943 resultados para Microneedle electrodes
Resumo:
The indiscriminate use of antibiotics in food-producing animals has received increasing attention as a contributory factor in the international emergence of antibiotic-resistant bacteria (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004). Numerous analytical methods for quantifying antibacterial residues in edible animal products have been developed over years (Woodward in Pesticide, veterinary and other residues in food, CRC Press, Boca Raton, 2004; Botsoglou and Fletouris in Handbook of food analysis, residues and other food component analysis, Marcel Dekker, Ghent, 2004). Being Amoxicillin (AMOX) one of those critical veterinary drugs, efforts have been made to develop simple and expeditious methods for its control in food samples. In literature, only one AMOX-selective electrode has been reported so far. In that work, phosphotungstate:amoxycillinium ion exchanger was used as electroactive material (Shoukry et al. in Electroanalysis 6:914–917, 1994). Designing new materials based on molecularly imprinted polymers (MIPs) which are complementary to the size and charge of AMOX could lead to very selective interactions, thus enhancing the selectivity of the sensing unit. AMOX-selective electrodes used imprinted polymers as electroactive materials having AMOX as target molecule to design a biomimetic imprinted cavity. Poly(vinyl chloride), sensors of methacrylic acid displayed Nernstian slopes (60.7 mV/decade) and low detection limits (2.9 × 10−5 mol/L). The potentiometric responses were not affected by pH within 4–5 and showed good selectivity. The electrodes were applied successfully to the analysis of real samples.
Resumo:
JORNADAS DE ELECTROQUÍMICA E INOVAÇÃO 2013
Resumo:
This work presents the development of a low cost sensor device for the diagnosis of breast cancer in point-of-care, made with new synthetic biomimetic materials inside plasticized poly(vinyl chloride), PVC, membranes, for subsequent potentiometric detection. This concept was applied to target a conventional biomarker in breast cancer: Breast Cancer Antigen (CA15-3). The new biomimetic material was obtained by molecularly-imprinted technology. In this, a plastic antibody was obtained by polymerizing around the biomarker that acted as an obstacle to the growth of the polymeric matrix. The imprinted polymer was specifically synthetized by electropolymerization on an FTO conductive glass, by using cyclic voltammetry, including 40 cycles within -0.2 and 1.0 V. The reaction used for the polymerization included monomer (pyrrol, 5.0×10-3 mol/L) and protein (CA15-3, 100U/mL), all prepared in phosphate buffer saline (PBS), with a pH of 7.2 and 1% of ethylene glycol. The biomarker was removed from the imprinted sites by proteolytic action of proteinase K. The biomimetic material was employed in the construction of potentiometric sensors and tested with regard to its affinity and selectivity for binding CA15-3, by checking the analytical performance of the obtained electrodes. For this purpose, the biomimetic material was dispersed in plasticized PVC membranes, including or not a lipophilic ionic additive, and applied on a solid conductive support of graphite. The analytical behaviour was evaluated in buffer and in synthetic serum, with regard to linear range, limit of detection, repeatability, and reproducibility. This antibody-like material was tested in synthetic serum, and good results were obtained. The best devices were able to detect 5 times less CA15-3 than that required in clinical use. Selectivity assays were also performed, showing that the various serum components did not interfere with this biomarker. Overall, the potentiometric-based methods showed several advantages compared to other methods reported in the literature. The analytical process was simple, providing fast responses for a reduced amount of analyte, with low cost and feasible miniaturization. It also allowed the detection of a wide range of concentrations, diminishing the required efforts in previous sample pre-treating stages.
