903 resultados para Projection spectrograph


Relevância:

10.00% 10.00%

Publicador:

Resumo:

We present an analysis of the M-O chemical bonding in the binary oxides MgO, CaO, SrO, BaO, and Al2O3 based on ab initio wave functions. The model used to represent the local environment of a metal cation in the bulk oxide is an MO6 cluster which also includes the effect of the lattice Madelung potential. The analysis of the wave functions for these clusters leads to the conclusion that all the alkaline-earth oxides must be regarded as highly ionic oxides; however, the ionic character of the oxides decreases as one goes from MgO, almost perfectly ionic, to BaO. In Al2O3 the ionic character is further reduced; however, even in this case, the departure from the ideal, fully ionic, model of Al3+ is not exceptionally large. These conclusions are based on three measures, a decomposition of the Mq+-Oq- interaction energy, the number of electrons associated to the oxygen ions as obtained from a projection operator technique, and the analysis of the cation core-level binding energies. The increasing covalent character along the series MgO, CaO, SrO, and BaO is discussed in view of the existing theoretical models and experimental data.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Messages à retenir: La scanographie hélicoïdale à collimation fine sur l'ensemble du thorax est l'examen de référence pour le diagnostic et l'évaluation de la distributiontopographique et de l'étendue des bronchectasies.Les reformations multiplanaires et les techniques de projection d'intensité maximum et minimum améliorent les performances diagnostiques et permettent unemeilleure détection des lésions associées des petites voies aériennes (bronchiolite infectieuse, bronchiolite oblitérative).Chez les patients atteints de bronchectasies, le degré d'épaississement pariétal bronchique ainsi que l'étendue des zones hypodenses hypoperfusées traduisantdes lésions d'obstruction bronchiolaire sont parfaitement corrélés à la sévérité du retentissement fonctionnel de la maladie .La scanographie est peu fiable pour reconnaître le diagnostic étiologique des bronchectasies. Résumé: La scanographie hélicoïdale multidétecteur à collimation fine sur l'ensemble du thorax au cours d'une seule et même apnée inspiratoire est supérieure auxexamens en coupes fines incrémentales haute résolution avec un intervalle de coupes de 10 mm, pour le diagnostic et l'évaluation de l'étendue desbronchectasies. L'usage des reformations multiplanaires améliore la détection des bronchectasies, augmente la reproductibilité des radiologues pour lediagnostic des bronchectasies ainsi que leur niveau de confiance pour apprécier la distribution lésionnelle . L'examen scanographique évalue le nombre et ladistribution des impactions mucoïdes dans des bronches dilatées et le retentissement de l'atteinte bronchique sur les voies aériennes distales et le parenchymepulmonaire. La recherche d'atteinte associée des petites voies aériennes est systématique : détection des foyers de bronchiolite infectieuse et évaluation de l'étendue des zones hypodenses, hypoperfusées, avec piégeage, qui reflètent les lésions de bronchiolite oblitérative . Ces dernières sont corrélées au degré desévérité de l'obstruction fonctionnelle. La scanographie reste peu fiable pour le diagnostic étiologique des bronchectasies. Inversement, certains mécanismessont facilement identifiés, tels que les bronchectasies post-obstructives et les bronchectasies par traction des fibroses pulmonaires .

Relevância:

10.00% 10.00%

Publicador:

Resumo:

