1000 resultados para RESONANCE INTEGRAL
Resumo:
AIMS: This study was performed to compare the sensitivity of ultrasonography, computerized tomography during arterial portography, delayed computerized tomography, and magnetic resonance imaging to detect focal liver lesions. Forty three patients with primary or secondary malignant liver lesions were studied prior to surgical intervention. METHODS: The results of the imaging studies were compared with intraoperative examination of the liver, intraoperative ultrasonography and pathology results (29 patients). In the non-operated (14 patients) group, we compared the number of lesions detected by each technique. RESULTS: One hundred and forty six lesions were detected. There was 84% sensitivity with computerized tomography during arterial portography, 61.3% with delayed scan, 63.3% with magnetic resonance imaging and 51% with ultrasonography in operated patients. In patients who did not undergo surgery, magnetic resonance imaging was more sensitive in detecting lesions. CONCLUSIONS: In operated and non-operated patients series, CT during arterial portography had the highest sensitivity, but magnetic resonance imaging had the most consistent overall results.
Resumo:
Despite obvious improvements in spectral resolution at high magnetic field, the detection of 13C labeling by 1H-[13C] NMR spectroscopy remains hampered by spectral overlap, such as in the spectral region of 1H resonances bound to C3 of glutamate (Glu) and glutamine (Gln), and C6 of N-acetylaspartate (NAA). The aim of this study was to develop, implement, and apply a novel 1H-[13C] NMR spectroscopic editing scheme, dubbed "selective Resonance suppression by Adiabatic Carbon Editing and Decoupling single-voxel STimulated Echo Acquisition Mode" (RACED-STEAM). The sequence is based on the application of two asymmetric narrow-transition-band adiabatic RF inversion pulses at the resonance frequency of the 13C coupled to the protons that need to be suppressed during the mixing time (TM) period, alternating the inversion band downfield and upfield from the 13C resonance on odd and even scans, respectively, thus suppressing the detection of 1H resonances bound to 13C within the transition band of the inversion pulse. The results demonstrate the efficient suppression of 1H resonances bound to C3 of Glu and Gln, and C4 of Glu, which allows the 1H resonances bound to C6 of NAA and C4 of Gln to be revealed. The measured time course of the resolved labeling into NAA C6 with the new scheme was consistent with the slow turnover of NAA.
Resumo:
L'any 2011 la malaltia d'Alzheimer es situava com la quarta causa de mort més freqüent amb un augment de fins a 11.907, més del doble de morts que l'any 2000 (INE). Aquestes dades demostren l'augment del número de persones que pateixen una demència a mesura que envelleixen i una de les explicacions és l'augment de l'esperança de vida. Per aquest motiu l'estudi de la qualitat de vida ha adquirit una gran importància des de la dècada dels 90. La qualitat de vida és un concepte especialment subjectiu pel fet que cada persona la viu segons la pròpia percepció de salut i benestar i el grau d'adaptació a l'entorn que l'envolta. Per aquest motiu es planteja un programa de psicoestimulació integral (PPI) centrat en les individualitats de cada persona: valors, interessos, història ocupacional..., des de la filosofia de la Teràpia Ocupacional. El projecte està elaborat mitjançant la metodologia qualitativa utilitzant l'enquesta en profunditat semi-estructurada per a realitzar les entrevistes i obtenir la informació principal a l'inici i al final del programa juntament amb tota la informació que s'obtingui de l'observació participant del dia a dia de cada un dels professionals per tal d'estudiar fins a quin punt aquesta atenció centrada en la persona contribueix a millorar la qualitat de vida de les persones afectades de Malaltia d'Alzheimer que reben tractaments no farmacològics com el proposat en aquest projecte. Com a tot estudi es poden trobar alguns factors condicionants com pot ser l'evolució pròpia de la malaltia amb les conseqüències negatives que això comporta i/o el número de participants que formen la mostra.
Resumo:
Normal and abnormal brains can be segmented by registering the target image with an atlas. Here, an atlas is defined as the combination of an intensity image (template) and its segmented image (the atlas labels). After registering the atlas template and the target image, the atlas labels are propagated to the target image. We define this process as atlas-based segmentation. In recent years, researchers have investigated registration algorithms to match atlases to query subjects and also strategies for atlas construction. In this paper we present a review of the automated approaches for atlas-based segmentation of magnetic resonance brain images. We aim to point out the strengths and weaknesses of atlas-based methods and suggest new research directions. We use two different criteria to present the methods. First, we refer to the algorithms according to their atlas-based strategy: label propagation, multi-atlas methods, and probabilistic techniques. Subsequently, we classify the methods according to their medical target: the brain and its internal structures, tissue segmentation in healthy subjects, tissue segmentation in fetus, neonates and elderly subjects, and segmentation of damaged brains. A quantitative comparison of the results reported in the literature is also presented.
Resumo:
BACKGROUND: Accurate staging is essential to determine the correct management of patients diagnosed with prostate cancer. We assess the accuracy of 3T multiparametric magnetic resonance imaging (MRI) with endorectal coil (3TemMRI) in detecting prostate cancer local extension. METHODS: We retrospectively reviewed charts from January 2008 to July 2012 from all patients undergoing radical prostatectomy. Patients were only included if 3TemMRI and radical prostatectomy were performed at our institution. Based on the presence of extracapsular extension (ECE) at 3TemMRI, prostate cancer was dichotomized into locally advanced or organ-confined disease. The accuracy of 3TemMRI local staging was then evaluated using definitive pathology as a reference. RESULTS: Overall, 177 radical prostatectomies were performed within the timeframe. After applying exclusion criteria, 60 patients were included in the final analysis. The mean patient age was 67 ± 7 (standard deviation) years. Mean prostate-specific antigen value was 12.7 ± 12.7 ng/L. Based on preoperative characteristics, we considered 38 of the 60 patients (63%) patients high risk. 3TemMRI identified an organ-confined tumour in 46 patients and locally advanced disease in 14 patients. When correlated to final pathology, 3TemMRI specificity, sensitivity, negative and positive predictive values, and accuracy in detecting locally advanced prostate cancer were 90%, 35%, 57%, 79% and 62%, respectively. INTERPRETATION: This study shows that the use of preoperative 3TemMRI can be used to identify organ-confined prostate cancer when locally advanced disease is suspected.
Resumo:
BACKGROUND: This study validates the use of phycoerythrin (PE) and allophycocyanin (APC) for fluorescence energy transfer (FRET) analyzed by flow cytometry. METHODS: FRET was detected when a pair of antibody conjugates directed against two noncompetitive epitopes on the same CD8alpha chain was used. FRET was also detected between antibody conjugate pairs specific for the two chains of the heterodimeric alpha (4)beta(1) integrin. Similarly, the association of T-cell receptor (TCR) with a soluble antigen ligand was detected by FRET when anti-TCR antibody and MHC class I/peptide complexes (<<tetramers>>) were used. RESULTS: FRET efficiency was always less than 10%, probably because of steric effects associated with the size and structure of PE and APC. Some suggestions are given to take into account this and other effects (e.g., donor and acceptor concentrations) for a better interpretation of FRET results obtained with this pair of fluorochromes. CONCLUSIONS: We conclude that FRET assays can be carried out easily with commercially available antibodies and flow cytometers to study arrays of multimolecular complexes.
Resumo:
Alterations to brain homeostasis during development are reflected in the neurochemical profile determined noninvasively by (1)H magnetic resonance spectroscopy. We determined longitudinal biochemical modifications in the cortex, hippocampus, and striatum of C57BL/6 mice aged between 3 and 24 months . The regional neurochemical profile evolution indicated that aging induces general modifications of neurotransmission processes (reduced GABA and glutamate), primary energy metabolism (altered glucose, alanine, and lactate) and turnover of lipid membranes (modification of choline-containing compounds and phosphorylethanolamine), which are all probably involved in the frequently observed age-related cognitive decline. Interestingly, the neurochemical profile was different in male and female mice, particularly in the levels of taurine that may be under the control of estrogen receptors. These neurochemical profiles constitute the basal concentrations in cortex, hippocampus, and striatum of healthy aging male and female mice.
Resumo:
L'objectiu del projecte és implementar una solució integral de gestió d'impressió que proporcioni a l'empresa LaRoba un perfecte control sobre els dispositius i un estalvi substancial en els costos globals derivats de la impressió de documents.
Resumo:
Postprint (published version)
Resumo:
More and more, integral abutment bridges are being used in place of the more traditional bridge designs with expansion releases. In this study, states which use integral abutment bridges were surveyed to determine their current practice in the design of these structures. To study piles in integral abutment bridges, a finite element program for the soil-pile system was developed (1) with materially and geometrically nonlinear, two and three dimensional beam elements and (2) with a nonlinear, Winkler soil model with vertical, horizontal, and pile tip springs. The model was verified by comparison to several analytical and experimental examples. A simplified design model for analyzing piles in integral abutment bridges is also presented. This model grew from previous analytical models and observations of pile behavior. The design model correctly describes the essential behavioral characteristics of the pile and conservatively predicts the vertical load-carrying capacity. Analytical examples are presented to illustrate the effects of lateral displacements on the ultimate load capacity of a pile. These examples include friction and end-bearing piles; steel, concrete, and timber piles; and bending about the weak, strong, and 45° axes for H piles. The effects of cyclic loading are shown for skewed and nonskewed bridges. The results show that the capacity of friction piles is not significantly affected by lateral displacements, but the capacity of end-bearing piles is reduced. Further results show that the longitudinal expansion of the bridge can introduce a vertical preload on the pile.
