599 resultados para Radiofrequency Coils
Resumo:
OBJECTIVES The aim of this study was to evaluate irrigated-tip catheter for ablation of intraatrial reentrant tachycardias late after surgical repair of congenital heart disease. BACKGROUND In congenital heart disease patients, the right atrium can be markedly enlarged with areas of low blood flow. Radiofrequency (RF) lesion creation may be hampered by insufficient electrode cooling at sites with low blood flow. METHODS Thirty-six consecutive patients with intraatrial reentrant tachycardia refractory to antiarrhythmic therapy from two centers were included in the study. Entrainment pacing and electroanatomic mapping (CARTO) were used to delineate reentrant circuits and critical isthmus sites. RF ablation was performed using an irrigated-tip catheter (Navistar Thermocool). RESULTS Fifty-two intraatrial reentrant tachycardia circuits were identified, and 48 were targeted with RF ablation. RF ablation was performed using a mean of 13 +/- 11 irrigated RF applications per tachycardia isthmus with a mean power of 36 +/- 8 W. In a historical control group of congenital heart disease patients managed with conventional catheter ablation, the number of lesions per isthmus was higher (23 +/- 11) and mean power was lower (27 +/- 14 W). Acute success was achieved in 45 intraatrial reentrant tachycardias (94% of targeted tachycardias and 87% of all tachycardias). After a mean follow-up of 17 +/- 7 months, 33 (92%) of 36 patients were free of recurrence. Five patients (14%) developed paroxysmal atrial fibrillation. CONCLUSIONS The combination of modern techniques including electroanatomic mapping and catheter irrigation allows safe and highly effective ablation of intraatrial reentrant tachycardia in patients with surgically repaired congenital heart disease.
Resumo:
OBJECTIVES This study was conducted to determine if an additional procedural endpoint of unexcitability (UE) to pacing along the ablation line reduces recurrence of atrial fibrillation (AF) or atrial tachycardia (AT) after radiofrequency catheter ablation. BACKGROUND AF/AT recurrence is common after pulmonary vein isolation (PVI). METHODS We included 102 patients from 2 centers (age 63 ± 10 years; 33 women; left atrium 38 ± 7 mm; left ventricular ejection fraction 61 ± 6%) with symptomatic paroxysmal AF. A 3-dimensional mapping system and circumferential mapping catheter were used in all patients for PVI. In group 1 (n = 50), the procedural endpoint was bidirectional block across the ablation line. In group 2 (n = 52), additional UE to bipolar pacing at an output of 10 mA and 2-ms pulse width was required. The primary endpoint was freedom from any AF/AT (>30 s) after discontinuation of antiarrhythmic drugs. RESULTS Procedural endpoints were successfully achieved in all patients. Procedure duration was significantly longer in group 2 (185 ± 58 min vs. 139 ± 57 min; p < 0.001); however, fluoroscopy times were not different (23 ± 9 min vs. 23 ± 9 min; p = 0.49). After a follow-up of 12 months in all patients, 26 patients (52%) in group 1 versus 43 (82.7%) in group 2 were free from any AF/AT (p = 0.001) after a single procedure. No major complications occurred. CONCLUSIONS The use of pacing to ensure UE along the PVI line markedly improved near-term single-procedure success, compared with demonstration of bidirectional block alone. This additional endpoint significantly improved patient outcomes after PVI. (Unexcitability Along the Ablation as an Endpoint for Atrial Fibrillation Ablation; NCT01724437).
Resumo:
Catheter ablation for paroxysmal atrial fibrillation is a meanwhile established therapy option, which is most frequently performed using radiofrequency ablation. Mid-term success rate of 70 % are achievable with a single ablation procedure. However, the mechanistics of persistent atrial fibrillation are less well understood and catheter ablation is a far more challenging procedure. Different ablation approaches are being performed to treat persistent atrial fibrillation ranging from sole pulmonary vein isolation to additional ablation of fractionated electrograms aiming for termination of atrial fibrillation. Thus far, it has not been investigated which strategy is most successful in treating persistent atrial fibrillation. After extended ablation of atrial fibrillation, occurrence of organized atrial arrhythmias is not uncommon and can be successfully ablated. These consecutive arrhythmias can be considered as a next step towards stable sinus rhythm after repeat ablation. Improvement of mapping methods as well as a better understanding of mechanisms of atrial fibrillation may increase success rate of catheter ablation of persistent atrial fibrillation and may also help to improve success rate of these complex procedures.