OBJECTIVE: The purpose of this article is to assess the effect of the adaptive statistical iterative reconstruction (ASIR) technique on image quality in hip MDCT arthrography and to evaluate its potential for reducing radiation dose. SUBJECTS AND METHODS: Thirty-seven patients examined with hip MDCT arthrography were prospectively randomized into three different protocols: one with a regular dose (volume CT dose index [CTDIvol], 38.4 mGy) and two with a reduced dose (CTDIvol, 24.6 or 15.4 mGy). Images were reconstructed using filtered back projection (FBP) and four increasing percentages of ASIR (30%, 50%, 70%, and 90%). Image noise and contrast-to-noise ratio (CNR) were measured. Two musculoskeletal radiologists independently evaluated several anatomic structures and image quality parameters using a 4-point scale. They also jointly assessed acetabular labrum tears and articular cartilage lesions. RESULTS: With decreasing radiation dose level, image noise statistically significantly increased (p=0.0009) and CNR statistically significantly decreased (p=0.001). We also found a statistically significant reduction in noise (p=0.0001) and increase in CNR (p≤0.003) with increasing percentage of ASIR; in addition, we noted statistically significant increases in image quality scores for the labrum and cartilage, subchondral bone, overall diagnostic quality (up to 50% ASIR), and subjective noise (p≤0.04), and statistically significant reductions for the trabecular bone and muscles (p≤0.03). Regardless of the radiation dose level, there were no statistically significant differences in the detection and characterization of labral tears (n=24; p=1) and cartilage lesions (n=40; p≥0.89) depending on the ASIR percentage. CONCLUSION: The use of up to 50% ASIR in hip MDCT arthrography helps to reduce radiation dose by approximately 35-60%, while maintaining diagnostic image quality comparable to that of a regular-dose protocol using FBP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: At 7 Tesla (T), conventional static field (B0 ) projection mapping techniques, e.g., FASTMAP, FASTESTMAP, lead to elevated specific absorption rates (SAR), requiring longer total acquisition times (TA). In this work, the series of adiabatic pulses needed for slab selection in FASTMAP is replaced by a single two-dimensional radiofrequency (2D-RF) pulse to minimize TA while ensuring equal shimming performance. METHODS: Spiral gradients and 2D-RF pulses were designed to excite thin slabs in the small tip angle regime. The corresponding selection profile was characterized in phantoms and in vivo. After optimization of the shimming protocol, the spectral linewidths obtained after 2D localized shimming were compared with conventional techniques and published values from (Emir et al NMR Biomed 2012;25:152-160) in six different brain regions. RESULTS: Results on healthy volunteers show no significant difference (P > 0.5) between the spectroscopic linewidths obtained with the adiabatic (TA = 4 min) and the new low-SAR and time-efficient FASTMAP sequence (TA = 42 s). The SAR can be reduced by three orders of magnitude and TA accelerated six times without impact on the shimming performances or quality of the resulting spectra. CONCLUSION: Multidimensional pulses can be used to minimize the RF energy and time spent for automated shimming using projection mapping at high field. Magn Reson Med, 2014. © 2014 Wiley Periodicals, Inc.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

L'article examine, à travers un grand nombre d'exemples principalement issus du cinéma hollywoodien contemporain, les implications esthétiques et narratologiques de ce « paradoxe » qui consiste à vouloir filmer l'écrivain et son travail. L'analyse de films présentant diverses formes de mise en abyme - l'écrivain y est souvent visualisé sous la forme d'une projection dans l'oeuvre qu'il écrit - permet à l'auteur de montrer comment les films tendent à développer sur le plan scénaristique des stratégies visant à compenser le déficit en termes de spectaculaire et d'action qu'implique la monstration de la matérialité de l'écrit. Il est ainsi question de la manière dont certains films exacerbent la dimension orale du verbal, optent pour des motifs tels que la panne d'inspiration de l'écrivain, associent l'écrit à un personnage qui le met en actes ou transforment le contenu de l'oeuvre d'un auteur en un monde.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

La projection utilise toujours le programme de simulation SIMULIT, dans sa treizième version. (...) Seule l'évolution démographique a été considérée dans les projections du nombre de lits: aucune des autres variables susceptibles de changer dans le futur n'a été prise en compte, ni celle en relation avec l'activité hospitalière elle-même (modification des taux d'hospitalisation, des durées de séjour, etc.), ni celles concernant l'état de santé de la population (modification de l'incidence ou de la prévalence des maladies). En d'autres termes, cette projection montre l'effet de l'évolution démographique sur l'activité hospitalière, si les caractéristiques de cette activité devaient rester celles observées dans les années 80. Il ne s'agit donc pas d'une prévision. [Auteurs, p. 1]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

