998 resultados para Optical instrument transformer


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Changes in intracellular Na(+) concentration underlie essential neurobiological processes, but few reliable tools exist for their measurement. Here we characterize a new synthetic Na(+)-sensitive fluorescent dye, Asante Natrium Green (ANG), with unique properties. This indicator was excitable in the visible spectrum and by two-photon illumination, suffered little photobleaching and located to the cytosol were it remained for long durations without noticeable unwanted effects on basic cell properties. When used in brain tissue, ANG yielded a bright fluorescent signal during physiological Na(+) responses both in neurons and astrocytes. Synchronous electrophysiological and fluorometric recordings showed that ANG produced accurate Na(+) measurement in situ. This new Na(+) indicator opens innovative ways of probing neuronal circuits.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La recent publicació del Dizionario biografico degli anarchiciitaliani1 ens dóna l'oportunitat per ressenyar una sèrie de diccionaris sobre el moviment obrer internacional i oferir unaaproximació de com des de l'acadèmia i del món dels professionals de la història hom s'ha acostat a aquestes eines de treball amb les seves potencialitats heurístiques. L'al·licient de reflexionar sobre aquests volums de caràcter enciclopèdic rau en el fet d'intentar contextualitzar-los en eldebat europeu, i no sols del vell continent, sobre metodologies històriqueso, fins i tot, en el camp de la història dels conceptes que en els últims anysha catalitzat un interès creixent en els historiadors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

La recent publicació del Dizionario biografico degli anarchiciitaliani1 ens dóna l'oportunitat per ressenyar una sèrie de diccionaris sobre el moviment obrer internacional i oferir unaaproximació de com des de l'acadèmia i del món dels professionals de la història hom s'ha acostat a aquestes eines de treball amb les seves potencialitats heurístiques. L'al·licient de reflexionar sobre aquests volums de caràcter enciclopèdic rau en el fet d'intentar contextualitzar-los en eldebat europeu, i no sols del vell continent, sobre metodologies històriqueso, fins i tot, en el camp de la història dels conceptes que en els últims anysha catalitzat un interès creixent en els historiadors.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The method of instrumental variable (referred to as Mendelian randomization when the instrument is a genetic variant) has been initially developed to infer on a causal effect of a risk factor on some outcome of interest in a linear model. Adapting this method to nonlinear models, however, is known to be problematic. In this paper, we consider the simple case when the genetic instrument, the risk factor, and the outcome are all binary. We compare via simulations the usual two-stages estimate of a causal odds-ratio and its adjusted version with a recently proposed estimate in the context of a clinical trial with noncompliance. In contrast to the former two, we confirm that the latter is (under some conditions) a valid estimate of a causal odds-ratio defined in the subpopulation of compliers, and we propose its use in the context of Mendelian randomization. By analogy with a clinical trial with noncompliance, compliers are those individuals for whom the presence/absence of the risk factor X is determined by the presence/absence of the genetic variant Z (i.e., for whom we would observe X = Z whatever the alleles randomly received at conception). We also recall and illustrate the huge variability of instrumental variable estimates when the instrument is weak (i.e., with a low percentage of compliers, as is typically the case with genetic instruments for which this proportion is frequently smaller than 10%) where the inter-quartile range of our simulated estimates was up to 18 times higher compared to a conventional (e.g., intention-to-treat) approach. We thus conclude that the need to find stronger instruments is probably as important as the need to develop a methodology allowing to consistently estimate a causal odds-ratio.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