Resumo:
The γ-aminobutyric acid (GABA) system has been proposed as a target for novel antidepressant and anxiolytic treatments. Emerging evidence suggests that gabapentin (GBP), an anticonvulsant drug that significantly increases brain GABA levels, is effective in the treatment of anxiety disorders. The current study was designed to measure prefrontal and occipital GABA levels in medication-free healthy subjects after taking 0 mg, 150 mg and 300 mg GBP. Subjects were scanned on a 3T scanner using a transmit-receive head coil that provided a relatively homogenous radiofrequency field to obtain spectroscopy measurement in the medial prefrontal (MPFC) and occipital cortex (OCC). There was no dose-dependent effect of GBP on GABA levels in the OCC or MPFC. There was also no effect on Glx, choline or N-acetyl-aspartate concentrations. The previously reported finding of increased GABA levels after GBP treatment is not evident for healthy subjects at the dose of 150 and 300 mg. As a result, if subjects are scanned on a 3T scanner, low dose GPB is not useful as an experimental challenge agent on the GABA system.
Resumo:
In children with structurally normal hearts, the mechanisms of arrhythmias are usually the same as in the adult patient. Some arrhythmias are particularly associated with young age and very rarely seen in adult patients. Arrhythmias in structural heart disease may be associated either with the underlying abnormality or result from surgical intervention. Chronic haemodynamic stress of congenital heart disease (CHD) might create an electrophysiological and anatomic substrate highly favourable for re-entrant arrhythmias. As a general rule, prescription of antiarrhythmic drugs requires a clear diagnosis with electrocardiographic documentation of a given arrhythmia. Risk-benefit analysis of drug therapy should be considered when facing an arrhythmia in a child. Prophylactic antiarrhythmic drug therapy is given only to protect the child from recurrent supraventricular tachycardia during this time span until the disease will eventually cease spontaneously. In the last decades, radiofrequency catheter ablation is progressively used as curative therapy for tachyarrhythmias in children and patients with or without CHD. Even in young children, procedures can be performed with high success rates and low complication rates as shown by several retrospective and prospective paediatric multi-centre studies. Three-dimensional mapping and non-fluoroscopic navigation techniques and enhanced catheter technology have further improved safety and efficacy even in CHD patients with complex arrhythmias. During last decades, cardiac devices (pacemakers and implantable cardiac defibrillator) have developed rapidly. The pacing generator size has diminished and the pacing leads have become progressively thinner. These developments have made application of cardiac pacing in children easier although no dedicated paediatric pacing systems exist.
Resumo:
AIM The effect of long-term high-intensity statin therapy on coronary atherosclerosis among patients with acute ST-segment elevation myocardial infarction (STEMI) is unknown. The aim of this study was to quantify the impact of high-intensity statin therapy on plaque burden, composition, and phenotype in non-infarct-related arteries of STEMI patients undergoing primary percutaneous coronary intervention (PCI). METHODS AND RESULTS Between September 2009 and January 2011, 103 STEMI patients underwent intravascular ultrasonography (IVUS) and radiofrequency ultrasonography (RF-IVUS) of the two non-infarct-related epicardial coronary arteries (non-IRA) after successful primary PCI. Patients were treated with high-intensity rosuvastatin (40 mg/day) throughout 13 months and serial intracoronary imaging with the analysis of matched segments was available for 82 patients with 146 non-IRA. The primary IVUS end-point was the change in per cent atheroma volume (PAV). After 13 months, low-density lipoprotein cholesterol (LDL-C) had decreased from a median of 3.29 to 1.89 mmol/L (P < 0.001), and high-density lipoprotein cholesterol (HDL-C) levels had increased from 1.10 to 1.20 mmol/L (P < 0.001). PAV of the non-IRA decreased by -0.9% (95% CI: -1.56 to -0.25, P = 0.007). Patients with regression in at least one non-IRA were more common (74%) than those without (26%). Per cent necrotic core remained unchanged (-0.05%, 95% CI: -1.05 to 0.96%, P = 0.93) as did the number of RF-IVUS defined thin cap fibroatheromas (124 vs. 116, P = 0.15). CONCLUSION High-intensity rosuvastatin therapy over 13 months is associated with regression of coronary atherosclerosis in non-infarct-related arteries without changes in RF-IVUS defined necrotic core or plaque phenotype among STEMI patients.
