940 resultados para Plate Digitization
Resumo:
BACKGROUND Limited range of finger motion is a frequent complication after plate fixation of phalangeal fractures. The purpose of this study was to evaluate the results of plate fixation of extra-articular fractures of the proximal phalanx using current low-profile mini-fragment-systems. METHODS From 2006 to 2012, 32 patients with 36 extra-articular fractures of the proximal phalanx of the triphalangeal fingers were treated with open reduction and plate fixation (ORPF) using 1.2 and 1.5 mm mini-fragment systems. Patients presenting with open fractures grade 2 and 3 or relevant laceration of adjacent structures were excluded from the study. We retrospectively evaluated the rate of mal-union or non-union after ORPF, the need for revision surgery, for plate removal, and for tenolysis. Data were analyzed for further complications with regard to infections or complex regional pain syndrome (CRPS). RESULTS No infections were noted. Five patients developed transient symptoms of CRPS. Six weeks postoperatively, total active finger motion (TAM) averaged 183°, and all 32 patients underwent formal hand therapy. At the latest follow-up or at the time of plate removal, respectively, the mean TAM improved to 213°. Extension lag of proximal interphalangeal joints was found in 67 % of all fractured fingers. Secondary surgery was necessary in 14 of 32 patients (2 corrective osteotomies, 12 plate removals including 7 procedures explicitly because of reduced mobility). CONCLUSIONS Despite of new implant designs significant problems persist. Adhesions of extensor tendons leading to limited range of finger motion are still the most frequent complications after ORPF of proximal phalangeal fractures, even in absence of significant soft-tissue damage. LEVEL OF EVIDENCE Therapeutic, Retrospective, Level IV.
Resumo:
OBJECTIVE Proximal femoral osteotomy with stable fixation and sufficient correction. Low complication rates due to exact preoperative planning. INDICATIONS Congenital or traumatic femoral neck pseudarthrosis. Coxa vara. CONTRAINDICATIONS None. In severe deformities, a single femoral osteotomy may not solve the problem; thus, additional correction, e.g., a pelvic osteotomy, is required. SURGICAL TECHNIQUE Correct planning of the correction angle. Lateral approach. Subperiosteal detachment of vastus lateralis muscle. Place guide wire on the femoral neck to judge anteversion. Insert positioning wire 5 mm distal to trochanteric physis. Insert 2.8 mm Kirschner wire in the femoral neck. Osteotomy of the femur after marking the rotation by Kirschner wires or oscillating saw. Slide LC plate over Kirschner wires. Replace Kirschner wires with screws. Reduction of the femoral shaft to the plate with bone forceps. Definitive fixation of the plate to the femoral shaft by cortex or locking screws. Readaptation of vastus lateralis muscle over the plate. POSTOPERATIVE MANAGEMENT Partial weightbearing for 4-6 weeks depending on the age of the patient without any external fixation (e. g. cast) is possible. RESULTS Recent studies support the authors' findings of sufficient correction and stable fixation after proximal femoral osteotomy with the LCP pediatric hip plate. Low complication rates and stable fixation.
Resumo:
OBJECTIVE Correction of all kind of deformities at the distal part of the femur (supracondylar). INDICATIONS Flexion, extension osteotomies, and varus or valgus, and external or internal rotation osteotomies, and shortening osteotomies of the distal femur or combined surgical procedures (e.g., extension and de-rotation osteotomy). CONTRAINDICATIONS Osteotomy through unknown bony process. SURGICAL TECHNIQUE LCP system provides angular stable fixation. POSTOPERATIVE MANAGEMENT Without concomitant surgical procedures of soft tissue (e.g., patellar tendon shortening), early functional rehabilitation is possible with immediate weight bearing (35 kg for small fragment plates and 70 kg for large fragment plates). RESULTS The surgical procedure is safe and is associated with few complications. Overall complication rate in this series of patients was 3%.
Resumo:
PURPOSE To compare the initial stability and stability after fatigue of three different locking systems (Synthes(®), Stryker(®) and Medartis(®)) for mandibular fixation and reconstruction. METHOD Standard mandible locking plates with identical profile height (1,5 mm), comparable length and screws with identical diameter (2,0 mm) were used. Plates were fixed with six screws according a preparation protocol. Four point bending tests were then performed using artificial bone material to compare their initial stability and failure limit under realistic loading conditions. Loading of the plates was performed using of a servo hydraulic driven testing machine. The stiffness of the implant/bone construct was calculated using a linear regression on the experimental data included in a range of applied moment between 2 Nm and 6 Nm. RESULTS No statistical difference in the elastic stiffness was visible between the three types of plate. However, differences were observed between the systems concerning the maximal load supported. The Stryker and Synthes systems were able to support a significantly higher moment. CONCLUSION For clinical application all systems show good and reliable results. Practical aspects such as handling, possible angulation of screw fixation, possibility of screw/plate removal, etc. may favour one or the other plating system.
