985 resultados para Pelvic-floor electrostimulation
Resumo:
The effects of the inclusion of oat hulls (OH) and sugar beet pulp (SBP) in the diet on gizzard characteristics, apparent ileal nutrient digestibility (AID), and Clostridium perfringens, Enterobacteriaceae, and Lactobacillus proliferation in the ceca were studied in 36 d?old broilers. There were a control diet with a low CF content (1.61%) and 2 additional diets that resulted from the dilution of this feed with 5% of either OH or SBP.
Resumo:
The dynamic floor loads induced by crowds in gymnasium or stadium structures are commonly modelled by superposition of the individual contributions using reduction factors for the different Fourier coefficients. These Fourier coefficients and the reduction factors are calculated using full scale measurements. Generally the testing is performed on platforms or structures that can be considered rigid, such that the natural frequencies are higher than the frequencies of the spectator movement. In this paper we shall present the testing done on a structure that used to be a gymnasium as well as the procedure used to identify its dynamic properties and a first evaluation of the socalled “group effect”.
Resumo:
Purpose: Accurate delineation of the rectum is of high importance in off-line adaptive radiation therapy since it is a major dose-limiting organ in prostate cancer radiotherapy. The intensity-based deformable image registration (DIR) methods cannot create a correct spatial transformation if there is no correspondence between the template and the target images. The variation of rectal filling, gas, or feces, creates a noncorrespondence in image intensities that becomes a great obstacle for intensity-based DIR. Methods: In this study the authors have designed and implemented a semiautomatic method to create a rectum mask in pelvic computed tomography (CT) images. The method, that includes a DIR based on the demons algorithm, has been tested in 13 prostate cancer cases, each comprising of two CT scans, for a total of 26 CT scans. Results: The use of the manual segmentation in the planning image and the proposed rectum mask method (RMM) method in the daily image leads to an improvement in the DIR performance in pelvic CT images, obtaining a mean value of overlap volume index = 0.89, close to the values obtained using the manual segmentations in both images. Conclusions: The application of the RMM method in the daily image and the manual segmentations in the planning image during prostate cancer treatments increases the performance of the registration in presence of rectal fillings, obtaining very good agreement with a physician's manual contours.
Resumo:
Purpose: Accurate delineation of the rectum is of high importance in off-line adaptive radiation therapy since it is a major dose-limiting organ in prostate cancer radiotherapy. The intensity-based deformable image registration (DIR) methods cannot create a correct spatial transformation if there is no correspondence between the template and the target images. The variation of rectal filling, gas, or feces, creates a noncorrespondence in image intensities that becomes a great obstacle for intensity-based DIR. Methods: In this study the authors have designed and implemented a semiautomatic method to create a rectum mask in pelvic computed tomography (CT) images. The method, that includes a DIR based on the demons algorithm, has been tested in 13 prostate cancer cases, each comprising of two CT scans, for a total of 26 CT scans. Results: The use of the manual segmentation in the planning image and the proposed rectum mask method (RMM) method in the daily image leads to an improvement in the DIR performance in pelvic CT images, obtaining a mean value of overlap volume index = 0.89, close to the values obtained using the manual segmentations in both images. Conclusions: The application of the RMM method in the daily image and the manual segmentations in the planning image during prostate cancer treatments increases the performance of the registration in presence of rectal fillings, obtaining very good agreement with a physician's manual contours.