Resumo:
Postmortem MRI (PMMR) examinations are seldom performed in legal medicine due to long examination times, unfamiliarity with the technique, and high costs. Furthermore, it is difficult to obtain access to an MRI device used for patients in clinical settings to image an entire human body. An alternative is available: ex situ organ examination. To our knowledge, there is no standardized protocol that includes ex situ organ preparation and scanning parameters for postmortem MRI. Thus, our objective was to develop a standard procedure for ex situ heart PMMR examinations. We also tested the oily contrast agent Angiofil® commonly used for PMCT angiography, for its applicability in MRI. We worked with a 3 Tesla MRI device and 32-channel head coils. Twelve porcine hearts were used to test different materials to find the best way to prepare and place organs in the device and to test scanning parameters. For coronary MR angiography, we tested different mixtures of Angiofil® and different injection materials. In a second step, 17 human hearts were examined to test the procedure and its applicability to human organs. We established two standardized protocols: one for preparation of the heart and another for scanning parameters based on experience in clinical practice. The established protocols enabled a standardized technical procedure with comparable radiological images, allowing for easy radiological reading. The performance of coronary MR angiography enabled detailed coronary assessment and revealed the utility of Angiofil® as a contrast agent for PMMR. Our simple, reproducible method for performing heart examinations ex situ yields high quality images and visualization of the coronary arteries.
Resumo:
Background Single procedure success rates of pulmonary vein isolation (PVI) in patients with paroxysmal atrial fibrillation (PAF) are still unsatisfactory. In patients with persistent atrial fibrillation (AF), ablation of complex fractionated atrial electrograms (CFAEs) after PVI results in improved outcomes. Objective We aimed to investigate if PAF-patients with intraprocedurally sustained AF after PVI might benefit from additional CFAE ablation. Methods A total of 1134 consecutive patients underwent a first catheter ablation procedure of PAF between June 2008 and December 2012. In most patients, AF was either not inducible or terminated during PVI. In 68 patients (6%), AF sustained after successful PVI. These patients were randomized to either cardioversion (PVI-alone group; n = 33) or additional CFAE ablation (PVI+CFAE group; n = 35) and followed up every 1–3 months and serial Holter recordings were also obtained. The primary end point was the recurrence of AF/atrial tachycardia (AT) after a blanking period of 3 months. Results Procedure duration (127 ± 6 minutes vs 174 ± 10 minutes), radiofrequency application time (44 ± 3 minutes vs 74 ± 5 minutes), and fluoroscopy time (26 ± 2 minutes vs 41 ± 3 minutes) were longer in the PVI+CFAE group (all P < .001). In 30 of 35 patients (86%) in the PVI+CFAE group, ablation terminated AF. There was no significant group difference with respect to freedom from AF/AT (22 of 33 [67%] vs 22 of 35 [63%]; P = .66). Subsequently, 10 of 11 patients in the PVI-alone group (91%) and 11 of 13 patients in PVI+CFAE group (85%) underwent repeat ablation (P = 1.00). Overall, 29 of 33 [88%] vs 30 of 35 [86%] patients (P = 1.00) were free from AF/AT after 1.4 ± 0.1 vs 1.4 ± 0.2 (P = .87) procedures. Conclusion Patients with sustained AF after PVI in a PAF cohort are rare. Regarding AF/AT recurrence, these patients did not benefit from further CFAE ablation compared to PVI alone, but are exposed to longer procedure duration, fluoroscopy time, and radiofrequency application time.
Resumo:
BACKGROUND Long-term success rates using ablation for persistent atrial fibrillation (AF) are disappointing and usually do not exceed 60%. OBJECTIVES This study sought to compare arrhythmia-free survival between pulmonary vein isolation (PVI) and a stepwise approach (full defrag) consisting of PVI, ablation of complex fractionated electrograms, and additional linear ablation lines in the setting of atrial tachycardias (AT) in patients with persistent AF after PVI. METHODS From November 2010 to February 2013, 205 patients (151 men; 61.7 ± 10.2 years of age) underwent de novo ablation for persistent AF. Subsequently, patients were prospectively randomized to either PVI alone (n = 78) or full defrag (n = 75), with 52 patients not randomized due to AF termination with the original PVI. The primary endpoint was recurrence of any AT after a blanking period of 3 months. RESULTS During the entire study, 241 ablations were performed (mean: 1.59 in the PVI-alone group, 1.55 in the full-defrag group). With the stepwise approach, termination of AF occurred in 45 (60%) patients. However, arrhythmia-free survival did not differ whether patients underwent single or multiple procedures (p = 0.468). Procedure duration, fluoroscopy time, and radiofrequency duration were significantly longer in the full-defrag group (all p < 0.001). CONCLUSIONS A stepwise approach aimed at AF termination does not seem to provide additional benefit over PVI alone in patients with persistent AF, but it is associated with significantly longer procedural and fluoroscopic duration as well as radiofrequency application time. (The Randomized Catheter Ablation of Persist End Atrial Fibrillation Study [CHASE-AF]; NCT01580124).