Resumo:
III Jornadas de Electroquímica e Inovação (Electroquímica e Nanomateriais), na Universidade de Trás-os-Montes e Alto Douro, Vila Real, 16 a 17 de Setembro de 2013
Resumo:
Graduate Student Symposium on Molecular Imprinting 2013, na Queen’s University, Belfast, United Kingdom, 15 a 17 de Agosto de 2013
Resumo:
INTRODUCTION: Vagal activity is thought to influence atrial electrophysiological properties and play a role in the initiation and maintenance of atrial fibrillation (AF). In this study, we assessed the effects of acute vagal stimulation (vagus_stim) on atrial conduction times, atrial and pulmonary vein (PV) refractoriness, and vulnerability to induction of AF in the rabbit heart with intact autonomic innervation. METHODS: An open-chest epicardial approach was performed in 11 rabbits (New Zealand; 3.9-5.0 kg), anesthetized and artificially ventilated after neuromuscular blockade. A 3-lead ECG was obtained. Atrial electrograms were recorded along the atria, from right to left (four monopolar electrodes), together with a circular electrode adapted for proximal left PV assessment. Acute vagus nerve stimulation was obtained with bipolar electrodes (20 Hz). Epicardial activation was recorded in sinus rhythm, and the conduction time from right (RA) to left atrium (LA), and from RA to PVs, was measured in basal conditions and during vagus_stim. The atrial effective refractory period (ERP) and dispersion of refractoriness (Disp_A) were analyzed. Vulnerability to AF induction was assessed at the right (RAA) and left (LAA) atrial appendages and the PVs. Atrial stimulation (50 Hz) was performed alone or combined with vagus_stim. Heart rate and blood pressure were monitored. RESULTS: In basal conditions, there was a significant delay in conduction from RA to PVs, not influenced by vagus_stim, and the PV ERPs were shorter than those measured in LA and LAA, but without significant differences compared to RA and RAA. During vagus_stim, conduction times between RA and LA increased from 16+8 ms to 27+6 ms (p < 0.05) and ERPs shortened significantly in RA, LAA and LA (p < 0.05), but not in RAA. There were no significant differences in Disp_A. AF induction was reproducible in 45% of cases at 50 Hz and in 100% at 50 Hz+vagus_stim (p < 0.05). The duration of inducible AF increased from 1.0 +/- 0.2 s to 12.0 +/- 4.5 s with 50 Hz+vagus_stim (p < 0.01). AF lasted >10 s in 45.4% of rabbits during vagus_stim, and ceased after vagus_stim in 4 out of these 5 cases. In 3 animals, PV tachycardia, with fibrillatory conduction, induced with 50 Hz PV pacing during vagus_stim. CONCLUSIONS: Vagus_stim reduces interatrial conduction velocity and significantly shortens atrial ERP, contributing to the induction and duration of AF episodes in the in vivo rabbit heart. This model may be useful for the assessment of autonomic influence on the pathophysiology of AF.
Resumo:
Feldspato é o nome dado a uma importante família de minerais, do grupo dos tectossilicatos, que compõem o material rochoso de mais de 60% da crusta terrestre. Estes minerais são constituintes essenciais da maior parte das rochas cristalinas e a sua importância é tal que o seu estudo constitui um capítulo fundamental da petrografia. Dada a sua grande incidência na crusta terrestre, os feldspatos ocorrem em diversos cenários geológicos, desde os depósitos pegmatitos, aos aplitos, granitos, sienitos nefelínicos e ainda areias feldspáticas. As suas características químicas, físicas e mineralógicas fazem com que este grupo de minerais esteja presente nas mais diversificadas indústrias, tais como a vidreira, cerâmica, tintas, borrachas, plásticos, abrasivos ligeiros, elétrodos de soldadura, entre outros. Em Portugal, as principais unidades produtoras de feldspatos encontram‐se distribuídas pelo Norte e Centro do país, mais concretamente pelos distritos de Viana do Castelo, Braga, Vila Real, Porto, Viseu e Guarda. Novos estudos geológicos acompanhados de prospeções, nomeadamente na região do maciço central, têm sido efetuados com vista à descoberta de novos depósitos com potencial para exploração deste importante mineral. O depósito aplítico da Argemela, no concelho do Fundão apresenta‐se como um depósito cujas dimensões e qualidade apresentadas indicam a possibilidade de exploração. Nesse sentido, o presente trabalho consiste em analisar e caracterizar os materiais presentes na quele depósito mineral, tendo em vista a respectiva aplicação industrial, e posteriormente propor uma instalação de processamento do material para que o mesmo seja comercializado. Também será objeto deste trabalho a análise da viabilidade económica do projeto, mais concretamente fazendo a previsão do investimento inicial de modo a somar os custos de produção correntes e avaliar o retorno com base na comercialização do material no modo “Ex Works”.
Resumo:
A gold nanoparticle-coated screen-printed carbon electrode was used as the transducer in the development of an electrochemical immunosensor for Ara h 1 (a major peanut allergen) detection in food samples. Gold nanoparticles (average diameter=32 nm) were electrochemically generated on the surface of screen-printed carbon electrodes. Two monoclonal antibodies were used in a sandwich-type immunoassay and the antibody–antigen interaction was electrochemically detected through stripping analysis of enzymatically (using alkaline phosphatase) deposited silver. The total time of the optimized immunoassay was 3 h 50 min. The developed immunosensor allowed the quantification of Ara h 1 between 12.6 and 2000 ng/ml, with a limit of detection of 3.8 ng/ml, and provided precise (RSD <8.7%) and accurate (recovery >96.6%) results. The immunosensor was successfully applied to the analysis of complex food matrices (cookies and chocolate), being able to detect Ara h 1 in samples containing 0.1% of peanut.
