991 resultados para Radiology, nuclear medicine


Relevância:

80.00% 80.00%

Publicador:

Resumo:

Radioimmunodetection of tumours with monoclonal antibodies is becoming an established procedure. Positron emission tomography (PET) shows better resolution than normal gamma camera single photon emission tomography and can provide more precise quantitative data. Thus, in the present study, these powerful methods have been combined to perform radioimmuno PET (RI-PET). Monoclonal antibodies directed against carcinoembryonic antigen (CEA) an IgG, its F(ab')2 and a mouse-human chimeric IgG derived from it were labelled with 124I, a positron-emitting radionuclide with a convenient physical half-life of four days. Mice, xenografted with a CEA-producing human colon carcinoma, were injected with the 124I-MAb and the tumours were visualized using PET. The concentrations of 124I in tumour and normal tissue were determined by both PET and direct radioactivity counting of the dissected animals, with very good agreement. To allow PET quantification, a procedure was established to account for the presence of radioactivity during the absorption correction measurement (transmission scan). Comparison of PET and tissue counting indicates that this novel combination of radioimmunolocalization and PET (RI-PET) will provide, in addition to more precise diagnosis, more accurate radiation dosimetry for radioimmunotherapy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: We asked whether myocardial flow reserve (MFR) by Rb-82 cardiac PET improve the selection of patients eligible for invasive coronary angiography (ICA). Material and Methods: We enrolled 26 consecutive patients with suspected or known coronary artery disease who performed dynamic Rb-82 PET/CT and (ICA) within 60 days; 4 patients who underwent revascularization or had any cardiovascular events between PET and ICA were excluded. Myocardial blood flow at rest (rMBF), at stress with adenosine (sMBF) and myocardial flow reserve (MFR=sMBF/rMBF) were estimated using the 1-compartment Lortie model (FlowQuant) for each coronary arteries territories. Stenosis severity was assessed using computer-based automated edge detection (QCA). MFR was divided in 3 groups: G1:MFR<1.5, G2:1.5&#8804;MFR<2 and G3:2&#8804;MFR. Stenosis severity was graded as non-significant (<50% or FFR &#8805;0.8), intermediate (50%&#8804;stenosis<70%) and severe (&#8805;70%). Correlation between MFR and percentage of stenosis were assessed using a non-parametric Spearman test. Results: In G1 (44 vessels), 17 vessels (39%) had a severe stenosis, 11 (25%) an intermediate one, and 16 (36%) no significant stenosis. In G2 (13 vessels), 2 (15%) vessels presented a severe stenosis, 7 (54%) an intermediate one, and 4 (31%) no significant stenosis. In G3 (9 vessels), 0 vessel presented a severe stenosis, 1 (11%) an intermediate one, and 8 (89%) no significant stenosis. Of note, among 11 patients with 3-vessel low MFR<1.5 (G1), 9/11 (82%) had at least one severe stenosis and 2/11 (18%) had at least one intermediate stenosis. There was a significant inverse correlation between stenosis severity and MFR among all 66 territories analyzed (rho= -0.38, p=0.002). Conclusion: Patients with MFR>2 could avoid ICA. Low MFR (G1, G2) on a vessel-based analysis seems to be a poor predictor of severe stenosis severity. Patients with 3-vessel low MFR would benefit from ICA as they are likely to present a significant stenosis in at least one vessel.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Neuroblastoma (NBL) is the commonest extra-cranial solid tumor in children and the leading cause of cancer related deaths in childhood between the age of 1 to 4 years. NBL may behave in very different ways, from the less aggressive stage 4S NBL or congenital forms that may resolve without treatment in up to 90% of the children, to the high-risk disseminated stage 4 disease in older children with a cure rate of 35 to 40%. Initial staging is crucial for effective management and radiolabeled metaiodobenzylguanidine (MIBG) with iodine-123 is a powerful tool with a sensitivity around 90% and a specificity close to 100% for the diagnosis of NBL. MIBG scintigraphy is used routinely and is mandatory in most investigational clinical trials both for the initial staging of the disease, the evaluation of the response to treatment, as well as for the detection of recurrence during follow-up. With respect to outcome of children presenting disseminated stage 4 NBL, the role of post-therapeutic [(123)I]MIBG scan has been investigated by several groups but so far there is no consensus whereas a complete or very good partial response as assessed by MIBG may be of prognostic value. NBL needs a multimodality approach at diagnosis and during follow-up and MIBG scintigraphy keeps its pivotal role, in particular with respect to bone marrow involvement and/or cortical bone metastases.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