Resumo:
A new haptic interface device is suggested, which can be used for functional magnetic resonance imaging (fMRI) studies. The basic component of this 1 DOF haptic device are two coils that produce a Lorentz force induced by the large static magnetic field of the MR scanner. A MR-compatible optical angular encoder and a optical force sensor enable the implementation of different control architectures for haptic interactions. The challenge was to provide a large torque, and not to affect image quality by the currents applied in the device. The haptic device was tested in a 3T MR scanner. With a current of up to 1A and a distance of 1m to the focal point of the MR-scanner it was possible to generate torques of up to 4 Nm. Within these boundaries image quality was not affected.
Resumo:
INTRODUCTION Mitral isthmus (MI) ablation is an effective option in patients undergoing ablation for persistent atrial fibrillation (AF). Achieving bidirectional conduction block across the MI is challenging, and predictors of MI ablation success remain incompletely understood. We sought to determine the impact of anatomical location of the ablation line on the efficacy of MI ablation. METHODS AND RESULTS A total of 40 consecutive patients (87% male; 54 ± 10 years) undergoing stepwise AF ablation were included. MI ablation was performed in sinus rhythm. MI ablation was performed from the left inferior PV to either the posterior (group 1) or the anterolateral (group 2) mitral annulus depending on randomization. The length of the MI line (measured with the 3D mapping system) and the amplitude of the EGMs at 3 positions on the MI were measured in each patient. MI block was achieved in 14/19 (74%) patients in group 1 and 15/21 (71%) patients in group 2 (P = NS). Total MI radiofrequency time (18 ± 7 min vs. 17 ± 8 min; P = NS) was similar between groups. Patients with incomplete MI block had a longer MI length (34 ± 6 mm vs. 24 ± 5 mm; P < 0.001), a higher bipolar voltage along the MI (1.75 ± 0.74 mV vs. 1.05 ± 0.69 mV; P < 0.01), and a longer history of continuous AF (19 ± 17 months vs. 10 ± 10 months; P < 0.05). In multivariate analysis, decreased length of the MI was an independent predictor of successful MI block (OR 1.5; 95% CI 1.1-2.1; P < 0.05). CONCLUSIONS Increased length but not anatomical location of the MI predicts failure to achieve bidirectional MI block during ablation of persistent AF.
Resumo:
OBJECTIVES Levels of inflammatory biomarkers associate with changes of coronary atheroma burden in statin-treated patients with stable coronary artery disease. This study sought to determine changes of plaque composition in vivo in relation to high-sensitivity C-reactive protein (hs-CRP) levels in patients with ST-elevation myocardial infarction (STEMI) receiving high-intensity statin therapy. METHODS The IBIS-4 study performed serial (baseline and 13-month), 2-vessel intravascular ultrasound (IVUS) and radiofrequency-IVUS of the non-infarct-related arteries in patients with STEMI treated with high-intensity statin therapy. The present analysis included 44 patients (80 arteries) with serial measurements of hs-CRP. RESULTS At follow-up, median low-density lipoprotein cholesterol (LDL-C) levels decreased from 126 to 77 mg/dl, HDL-C increased from 44 to 47 mg/dl, and hs-CRP decreased from 1.6 to 0.7 mg/L. Regression of percent atheroma volume (-0.99%, 95% CI -1.84 to -0.14, p = 0.024) was accompanied by reduction of percent fibro-fatty (p = 0.04) and fibrous tissue (p < 0.001), and increase in percent necrotic core (p = 0.006) and dense calcium (p < 0.001). Follow-up levels of hs-CRP, but not LDL-C, correlated with changes in percent necrotic core (p = 0.001) and inversely with percent fibrous tissue volume (p = 0.008). Similarly, baseline-to-follow-up change of hs-CRP correlated with the change in percent necrotic core volume (p = 0.02). CONCLUSIONS In STEMI patients receiving high-intensity statin therapy, stabilization of VH-IVUS-defined necrotic core was confined to patients with lowest on-treatment levels and greatest reduction of hs-CRP. Elevated CRP levels at follow-up may identify progression of high-risk coronary plaque composition despite intensive statin therapy and overall regression of atheroma volume.
