929 resultados para Low weight
Resumo:
Components of high molecular-weight (PI) obtained from Ascaris suum extract down-regulate the Th1/Th2-related immune responses induced by ovalbumin (OVA)-immunization in mice. Furthermore, the PI down-modulates the ability of dendritic cells (DCs) to activate T lymphocytes by an IL-10-mediated mechanism. Here, we evaluated the role of toll like receptors 2 and 4 (TLR2 and 4) in the modulatory effect of PI on OVA-specific immune response and the PI interference on DC full activation. An inhibition of OVA-specific cellular and humoral responses were observed in wild type (WT) or in deficient in TLR2 (TLR2(-/-)) or 4 (TLR4(-/-)) mice immunized with OVA plus PI when compared with OVA-immunized mice. Low expression of class II MHC, CD40, CD80 and CD86 molecules was observed in lymph node (LN) cells from WT, TLR2(-/-) or TLR4(-/-) mice immunized with OVA plus PI compared with OVA-primed cells. We also verified that PI was able to modulate the activation of DCs derived from bone marrow of WT, TLR2(-/-) or TLR4(-/-) mice induced in vitro by agonists of TLRs, as observed by a decreased expression of class II MHC and costimulatory molecules and by low secretion of pro-inflammatory cytokines. Its effect was accompanied by IL-10 synthesis. In this sense, the modulatory effect of PI on specific-immune response and DC activation is independent of TLR2 or TLR4.
Resumo:
In der vorliegenden Arbeit wurden Struktur-Eigenschaftsbeziehungen des konjugierten Modell-Polymers MEH-PPV untersucht. Dazu wurde Fällungs-fraktionierung eingesetzt, um MEH-PPV mit unterschiedlichem Molekulargewicht (Mw) zu erhalten, insbesondere MEH-PPV mit niedrigem Mw, da dieses für optische Wellenleiterbauelemente optimal geeignet ist Wir konnten feststellen, dass die Präparation einer ausreichenden Menge von MEH-PPV mit niedrigem Mw und geringer Mw-Verteilung wesentlich von der geeigneten Wahl des Lösungsmittels und der Temperatur während der Zugabe des Fällungsmittels abhängt. Alternativ dazu wurden UV-induzierte Kettenspaltungseffekte untersucht. Wir folgern aus dem Vergleich beider Vorgehensweisen, dass die Fällungsfraktionierung verglichen mit der UV-Behandlung besser geeignet ist zur Herstellung von MEH-PPV mit spezifischem Mw, da das UV-Licht Kettendefekte längs des Polymerrückgrats erzeugt. 1H NMR and FTIR Spektroskopie wurden zur Untersuchung dieser Kettendefekte herangezogen. Wir konnten außerdem beobachten, dass die Wellenlängen der Absorptionsmaxima der MEH-PPV Fraktionen mit der Kettenlänge zunehmen bis die Zahl der Wiederholeinheiten n 110 erreicht ist. Dieser Wert ist signifikant größer als früher berichtet. rnOptische Eigenschaften von MEH-PPV Wellenleitern wurden untersucht und es konnte gezeigt werden, dass sich die optischen Konstanten ausgezeichnet reproduzieren lassen. Wir haben die Einflüsse der Lösungsmittel und Temperatur beim Spincoaten auf Schichtdicke, Oberflächenrauigkeit, Brechungsindex, Doppelbrechung und Wellenleiter-Dämpfungsverlust untersucht. Wir fanden, dass mit der Erhöhung der Siedetemperatur der Lösungsmittel die Schichtdicke und die Rauigkeit kleiner werden, während Brechungsindex, Doppelbrechung sowie Wellenleiter-Dämpfungsverluste zunahmen. Wir schließen daraus, dass hohe Siedetemperaturen der Lösungsmittel niedrige Verdampfungsraten erzeugen, was die Aggregatbildung während des Spincoatings begünstigt. Hingegen bewirkt eine erhöhte Temperatur während der Schichtpräparation eine Erhöhung von Schichtdicke und Rauhigkeit. Jedoch nehmen Brechungsindex und der Doppelbrechung dabei ab.rn Für die Schichtpräparation auf Glassubstraten und Quarzglas-Fasern kam das Dip-Coating Verfahren zum Einsatz. Die Schichtdicke der Filme hängt ab von Konzentration der Lösung, Transfergeschwindigkeit