A crucial method for investigating patients with coronary artery disease (CAD) is the calculation of the left ventricular ejection fraction (LVEF). It is, consequently, imperative to precisely estimate the value of LVEF--a process that can be done with myocardial perfusion scintigraphy. Therefore, the present study aimed to establish and compare the estimation performance of the quantitative parameters of the reconstruction methods filtered backprojection (FBP) and ordered-subset expectation maximization (OSEM). METHODS: A beating-heart phantom with known values of end-diastolic volume, end-systolic volume, and LVEF was used. Quantitative gated SPECT/quantitative perfusion SPECT software was used to obtain these quantitative parameters in a semiautomatic mode. The Butterworth filter was used in FBP, with the cutoff frequencies between 0.2 and 0.8 cycles per pixel combined with the orders of 5, 10, 15, and 20. Sixty-three reconstructions were performed using 2, 4, 6, 8, 10, 12, and 16 OSEM subsets, combined with several iterations: 2, 4, 6, 8, 10, 12, 16, 32, and 64. RESULTS: With FBP, the values of end-diastolic, end-systolic, and the stroke volumes rise as the cutoff frequency increases, whereas the value of LVEF diminishes. This same pattern is verified with the OSEM reconstruction. However, with OSEM there is a more precise estimation of the quantitative parameters, especially with the combinations 2 iterations à 10 subsets and 2 iterations à 12 subsets. CONCLUSION: The OSEM reconstruction presents better estimations of the quantitative parameters than does FBP. This study recommends the use of 2 iterations with 10 or 12 subsets for OSEM and a cutoff frequency of 0.5 cycles per pixel with the orders 5, 10, or 15 for FBP as the best estimations for the left ventricular volumes and ejection fraction quantification in myocardial perfusion scintigraphy.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Our aim was to evaluate the role of forced diuresis in improving the diagnostic accuracy of abdominopelvic (18)F-FDG PET. METHODS: Thirty-two patients were enrolled. Besides the presence of known intravesical tumors or undefined renal lesions on the initial PET scan, the inclusion criterion was the appearance of indeterminate or equivocal (18)F-FDG foci that extended along the course of the urinary tract and could not confidently be separated from urinary activity. For each patient, a second abdominopelvic PET study was performed after intravenous injection of 0.5 mg of furosemide per kilogram of body weight (maximum, 40 mg) coupled with parenteral infusion of physiologic saline. RESULTS: Forced diuresis coupled with parenteral hydration eliminated any significant (18)F-FDG activity from the lower urinary tract in 31 (97%) of 32 patients after the bladder had been voided 3 successive times. Twelve intravesical lesions were visualized with outstanding clarity, whereas radiologic suspicion of locally recurrent bladder tumors was ruled out in 3 patients. Among 14 indeterminate or equivocal extravesical foci, 7 were deemed of no clinical value because they disappeared after furosemide challenge, whereas 7 persisting foci were proven to be true-positive PET findings. The performance of (18)F-FDG PET in characterizing 3 renal-space-occupying lesions could not be improved by our protocol. CONCLUSION: Furosemide challenge has the potential to noninvasively resolve the inherent (18)F-FDG contrast handicap in the lower urinary tract.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Colon carcinoma multicellular spheroids were incubated in vitro with radiolabelled MAbs. The more rapid penetration of fragments as compared to intact MAbs was clearly demonstrated. For the study of antibody localization in tumors in vivo, the model of nude mice with ligated kidneys was used. Although very artificial, this model allowed to demonstrate that, without urinary excretion, Fab fragments accumulated more rapidly into the tumor than intact MAbs and disappeared faster from the blood. This difference was less striking for F(ab')2 fragments. In the liver a decreased accumulation of both types of fragments as compared to intact MAbs was observed. Concerning radioimmunotherapy we think that Fab fragments are not useful because of their too short half-life in the circulation and in tumor and because they will probably be too toxic for the kidneys. Intact MAbs and F(ab')2 fragments have each their advantages. Intact MAbs show highest tumor accumulation in mice without ligated kidney, however, they remain mostly on the periphery of tumor nodules, as shown by autoradiography. F(ab')2 fragments have been found to penetrate deeper into the tumor and to accumulate less in the liver. It might be therefore an advantage to combine intact MAbs with F(ab')2 fragments, so that in the tumor two different regions could be attacked whereas in normal tissues toxicity could be distributed to different organs such as to the liver with intact MAbs and to the kidney with F(ab')2 fragments.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