In its 2007 Session, the Iowa General Assembly passed, and Governor Culver signed into law, extensive and far-reaching state energy policy legislation. This legislation created the Iowa Office of Energy Independence and the Iowa Power Fund. It also required a report to be issued each year detailing: • The historical use and distribution of energy in Iowa. • The growth rate of energy consumption in Iowa, including rates of growth for each energy source. • A projection of Iowa’s energy needs through the year 2025 at a minimum. • The impact of meeting Iowa’s energy needs on the economy of the state, including the impact of energy production and use on greenhouse gas emissions. • An evaluation of renewable energy sources, including the current and future technological potential for such sources. Much of the energy information for this report has been derived from the on-line resources of the Energy Information Administration (EIA) of the United States Department of Energy (USDOE). The EIA provides policy-independent data, forecasts and analyses on energy production, stored supplies, consumption and prices. For complete, economy-wide information, the most recent data available is for the year 2008. For some energy sectors, more current data is available from EIA and other sources and, when available, such information has been included in this report.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

PURPOSE: To compare 3 different flow targeted magnetization preparation strategies for coronary MR angiography (cMRA), which allow selective visualization of the vessel lumen. MATERIAL AND METHODS: The right coronary artery of 10 healthy subjects was investigated on a 1.5 Tesla MR system (Gyroscan ACS-NT, Philips Healthcare, Best, NL). A navigator-gated and ECG-triggered 3D radial steady-state free-precession (SSFP) cMRA sequence with 3 different magnetization preparation schemes was performed referred to as projection SSFP (selective labeling of the aorta, subtraction of 2 data sets), LoReIn SSFP (double-inversion preparation, selective labeling of the aorta, 1 data set), and inflow SSFP (inversion preparation, selective labeling of the coronary artery, 1 data set). Signal-to-noise ratio (SNR) of the coronary artery and aorta, contrast-to-noise ratio (CNR) between the coronary artery and epicardial fat, vessel length and vessel sharpness were analyzed. RESULTS: All cMRA sequences were successfully obtained in all subjects. Both projection SSFP and LoReIn SSFP allowed for selective visualization of the coronary arteries with excellent background suppression. Scan time was doubled in projection SSFP because of the need for subtraction of 2 data sets. In inflow SSFP, background suppression was limited to the tissue included in the inversion volume. Projection SSFP (SNR(coro): 25.6 +/- 12.1; SNR(ao): 26.1 +/- 16.8; CNR(coro-fat): 22.0 +/- 11.7) and inflow SSFP (SNR(coro): 27.9 +/- 5.4; SNR(ao): 37.4 +/- 9.2; CNR(coro-fat): 24.9 +/- 4.8) yielded significantly increased SNR and CNR compared with LoReIn SSFP (SNR(coro): 12.3 +/- 5.4; SNR(ao): 11.8 +/- 5.8; CNR(coro-fat): 9.8 +/- 5.5; P < 0.05 for both). Longest visible vessel length was found with projection SSFP (79.5 mm +/- 18.9; P < 0.05 vs. LoReIn) whereas vessel sharpness was best in inflow SSFP (68.2% +/- 4.5%; P < 0.05 vs. LoReIn). Consistently good image quality was achieved using inflow SSFP likely because of the simple planning procedure and short scanning time. CONCLUSION: Three flow targeted cMRA approaches are presented, which provide selective visualization of the coronary vessel lumen and in addition blood flow information without the need of contrast agent administration. Inflow SSFP yielded highest SNR, CNR and vessel sharpness and may prove useful as a fast and efficient approach for assessing proximal and mid vessel coronary blood flow, whereas requiring less planning skills than projection SSFP or LoReIn SSFP.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Il faut insister sur le sens et les limites des résultats présentés ici. Seule l'évolution démographique a été considérée dans les projections du nombre de lits: aucune des autres variables susceptibles de changer dans le futur n'a été prise en compte, ni celles en relation avec l'activité hospitalière elle-même (modification des taux d'hospitalisation, des durées de séjour, etc.), ni celles concernant l'état de santé de la population (modification de l'incidence ou de la prévalence des maladies). En d'autres termes, cette projection montre l'effet de l'évolution démographique sur l'activité hospitalière, si les caractéristiques de cette activité devaient rester celles observées dans les années 80. Il ne s'agit donc pas d'une prévision. Le nombre de lits projetés constitue une sorte de référence, qui peut faciliter l'élaboration de scénarios sanitaires, ceux par exemple destinés à modifier l'effectif des lits hospitaliers. [Auteurs, p. 1]

