998 resultados para MR-RADIX


Relevância:

20.00% 20.00%

Publicador:

Resumo:

Pós-graduação em Ciência da Computação - IBILCE

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The Mr. USA Pageant Records consists of letters, news releases, newspaper clippings, memorabilia, and photographs relating to the operation of the pageant and the publicity generated from the pageant. The Mr. USA Pageant was held on May 13, 1977 in Charleston, SC as a spoof of traditional beauty pageants and was sponsored by the National Organization of Women (NOW).

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The aim of the present study was to investigate the relationship between degenerative bone changes of the head of the mandible and the presence of joint effusion (JE). This study was based on sagittal magnetic resonance imaging (MRI) reports of 148 temporomandibular joints (TMJs) of 74 patients complaining of pain and/or dysfunction in the TMJ area. The mandible heads were surveyed for osteoarthritis characteristics, which were classified as osteophytosis, sclerosis or erosion. The presence of JE was checked whenever high signal intensity was observed in the articular space. The results evidenced the presence of bone changes in 30% of the sample. Osteophytes and erosions were the changes most commonly observed. JE was reported in 10% of TMJs. The results from the statistical tests revealed that bone changes in the head of the mandible are associated with the presence of JE.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

My work is focused on George Friel, a distinguished Scottish writer known for his witty style bristling with puns and more or less literary allusions. In particular I proposed an annotated translation of what can be considered his masterpiece “Mr Alfred M.A.” in which wordplay has a central role for its plot. In the first part of my thesis I outlined the fundamental features of Friel’s writing: the wide variety of registers and styles, the rhythm and irony. Additionally I pointed out the strategies that the translator has to face when translating this text. Finally I identified the number of problems which may arise while translating Friel’s “Mr Alfred M.A.” into Italian with particular concern on the strategies of supplementation and explicitation for wordplay.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Zusammenfassung: Michael EbertEntwicklung eines leistungsstarken Polarisators und Kompressorsfür 3-He für medizinische MR Tomographie Durch Optisches Pumpen von metastabilem3-He*--Gas bei einem Druck von 1 mb und Spinübertrag mittels Metastabileraustauschstöße aufden Grundzustand, wird 3-He auf 53 % bei einemmittleren Fluß von f = 58 bar*liter/Tag aufpolarisiert. Bei einem Fluß von f = 122bar*l/Tag wird immer noch eine Polarisation von 30 % erzielt. DurchSteigerung der Laserleistung von derzeit 12 Watt aufwünschenswerte 30 Watt, könnten beigleichem Fluß Kernspinpolarisationen des Heliums von 70 % erreicht werden. Mittels einer eigens entwickelten Ganzmetall--Titan--Kolbenpumpeerfolgt die Kompression in zwei Stufen. Zuerst wird einZwischenvolumen auf Drücke 200 bis 800 mb,je nach Anwendung gefüllt. Mit dem selben Kompressor könnenanschließend abnehmbare, verschließbare Experimentierzellen ausdiesem Zwischenvolumen auf Drücke 1 bis 6 bar gefüllt werden. Auf Grund des großen Hubvolumens von 15,4 Liter können große Gasmengen proKompressionszyklus verdichtet werden. Wegen des großen Verhältnisaus Kompressionshub h = 100 cm undKompressordurchmesser 14 cm kommt es imKompressionsraum zu keinen meßbaren Polarisationsverlusten.Zusammen mit dem großen Kompressionsfaktor von K = 10000sind diese konstruktiven Maßnahmen für den vollständigen Erhaltder Polarisation bei der Kompression des polarizierten 3-He--Gasesverantwortlich. Diese großen Gasmengen an hyperpolarisiertem 3-He haben ersteklinische Studien funktioneller Lungen--MRT ermöglicht. DurchMessung des Sauerstoffpartialdrucks und dessen Abnahmerate, derBestimmung der Ventillation und Messung der DiffusionskonstantenADC in der Lunge, können die Funktionen dieses Organs lokalquantitativ beurteilt werden.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

