933 resultados para On-line control process for attributes


Relevância:

100.00% 100.00%

Publicador:

Resumo:

BACKGROUND: The objective of this study was to compare cycle control, cycle-related characteristics and bodyweight effects of NuvaRing with those of a combined oral contraceptive (COC) containing 30 microg of ethinyl estradiol and 3 mg of drospirenone. METHODS: A randomized, multicentre, open-label trial in which 983 women were treated (intent-to-treat population) with NuvaRing or the COC for 13 cycles. RESULTS: Breakthrough bleeding or spotting during cycles 2-13 was in general less frequent with NuvaRing than that with the COC (4.7-10.4%) and showed a statistically significant odds ratio of 0.61 (95% confidence interval: 0.46, 0.80) with longitudinal analysis. Intended bleeding was significantly better for all cycles with NuvaRing (55.2-68.5%) than that with the COC (35.6-56.6%) (P < 0.01). Changes from baseline in mean bodyweight and body composition parameters were relatively small for both groups with no notable between-group differences. CONCLUSION: NuvaRing was associated with better cycle control than the COC, and there was no clinically relevant difference between the two groups in bodyweight.

Relevância:

100.00% 100.00%

Publicador:

Resumo:

In external beam radiotherapy, electronic portal imaging becomes more and more an indispensable tool for the verification of the patient setup. For the safe clinical introduction of high dose conformal radiotherapy like intensity modulated radiation therapy, on-line patient setup verification is a prerequisite to ensure that the planned dosimetric coverage of the tumor volume is actually realized in the patient. Since the direction of setup fields often deviates from the direction of the treatment beams, extra dose is delivered to the patient during the acquisition of these portal images which may reach clinical relevance. The aim of this work was to develop a new acquisition mode for the PortalVision aS500 electronic portal imaging device from Varian Medical Systems that allows one to take portal images with reduced dose while keeping good image quality. The new acquisition mode, called RadMode, selectively enables and disables beam pulses during image acquisition allowing one to stop wasting valuable dose during the initial acquisition of "reset frames." Images of excellent quality can be taken with 1 MU only. This low dose per image facilitates daily setup verification with considerably reduced extra dose.

Relevância:

100.00% 100.00%

Publicador: