992 resultados para Radiation Protection.
Resumo:
A set of radiation measurements were carried out in several public and private institutions. These were selected with basis on the people affluence and passage to these sites. These measurements were registration formed either indoor, outdoor or underground and were compiled in three Case Studies. Radiation doses measurements were also made, surface and underground locations, and compiled in other two Case Studies. There were sampled, at the same time, humidity, temperature, atmospheric pressure and relevant construction materials at sampling locations. They were collected and registration formed to analyse if there is any relation or contribution for the measured value in each specific place. Geostatistical models were used to elaborate maps of the results both for radiation values and for doses. Preliminary relations were established among the measured parameters.
Resumo:
In the past few years, induction of protective immunity to cutaneous leishmaniasis has been attempted by many researchers using a variety of antigenic preparations, such as living promastigotes or promastigote extracts, partially purified, or defined proteins. In this study, eleven proteins from Leishmania (Leishmania) amazonensis (LLa) with estimated molecular mass ranging from 97 to 13.5kDa were isolated by polyacrylamide gel electrophoresis and electro-elution. The proteins were associated as vaccine in different preparations with gp63 and BCG (Bacilli Calmette-Guérin). The antigenicity of these vaccines was measured by their ability to induce the production of IFN-g by lymphocyte from subjects vaccinated with Leishvacinâ . The immunogenicity was evaluated in vaccinated mice. C57BL/10 mice were vaccinated with three doses of each vaccine consisting of 30 mg of each protein at 15 days interval. One hundred mg of live BCG was only used in the first dose. Seven days after the last dose, they received a first challenge infection with 105 infective promastigotes and four months later, a second challenge was done. Two months after the second challenge, 42.86% of protection was obtained in the group of mice vaccinated with association of proteins of gp63+46+22kDa, gp63+13.5+25+42kDa, gp63+46+42kDa, gp63+66kDa, and gp63+97kDa; 57.14% of protection was demonstrated with gp63+46+97+13.5kDa, gp63+46+97kDa, gp63+46+33kDa, and 71.43% protection for gp63 plus all proteins. The vaccine of gp63+46+40kDa that did not protect the mice, despite the good specific stimulation of lymphocytes (LSI = 7.60) and 10.77UI/ml of IFN-g production. When crude extract of L. (L.) amazonensis was used with BCG a 57.14% of protection was found after the first challenge and 28.57% after the second, the same result was observed for gp63. The data obtained with the vaccines can suggest that the future vaccine probably have to contain, except the 40kDa, a cocktail of proteins that would protect mice against cutaneous leishmaniasis.
Resumo:
RESUMO - Na radiologia de intervenção, e concretamente em ortopedia, os raios X são intensamente utilizados permitindo a visualização de diversas técnicas de intervenção cirúrgica. Do ponto de vista médico as vantagens dessa prática são enormes, contudo, os profissionais de saúde envolvidos são susceptíveis de estarem expostos a valores de dose de radiação que significam a sua classificação como trabalhadores expostos. O presente estudo realizou-se num hospital e teve como objectivo obter uma estimativa das doses envolvidas em ortopedia de intervenção, utilizando várias metodologias experimentais para caracterização do campo de radiação primário e secundário. Observaram-se distintos níveis de dose de acordo com a zona anatómica exposta à radiação X: (i) gónadas — 0,02 a 3 mGy/h; (ii) cristalino — 0,06 a 1 mGy/h e (iii) mãos — 0,6 mGy/h. Tais resultados evidenciam uma clara necessidade de utilização de equipamentos de protecção e de vigilância dosimétrica pelos profissionais de saúde envolvidos no acto cirúrgico.--------------------------ABSTRACT - In intervention radiology, and more specifically in orthopaedics, X-rays are intensely used allowing the visualization of many acts of clinical intervention. From a clinical perspective, the advantages of that practice are significant; however, involved health care professionals are susceptible of being exposed to radiation dose values that mean their classification as exposed workers. The present study, performed in a hospital, aimed to obtain an estimation of the doses involved in intervention orthopaedics through several experimental methodologies in order to characterise the primary and the secondary radiation fields. Different levels of dose were observed according to the anatomic area exposed to X radiation: (i) gonads — 0.02 a 3 mGy/h; (ii) crystalline lens — 0.06 a 1 mGy/h e (iii) hands – 0.6 mGy/h. Such results denote a clear need of protection equipment use and of dosimetric surveillance by the health