519 resultados para Nerves.


Relevância:

10.00% 10.00%

Publicador:

Resumo:

The literature suggests that diabetic patients may have altered tear chemistry and tear secretion as well as structural and functional changes to the corneal epithelium, endothelium and nerves. These factors, together with a reported increased incidence of corneal infection, suggest that diabetic patients may be particularly susceptible to developing ocular complications during contact lens wear. Reports of contact lens-induced complications in diabetic patients do exist, although a number of these reports concern patients with advanced diabetic eye disease using lenses on an extended wear basis. Over the past decade or so, there have been published studies documenting the response of the diabetic eye to more modern contact lens modalities. The results of these studies suggest that contact lenses can be a viable mode of refractive correction for diabetic patients. Furthermore, new research suggests that the measurement of tear glucose concentration could, in future, be used to monitor metabolic control non-invasively in diabetic patients. This could be carried out using contact lenses manufactured from hydrogel polymers embedded with glucose-sensing agents or nanoscale digital electronic technology. The purpose of this paper is to review the literature on the anterior ocular manifestations of diabetes, particularly that pertaining to contact lens wear. © 2012 The Authors. Clinical and Experimental Optometry © 2012 Optometrists Association Australia.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Peripheral nerves have demonstrated the ability to bridge gaps of up to 6 mm. Peripheral Nerve System injury sites beyond this range need autograft or allograft surgery. Central Nerve System cells do not allow spontaneous regeneration due to the intrinsic environmental inhibition. Although stem cell therapy seems to be a promising approach towards nerve repair, it is essential to use the distinct three-dimensional architecture of a cell scaffold with proper biomolecule embedding in order to ensure that the local environment can be controlled well enough for growth and survival. Many approaches have been developed for the fabrication of 3D scaffolds, and more recently, fiber-based scaffolds produced via the electrospinning have been garnering increasing interest, as it offers the opportunity for control over fiber composition, as well as fiber mesh porosity using a relatively simple experimental setup. All these attributes make electrospun fibers a new class of promising scaffolds for neural tissue engineering. Therefore, the purpose of this doctoral study is to investigate the use of the novel material PGD and its derivative PGDF for obtaining fiber scaffolds using the electrospinning. The performance of these scaffolds, combined with neural lineage cells derived from ESCs, was evaluated by the dissolvability test, Raman spectroscopy, cell viability assay, real time PCR, Immunocytochemistry, extracellular electrophysiology, etc. The newly designed collector makes it possible to easily obtain fibers with adequate length and integrity. The utilization of a solvent like ethanol and water for electrospinning of fibrous scaffolds provides a potentially less toxic and more biocompatible fabrication method. Cell viability testing demonstrated that the addition of gelatin leads to significant improvement of cell proliferation on the scaffolds. Both real time PCR and Immunocytochemistry analysis indicated that motor neuron differentiation was achieved through the high motor neuron gene expression using the metabolites approach. The addition of Fumaric acid into fiber scaffolds further promoted the differentiation. Based on the results, this newly fabricated electrospun fiber scaffold, combined with neural lineage cells, provides a potential alternate strategy for nerve injury repair.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

CHAPTER II - The Chrysocyon brachyurus is the biggest South American canid which has a high frequency of dental injuries, both in wild and captivity. Thus, veterinary procedures are necessary to preserve the feeding capacity of hundreds of captive specimens worldwide. The aim of this study was to study the mandibular morphometry of maned wolf with emphasis on the establishment of anatomic references to the anesthetic blockage of the inferior alveolar and mental nerves. Therefore, 15 measurements in 22 hemimandibles of C. brachyurus adults were taken. For extra-oral technique of blockage of the inferior alveolar nerve at the level of the mandibular foramen, it is stated that the needle should be advanced, close to the medial surface of the mandibular ramus, by 11.4 mm perpendiculary from the palpable concavity. Alternatively, the needle can be introduced for 30.4 mm from the angular process at 20-25 degrees angle with the ventral margin. For blocking only the mentual nerve, it is recommended the introduction of needle for 10 mm, close to the lateral aspect of the mandibular body, at the level of the lower first premolar. The mandibular foramen showed similars position, size and symmetry in the maned wolfs specimens examined. The comparison of the data with those available for other carnivores reflects the necessity for determining these anatomical references specifically for each species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

