957 resultados para Light emitting diode
Resumo:
The purpose of this study was to evaluate the effect of pre-heating resin composite photo-cured with light-curing units (LCU) by FT-IR. Twenty specimens were made in a metallic mold (4 mm diameter × 2 mm thick) from composite resin-Tetric Ceram® (Ivoclar/Vivadent) at room temperature (25°C) and pre-heated to 37, 54, and 60°C. The specimens were cured with halogen curing light (QTH) and light emitted by diodes (LED) during 40 s. Then, the specimens were pulverized, pressed with KBr and analyzed with FT-IR. The data were submitted to statistical analysis of variance and Kruskal-Wallis test. Study data showed no statistically significant difference to the degree of conversion for the different light curing units (QTH and LED) (p > 0.05). With the increase of temperature there was significant increase in the degree of conversion (p < 0.05). In this study were not found evidence that the light curing unit and temperature influenced the degree of conversion. © 2010 Pleiades Publishing, Ltd.
Resumo:
This study measured the critical temperature reaching time and also the variation of temperature in the surface of the cervical region and within the pulp chamber of human teeth submitted to dental bleaching using 35% hydrogen peroxide gel activated by three different light sources. The samples were randomly divided into 3 groups (n = 15), according to the catalyst light source: Halogen Light (HL), High Intensity Diode Laser (DL), and Light Emmited Diode (LED). The results of temperature variation were submitted to the analysis of variance and Tukey test with p < 0.05. The temperature increase (mean value and standard deviation) inside the pulp chamber for the HL group was 6.8 ± 2.8°C; for the DL group was 15.3 ± 8.8°C; and for the LED group was 1.9 ± 1.0°C for. The temperature variation (mean value and standard deviation) on the tooth surface, for the group irradiated with HL was 9.1 ± 2.2°C; for the group irradiated with DL were 25.7 ± 18.9°C; and for the group irradiated with LED were 2.6 ± 1.4°C. The mean temperature increase values were significantly higher for the group irradiated with DL when compared with groups irradiated with HL and LED (p < 0.05). When applying the inferior limits of the interval of confidence of 95%, an application time of 38.7 s was found for HL group, and 4.4 s for DL group. The LED group did not achieve the critical temperatures for pulp or the periodontal, even when irradiated for 360 s. The HL and DL light sources may be used for dental bleaching for a short period of time. The LED source did not heat the target tissues significantly within the parameters used in this study. © 2010 Pleiades Publishing, Ltd.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
Fundação de Amparo à Pesquisa do Estado de São Paulo (FAPESP)
Resumo:
Neste trabalho reportamos a investigação teórica da solvatação dos isômeros do tris- (8-idroxiquinolinolato) de alumínio III – Alq3, as propriedades eletroluminescentes na solvatação de Alq3 em líquidos orgânicos como metanol, etanol, dimetilformamida (DMF) e acetonitrila, a fim de se entender a dependência na variação de ambientes do sistema, aperfeiçoando o funcionamento de filmes transportadores em dispositivos eletroluminescentes do tipo OLED (Organic Light-Emitting Diodes) e por fim investigamos o mecanismo do transporte eletrônico no Alq3 aplicando uma baixa corrente elétrica na molécula e evidenciando as curvas corrente-voltagem característica do dispositivo. A simulação consiste na aplicação do método sequencial Monte Carlo / Mecânica quântica (S-MC/MQ), que parte de um tratamento inicial estocástico para separação das estruturas mais prováveis de menor energia e posteriormente com um tratamento quântico para plotar os espectros eletrônicos das camadas de solvatação separadas através do método ZINDOS/S. Nas propriedades elétricas do transporte utilizamos o método da função de Green de não equilíbrio acoplado a teoria do funcional densidade (DFT) inferindo que as ramificações mais externas correspondentes aos anéis no Alq3 seriam terminais para o translado eletrônico. Nossos resultados mostraram que a média dos espectros de absorção para solvatação do Alq3 em soluções sofre um desvio mínimo com a mudança de ambiente, estando em ótimo acordo com os resultados experimentais da literatura; e as curvas I-V confirmaram o comportamento diodo do dispositivo, corroborando com os sentidos mais pertinentes quanto aos terminais no Alq3 para se ter um transporte eletrônico satisfatório.