Relevância:

10.00% 10.00%

Publicador:

Resumo:

INTRODUCTION: Adaptive statistical iterative reconstruction (ASIR) can decrease image noise, thereby generating CT images of comparable diagnostic quality with less radiation. The purpose of this study is to quantify the effect of systematic use of ASIR versus filtered back projection (FBP) for neuroradiology CT protocols on patients' radiation dose and image quality. METHODS: We evaluated the effect of ASIR on six types of neuroradiologic CT studies: adult and pediatric unenhanced head CT, adult cervical spine CT, adult cervical and intracranial CT angiography, adult soft tissue neck CT with contrast, and adult lumbar spine CT. For each type of CT study, two groups of 100 consecutive studies were retrospectively reviewed: 100 studies performed with FBP and 100 studies performed with ASIR/FBP blending factor of 40 %/60 % with appropriate noise indices. The weighted volume CT dose index (CTDIvol), dose-length product (DLP) and noise were recorded. Each study was also reviewed for image quality by two reviewers. Continuous and categorical variables were compared by t test and free permutation test, respectively. RESULTS: For adult unenhanced brain CT, CT cervical myelography, cervical and intracranial CT angiography and lumbar spine CT both CTDIvol and DLP were lowered by up to 10.9 % (p < 0.001), 17.9 % (p = 0.005), 20.9 % (p < 0.001), and 21.7 % (p = 0.001), respectively, by using ASIR compared with FBP alone. Image quality and noise were similar for both FBP and ASIR. CONCLUSION: We recommend routine use of iterative reconstruction for neuroradiology CT examinations because this approach affords a significant dose reduction while preserving image quality.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Partant d'une perspective sémiotique appliquée aux débuts de film pour élargir l'approche à une réflexion historique sur l'intermédialité, cet article examine le postulat selon lequel les spectacles vivants qui précédaient la projection des films dans les années 1920 ont été en quelque sorte « happés » par le discours filmique. A travers l'examen d'un ensemble de films réalisés entre 1927 et 1937 qui accordent dans leurs génériques ou leurs prologues une place prépondérante à l'adresse vocale, l'auteur met en évidence certains phénomènes de résurgence de l'oralité propre à la période « muette », les speaker des premiers talkies endossant une fonction à certains égards similaire à celle du bonimenteur des premiers temps. L'accent est mis sur la production cinématographique de Guitry, dont la passion pour la « théâtralité » l'incite à proposer des formes singulières d'auto-mise en scène et d'adresse au spectateur. La question de la réflexivité des incipit passe également par la prise en compte de la dimension technologique, qui est parfois intégrée au film même, à l'instar de l'ouverture radiophonique de L'Atlantide de Pabst. Ces considérations s'inscrivent plus généralement dans une réflexion sur les diverses imitations de la voix vive à l'ère des technologies de l'audiovisuel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Total disc replacement (TDR) clinical success has been reported to be related to the residual motion of the operated level. Thus, accurate measurement of TDR range of motion (ROM) is of utmost importance. One commonly used tool in measuring ROM is the Oxford Cobbometer. Little is known however on its accuracy (precision and bias) in measuring TDR angles. The aim of this study was to assess the ability of the Cobbometer to accurately measure radiographic TDR angles. An anatomically accurate synthetic L4-L5 motion segment was instrumented with a CHARITE artificial disc. The TDR angle and anatomical position between L4 and L5 was fixed to prohibit motion while the motion segment was radiographically imaged in various degrees of rotation and elevation, representing a sample of possible patient placement positions. An experienced observer made ten readings of the TDR angle using the Cobbometer at each different position. The Cobbometer readings were analyzed to determine measurement accuracy at each position. Furthermore, analysis of variance was used to study rotation and elevation of the motion segment as treatment factors. Cobbometer TDR angle measurements were most accurate (highest precision and lowest bias) at the centered position (95.5%), which placed the TDR directly inline with the x-ray beam source without any rotation. In contrast, the lowest accuracy (75.2%) was observed in the most rotated and off-centered view. A difference as high as 4 degrees between readings at any individual position, and as high as 6 degrees between all the positions was observed. Furthermore, the Cobbometer was unable to detect the expected trend in TDR angle projection with changing position. Although the Cobbometer has been reported to be reliable in different clinical applications, it lacks the needed accuracy to measure TDR angles and ROM. More accurate ROM measurement methods need to be developed to help surgeons and researchers assess radiological success of TDRs.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les romancières maghrébines d'expression française essaient souvent de fairerésonner dans leurs oeuvres la voix interdite de toutes les femmes musulmanes, dereconstruire une identité mise en question. Cette entreprise est d'autant plus difficileque l'écriture reste encore une activité éminemment masculine (comme toutes cellesqui ont une projection publique) dans le monde arabe. Les difficultés qu'a tout écrivain francophone à faire publier ses textes au Maghreb sont ainsi redoublées s'il s'agit d'une écrivaine. Celles-ci, plus durement jugées par la critique (ou, sinon, suivant d'autres paramètres que ceux appliqués aux hommes écrivains, car on est plus enclin à rapporter le contenu des oeuvres à la biographie de leurs auteurs quand ceux-ci sont des femmes),doivent "faire ses preuves langagières", tel que l'exprime S. Rezzoug1. De cette façon,la femme qui écrit "renchérit souvent sur les principes de correction et de beau langage, et désireuse d'éviter la condamnation d'amoralisme, ou reproche plus grave, de narcissisme, use pour se dire d'une série de travestissements"...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Les romancières maghrébines d'expression française essaient souvent de fairerésonner dans leurs oeuvres la voix interdite de toutes les femmes musulmanes, dereconstruire une identité mise en question. Cette entreprise est d'autant plus difficileque l'écriture reste encore une activité éminemment masculine (comme toutes cellesqui ont une projection publique) dans le monde arabe. Les difficultés qu'a tout écrivain francophone à faire publier ses textes au Maghreb sont ainsi redoublées s'il s'agit d'une écrivaine. Celles-ci, plus durement jugées par la critique (ou, sinon, suivant d'autres paramètres que ceux appliqués aux hommes écrivains, car on est plus enclin à rapporter le contenu des oeuvres à la biographie de leurs auteurs quand ceux-ci sont des femmes),doivent "faire ses preuves langagières", tel que l'exprime S. Rezzoug1. De cette façon,la femme qui écrit "renchérit souvent sur les principes de correction et de beau langage, et désireuse d'éviter la condamnation d'amoralisme, ou reproche plus grave, de narcissisme, use pour se dire d'une série de travestissements"...