The objective of this research is to study the origin of the lumbosacral plexus and its nerves in coatis (Nasua nasua). Six adult specimens, three males and three females, were used in this research. The animals were donated by IBAMA / GO or were collected when found dead by the edges of highways in Southeast Goiás. The specimens were fixed in aqueous 10% formaldehyde solution and preserved in the same solution. The observations reveal that the lumbosacral plexus of the coati has a structure with few intercommunications between its components. There are no typical handle formations, but the roots or its branches converge to form the nerves that are driven to the pelvic limb. The components of the Lumbosacral Plexus are ventral branches of L4 to S3. The Lumbosacral plexus generates several short nerves destined to pelvic structures and, at the same time, three long nerves: femoral, obturator and sciatic, all destined to the hind limb.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: We have reported that the changes in the pupillary shape in response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al. PLoS One, 2014). This study investigates the changes in the pupillary shapes in response to electrical stimulations of the sclera of peripheral cornea in cats and porcines. Methods: Two enucleated eyes of two cats and three enucleated porcine eyes were studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter). The stimulation was performed at every 45 degree over the entire circular region on the sclera near the cornea. The pupillary images were recorded before and 4 s (cat) and 10 s (pig) after the stimulation and the change in the pupil diameter (Δr) was quantified. The pupillary images were obtained with a custom-built compact wavefront aberrometer (Uday et al. J Cataract Refract Surg, 2013). Results: In a cat eye, the pupil was dilated by the electrical stimulation at six out of eight orientations (before stimulation pupil diameter r=10.10±0.49 mm, Δr=0.33±0.12 mm). The pupil dilated only toward the electrode (relative eccentricity of the pupil center to the pupil diameter change amount rdec=1.15±0.28). In the porcine eyes, the pupils were constricted by the electrical stimulations at the temporal and nasal orientations (r=10.04±0.57 mm, Δr=1.52±0.70 mm). The pupils contracted symmetrically (rdec=0.30±0.12). Conclusions: With electrical stimulation in the sclera of the peripheral cornea, asymmetric mydriasis in cat eyes and symmetrical miosis in porcine eyes were observed. Under the assumption that the electrical stimulation stimulated both muscles that contribute to the pupil control, our hypothesis proposed here is that the pupil dilator is stronger than the pupil sphincter in cat, and pupil sphincter is stronger than pupil dilator in porcine.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Purpose: We have reported that the changes in the accommodative response to electrical stimulation of the branches of the ciliary nerves in cats. (Miyagawa et al, PLoS One, 2014). We have also reported that no robust accommodative responses to the electrical stimulations of the sclera of peripheral cornea (SSPC) were observed in enucleated porcine eyes (Mihashi et al, VPOptics, 2014). In this study, accommodative responses to SSPC stimulation in cats and porcines were investigated. Methods: Two eyes of two cats under anesthesia and after they were sacrificed were studied. Three enucleated porcine eyes obtained from a local slaughterhouse were also studied. Trains of biphasic pulses (current, 3 mA; duration, 2 ms/phase; frequency, 40 Hz) were applied using a tungsten electrode (0.3mm diameter) from several orientations. Wavefront sensing with a compact wavefront aberrometer (Uday et al J Cataract Refract Surg, 2013) were performed before and 4 s (cat) and 10 s (pig) after the stimulations and wavefront aberrations including spherical errors were analyzed over a 4-mm pupil area. Results: In the first cat under anesthesia, at three out of seven stimulus positions, 0.2 D hyperopic accommodative responses were observed and in two orientations, myopic responses were observed. For the other cat, weak accommodative responses including astigmatic changes were observed. In the sacrificed condition of the second cat, 0.1 D myopic response was observed for one stimulus orientation and the smaller responses were observed at six out of eight stimulus positions. No accommodative responses were elicited for the enucleated porcine eyes. Conclusions: In the anesthetized cats, electrical stimulation of the SSPC induced accommodative responses; the responses were unstable and weaker than the responses by the ciliary nerve stimulations we observed in our previous study. Small accommodative responses were observed after one of two cats had been sacrificed, but no accommodative responses were detected in the enucleated porcine eyes. Further studies are needed to confirm difference in the accommodation functions in the two species.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MORENO,Cléa Maria da Costa,ENDERS,Bertha Cruz, SIMPSON, Clélia Albino. Avaliação das capacitações de Hanseníase: enfermeiros opinião de médicos e enfermeiros das equipes de saúde da família. Revista Brasileira de Enfermagem, Brasília, v.61,n.esp.p. 671-5.2008.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