Resumo:
Addendum to HR-273
Resumo:
While 3D thin-slab coronary magnetic resonance angiography (MRA) has traditionally been performed using a Cartesian acquisition scheme, spiral k-space data acquisition offers several potential advantages. However, these strategies have not been directly compared in the same subjects using similar methodologies. Thus, in the present study a comparison was made between 3D coronary MRA using Cartesian segmented k-space gradient-echo and spiral k-space data acquisition schemes. In both approaches the same spatial resolution was used and data were acquired during free breathing using navigator gating and prospective slice tracking. Magnetization preparation (T(2) preparation and fat suppression) was applied to increase the contrast. For spiral imaging two different examinations were performed, using one or two spiral interleaves, during each R-R interval. Spiral acquisitions were found to be superior to the Cartesian scheme with respect to the signal-to-noise ratio (SNR) and contrast-to-noise-ratio (CNR) (both P < 0.001) and image quality. The single spiral per R-R interval acquisition had the same total scan duration as the Cartesian acquisition, but the single spiral had the best image quality and a 2.6-fold increase in SNR. The double-interleaf spiral approach showed a 50% reduction in scanning time, a 1.8-fold increase in SNR, and similar image quality when compared to the standard Cartesian approach. Spiral 3D coronary MRA appears to be preferable to the Cartesian scheme. The increase in SNR may be "traded" for either shorter scanning times using multiple consecutive spiral interleaves, or for enhanced spatial resolution.
Resumo:
We show that the dipole, a system usually proposed to model relaxation phenomena, exhibits a maximum in the signal-to-noise ratio at a nonzero noise level, thus indicating the appearance of stochastic resonance. The phenomenon occurs in two different situations, i.e., when the minimum of the potential of the dipole remains fixed in time and when it switches periodically between two equilibrium points. We have also found that the signal-to-noise ratio has a maximum for a certain value of the amplitude of the oscillating field.
Resumo:
PURPOSE: To compare volume-targeted and whole-heart coronary magnetic resonance angiography (MRA) after the administration of an intravascular contrast agent. MATERIALS AND METHODS: Six healthy adult subjects underwent a navigator-gated and -corrected (NAV) free breathing volume-targeted cardiac-triggered inversion recovery (IR) 3D steady-state free precession (SSFP) coronary MRA sequence (t-CMRA) (spatial resolution = 1 x 1 x 3 mm(3)) and high spatial resolution IR 3D SSFP whole-heart coronary MRA (WH-CMRA) (spatial resolution = 1 x 1 x 2 mm(3)) after the administration of an intravascular contrast agent B-22956. Subjective and objective image quality parameters including maximal visible vessel length, vessel sharpness, and visibility of coronary side branches were evaluated for both t-CMRA and WH-CMRA. RESULTS: No significant differences (P = NS) in image quality were observed between contrast-enhanced t-CMRA and WH-CMRA. However, using an intravascular contrast agent, significantly longer vessel segments were measured on WH-CMRA vs. t-CMRA (right coronary artery [RCA] 13.5 +/- 0.7 cm vs. 12.5 +/- 0.2 cm; P < 0.05; and left circumflex coronary artery [LCX] 11.9 +/- 2.2 cm vs. 6.9 +/- 2.4 cm; P < 0.05). Significantly more side branches (13.3 +/- 1.2 vs. 8.7 +/- 1.2; P < 0.05) were visible for the left anterior descending coronary artery (LAD) on WH-CMRA vs. t-CMRA. Scanning time and navigator efficiency were similar for both techniques (t-CMRA: 6.05 min; 49% vs. WH-CMRA: 5.51 min; 54%, both P = NS). CONCLUSION: Both WH-CMRA and t-CMRA using SSFP are useful techniques for coronary MRA after the injection of an intravascular blood-pool agent. However, the vessel conspicuity for high spatial resolution WH-CMRA is not inferior to t-CMRA, while visible vessel length and the number of visible smaller-diameter vessels and side-branches are improved.