969 resultados para Radiation dose reduction


Relevância:

30.00% 30.00%

Publicador:

Resumo:

Objective - Evaluate preventable exposure dose in routine chest CT examinations beyond prescribed anatomical landmarks and estimate extra dose delivered to the patient. Background/rationale - Recent technical advances have greatly increased the clinical applications of CT; developments in multidetector-row CT (MDCT) technology have occurred; the major disadvantage with the increased use of MDCT is associated radiation exposure.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Naturally occurring radioactive materials (NORM) under certain conditions can reach hazardous radiological levels contributing to an additional exposure dose to ionizing radiation. Most environmental concerns are associated with uranium mining and milling sites, but the same concerns should be addressed to natural near surface occurrences of uranium as well as man-made sources such as technologically enhanced naturally occurring radioactive materials (TENORM) resulting from phosphates industry, ceramic industry and energy production activities, in particular from coal-fired power plants which is one of the major sources of increased exposure to man from enhanced naturally occurring materials. This work describes the methodology developed to assess the environmental radiation by in situ gamma spectrometry in the vicinity of a Portuguese coal fired power plant. The current investigation is part of a research project that is undergoing in the vicinity of Sines Coal-Fired Power Plant (south of Portugal) until the end of 2013.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Gamma radiations measurements were carried out in the vicinity of a coal-fired power plant located in the southwest coastline of Portugal. Two different gamma detectors were used to assess the environmental radiation within a circular area of 20 km centred in the coal plant: a scintillometer (SPP2 NF, Saphymo) and a high purity germanium detector (HPGe, Canberra). Fifty urban and suburban measurements locations were established within the defined area and two measurements campaigns were carried out. The results of the total gamma radiation ranged from 20.83 to 98.33 counts per second (c.p.s.) for both measurement campaigns and outdoor doses rates ranged from 77.65 to 366.51 Gy/h. Natural emitting nuclides from the U-238 and Th-232 decay series were identified as well as the natural emitting nuclide K-40. The radionuclide concentration from the uranium and thorium series determined by gamma spectrometry ranged from 0.93 to 73.68 Bq/kg, while for K-40 the concentration ranged from 84.14 to 904.38 Bq/kg. The obtained results were used primarily to define the variability in measured environmental radiation and to determine the coal plant’s influence in the measured radiation levels. The highest values were measured at two locations near the power plant and at locations between the distance of 6 and 20 km away from the stacks, mainly in the prevailing wind direction. The results showed an increase or at least an influence from the coal-fired plant operations, both qualitatively and quantitatively.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

A set of radiation measurements were carried out in several public and private institutions. These were selected with basis on the people affluence and passage to these sites. These measurements were registration formed either indoor, outdoor or underground and were compiled in three Case Studies. Radiation doses measurements were also made, surface and underground locations, and compiled in other two Case Studies. There were sampled, at the same time, humidity, temperature, atmospheric pressure and relevant construction materials at sampling locations. They were collected and registration formed to analyse if there is any relation or contribution for the measured value in each specific place. Geostatistical models were used to elaborate maps of the results both for radiation values and for doses. Preliminary relations were established among the measured parameters.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Decreased responses to hepatitis B vaccine have been associated with some host conditions including obesity. Susceptible non-responders to a primary three-dose vaccine series should be revaccinated. Those who maintain a non-responder condition after revaccination with three vaccine doses are unlikely to develop protection using more doses. This is a description of an obese woman who received six doses of hepatitis B vaccine and persisted as a non-responder. She was submitted to a vertical banded gastroplasty Roux-en-Y gastric bypass Capellas's technique. After weight reduction, she received three additional doses of vaccine and seroconverted. Further studies should help clarify the need to evaluate antibody levels and eventually revaccinate the increasing population of individuals who undergo weight reduction.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Doutor em Engenharia Biomédica

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Dissertação para obtenção do Grau de Mestre em Biotecnologia