A study of the diencephalic syndrome in cases so far collected from the literature was carried out on the clinical, macroscopic and histological brain findings found recorded in, respectively, 29, 25 and 34 cases. For comparison, 3 further cases with this syn- drome were described, in which a diagnosis of optic nerve glioma could be made. The review of the 39 cases with the diencephalic syndrome has shown that in 90°/o of these patients an extensive glioma of the 3rd ventricle had been present. 70% of these patients had additional glioma of optic nerves and/or chiasm with an equal amount of infants having diminished visual acuity in one or both eyes. From these, so far unreported, findings, strong suggestive evidence was thus presented that the ‘diencephalic syndrome’ described in infants was indeed a mor¬bid entity, namely, a hypothalamo-optic glioma. The further question whether this brain tumour was a primary optic nerve rather than a primary diencephalic glioma could presently not be firmly answered from the reviewed data of the literature. © 1972 S. Karger AG, Basel.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Aim. Carotid artery stenting (CAS) is the treatment of choice for recurrent stenosis after carotid endarterectomy (CEA). However a significative incidence of in-stent restenosis could be occurred. Despite classical CEA leads to good results, in selective cases bypass graft may be the best treatment of in-stent restenosis. Case reports. We describe two cases of carotid bypass graft performed to treat a recurrent in-stent stenosis after CAS for post-CEA restenosis. No death and cardiac complication occurred and no cranial nerves impairment was detected. Conclusion. Prosthetic bypass graft is safe and effective in treatment of in-stent recurrent restenosis after CEA restenosis.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

MORENO,Cléa Maria da Costa,ENDERS,Bertha Cruz, SIMPSON, Clélia Albino. Avaliação das capacitações de Hanseníase: enfermeiros opinião de médicos e enfermeiros das equipes de saúde da família. Revista Brasileira de Enfermagem, Brasília, v.61,n.esp.p. 671-5.2008.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Background: Optical Projection Tomography (OPT) is a microscopic technique that generates three dimensional images from whole mount samples the size of which exceeds the maximum focal depth of confocal laser scanning microscopes. As an advancement of conventional emission-OPT, Scanning Laser Optical Tomography (SLOTy) allows simultaneous detection of fluorescence and absorbance with high sensitivity. In the present study, we employ SLOTy in a paradigm of brain plasticity in an insect model system. Methodology: We visualize and quantify volumetric changes in sensory information procession centers in the adult locust, Locusta migratoria. Olfactory receptor neurons, which project from the antenna into the brain, are axotomized by crushing the antennal nerve or ablating the entire antenna. We follow the resulting degeneration and regeneration in the olfactory centers (antennal lobes and mushroom bodies) by measuring their size in reconstructed SLOTy images with respect to the untreated control side. Within three weeks post treatment antennal lobes with ablated antennae lose as much as 60% of their initial volume. In contrast, antennal lobes with crushed antennal nerves initially shrink as well, but regain size back to normal within three weeks. The combined application of transmission-and fluorescence projections of Neurobiotin labeled axotomized fibers confirms that recovery of normal size is restored by regenerated afferents. Remarkably, SLOTy images reveal that degeneration of olfactory receptor axons has a trans-synaptic effect on second order brain centers and leads to size reduction of the mushroom body calyx. Conclusions: This study demonstrates that SLOTy is a suitable method for rapid screening of volumetric plasticity in insect brains and suggests its application also to vertebrate preparations.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Työssä selvitettiin sähkötoimisten käsiproteesien nykyteknologian taso. Selvitettäviä asioita olivat keskushermoston ja proteesin välisen hermokytkennän toteutustapa, sähkötoimisten käsiproteesien keskeiset tekniset ominaisuudet sekä käsiproteesin mekaaniset toteutustavat. Tutkimus suoritettiin kirjallisuustutkimuksena. Työhön valittiin esimerkkejä kaupallisesti saatavilla olevista käsiproteeseista jotka löytyivät internetistä hakemalla kaikkein edisty-neintä käsiproteesia. Työstä rajattiin pois proteesin suora kytkeminen keskushermostoon. Liikeinformaation välitys aivoilta proteesille onnistuu mittaamalla lihassähkökäyrä erilaisilla ihon ja lihasten päälle, ihon alle lihaksien yhteyteen tai suoraan hermojen yhteyteen asete-tuilla elektrodeilla. Lihassähkökäyrän mittaamisessa ihon pinnalta on ongelmana sähkömag-neettinen säteily, hiki, joka muuttaa ihon impedanssia ja elektrodien meneminen pois paikal-taan. Ihon alle asetettavat elektrodit kapseloituvat, mikä heikentää niiden toimintaa ja nii-den ihon läpi kulkevat johdot voivat altistaa kohdan infektioille tai takertua johonkin. Her-moihin suorassa kosketuksissa olevat elektrodit aiheuttavat lisäksi hermopinteen. Kohden-netulla uudelleenhermotuksella voidaan hermosyyt johtaa lihaksiin, jolloin lihaksista saa-daan biologiset vahvistimet lihassähkökäyrää varten tai korvaavalle ihoalueelle, johon koh-distuva kosketus tuottaa tuntemuksen käteen kohdistuvasta kosketuksesta. Käden menet-tämisen myötä menetettävät hermo-ohjaustiedot voivat osittain korvautua aivojen mukau-tuvuuden ansiosta, mikä mahdollistaa tekokäden käyttämisen oppimisen samalla tavoin kuin polkupyörällä ajon. Hermotakaisinkytkentä mahdollistaa proteesin paremman hallin-nan. On mahdollista valmistaa keinoihoa johon kohdistuva paine saa aikaan muutoksen sen sähköisissä ominaisuuksissa, mitä voidaan sitten käyttää varsinaisen hermoärsytyksen luo-van laitteen, kuten tynkää ärsyttävän täryttimen, ohjaamisessa. On mahdollista valmistaa keinolihaksia joiden avulla nivelten liike voidaan toteuttaa luonnollisen kaltaisilla rakenteilla ja jotka ovat jopa kymmeniä kertoja voimakkaampia kuin aidot lihakset. Nykyteknologian avulla on mahdollista rakentaa käsiproteesi joka liikeradoiltaan, voimal-taan ja hermotakaisinkytkennän osalta vastaa lähes täydellisesti aitoa ihmiskättä. Haasteena on vielä kokeiluasteella oleva teknologian taso sekä korkea hinta.