Resumo:
Potentiometric detection with homemade polymeric membrane microelectrodes was coupled to a magnetic sandwich immunoassay for Salmonella typhimurium determination. Cadmium and sodium ion selective electrodes were used respectively as indicator and pseudo-reference electrodes and were prepared in pipette tips to allow potentiometric measurements in microliter sample volumes. In the proposed method, the concentration of S. typhimurium was proportional to the amount of cadmium released upon dissolution of a CdS nanoparticle labeled to the secondary detection antibody. The limit of detection was 2 cells per 100 μL. The immunomagnetic assay with potentiometric detection is suitable for sensitive and rapid (average total time per assay of 75 minutes) detection of S. typhimurium in milk samples. The proposed method is easy to perform, safe, sensitive, and low cost and has potential for in situ analysis.
Resumo:
A voltammetric biosensor for Ara h 6 (a peanut allergen) detection in food samples was developed. Gold nanoparticle-modified screen-printed carbon electrodes were used to develop a sandwich-type immunoassay using two-monoclonal antibodies. The antibody-antigen interaction was detected through the electrochemical detection of enzymatically deposited silver. The immunosensor presented a linear range between 1 and 100 ng/ml, as well as high precision (inter-day RSD ≤9.8 %) and accuracy (recoveries ≥96.7 %). The detection and quantification limits were 0.27 and 0.88 ng/ml, respectively. It was possible to detect small levels of Ara h 6 in complex food matrices.
Resumo:
Objective: To analyze the short- and long-term effects of microcurrent used with aerobic exercise on abdominal fat (visceral and subcutaneous). Methods: Forty-two female students from a university population were randomly assigned into five group: intervention group (IG) 1 (n=9), IG2 (n=9), IG3 (n=7), IG4 (n=8), and placebo group (PG) (n=9). An intervention program of 10 sessions encompassing microcurrent and aerobic exercise (performed with a cycloergometer) was applied in all groups, with slightly differences between them. In IG1 and IG2, microcurrent with transcutaneous electrodes was applied, with different frequency values; 30-minute exercise on the cycloergometer was subsequently performed. IG3 used the same protocol as IG1 but with different electrodes (percutaneous), while in IG4 the microcurrent was applied simultaneously with the cycloergometer exercise. Finally, the PG used the IG1 protocol but with the microcurrent device switched off. All groups were evaluated through ultrasound and abdominal perimeter measurement for visceral and subcutaneous abdominal fat assessment; through calipers for skinfolds measurement; through bioimpedance to evaluate weight, fat mass percentage, and muscular mass; and through blood analyses to measure cholesterol, triglyceride, and glucose levels. Results: After intervention sessions, visceral fat decreased significantly in IG1 compared with the PG. Subcutaneous fat was reduced significantly in all groups compared with the PG. After 4 weeks, almost all results were maintained. Conclusion: The addition of microcurrent to aerobic exercise may reduce fat more than does aerobic exercise alone.
Resumo:
Objective: Localizing epileptic foci in posterior brain epilepsy remains a difficult exercise in surgery for epilepsy evaluation. Neither clinical manifestations, neurological, EEG nor neuropsychological evaluations provide strong information about the area of onset, and fast spread of paroxysms often produces mixed features of occipital, temporal and parietal symptoms. We investigated the usefulness of the N170 event-related potential to map epileptic activity in these patients. Methods: A group of seven patients with symptomatic posterior cortex epilepsy were submitted to a high-resolution EEG (78 electrodes), with recordings of interictal spikes and face-evoked N170. Generators of spikes and N170 were localized by source analysis. Range of normal N170 asymmetry was determined in 30 healthy volunteers. Results: In 3 out of 7 patients the N170 inter-hemispheric asymmetry was outside control values. Those were the patients whose spike sources were nearest (within 3 cm) to the fusiform gyrus, while foci further away did not affect the N170 ratio. Conclusions: N170 event-related potential provides useful information about focal cortical dysfunction produced by epileptic foci located in the close neighborhood of the fusiform gyrus, but are unaffected by foci further away. Significance: The N170 evoked by faces can improve the epileptic foci localization in posterior brain epilepsy.