und Immersionszeit. Mit Tauchbeschichtung haben wir Schichten von MEH-PPV auf Flaschen-Mikroresonatoren aufgebracht zur Untersuchung von rein-optischen Schaltprozessen. Dieses Verfahren erweist sich insbesondere für MEH-PPV mit niedrigem Mw als vielversprechend für die rein-optische Signalverarbeitung mit großer Bandbreite.rn Zusätzlich wurde auch die Morphologie dünner Schichten aus anderen PPV-Derivaten mit Hilfe von FTIR Spektroskopie untersucht. Wir konnten herausfinden, dass der Alkyl-Substitutionsgrad einen starken Einfluss auf die mittlere Orientierung der Polymerrückgrate in dünnen Filmen hat.rn
Resumo:
Low back pain is associated with plasticity changes and central hypersensitivity in a subset of patients. We performed a case-control study to explore the discriminative ability of different quantitative sensory tests in distinguishing between 40 cases with chronic low back pain and 300 pain-free controls, and to rank these tests according to the extent of their association with chronic pain. Gender, age, height, weight, body mass index, and psychological measures were recorded as potential confounders. We used 26 quantitative sensory tests, including different modalities of pressure, heat, cold, and electrical stimulation. As measures of discrimination, we estimated receiver operating characteristics (ROC) and likelihood ratios. Six tests seemed useful (in order of their discriminative ability): (1) pressure pain detection threshold at the site of most severe pain (fitted area under the ROC, 0.87), (2) single electrical stimulation pain detection threshold (0.87), (3) single electrical stimulation reflex threshold (0.83), (4) pressure pain tolerance threshold at the site of most severe pain (0.81), (5) pressure pain detection threshold at suprascapular region (0.80), and (6) temporal summation pain threshold (0.80). Pressure and electrical pain modalities seemed most promising and may be used for diagnosis of pain hypersensitivity and potentially for identifying individuals at risk of developing chronic low back pain over time.
Resumo:
OBJECTIVE: Adiponectin has anti-atherogenic properties and low circulating adiponectin has been linked to coronary atherosclerosis. Yet, there is considerable evidence that the high-molecular weight (HMW) complex of adiponectin is the major active form of this adipokine. We therefore investigated whether HMW adiponectin is associated with the extent of coronary artery disease (CAD) in men. RESEARCH DESIGN AND METHODS: Associations among CAD, HMW adiponectin and the HMW/total-adiponectin ratio were assessed in 240 male patients undergoing elective coronary angiography. Total adiponectin and HMW adiponectin was measured by enzyme-linked immunosorbent assay and serum levels were correlated with defined coronary scores and established cardiovascular risk factors. RESULTS: We found significant inverse correlations between angiographic scores and HMW adiponectin [Extent Score (ES): r=-0.39; Gensini Score (GS): r=-0.35; and Severity Score (SS): r=-0.40, all P<0.001], and the HMW/total-adiponectin ratio (ES: r=-0.49; GS: r=-0.46; SS: r=-0.46; all P<0.001). Multivariable regression analyses revealed that HMW adiponectin and the HMW/total-adiponectin ratio were significantly associated with the extent of CAD (both P<0.001). ROC analyses demonstrated that the predictive value of HMW adiponectin and the HMW/total-adiponectin ratio for the extent of coronary atherosclerosis significantly exceeded that of total adiponectin (P<0.001, P=0.010, respectively). CONCLUSIONS: HMW adiponectin and the HMW/total-adiponectin ratio inversely correlate with the extent of CAD. HMW adiponectin in particular seems to be a better marker for CAD extent than total adiponectin.