An Actively Heated Fiber Optics (AHFO) method to estimate soil moisture is tested and the analysis technique improved on. The measurements were performed in a lysimeter uniformly packed with loam soil with variable water content profiles. In the first meter of the soil profi le, 30 m of fiber optic cable were installed in a 12 loops coil. The metal sheath armoring the fiber cable was used as an electrical resistance heater to generate a heat pulse, and the soil response was monitored with a Distributed Temperature Sensing (DTS) system. We study the cooling following three continuous heat pulses of 120 s at 36 W m(-1) by means of long-time approximation of radial heat conduction. The soil volumetric water contents were then inferred from the estimated thermal conductivities through a specifically calibrated model relating thermal conductivity and volumetric water content. To use the pre-asymptotic data we employed a time correction that allowed the volumetric water content to be estimated with a precision of 0.01-0.035 (m(3) m(-3)). A comparison of the AHFO measurements with soil-moisture measurements obtained with calibrated capacitance-based probes gave good agreement for wetter soils [discrepancy between the two methods was less than 0.04 (m(3) m(-3))]. In the shallow drier soils, the AHFO method underestimated the volumetric water content due to the longertime required for the temperature increment to become asymptotic in less thermally conductive media [discrepancy between the two methods was larger than 0.1 (m(3) m(-3))]. The present work suggests that future applications of the AHFO method should include longer heat pulses, that longer heating and cooling events are analyzed, and, temperature increments ideally be measured with higher frequency.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Following the decision of the Swiss Association for Home Care Services to adopt the Resident Assessment Instrument (RAI), the RAI-Home Care is gradually implemented in all home care services in Switzerland. Based on a comprehensive geriatric assessment, the RAI not only allows to establish an individualized plan of care, but also generates quality indicators and a case-mix classification system that helps financing and planning resources. This article describes the five steps of the RAI-Home Care process and discusses the strengths, future and limitations of the RAI.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The theoretical context of this study is related with the observational methodology in the context of group games and sports studies, specifically Handball. Thus, this study intends to analyze the performance of the pivot player in the World Cup 2007 - Germany, European 2008 - Norway 2008 and China OG 2008 in a qualitative dimension. Our purpose was to get as much information as possible about the whole activity of the pivot player, by identifying sequential patterns of behaviour or conduct of the player/game, by using the sequential analysis. The observation instrument used to meet the main purpose of this work consists of a combination of format fields (FF) and systems of categories (SC). The codifications undertaken occurred in several handball games. Using this instrument we have shown that it provides support for the purposes for which it was developed, allowing more research into the offensive process of handball. Besides this, it makes possible the analysis of aspects of the game through perspective and contextual sequences, which we consider to be more accurate, to fit the "reality" of a game such as handball.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The following paper introduces a new approach to the analysis of offensive game in football. Therefore, the main aim of this study was to create an instrument for collecting information for the analysis of offensive action and interactions game. The observation instrument that was used to accomplish the main objective of this work consists of a combination of format fields (FC) and systems of categories (SC). This methodology is a particular strategy of the scientific method that has as an objective to analyse the perceptible behaviour that occurs in habitual contexts, allowing them to be formally recorded and quantified and using an ad hoc instrument in order to obtain a behaviour systematic registration that, since they have been transformed in quantitative data with the necessary reliability and validity determined level, will allow analysis of the relations between these behaviours. The codifications undertaken to date in various games of football have shown that it serves the purposes for which it was developed, allowing more research into the offensive game methods in football.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

PURPOSE: To describe the use of anterior segment optical coherence tomography (AS-OCT) to clarify the position and patency of aqueous shunt devices in the anterior chamber of eyes where corneal edema or tube position does not permit a satisfactory view. DESIGN: Noncomparative observational case series. METHODS: Four cases are reported in which aqueous shunt malposition or obstruction was suspected but the shunt could not be seen on clinical examination. The patients underwent AS-OCT to identify the position and patency of the shunt tip. RESULTS: In each case, AS-OCT provided data regarding tube position and/or patency that could not be obtained by slit-lamp examination or by gonioscopy that influenced management. CONCLUSIONS: AS-OCT can be used to visualize anterior chamber tubes in the presence of corneal edema that precludes an adequate view or in cases where the tube is retracted into the cornea. In such cases, AS-OCT is useful in identifying shunt patency and position, which helps guide clinical decision making.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This paper describes a low-cost microprocessed instrument for in situ evaluating soil temperature profile ranging from -20.0°C to 99.9°C, and recording soil temperature data at eight depths from 2 to 128 cm. Of great importance in agriculture, soil temperature affects plant growth directly, and nutrient uptake as well as indirectly in soil water and gas flow, soil structure and nutrient availability. The developed instrument has potential applications in the soil science, when temperature monitoring is required. Results show that the instrument with its individual sensors guarantees ±0.25°C accuracy and 0.1°C resolution, making possible localized management changes within decision support systems. The instrument, based on complementary metal oxide semiconductor devices as well as thermocouples, operates in either automatic or non-automatic mode.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

This article summarizes the new trends of Optical Microscopy applied to Materials, with examples of applications that illustrate the capabilities of thetechnique.