Relevância:

10.00% 10.00%

Publicador:

Resumo:

Autologous nerve grafts are the current gold standard for the repair of peripheral nerve injuries. However, there is a need to develop an alternative to this technique, as donor-site morbidities such as neuroma formation and permanent loss of function are a few of the limitations concerned with this technique. Artificial nerve conduits have therefore emerged as an alternative for the repair of short peripheral nerve defects of less than 30 mm, however they do not surpass autologous nerve grafts clinically. To develop a nerve conduit that supports regeneration over long nerve gaps and in large diameter nerves, researchers have focused on functionalizing of the conduits by studying the components that enhance nerve regeneration such as micro/nano-topography, growth factor delivery systems, supportive cells and extracellular matrix (ECM) proteins as well as understanding the complex biological reactions that take place during peripheral nerve regeneration. This thesis presents strategies to improve peripheral nerve interfaces to better the regenerative potential by using dorsal root ganglions (DRGs) isolated from neonatal rats as an in vitro model of nerve regeneration. The work started off by investigating the usefulness of a frog foam protein Ranaspumin-2 (Rsn2) to coat biomaterials for compatibility, this lead to the discovery of temporary cell adhesion on polydimethylsiloxane (PDMS), which was investigated as a suitable tool to derive cell-sheets for nerve repair. The influence of Rsn2 anchored to specific adhesion peptide sequences, such as isoleucine-lysine-valine-alanine-valine (IKVAV), a sequence derived from laminin proven to promote cell adhesion and neurite outgrowth, was tested as a useful means to influence nerve regeneration. This approach improves the axonal outgrowth and maintains outgrowth long term. Based on the hypothesis that combinational modulation of substrate topography, stiffness and neurotrophic support, affects axonal outgrowth in whole DRGs, dissociated DRGs were used to assess if these factors similarly act at the single cell level. Rho associated protein kinase (ROCK) and myosin II inhibitors, which affect cytoskeletal contractility, were used to influence growth cone traction forces and have shown that these factors work in combination by interfering with growth cone dynamic creating a different response in axonal outgrowth at the single cell level.