Resumo:
This study will look at the passenger air bag (PAB) performance in a fix vehicle environment using Partial Low Risk Deployment (PLRD) as a strategy. This development will follow test methods against actual baseline vehicle data and Federal Motor Vehicle Safety Standards 208 (FMVSS 208). FMVSS 208 states that PAB compliance in vehicle crash testing can be met using one of three deployment methods. The primary method suppresses PAB deployment, with the use of a seat weight sensor or occupant classification sensor (OCS), for three-year old and six-year old occupants including the presence of a child seat. A second method, PLRD allows deployment on all size occupants suppressing only for the presents of a child seat. A third method is Low Risk Deployment (LRD) which allows PAB deployment in all conditions, all statures including any/all child seats. This study outlines a PLRD development solution for achieving FMVSS 208 performance. The results of this study should provide an option for system implementation including opportunities for system efficiency and other considerations. The objective is to achieve performance levels similar too or incrementally better than the baseline vehicles National Crash Assessment Program (NCAP) Star rating. In addition, to define systemic flexibility where restraint features can be added or removed while improving occupant performance consistency to the baseline. A certified vehicles’ air bag system will typically remain in production until the vehicle platform is redesigned. The strategy to enable the PLRD hypothesis will be to first match the baseline out of position occupant performance (OOP) for the three and six-year old requirements. Second, improve the 35mph belted 5th percentile female NCAP star rating over the baseline vehicle. Third establish an equivalent FMVSS 208 certification for the 25mph unbelted 50th percentile male. FMVSS 208 high-speed requirement defines the federal minimum crash performance required for meeting frontal vehicle crash-test compliance. The intent of NCAP 5-Star rating is to provide the consumer with information about crash protection, beyond what is required by federal law. In this study, two vehicles segments were used for testing to compare and contrast to their baseline vehicles performance. Case Study 1 (CS1) used a cross over vehicle platform and Case Study 2 (CS2) used a small vehicle segment platform as their baselines. In each case study, the restraints systems were from different restraint supplier manufactures and each case contained that suppliers approach to PLRD. CS1 incorporated a downsized twins shaped bag, a carryover inflator, standard vents, and a strategic positioned bag diffuser to help disperse the flow of gas to improve OOP. The twin shaped bag with two segregated sections (lobes) to enabled high-speed baseline performance correlation on the HYGE Sled. CS2 used an A-Symmetric (square shape) PAB with standard size vents, including a passive vent, to obtain OOP similar to the baseline. The A-Symmetric shape bag also helped to enabled high-speed baseline performance improvements in HYGE Sled testing in CS2. The anticipated CS1 baseline vehicle-pulse-index (VPI) target was in the range of 65-67. However, actual dynamic vehicle (barrier) testing was overshadowed with the highest crash pulse from the previous tested vehicles with a VPI of 71. The result from the 35mph NCAP Barrier test was a solid 4-Star (4.7 Star) respectfully. In CS2, the vehicle HYGE Sled development VPI range, from the baseline was 61-62 respectively. Actual NCAP test produced a chest deflection result of 26mm versus the anticipated baseline target of 12mm. The initial assessment of this condition was thought to be due to the vehicles significant VPI increase to 67. A subsequent root cause investigation confirmed a data integrity issue due to the instrumentation. In an effort to establish a true vehicle test data point a second NCAP test was performed but faced similar instrumentation issues. As a result, the chest deflect hit the target of 12.1mm; however a femur load spike, similar to the baseline, now skewed the results. With noted level of performance improvement in chest deflection, the NCAP star was assessed as directional for 5-Star capable performance. With an actual rating of 3-Star due to instrumentation, using data extrapolation raised the ratings to 5-Star. In both cases, no structural changes were made to the surrogate vehicle and the results in each case matched their perspective baseline vehicle platforms. These results proved the PLRD is viable for further development and production implementation.
Resumo:
In a relatively short period of sixty-five years, aluminum has grown to the rank of fifth in total weight of metals produced in the world. Throughout its short life, aluminum has been found to have excellent corrosion-resistant properties; yet only in recent years has aluminum been under consideration as a corrosion-resistant coating for iron and steel.