Relevância:

10.00% 10.00%

Publicador:

Resumo:

BACKGROUND: The potential effects of ionizing radiation are of particular concern in children. The model-based iterative reconstruction VEO(TM) is a technique commercialized to improve image quality and reduce noise compared with the filtered back-projection (FBP) method. OBJECTIVE: To evaluate the potential of VEO(TM) on diagnostic image quality and dose reduction in pediatric chest CT examinations. MATERIALS AND METHODS: Twenty children (mean 11.4 years) with cystic fibrosis underwent either a standard CT or a moderately reduced-dose CT plus a minimum-dose CT performed at 100 kVp. Reduced-dose CT examinations consisted of two consecutive acquisitions: one moderately reduced-dose CT with increased noise index (NI = 70) and one minimum-dose CT at CTDIvol 0.14 mGy. Standard CTs were reconstructed using the FBP method while low-dose CTs were reconstructed using FBP and VEO. Two senior radiologists evaluated diagnostic image quality independently by scoring anatomical structures using a four-point scale (1 = excellent, 2 = clear, 3 = diminished, 4 = non-diagnostic). Standard deviation (SD) and signal-to-noise ratio (SNR) were also computed. RESULTS: At moderately reduced doses, VEO images had significantly lower SD (P < 0.001) and higher SNR (P < 0.05) in comparison to filtered back-projection images. Further improvements were obtained at minimum-dose CT. The best diagnostic image quality was obtained with VEO at minimum-dose CT for the small structures (subpleural vessels and lung fissures) (P < 0.001). The potential for dose reduction was dependent on the diagnostic task because of the modification of the image texture produced by this reconstruction. CONCLUSIONS: At minimum-dose CT, VEO enables important dose reduction depending on the clinical indication and makes visible certain small structures that were not perceptible with filtered back-projection.