981 resultados para Mini-implant


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim: To describe the adaptation of the Edentulous Ridge Expansion (E.R.E.) technique for implant removal. Material and Methods: The E.R.E. technique for the removal of failed implants is described in detail. A clinical case is also reported. In a patient carrying a full arch removable prosthesis in the upper jaw, sustained by two bars, two out of five implants were found to be fractured. Bucco-lingual partial-thickness flaps were used to access the fractured implants. The implants were subsequently removed applying the E.R.E. technique. Two recipient sites were prepared in the same position, using bone expanders, and two new implants were installed. Results: After 4 months of healing, the implants were integrated and a new bar was fabricated, and the old prosthesis readapted. Conclusion: The ERE technique may be successfully applied for the removal of failed implants, and the immediate or delayed reinstallation of new implants. © 2012 John Wiley & Sons A/S.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The planting of lettuce in greenhouses, as well as covering beds with a polyethylene sheet, is a viable technology, promoting improvements in microclimatic conditions of the environment. In view of the little information on mini-lettuce, the aim of this work was to evaluate the performance of three cultivars of crisp minilettuce ('Green Frizzly', 'Red Frizzly no. 1' and 'Red Frizzly no. 2') with and without ground cover, under different spacings (20 × 15 cm and 20 × 20 cm), in three planting times (1: November 16, 2004; 2: December 17, 2004; and 3: January 20, 2005). The study was conducted in a greenhouse at UNESP-FCAV, Jaboticabal-SP. The experiments were carried out using a randomized block design, following a 3 × 2 × 2 factorial scheme with 12 treatments and three repetitions. The characteristics evaluated were plant height (cm), head diameter (cm), fresh weight (g) and number of leaves per plant. Planting time 3 was shown to be favorable for all the characteristics analyzed. 'Red Frizzly no. 2' was found to be the most suited to planting time 1, and for planting times 2 and 3, this cultivar did not differ from 'Red Frizzly no. 1'. The factor ground cover was not found to affect the characteristics evaluated, and therefore, cultivation without ground cover is recommended. The spacing 20 × 15 cm was shown to be favorable, resulting in cultivation with the highest populations, thereby increasing productivity. Based on the results obtained and for the conditions in which the experiment was conducted, it can be concluded that: planting time 3 (January 20, 2005) was the most favorable; the cultivars 'Red Frizzly no. 2' and 'Red Frizzly no. 1' are adapted to all the planting times; and cultivation without ground cover using a spacing of 20 × 15 cm was the most suitable.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presenta la coordinación o unión de las expresiones de búsqueda.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Tiene por objetivo facilitar al personal de las unidades de información de la Red IPALCA la realización de funciones utilizando el Mini-Micro CDS/ISIS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contiene el procedimiento de instalación del Microisis modificado y del Sistema de Información Bibliográfica de CEPAL para la Red IPALCA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Explica literales y comandos para espaciador horizontal y vertical y otros de los formatos de despliegue del mini-micro CDS/ISIS.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Contiene ayuda memoria para la exportación de una base, creación de archivo PAR, creación de subdirectorio y copia de archivos para lo cual se requiere tener instalado el Mini Micro ISIS versión 1.0 y 2.3 Red IPALCA.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Presenta los símbolos que se utilizan en la búsqueda de información en una base de datos, tanto las realizadas en el archivo invertido, como en búsquedas libres en el texto, con la indicación de la operación que cumplen y un ejemplo de uso.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Incluye Bibliografía