Resumo:
INTRODUCTION Monitoring breathing pattern is especially relevant in infants with lung disease. Recently, a vest-based inductive plethysmograph system (FloRight®) has been developed for tidal breathing measurement in infants. We investigated the accuracy of tidal breathing flow volume loop (TBFVL) measurements in healthy term-born infants and infants with lung disease by the vest-based system in comparison to an ultrasonic flowmeter (USFM) with a face mask. We also investigated whether the system discriminates between healthy infants and those with lung disease. METHODS Floright® measures changes in thoracoabdominal volume during tidal breathing through magnetic field changes generated by current-carrying conductor coils in an elastic vest. Simultaneous TBFVL measurements by the vest-based system and the USFM were performed at 44 weeks corrected postmenstrual age during quiet unsedated sleep. TBFVL parameters derived by both techniques and within both groups were compared. RESULTS We included 19 healthy infants and 18 infants with lung disease. Tidal volume per body weight derived by the vest-based system was significantly lower with a mean difference (95% CI) of -1.33 ml/kg (-1.73; -0.92), P < 0.001. Respiratory rate and ratio of time to peak tidal expiratory flow over total expiratory time (tPTEF/tE) did not differ between the two techniques. Both systems were able to discriminate between healthy infants and those with lung disease using tPTEF/tE. CONCLUSION FloRight® accurately measures time indices and may discriminate between healthy infants and those with lung disease, but demonstrates differences in tidal volume measurements. It may be better suited to monitor breathing pattern than for TBFVL measurements.
Resumo:
It has recently been reported in this journal that local fat depots produce a sizable frequency-dependent signal attenuation in magnetic resonance spectroscopy (MRS) of the brain. If of a general nature, this effect would question the use of internal reference signals for quantification of MRS and the quantitative use of MRS as a whole. Here, it was attempted to verify this effect and pinpoint the potential causes by acquiring data with various acquisition settings, including two field strengths, two MR scanners from different vendors, different water suppression sequences, RF coils, localization sequences, echo times, and lipid/metabolite phantoms. With all settings tested, the reported effect could not be reproduced, and it is concluded that water referencing and quantitative MRS per se remain valid tools under common acquisition conditions.
Resumo:
Purpose To investigate whether nonhemodynamic resonant saturation effects can be detected in patients with focal epilepsy by using a phase-cycled stimulus-induced rotary saturation (PC-SIRS) approach with spin-lock (SL) preparation and whether they colocalize with the seizure onset zone and surface interictal epileptiform discharges (IED). Materials and Methods The study was approved by the local ethics committee, and all subjects gave written informed consent. Eight patients with focal epilepsy undergoing presurgical surface and intracranial electroencephalography (EEG) underwent magnetic resonance (MR) imaging at 3 T with a whole-brain PC-SIRS imaging sequence with alternating SL-on and SL-off and two-dimensional echo-planar readout. The power of the SL radiofrequency pulse was set to 120 Hz to sensitize the sequence to high gamma oscillations present in epileptogenic tissue. Phase cycling was applied to capture distributed current orientations. Voxel-wise subtraction of SL-off from SL-on images enabled the separation of T2* effects from rotary saturation effects. The topography of PC-SIRS effects was compared with the seizure onset zone at intracranial EEG and with surface IED-related potentials. Bayesian statistics were used to test whether prior PC-SIRS information could improve IED source reconstruction. Results Nonhemodynamic resonant saturation effects ipsilateral to the seizure onset zone were detected in six of eight patients (concordance rate, 0.75; 95% confidence interval: 0.40, 0.94) by means of the PC-SIRS technique. They were concordant with IED surface negativity in seven of eight patients (0.88; 95% confidence interval: 0.51, 1.00). Including PC-SIRS as prior information improved the evidence of the standard EEG source models compared with the use of uninformed reconstructions (exceedance probability, 0.77 vs 0.12; Wilcoxon test of model evidence, P < .05). Nonhemodynamic resonant saturation effects resolved in patients with favorable postsurgical outcomes, but persisted in patients with postsurgical seizure recurrence. Conclusion Nonhemodynamic resonant saturation effects are detectable during interictal periods with the PC-SIRS approach in patients with epilepsy. The method may be useful for MR imaging-based detection of neuronal currents in a clinical environment. (©) RSNA, 2016 Online supplemental material is available for this article.