Resumo:
BACKGROUND Preterm birth, low birth weight, and infant catch-up growth seem associated with an increased risk of respiratory diseases in later life, but individual studies showed conflicting results. OBJECTIVES We performed an individual participant data meta-analysis for 147,252 children of 31 birth cohort studies to determine the associations of birth and infant growth characteristics with the risks of preschool wheezing (1-4 years) and school-age asthma (5-10 years). METHODS First, we performed an adjusted 1-stage random-effect meta-analysis to assess the combined associations of gestational age, birth weight, and infant weight gain with childhood asthma. Second, we performed an adjusted 2-stage random-effect meta-analysis to assess the associations of preterm birth (gestational age <37 weeks) and low birth weight (<2500 g) with childhood asthma outcomes. RESULTS Younger gestational age at birth and higher infant weight gain were independently associated with higher risks of preschool wheezing and school-age asthma (P < .05). The inverse associations of birth weight with childhood asthma were explained by gestational age at birth. Compared with term-born children with normal infant weight gain, we observed the highest risks of school-age asthma in children born preterm with high infant weight gain (odds ratio [OR], 4.47; 95% CI, 2.58-7.76). Preterm birth was positively associated with an increased risk of preschool wheezing (pooled odds ratio [pOR], 1.34; 95% CI, 1.25-1.43) and school-age asthma (pOR, 1.40; 95% CI, 1.18-1.67) independent of birth weight. Weaker effect estimates were observed for the associations of low birth weight adjusted for gestational age at birth with preschool wheezing (pOR, 1.10; 95% CI, 1.00-1.21) and school-age asthma (pOR, 1.13; 95% CI, 1.01-1.27). CONCLUSION Younger gestational age at birth and higher infant weight gain were associated with childhood asthma outcomes. The associations of lower birth weight with childhood asthma were largely explained by gestational age at birth.
Resumo:
BACKGROUND Lead exposure is associated with low birth-weight. The objective of this study is to determine whether lead exposure is associated with lower body weight in children, adolescents and adults. METHODS We analyzed data from NHANES 1999-2006 for participants aged ≥3 using multiple logistic and multivariate linear regression. Using age- and sex-standardized BMI Z-scores, overweight and obese children (ages 3-19) were classified by BMI ≥85 th and ≥95 th percentiles, respectively. The adult population (age ≥20) was classified as overweight and obese with BMI measures of 25-29.9 and ≥30, respectively. Blood lead level (BLL) was categorized by weighted quartiles. RESULTS Multivariate linear regressions revealed a lower BMI Z-score in children and adolescents when the highest lead quartile was compared to the lowest lead quartile (β (SE)=-0.33 (0.07), p<0.001), and a decreased BMI in adults (β (SE)=-2.58 (0.25), p<0.001). Multiple logistic analyses in children and adolescents found a negative association between BLL and the percentage of obese and overweight with BLL in the highest quartile compared to the lowest quartile (OR=0.42, 95% CI: 0.30-0.59; and OR=0.67, 95% CI: 0.52-0.88, respectively). Adults in the highest lead quartile were less likely to be obese (OR=0.42, 95% CI: 0.35-0.50) compared to those in the lowest lead quartile. Further analyses with blood lead as restricted cubic splines, confirmed the dose-relationship between blood lead and body weight outcomes. CONCLUSIONS BLLs are associated with lower body mass index and obesity in children, adolescents and adults.
Resumo:
BACKGROUND: There is a continuous debate regarding the best bottle nipple to be used to enhance the bottle-feeding performance of a preterm infant. Aim: To verify that feeding performance can be improved by using the bottle nipple with the physical characteristics that enhance infants' sucking skills. METHODS: Ten "healthy" VLBW infants (941+/-273 g) were recruited. Feeding performance was monitored at two time periods, when taking 1-2 and 6-8 oral feedings/d. At each time and within 24 h, performance was monitored using three different bottle nipples offered in a randomized order. Rate of milk transfer (ml/min) was the primary outcome measure. The sucking skills monitored comprised stage of sucking, suction amplitude, and duration of the generated negative intraoral suction pressure. RESULTS: At both times, infants demonstrated a similar rate of milk transfer among all three nipples. However, the stage of sucking, suction amplitude, and duration of the generated suction were significantly different between nipples at 1-2, but not 6-8 oral feedings/d.CONCLUSION: We did not identify a particular bottle nipple that enhanced bottle feeding in healthy VLBW infants. Based on the notion that afferent sensory feedback may allow infants to adapt to changing conditions, we speculate that infants can modify their sucking skills in order to maintain a rate of milk transfer that is appropriate with the level of suck-swallow-breathe coordination achieved at a particular time. Therefore, it is proposed that caretakers should be more concerned over monitoring the coordination of suck-swallow-breathe than over the selection of bottle nipples.