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Aim. This study aimed to observe the morphological and molecular effect of laminin-1 doping to nanostructured implant surfaces in a rabbit model. Materials and Methods. Nanostructured implants were coated with laminin-1 (test; dilution, 100 g/mL) and inserted into the rabbit tibiae. Noncoated implants were used as controls. After 2 weeks of healing, the implants were removed and subjected to morphological analysis using scanning electron microscopy (SEM) and gene expression analysis using the real-time reverse transcriptase-polymerase chain reaction (RT-PCR). Results. SEM revealed bony tissue attachment for both control and test implants. Real-time RT-PCR analysis showed that the expression of osteoblast markers RUNX-2, osteocalcin, alkaline phosphatase, and collagen I was higher (1.62-fold, 1.53-fold, 1.97-fold, and 1.04-fold, resp.) for the implants modified by laminin-1 relative to the control. All osteoclast markers investigated in the study presented higher expression on the test implants than controls as follows: tartrate-resistant acid phosphatase (1.67-fold), calcitonin receptor (1.35-fold), and ATPase (1.25-fold). The test implants demonstrated higher expression of inflammatory markers interleukin-10 (1.53-fold) and tumour necrosis factor-α (1.61-fold) relative to controls. Conclusion. The protein-doped surface showed higher gene expression of typical genes involved in the osseointegration cascade than the control surface. © 2012 Humberto Osvaldo Schwartz-Filho et al.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Low-level laser (LLL) has been used on peri-implant tissues for accelerating bone formation. However, the effect of one session of LLL in the strength of bone-implant interface during early healing process remains unclear. The present study aims to evaluate the removal torque of titanium implants irradiated with LLL during surgical preparation of implant bed, in comparison to non-irradiation. Sixty-four Wistar rats were used. Half of the animals were included in LLL group, while the other half remained as control. All animals had the tibia prepared with a 2 mm drill, and a titanium implant (2.2 × 4 mm) was inserted. Animals from LLL group were irradiated with laser (gallium aluminum arsenide), with a wavelength of 808 nm, a measured power output of 50 mW, to emit radiation in collimated beams (0.4 cm2), for 1 min and 23 s, and an energy density of 11 J/cm2. Two applications (22 J/cm 2) were performed immediately after bed preparation for implant installation. Flaps were sutured, and animals from both groups were sacrificed 7, 15, 30, and 45 days after implant installation, when load necessary for removing implant from bone was evaluated by using a torquimeter. In both groups, torque values tended to increase overtime; and at 30 and 45 days periods, values were statistically higher for LLL group in comparison to control (ANOVA test, p < 0.0001). Thus, it could be suggested that a single session of irradiation with LLL was beneficial to improve bone-implant interface strength, contributing to the osseointegration process. © 2012 Springer-Verlag London Ltd.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Objective: To compare immediate and staged approach implant placement in circumferential defects treated with deproteinized bovine bone mineral (DBBM); hidroxyapatite/tricalcium phosphate (HA/TP); autogenous bone (Ab); and coagulum (Cg); upon implant stability, osseointegration and alveolar crest maintenance. Materials and methods: Six dogs underwent extractions of lower premolars, bilaterally. Twelve weeks later four bone defects (6 mm wide/4 mm long) were drilled at one side and randomly filled with DBBM; HA/TP; Ab; and Cg, respectively, and left to heal (staged approach). Eight weeks later one implant (Osseospeed™, AstraTech) was placed in experimental sites. At the same session four defects were drilled on contra-lateral side and implants were inserted immediately after biomaterials grafting (immediate approach). Animals were euthanized 8 weeks later. Implant stability was measured by resonance frequency analysis (RFA) at installation and after sacrifice. Ground sections were prepared for bone contact (BIC); bone area (BA); distance implant shoulder-bone crest (IS-C); distance implant shoulder first bone contact (IS-B); and areas occupied by soft tissue. Results: The BA and BIC were superior in the staged approach. The Cg exhibited higher BIC and BA as compared with other materials at the total implant body (P = 0.004 and 0.012, respectively). The DBBM, HA/TP and Ab groups rendered similar BA and BIC. The immediate approach resulted in less crest resorption compared to staged approach. The biomaterials did not affect the IS-C and IS-B measurements. Particles area tended to be higher in DBBM group than HA/TP (P = 0.15), while soft tissue infiltrate was higher in DBBM group when used in the immediate approach (P = 0.04). The RFA indicated gain in stability in the staged approach (P = 0.002). The correlation test between RFA vs. BIC and BA demonstrated inferior stability for DBBM group in immediate approach (P = 0.01). Conclusions: Implants placed in healed defects resulted in better stability as a consequence of higher BIC and BA. The Cg alone rendered increased BIC compared to other materials in both approaches. Immediate approach should be preferable to staged approach in terms of alveolar crest maintenance. The BIC and BA values did not vary between micro and macro-threads in this experimental model. Implants installed in sites filled with DBBM in immediate approach were less stable. © 2011 John Wiley & Sons A/S.