During one week, beginning 18 days after transplantation, nude mice bearing human colon carcinoma ranging from 115 to 943 mm3 (mean 335 mm3) were treated by repeated intravenous injections of either iodine-131-(131I) labeled intact antibodies or 131I-labeled corresponding F(ab')2 fragments of a pool of four monoclonal antibodies (MAbs) directed against distinct epitopes of carcinoembryonic antigen (CEA). Complete tumor remission was observed in 8 of 10 mice after therapy with F(ab')2 and 6 of the animals survived 10 mo in good health. In contrast, after treatment with intact MAbs, tumors relapsed in 7 of 8 mice after remission periods of 1 to 3.5 mo despite the fact that body weight loss and depression of peripheral white blood cells, symptoms of radiation toxicity, and the calculated radiation doses for liver, spleen, bone, and blood were increased or equal in these animals as compared to mice treated with F(ab')2.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: This study aimed to evaluate the efficacy and toxicity of radioimmunotherapy (RIT) in recurrent lymphoma after hematopoietic stem cell transplantation (HSCT). METHODS: We reviewed 9 patients, 7 with follicular lymphoma (DLBCL), 1 with mantle cell lymphoma (MCL), and 1 with diffuse large B-cell lymphoma treated with Y-ibritumomab tiuxetan 6 to 140 months after HSCT. Patients underwent In-ibritumomab scintigraphy and were treated 1 week later with standard 14.8 MBq/kg (n = 4) or 11.1 MBq/kg (n = 4) Y-ibritumomab. One patient who had allo-HSCT had reduced activity (70%) treatment. RESULTS: Among the 7 FL patients, we observed complete response (CR) in 2 patients and partial response (PR) in 5 patients. One patient with CR relapsed after 15 months; the other persisted 43.5 months after RIT. Of 5 patients with PR, 3 relapsed between 13 and 17 months; 1 persisted until unrelated death at 11.5 months. The fifth patient with PR received adoptive immunotherapy and improved to metabolic (FDG-PET) CR that persists 45.5 and 41 months after Y-ibritumomab and immunotherapy, respectively. Patients with MCL and DLBCL progressed or experienced stabilization (5 months), respectively. Six patients had grade 1 to 3 bone marrow (BM) toxicity and recovered within 3 months. Three patients having Y-ibritumomab 6, 14, and 24 months after HSCT experienced grade 4 BM toxicity. One of them (RIT 24 months after HSCT) recovered after 3 months, another delayed after 9 months, and the third patient only partially recovered, eventually developed myelodysplasia, and was allografted. CONCLUSIONS: Radioimmunotherapy after HSCT is an effective rescue therapy in FL. However, BM toxicity may be important; 3 of 8 patients treated with standard Y-ibritumomab activity experienced grade 4 BM toxicity, with incomplete recovery 3 months after RIT in 2 patients, both treated early (6 and 14 months) after HSCT.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Biodistribution and tumor uptake of a chimeric human-mouse monoclonal antibody (MAb) and the original mouse MAb have been comparatively studied. METHODS: Eighteen patients with suspected colorectal cancer scheduled for surgery underwent immunoscintigraphy with 123I-labeled chimeric anti-CEA MAb. Iodine-125 and 131I trace-labeled chimeric and original mouse MAb were simultaneously injected for biodistribution studies. RESULTS: Similar serum kinetics and a low immunogenicity were observed for both antibodies. Mean binding capacity to CEA measured in PBS after radiolabeling was identical for both MAbs and it was slightly decreased when measured in serum 1-4 hr after injection. Radiochromatograms of patients sera showed immune complex formation related to the amount of circulating CEA. Postoperative ex vivo radioactivity counting in tissue samples revealed similar antibody distributions with notably similar antibody uptakes in tumors. High tumor uptakes (between 0.02 to 0.06% injected dose per g) were observed in 3 of 13 patients operated for primary or metastatic colorectal cancer. CONCLUSION: In this dual-label technique, the radioiodinated anti-CEA IgG4 chimeric MAb and the original mouse IgG1 MAb were shown to have very similar behavior in colorectal cancer patients.