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Forty-two with hepatosplenic patients treated with praziquantel and followed up for 5 years. One half of the patients received a single 30 mg/kg dose and the other half, two doses of 25 mg/kg given 4 hrs apart. According to Hoffman and Kato-Katz stool exams, an 83.3% cure rate, was observed after twelve months. Stool egg counts in cases of incomplete cure were greatly reduced. Liver function, as assessed by serum levels of aspartate aminotransferase, alanine aminotransferase, gamma glutamyltransferase and alkaline phosphatase activities as well as albumin and gamma globulin showed marked improvement after one year. Hepatomegaly was reduced in 81.0% of patients and splenomegaly in 78.8%. Spleen regression was complete in 15.1% of the total, and in 18.5% of those with compensated hepatosplenic disease. As a result of these observations, the authors recomend early treatment with anti-schistosomal medication, either oxamniquine or praziquantel, to halt progression of disease and reduce splenomegaly.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In August/1999, a group of 14 adults from the staff of a private hospital in Contagem -- Minas Gerais State, Brazil, received unintentionally a 25 times concentrated dose of the 17-DD yellow fever vaccine (Bio-Manguinhos), due to a mistake at the reconstitution step. All patients were clinically and laboratorially evaluated at days 5, 13 and 35 post vaccination. Frequency of side effects and clinical observations of this group of individuals were not different from the observed in recipients immunized with normal doses of the vaccine. At the second and third evaluation none of the subjects reported symptoms. None of the patients presented abnormalities at the physical examination at none of the time points and in all cases the blood examination was normal, except for a reduced number of platelets that was detected in one subject at the first and second evaluation and reverted to normal at third evaluation. At the first evaluation point, 8 subjects were serum negative and 6 serum positive for yellow fever at the plaque reduction neutralization test. In 5 subjects the observed titre was 10 times higher as the baseline of 2.36 Log10 mUI/ml. The samples collected at second and third evaluation (13th and 35th days) demonstrated that all subjects responded to the vaccination with the exception of one that did not present a positive result in any of the samples collected. This evaluation confirms the safety of the 17-DD yellow fever vaccine.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

In this thesis was investigated the radiation hardness of the building blocks of a future flexible X-ray sensor system. The characterized building blocks for the pixel addressing and signal amplification electronics are high mobility semiconducting oxide transistors (HMSO-TFTs) and organic transistors (OTFTs), whereas the photonic detection system is based on organic semiconducting single crystals (OSSCs). TFT parameters such as mobility, threshold voltage and subthreshold slope were measured as function of cumulative X-ray dose. Instead for OSSCs conductivity and X-ray sensitivity were analysed after various radiation steps. The results show that ionizing radiation does not lead to degradation in HMSO-TFTs. Instead OTFTs show instability in mobility which is reduced up to 73% for doses of 1 kGy. OSSC demonstrate stable detector properties for the tested total dose range. As conclusion, HMSO-TFTs and OSSCs can be readily employed in the X-ray detector system allowing operation for total doses exceeding 1 kGy of ionizing radiation.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

PURPOSE: The aim of this study was to evaluate the degree of metastatic bone pain palliation and medullar toxicity associated with samarium-153-EDTMP treatment. METHODS: Seventy-three patients with metastatic bone pain having previously undergone therapy with samarium-153-EDTMP (1 mCi/kg) were retrospectively evaluated. Routine follow-up included pain evaluation and blood counts for 2 months after treatment. Pain was evaluated using a subjective scale (from 0 to 10) before and for 8 weeks after the treatment. Blood counts were obtained before treatment and once a week for 2 months during follow-up. Dosimetry, based upon the urinary excretion of the isotope, was estimated in 41 individuals, and the resulting radiation absorbed doses were correlated with hematological data. RESULTS: Reduction in pain scores of 75% to 100% was obtained in 36 patients (49%), with a decrease of 50% to 75%, 25% to 50%, and 0% to 25% in, respectively, 20 (27%), 10 (14%), and 7 (10%) patients. There was no significant relationship between the pain response and location of the primary tumor (breast or prostate cancer). Mild to moderate myelosuppression was noted in 75.3% of patients, usually with hematological recovery at 8 weeks. The mean bone marrow dose was 347 ± 65 cGy, and only a weak correlation was found between absorbed dose and myelosuppression (Pearson coefficient = .4). CONCLUSIONS: Samarium-153-EDTMP is a valuable method for metastatic bone pain palliation. A mild to moderate and transitory myelosuppression is the main toxicity observed after samarium therapy, showing a weak correlation with dosimetric measures.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Background:Statins have proven efficacy in the reduction of cardiovascular events, but the financial impact of its widespread use can be substantial.Objective:To conduct a cost-effectiveness analysis of three statin dosing schemes in the Brazilian Unified National Health System (SUS) perspective.Methods:We developed a Markov model to evaluate the incremental cost-effectiveness ratios (ICERs) of low, intermediate and high intensity dose regimens in secondary and four primary scenarios (5%, 10%, 15% and 20% ten-year risk) of prevention of cardiovascular events. Regimens with expected low-density lipoprotein cholesterol reduction below 30% (e.g. simvastatin 10mg) were considered as low dose; between 30-40%, (atorvastatin 10mg, simvastatin 40mg), intermediate dose; and above 40% (atorvastatin 20-80mg, rosuvastatin 20mg), high-dose statins. Effectiveness data were obtained from a systematic review with 136,000 patients. National data were used to estimate utilities and costs (expressed as International Dollars - Int$). A willingness-to-pay (WTP) threshold equal to the Brazilian gross domestic product per capita (circa Int$11,770) was applied.Results:Low dose was dominated by extension in the primary prevention scenarios. In the five scenarios, the ICER of intermediate dose was below Int$10,000 per QALY. The ICER of the high versus intermediate dose comparison was above Int$27,000 per QALY in all scenarios. In the cost-effectiveness acceptability curves, intermediate dose had a probability above 50% of being cost-effective with ICERs between Int$ 9,000-20,000 per QALY in all scenarios.Conclusions:Considering a reasonable WTP threshold, intermediate dose statin therapy is economically attractive, and should be a priority intervention in prevention of cardiovascular events in Brazil.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