Resumo:
OBJECTIVE: (1) To compare maternal characteristics and psychological stress profile among African-American, Caucasian and Hispanic mothers who delivered very low birthweight infants. (2) To investigate associations between psychosocial factors, frequency of milk expression, skin-to-skin holding (STS), and lactation performance, defined as maternal drive to express milk and milk volume. STUDY DESIGN: Self-reported psychological questionnaires were given every 2 weeks after delivery over 10 weeks. Milk expression frequency, STS, and socioeconomic variables were collected. RESULT: Infant birthweight, education, and milk expression frequency differed between groups. Trait anxiety, depression and parental stress in a neonatal intensive care unit (PSS:NICU) were similar. African-American and Caucasian mothers reported the lowest scores in state anxiety and social desirability, respectively. Maternal drive to express milk, measured by maintenance of milk expression, correlated negatively with parental role alteration (subset of PSS:NICU) and positively with infant birthweight and STS. Milk volume correlated negatively with depression and positively with milk expression frequency and STS. CONCLUSION: Differences between groups were observed for certain psychosocial factors. The response bias to self-reported questionnaires between groups may not provide an accurate profile of maternal psychosocial profile. With different factors correlating with maintenance of milk expression and milk volume, lactation performance can be best enhanced with a multi-faceted intervention program, incorporating parental involvement in infant care, close awareness and management of maternal mental health, and encouragement for frequent milk expression and STS.
Resumo:
BACKGROUND: Adults use the Internet for weight loss information, sometimes by participating in discussion forums. Our purpose was to analyze the quality of advice exchanged on these forums. METHODS: This was a retrospective analysis of messages posted to 18 Internet weight loss forums during 1 month in 2006. Advice was evaluated for congruence with clinical guidelines; potential for causing harm; and subsequent correction when it was contradictory to guidelines (erroneous) or potentially harmful. Message- and forum-specific characteristics were evaluated as predictors of advice quality and self-correction. RESULTS: Of 3368 initial messages, 266 (7.9%) were requests for advice. Of 654 provisions of advice, 56 (8.6%) were erroneous and 19 of these 56 (34%) were subsequently corrected. Forty-three (6.6%) provisions of advice were harmful, and 12 of these 43 (28%) were subsequently corrected. Messages from low-activity forums (fewer messages) were more likely than those from high-activity forums to be erroneous (10.6% vs 2.4%, P < .001) or harmful (8.4% vs 1.2%, P < .001). In high-activity forums, 2 of 4 (50%) erroneous provisions of advice and 2 of 2 (100%) potentially harmful provisions of advice were corrected by subsequent postings. Compared with general weight loss advice, medication-related advice was more likely to be erroneous (P = .02) or harmful (P = .01). CONCLUSIONS: Most advice posted on highly active Internet weight loss forums is not erroneous or harmful. However, clinical and research strategies are needed to address the quality of medication-related advice.
Resumo:
BACKGROUND: Adults use the Internet for weight loss information, sometimes by participating in discussion forums. Our purpose was to analyze the quality of advice exchanged on these forums. METHODS: This was a retrospective analysis of messages posted to 18 Internet weight loss forums during 1 month in 2006. Advice was evaluated for congruence with clinical guidelines; potential for causing harm; and subsequent correction when it was contradictory to guidelines (erroneous) or potentially harmful. Message- and forum-specific characteristics were evaluated as predictors of advice quality and self-correction. RESULTS: Of 3368 initial messages, 266 (7.9%) were requests for advice. Of 654 provisions of advice, 56 (8.6%) were erroneous and 19 of these 56 (34%) were subsequently corrected. Forty-three (6.6%) provisions of advice were harmful, and 12 of these 43 (28%) were subsequently corrected. Messages from low-activity forums (fewer messages) were more likely than those from high-activity forums to be erroneous (10.6% vs 2.4%, P < .001) or harmful (8.4% vs 1.2%, P < .001). In high-activity forums, 2 of 4 (50%) erroneous provisions of advice and 2 of 2 (100%) potentially harmful provisions of advice were corrected by subsequent postings. Compared with general weight loss advice, medication-related advice was more likely to be erroneous (P = .02) or harmful (P = .01). CONCLUSIONS: Most advice posted on highly active Internet weight loss forums is not erroneous or harmful. However, clinical and research strategies are needed to address the quality of medication-related advice.