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Aim: 5-fluoro-2'-deoxyuridine (FdUrd) depletes the endogenous 5'-deoxythymidine triphosphate (dTTP) pool. We hypothesized whether uptake of exogenous dThd analogues could be favoured through a feedback enhanced salvage pathway and studied the FdUrd effect on cellular uptake of 3'-deoxy-3'-18F-fluorothymidine (18F-FLT) and 5-125I-iodo-2'-deoxyuridine (125I-IdUrd) in different cancer cell lines in parallel. Methods: Cell uptake of 18F-FLT and 125I-IdUrd was studied in 2 human breast, 2 colon cancer and 2 glioblastoma lines. Cells were incubated with/without 1 µmol/l FdUrd for 1 h and, after washing, with 1.2 MBq 18F-FLT or 125I-IdUrd for 0.3 to 2 h. Cell bound 18F-FLT and 125I-IdUrd was counted and expressed in % incubated activity (%IA). Kinetics of 18F-FLT cell uptake and release were studied with/without FdUrd modulation. 2'-3H-methyl-fluorothymidine (2'-3H-FLT) uptake with/without FdUrd pretreatment was tested on U87 spheroids and monolayer cells. Results: Basal uptake at 2 h of 18F-FLT and 125I-IdUrd was in the range of 0.8-1.0 and 0.4-0.6 Bq/cell, respectively. FdUrd pretreatment enhanced 18F-FLT and 125I-IdUrd uptake 1.2-2.1 and 1.7-4.4 fold, respectively, while co-incubation with excess thymidine abrogated all 18F-FLT uptake. FdUrd enhanced 18F-FLT cellular inflow in 2 breast cancer lines by factors of 1.8 and 1.6, respectively, while outflow persisted at a slightly lower rate. 2'-3H-FLT basal uptake was very low while uptake increase after FdUrd was similar in U87 monolayer cells and spheroids. Conclusions: Basal uptake of 18F-FLT was frequently higher than that of 125I-IdUrd but FdUrd induced uptake enhancement was stronger for 125I-IdUrd in five of six cell lines. 18F-FLT outflow from cells might be an explanation for the observed difference with 125I-IdUrd.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Toperform a meta-analysis of FDG-PET performances in the diagnosis of largevessels vasculitis (Giant Cell Arteritis (GCA) associated or not withPolymyalgia Rheumatica(PMR), Takayasu). Materials and methods : The MEDLINE,Cochrane Library, Embase were searched for relevant original articlesdescribing FDG-PET for vasculitis assessment, using MesH terms ("GiantCell Arteritis or Vasculitis" AND "PET"). Criteria for inclusionwere:(1)FDG-PET for diagnosis of vasculitis(2)American College of Rheumatologycriteria as reference standard(3)control group. After data extraction, analyseswere performed using a random-effects model. Results : Of 184 citations(database search and references screening),70 articles were reviewed of which12 eligible studies were extracted (sensitivity range from 32% to 97%). 7studies fulfilled all inclusion criteria. Owing to overlapping population, 1study was excluded. Statistical heterogeneity justified the random-effectsmodel. Pooled 6 studies analysis(116 vasculitis,224 controls) showed a 81%sensitivity (95%CI:70-89%);a 89% specificity (95%CI:77-95%);a 85%PPV(95%CI:63-95%); a 90% NPV(95%CI:79-95%);a 7.1 positive LR(95%CI:3.4-14.9); a0.2 negative LR(95%CI:0.14-0.35) and 90.1 DOR(95%CI: 18.6-437). Conclusion :FDG-PET has good diagnostic performances in the detection of large vesselsvasculitis. Its promising role could be extended to follow up patients undertreatment, but further studies are needed to confirm this possibility.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