Resumo:
Biodegradable magnesium plate/screw osteosynthesis systems were implanted on the frontal bone of adult miniature pigs. The chosen implant geometries were based on existing titanium systems used for the treatment of facial fractures. The aim of this study was to evaluate the in vivo degradation and tissue response of the magnesium alloy WE43 with and without a plasma electrolytic surface coating. Of 14 animals, 6 received magnesium implants with surface modification (coated), 6 without surface modification (uncoated), and 2 titanium implants. Radiological examination of the skull was performed at 1, 4, and 8 weeks post-implantation. After euthanasia at 12 and 24 weeks, X-ray, computed tomography, and microfocus computed tomography analyses and histological and histomorphological examinations of the bone/implant blocks were performed. The results showed a good tolerance of the plate/screw system without wound healing disturbance. In the radiological examination, gas pocket formation was found mainly around the uncoated plates 4 weeks after surgery. The micro-CT and histological analyses showed significantly lower corrosion rates and increased bone density and bone implant contact area around the coated screws compared to the uncoated screws at both endpoints. This study shows promising results for the further development of coated magnesium implants for the osteosynthesis of the facial skeleton.
Resumo:
OBJECTIVE To evaluate use of a surgical technique commonly used in humans for treatment of cervical spondylotic myelopathy (CSM) in dogs. DESIGN Prospective case series. ANIMALS Dogs with CSM (n=10). METHODS Dogs weighing >30 kg that had CSM at 1 vertebral articulation were eligible for inclusion. Dogs had vertebral column distraction/fusion performed using a cortical ring allograft, cancellous autograft, and a spinal locking plate. Dogs were evaluated temporally by repeat neurological examinations and by client perception of postsurgical outcome, determined by telephone interview. RESULTS Nine dogs survived the immediate postoperative period. Seven of 8 dogs had moderate to complete improvement without recurrence (mean follow-up, 2.48 years). The most common postsurgical complications were screw loosening (n=4) and plate shifting (2), neither of which required surgical revision. One dog had pseudoarthrosis that may have negatively impacted outcome. CONCLUSION Treatment of single level CSM in dogs with ring allograft and a spinal locking plate system may lead to successful outcomes. The major problems encountered with included cost of the implants and adjusting the system designed for humans to fit the vertebral column of a dog. CLINICAL RELEVANCE For dogs with CSM at a single level, the use of a spinal locking plate in combination with a cortical ring allograft can be an effective surgical treatment. Costs of the implants as well as anatomic differences in dogs make this type of surgery less appealing.
Resumo:
Diversions from streams are often screened to prevent the loss of or injury to fish. Hydraulic criteria meant to protect fish that encounter screens have been developed, but primarily for screens that are vertical to the water flow rather than horizontal. For this reason, we measured selected hydraulic variables and released wild rainbow trout Oncorhynchus mykiss over two types of horizontal flat-plate fish screens in the field. Our goal was to assess the efficacy of these screens under a variety of conditions in the field and provide information that could be used to develop criteria for safe fish passage. We evaluated three different inverted-weir screens over a range of strewn (0.24-1.77 m(3)/s) and diversion flows (0.10-0.31 m(3)/s). Approach velocities (AVs) ranged from 3 to 8 cm/s and sweeping velocities (SVs) from 69 to 143 cm/s. We also evaluated a simple backwatered screen over stream flows of 0.23-0.79 m(3)/s and diversion flows of 0.08-0.32 m(3)/s. The mean SVs for this screen ranged from 15 to 66 cm/s and the mean AVs from 1 to 5 cm/s. The survival rates of fish held for 24 h after passage over these screens exceeded 98%. Overall, the number of fish-screen contacts was low and the injuries related to passage were infrequent and consisted primarily of minor fin injuries. Our results indicate that screens of this type have great potential as safe and effective fish screens for small diversions. Care must be taken, however, to avoid operating conditions that produce shallow or no water over the screen surface, situations of high AVs and low SVs at backwatered screens, and situations producing a localized high AV with spiraling flow.
Resumo:
New geochemical data from the Cocos Plate constrain the composition of the input into the Central American subduction zone and demonstrate the extent of influence of the Galápagos Hotspot on the Cocos Plate. Samples include sediments and basalts from Ocean Drilling Program (ODP) Site 1256 outboard of Nicaragua, gabbroic sills from ODP Sites 1039 and 1040, tholeiitic glasses from the Fisher Ridge off northwest Costa Rica, and basalts from the Galápagos Hotspot Track outboard of Central Costa Rica. Site 1256 basalts range from normal to enriched MORB in incompatible elements and have Pb and Nd isotopic compositions within the East Pacific Rise MORB field. The sediments have similar 206Pb/204Pb and only slightly more radiogenic 207Pb/204Pb and 208Pb/204Pb isotope ratios than the basalts. Altered samples from the subducting Galápagos Hotspot Track have similar Nd and Pb isotopic compositions to fresh Galápagos samples but have significantly higher Sr isotopic composition, indicating that the subduction input will have a distinct geochemical signature from Galápagos-type mantle material that may be present in the wedge beneath Costa Rica. Gabbroic sills from Sites 1039 and 1040 in East Pacific Rise (EPR) crust show evidence for influence of the Galápagos Hotspot ?100 km beyond the morphological hotspot track.