The diagnosis, grading and classification of tumours has benefited considerably from the development of DCE-MRI which is now essential to the adequate clinical management of many tumour types due to its capability in detecting active angiogenesis. Several strategies have been proposed for DCE-MRI evaluation. Visual inspection of contrast agent concentration curves vs time is a very simple yet operator dependent procedure, therefore more objective approaches have been developed in order to facilitate comparison between studies. In so called model free approaches, descriptive or heuristic information extracted from time series raw data have been used for tissue classification. The main issue concerning these schemes is that they have not a direct interpretation in terms of physiological properties of the tissues. On the other hand, model based investigations typically involve compartmental tracer kinetic modelling and pixel-by-pixel estimation of kinetic parameters via non-linear regression applied on region of interests opportunely selected by the physician. This approach has the advantage to provide parameters directly related to the pathophysiological properties of the tissue such as vessel permeability, local regional blood flow, extraction fraction, concentration gradient between plasma and extravascular-extracellular space. Anyway, nonlinear modelling is computational demanding and the accuracy of the estimates can be affected by the signal-to-noise ratio and by the initial solutions. The principal aim of this thesis is investigate the use of semi-quantitative and quantitative parameters for segmentation and classification of breast lesion. The objectives can be subdivided as follow: describe the principal techniques to evaluate time intensity curve in DCE-MRI with focus on kinetic model proposed in literature; to evaluate the influence in parametrization choice for a classic bi-compartmental kinetic models; to evaluate the performance of a method for simultaneous tracer kinetic modelling and pixel classification; to evaluate performance of machine learning techniques training for segmentation and classification of breast lesion.

Relevância:

20.00% 20.00%

Publicador:

Resumo:

Il cancro della prostata (PCa) è il tumore maligno non-cutaneo più diffuso tra gli uomini ed è il secondo tumore che miete più vittime nei paesi occidentali. La necessità di nuove tecniche non invasive per la diagnosi precoce del PCa è aumentata negli anni. 1H-MRS (proton magnetic resonance spectroscopy) e 1H-MRSI (proton magnetic resonance spectroscopy imaging) sono tecniche avanzate di spettroscopia in risonanza magnetica che permettono di individuare presenza di metaboliti come citrato, colina, creatina e in alcuni casi poliammine in uno o più voxel nel tessuto prostatico. L’abbondanza o l’assenza di uno di questi metaboliti rende possibile discriminare un tessuto sano da uno patologico. Le tecniche di spettroscopia RM sono correntemente utilizzate nella pratica clinica per cervello e fegato, con l’utilizzo di software dedicati per l’analisi degli spettri. La quantificazione di metaboliti nella prostata invece può risultare difficile a causa del basso rapporto segnale/rumore (SNR) degli spettri e del forte accoppiamento-j del citrato. Lo scopo principale di questo lavoro è di proporre un software prototipo per la quantificazione automatica di citrato, colina e creatina nella prostata. Lo sviluppo del programma e dei suoi algoritmi è stato portato avanti all’interno dell’IRST (Istituto Romagnolo per lo Studio e la cura dei Tumori) con l’aiuto dell’unità di fisica sanitaria. Il cuore del programma è un algoritmo iterativo per il fit degli spettri che fa uso di simulazioni MRS sviluppate con il pacchetto di librerie GAMMA in C++. L’accuratezza delle quantificazioni è stata testata con dei fantocci realizzati all’interno dei laboratori dell’istituto. Tutte le misure spettroscopiche sono state eseguite con il nuovo scanner Philips Ingenia 3T, una delle machine di risonanza magnetica più avanzate per applicazioni cliniche. Infine, dopo aver eseguito i test in vitro sui fantocci, sono stati acquisiti gli spettri delle prostate di alcuni volontari sani, per testare se il programma fosse in grado di lavorare in condizioni di basso SNR.