Normal rats were injected intravenously with 131I- and 125I-labeled intact murine and chimeric mouse-human monoclonal antibodies directed against carcinoembryonic antigen or with the corresponding F(ab')2 fragments. At different times after injection, individual animals were killed and radioactivity of blood and major organs, including bones and bone marrow, was determined. Ratios comparing radioactivity concentration in different tissues with that of bone marrow were calculated and found to remain stable during several effective half-lives of the antibodies. Mean bone marrow radioactivity was 35% (range, 29%-40%) of that of blood and 126% (range, 108%-147%) of that of liver after injection of intact Mabs or F(ab')2 fragments. In nude rats bearing human colon carcinoma xenografts producing carcinoembryonic antigen, relative bone marrow radioactivity was slightly lower than that in normal rats.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

The purposes of this study were to characterize the performance of a 3-dimensional (3D) ordered-subset expectation maximization (OSEM) algorithm in the quantification of left ventricular (LV) function with (99m)Tc-labeled agent gated SPECT (G-SPECT), the QGS program, and a beating-heart phantom and to optimize the reconstruction parameters for clinical applications. METHODS: A G-SPECT image of a dynamic heart phantom simulating the beating left ventricle was acquired. The exact volumes of the phantom were known and were as follows: end-diastolic volume (EDV) of 112 mL, end-systolic volume (ESV) of 37 mL, and stroke volume (SV) of 75 mL; these volumes produced an LV ejection fraction (LVEF) of 67%. Tomographic reconstructions were obtained after 10-20 iterations (I) with 4, 8, and 16 subsets (S) at full width at half maximum (FWHM) gaussian postprocessing filter cutoff values of 8-15 mm. The QGS program was used for quantitative measurements. RESULTS: Measured values ranged from 72 to 92 mL for EDV, from 18 to 32 mL for ESV, and from 54 to 63 mL for SV, and the calculated LVEF ranged from 65% to 76%. Overall, the combination of 10 I, 8 S, and a cutoff filter value of 10 mm produced the most accurate results. The plot of the measures with respect to the expectation maximization-equivalent iterations (I x S product) revealed a bell-shaped curve for the LV volumes and a reverse distribution for the LVEF, with the best results in the intermediate range. In particular, FWHM cutoff values exceeding 10 mm affected the estimation of the LV volumes. CONCLUSION: The QGS program is able to correctly calculate the LVEF when used in association with an optimized 3D OSEM algorithm (8 S, 10 I, and FWHM of 10 mm) but underestimates the LV volumes. However, various combinations of technical parameters, including a limited range of I and S (80-160 expectation maximization-equivalent iterations) and low cutoff values (&lt; or =10 mm) for the gaussian postprocessing filter, produced results with similar accuracies and without clinically relevant differences in the LV volumes and the estimated LVEF.

Relevância:

80.00% 80.00%

Publicador:

Resumo:

PURPOSE: The biokinetics and dosimetry of (111)In-DOTA-NOC-ATE (NOCATE), a high-affinity ligand of SSTR-2 and SSTR-5, and (111)In-DTPA-octreotide (Octreoscan?, OCTREO) were compared in the same patients. METHODS: Seventeen patients (10 men, 7 women; mean age 60 years), referred for an OCTREO scan for imaging of a neuroendocrine tumour (15), thymoma (1) or medullary thyroid carcinoma (1), agreed to undergo a second study with NOCATE. Whole-body anterior-posterior scans were recorded 0.5 (100 % reference scan), 4, 24 and 48 h (17 patients) and 120 h (5 patients) after injection. In 16 patients the OCTREO scan (178&#8201;±&#8201;15 MBq) was performed 16&#8201;±&#8201;5 days before the NOCATE scan (108&#8201;±&#8201;14 MBq) with identical timing; 1 patient had the NOCATE scan before the OCTREO scan. Blood samples were obtained from 14 patients 5 min to 48 h after injection. Activities expressed as percent of the initial (reference) activity in the whole body, lung, kidney, liver, spleen and blood were fitted to biexponential or single exponential functions. Dosimetry was performed using OLINDA/EXM. RESULTS: Initial whole-body, lung and kidney activities were similar, but retention of NOCATE was higher than that of OCTREO. Liver and spleen uptakes of NOCATE were higher from the start (p&#8201;<&#8201;0.001) and remained so over time. Whole-body activity showed similar &#945; and &#946; half-lives, but the &#946; fraction of NOCATE was double that of OCTREO. Blood T (1/2)&#946; for NOCATE was longer (19 vs. 6 h). As a result, the effective dose of NOCATE (105 &#956;Sv/MBq) exceeded that of OCTREO (52 &#956;Sv/MBq), and the latter result was similar to the ICRP 106 value of 54 &#956;Sv/MBq. Differential activity measurement in blood cells and plasma showed an average of <5 % of NOCATE and OCTREO attached to globular blood components. CONCLUSION: NOCATE showed a slower clearance from normal tissues and its effective dose was roughly double that of OCTREO.