) and also detected more adenomas per case (higher/lower detectors, 21.7/10.4 adenomas per :100 examinations).
Conclusions: The differences in ADRs were due to variation in performance of the endoscopists. Long-term follow-up will determine whether this variation is clinically important. We suggest that the standards in higher detecting centers should be achievable by all endoscopists screening unscreened populations aged older than 55 years. Endoscopists should aim to stay above the lower 95% confidence interval band for 200 examinations (10% overall; 5% in women, 15% in men).
Evolving European guidance on the medical management of neovascular age-related macular degeneration