AbstractBackground:Prone imaging has been demonstrated to minimize diaphragmatic and breast tissue attenuation.Objectives:To determine the role of prone imaging on the reduction of unnecessary rest perfusion studies and coronary angiographies performed, thus decreasing investigation time and radiation exposure.Methods:We examined 139 patients, 120 with an inferior wall and 19 with an anterior wall perfusion defect that might represented attenuation artifact. Post-stress images were acquired in both the supine and prone position. Coronary angiography was used as the “gold standard” for evaluating coronary artery patency. The study was terminated and rest imaging was obviated in the presence of complete improvement of the defect in the prone position. Quantitative interpretation was performed. Results were compared with clinical data and coronary angiographic findings.Results:Prone acquisition correctly revealed defect improvement in 89 patients (89/120) with inferior wall and 12 patients (12/19) with anterior wall attenuation artifact. Quantitative analysis demonstrated statistically significant difference in the mean summed stress scores (SSS) of supine and mean SSS of prone studies in patients with disappearing inferior wall defect in the prone position and patent right coronary artery (true negative results). The mean difference between SSS in supine and in prone position was higher with disappearing than with remaining defects.Conclusion:Technetium-99m (Tc-99m) tetrofosmin myocardial perfusion imaging with the patient in the prone position overcomes soft tissue attenuation; moreover it provides an inexpensive, accurate approach to limit the number of unnecessary rest perfusion studies and coronary angiographies performed.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

Abstract Background: The effect of statins on the endothelial function in humans remains under discussion. Particularly, it is still unclear if the improvement in endothelial function is due to a reduction in LDL-cholesterol or to an arterial pleiotropic effect. Objective: To test the hypothesis that modulation of the endothelial function promoted by statins is primarily mediated by the degree of reduction in LDL-cholesterol, independent of the dose of statin administered. Methods: Randomized clinical trial with two groups of lipid-lowering treatment (16 patients/each) and one placebo group (14 patients). The two active groups were designed to promote a similar degree of reduction in LDL-cholesterol: the first used statin at a high dose (80 mg, simvastatin 80 group) and the second used statin at a low dose (10 mg) associated with ezetimibe (10 mg, simvastatin 10/ezetimibe group) to optimize the hypolipidemic effect. The endothelial function was assessed by flow-mediated vasodilation (FMV) before and 8 weeks after treatment. Results: The decrease in LDL-cholesterol was similar between the groups simvastatin 80 and simvastatin 10/ezetimibe (27% ± 31% and 30% ± 29%, respectively, p = 0.75). The simvastatin 80 group presented an increase in FMV from 8.4% ± 4.3% at baseline to 11% ± 4.2% after 8 weeks (p = 0.02). Similarly, the group simvastatin 10/ezetimibe showed improvement in FMV from 7.3% ± 3.9% to 12% ± 4.4% (p = 0.001). The placebo group showed no variation in LDL-cholesterol level or endothelial function. Conclusion: The improvement in endothelial function with statin seems to depend more on a reduction in LDL-cholesterol levels, independent of the dose of statin administered, than on pleiotropic mechanisms.

Relevância:

30.00% 30.00%

Publicador:

Resumo:

This report belongs to the series of works carried out Oswaldo Cruz Ins¬titute, on the treatment of treponematosis with penicillin. The present report deals with investigations performed in order to ascer¬tain the following points: 1) the mininal curative dosis for the initial lesions of yaws; 2) the effect of reduction of the number of injections each day, to verifie the possibility of application of penicillin in the prophylaxis of yaws in rural zones; 3) reduction of the time of treatment by application of high dosis. 1) With dosis of 150 and 100 Oxford units each four hours, clinical reco¬very was obtained after 17 days of treatment. With 50 O.u. during 40 days clinical recovery was not obtained. 2) a) With 3 injections of 400 O.u. each day (6,12 and 18 hoórs clocks) clinical recovery was obtained after 14 to 16 days; b) with 2 injections of 400 O.u. each day (6 and 18 hoors clocks), clinical recovery was obtained after 16 to 23 days; c) with 1 injection of 1.600 and 3.200 each day, clinical recovery was obtained after 30 and 20 days. 3) With dosis of 33.3 and 46.7 O.u. by each kilo of weight each four hours, during 15 days, clinical recovery was obtained more or less in 25 days. The same result was obtained with the dosis of 61.5 and 166.7 O.u. by each kilo of weight, each four hours, during 4 days. But with 100.000 O.u. in fine dosis of 20.000 in a day ou by, clinical recovery was not obtained.