Resumo:
Dissertação para obtenção do Grau de Mestre em Biotecnologia
Resumo:
As células foto voltaicas orgânicas ou células de Gräetzel (depois do seu descobridor) são aparelhos para a colecta de energia solar que utilizam um semicondutor inorgânico e uma molécula orgânica. Dita molécula orgânica é capaz de excitar-se na presença de radiação electromagnética e ceder esta energia através da doação de electrões a este semicondutor. Embora estas estruturas e o seu processo de fabrico sejam relativamente pouco onerosas, o aproveitamento da energia solar é ainda muito baixo. Para além desta deficiência, os corantes sintéticos sofrem de “bleaching” ou então são reduzidos ou oxidados facilmente quando não conseguem transferir a energia que foi absorvida ou quando é difícil voltar ao estado original por dificuldades no completamento de circulação de electrões. Neste trabalho pretende-se então estudar o comportamento de moléculas e misturas complexas de moléculas com capacidade para serem excitadas pela luz solar. Como a dita xcitação promove a transferência de um electrão, este processo será seguido pela técnica de Voltametria cíclica. Como substâncias absorventes de luz utilizaremos compostos naturais (principalmente flavonóides) puros, ou então na forma de complexos naturais extraídos de algumas plantas. Estas misturas de corantes serão extractos aquosos (infusões) de casca de laranja e limão assim como extractos de folhas de cerejeira, com o objectivo de proporcionar lternativas aos flavonóides utilizados neste estudo. A caracterização voltamétrica desta célula é feita em diferentes formas de iluminação. Sobre a célula assim formada faz-se incidir rimeiro luz de lâmpadas fluorescentes, depois luz ultra violeta e por fim sem qualquer tipo de luz incidente. Na base do fabrico da variante mais clássica destas células está o semicondutor óxido de itânio (TiO2), por ser uma substância muito comum e barata e com propriedades semicondutoras notáveis. Uma forma comum de melhorar a eficiência deste material é introduzir dopantes com o intuito de melhorar a eficiência do processo de transferência electrónica. Um segundo objectivo deste trabalho é o estudo de sistemas semicondutor/molécula foto activa. Semicondutores como ZnO, TiO2 e TiO2 dopado serão então estudados. O gels de TiO2 ou o TiO2 dopado serão depositados sobre lâminas de vidro comum, nas quais foi anteriormente depositado uma película de alumínio que serve de condutor (eléctrodo egativo). Uma outra variante será a utilização de óxido de zinco, um semicondutor de baixo custo que por sua vez vai ser depositado em lâminas de alumínio comercial. A nossa célula foto electroquímica será então formada por moléculas de corante, uma lâmina e um semicondutor (que funcionará como eléctrodo de trabalho), com ou sem electrólito/catalizador (solução de iodo/iodeto), e eléctrodos de referência de Ag/AgCl, e outro auxiliar de grafite. Um outro objectivo é fazer um pequeno estudo sobre influencia do catalisador I2/etilenodiamina no comportamento electroquímico da célula, de forma a poder utilizar o solvente (etilenodiamina) com menor volatilidade do que a água, que é empregada no par I2/I3.m A importância deste facto prende-se com a limitada vida destas células quando o electrólito/solvente é evaporado pelas altas temperaturas da radiação incidente.
Resumo:
Esta dissertação tem como principal objetivo a criação de uma interface humana, baseada na eletromiografia dos músculos orbicular do olho e frontalis. O algoritmo de programação do microcontrolador ATmega2560 deteta o piscar de olhos voluntário, conta o número de vezes que este acontece e verifica se preenche os requisitos necessários à execução de um comando. Para este efeito foram utilizados elétrodos para a captação do sinal eletromiográfico. O sinal analógico é condicionado pela Shield ECG/EMG da Olimex sendo enviado para o arduíno ATmega2560. Este microcontrolador administra todos os atuadores, dos quais o mais importante é um painel de comandos (quatro comandos diferentes), no qual existe um ponteiro motorizado que indica qual a ação a realizar. O código de execução é extremamente simples: se o utilizador piscar os olhos três vezes, o ponteiro movimenta-se para a secção do painel imediatamente à direita; e se o utilizador piscar os olhos quatro vezes, o ponteiro movimenta-se para a secção do painel imediatamente à esquerda. Os testes realizados com este dispositivo indicam que os utilizadores demoram menos de 10 minutos a aprender a utilizar e executar todos os comandos do painel. Apenas num dos testes realizados o dispositivo não funcionou. Dos utilizadores que realizaram o teste: vários usam óculos; um idoso com graves problemas auditivos, cegueira parcial e dificuldades locomotoras; nenhum foi incapaz de piscar, pelo menos, um dos olhos voluntariamente; e a maioria referiu que, com alguma concentração e principalmente se ouvirem o bip sonoro, a aprendizagem de utilização torna-se muito fácil. Apesar dos limites impostos à concretização de um projeto deste tipo (dos quais se evidenciam as dificuldades em conseguir voluntários com paralisia medular, bem como os limites orçamentais), pode-se afirmar que este dispositivo é eficaz e seria uma mais valia quando implementado num cenário de paralisia medular (total ou parcial). A melhoria de qualidade de vida de um utilizador com estes problemas físicos, ou outros que lhe comprometam a locomoção é garantida. O cenário em que vivem é tremendamente limitado sendo urgente criar soluções para tornar estas vidas mais cómodas. Com os devidos aplicativos, o utilizador poderia abrir portas ou janelas, acender ou apagar luzes, pedir ajuda, ajustar a posição da cama, controlar cadeiras de rodas, entre outros. É neste sentido que surge a minha motivação de criar algo que ajude estas pessoas.