Resumo:
A cohort study study design was used to study the relationship of maternal low birthweight and infant low birthweight among African American women delivering full term infants. The cohort consisted of 3,157 mother-infant pairs drawn from the 1988 National Maternal and Infant Health Survey conducted by the National Center for Health Statistics. The objectives of the study were (1) to determine if low birthweight, African American mothers delivering term infants experienced higher rates of infant low birthweight and (2) to examine the role of selected contributory variables in the relationship of maternal low birthweight and infant low birthweight. Contributory risk factors examined included maternal marital status, maternal age, maternal education, maternal height, maternal prepregnant weight, birth order, history of a prior low birthweight delivery, timing of prenatal care, number of prenatal visits, gestational length, infant gender, and behavioral factors of smoking, alcohol, and illicit drug use during pregnancy.^ Using logistic regression analysis, risk of infant low birthweight among maternal low birthweight mothers increased after controlling for less than a high school education, less than 20 years of age, prepregnant weight less than 100 lbs, history of a prior low birthweight delivery, birth order, smoking during pregnancy, and use of alcohol and illicit drugs during pregnancy, but was not statistically significant. Loss of statistical significance was attributed to a large reduction in cases available for analysis after including illicit drug use in the model.^ This study demonstrated a consistent pattern of increased rates of infant low birthweight among low birthweight mothers. The force of history remains, hence women with this trait should be carefully monitored and advised during pregnancy to decrease risk of a low birthweight infant, in order to decrease the chain of events leading to future generations of low birthweight mothers. ^
Resumo:
AIM To compare treatment strategies for respiratory failure in extremely low birth weight (ELBW) infants in Germany in 1997 to Germany, Austria and Switzerland in 2011. METHODS A detailed questionnaire about treatment strategies for ELBW infants was sent to all German centres treating ELBW infants in 1997. A follow-up survey was conducted in 2011 in Germany, Austria and Switzerland. RESULTS In 1997 and 2011, 63.6% and 66.2% of the hospitals responded. In 2011 the response rate was higher in Switzerland than in Germany, and in university hospitals versus non-university hospitals. Treatment strategies did not differ between university and non-university hospitals as well as NICUs of different sizes in 2011. Differences between Germany, Austria and Switzerland were minimal. Administration of caffeine increased significantly, whereas theophylline and doxapram declined (all p<0.001). While the use of dexamethasone decreased and the use of hydrocortisone increased, the overall use of corticosteroids declined (all p<0.001). Between 1997 and 2011 therapy with inhalations and mucolytics decreased (both p<0.001) whereas the use application of diuretics did not change significantly. In mechanically ventilated infants the application of muscle relaxants and sedation declined significantly (p=0.009 and p<0.001), whereas analgesia use did not change. CONCLUSION Treatment strategies for respiratory failure in ELBW infants have changed significantly between 1997 and 2011. This article is protected by copyright. All rights reserved.
Resumo:
OBJECTIVES To find a threshold body weight (BW) below 100 kg above which computed tomography pulmonary angiography (CTPA) using reduced radiation and a reduced contrast material (CM) dose provides significantly impaired quality and diagnostic confidence compared with standard-dose CTPA. METHODS In this prospectively randomised study of 501 patients with suspected pulmonary embolism and BW <100 kg, 246 were allocated into the low-dose group (80 kVp, 75 ml CM) and 255 into the normal-dose group (100 kVp, 100 ml CM). Contrast-to-noise ratio (CNR) in the pulmonary trunk was calculated. Two blinded chest radiologists independently evaluated subjective image quality and diagnostic confidence. Data were compared between the normal-dose and low-dose groups in five BW subgroups. RESULTS Vessel attenuation did not differ between the normal-dose and low-dose groups within each BW subgroup (P = 1.0). The CNR was higher with the normal-dose compared with the low-dose protocol (P < 0.006) in all BW subgroups except for the 90-99 kg subgroup (P = 0.812). Subjective image quality and diagnostic confidence did not differ between CT protocols in all subgroups (P between 0.960 and 1.0). CONCLUSIONS Subjective image quality and diagnostic confidence with 80 kVp CTPA is not different from normal-dose protocol in any BW group up to 100 kg. KEY POINTS • 80 kVp CTPA is safe in patients weighing <100 kg • Reduced radiation and iodine dose still provide high vessel attenuation • Image quality and diagnostic confidence with low-dose CTPA is good • Diagnostic confidence does not deteriorate in obese patients weighing <100 kg.