Resumo:
Coordenação de Aperfeiçoamento de Pessoal de Nível Superior (CAPES)
Resumo:
With the imposition of the suspension of production and subsequent banning of incandescent light bulbs will be necessary to replace it by other more energy-efficient. Although the main alternative is the compact fluorescent lamp, the environmental impact caused by it due to incorrect disposal and the amount of harmonics included in the network resulting in losses related to the quality of electric power system makes them sought new alternatives for lighting systems that are efficient and have low environmental impact. In this context, the LED (Lighting Emitting Diode), based on solid-state components, is presented as an option for new projects and replacement of existing lighting. In this work we studied aspects of energy, environmental and economic impacts of a possible replacement of conventional lighting systems for new technology. From laboratory tests and surveys of the costs of different types of lamps used for residential lighting, we performed a comparative analysis considering energy and economic aspects which showed that the LED technology, but has a high initial investment, it is best when power quality and environmental preservation are relevant factors in decision making for the choice of technology to be used in the lighting system
Resumo:
In-office dental bleaching has been subject of several studies. Generally those studies quantify through visual analysis, the shade reduction of the teeth submitted to different bleaching protocols (light sources, bleaching agent concentrations and irradiation time). The objective of this work is the determination of the influence of four irradiation protocols on the obtainment of better aesthetic results using a colorimetric spectrophotometer that quantifies color changes in each situation imposed. Forty bovine incisors were selected in function of similar anatomic characteristics; a concentrated coffee solution was used to stain the teeth. A commercial spectrophotometer was used to measure the color changes during evolution of the experiment (stain and bleaching phases) and the obtained data was analyzed by the ANOVA test. The obtained data showed the evolution of teeth color during the staining period, as well as, the color reduction that each bleaching protocol achieved. Based on our findings it is possible to conclude that bleaching protocols with larger irradiation periods did not showed significant differences when compared with shorter irradiation protocols, in that way the use of protocols with 30 min or more of consecutive irradiation are not clinically justified and also can cause several side effects.
Resumo:
Adequate polymerization plays an important role on the longevity of the composite resin restorations. Objectives: The aim of this study was to evaluate the effect of light-curing units, curing mode techniques and storage media on sorption, solubility and biaxial flexural strength (BFS) of a composite resin. Material and Methods: Two hundred and forty specimens were made of one composite resin (Esthet-X) in a stainless steel mold (2 mm x 8 mm 0), and divided into 24 groups (n=10) established according to the 4 study factors: light-curing units: quartz tungsten halogen (QTH) lamp and light-emitting diodes (LED); energy densities: 16 J/cm(2) and 20 J/cm(2); curing modes: conventional (CM) and pulse-delay (PD); and permeants: deionized water and 75% ethanol for 28 days. Sorption and solubility tests were performed according to ISO 4049:2000 specifications. All specimens were then tested for BFS according to ASTM F394-78 specification. Data were analyzed by three-way ANOVA followed by Tukey, Kruskal-Wallis and Mann-Whitney tests (alpha=0.05). Results: In general, no significant differences were found regarding sorption, solubility or BFS means for the light-curing units and curing modes (p>0.05). Only LED unit using 16 J/cm(2) and PD using 10 s produced higher sorption and solubility values than QTH. Otherwise, using CM (16 J/cm(2)), LED produced lower values of BFS than QTH (p<0.05). 75% ethanol permeant produced higher values of sorption and solubility and lower values of BFS than water (p<0.05). Conclusion: Ethanol storage media produced more damage on composite resin than water. In general the LED and QTH curing units using 16 and 20 J/cm(2) by CM and PD curing modes produced no influence on the sorption, solubility or BFS of the tested resin.
Resumo:
This work reports on the construction and spectroscopic analyses of optical micro-cavities (OMCs) that efficiently emit at ~1535 nm. The emission wavelength matches the third transmission window of commercial optical fibers and the OMCs were entirely based on silicon. The sputtering deposition method was adopted in the preparation of the OMCs, which comprised two Bragg reflectors and one spacer layer made of either Er- or ErYb-doped amorphous silicon nitride. The luminescence signal extracted from the OMCs originated from the 4I13/2→4I15/2 transition (due to Er3+ ions) and its intensity showed to be highly dependent on the presence of Yb3+ ions.According to the results, the Er3+-related light emission was improved by a factor of 48 when combined with Yb3+ ions and inserted in the spacer layer of the OMC. The results also showed the effectiveness of the present experimental approach in producing Si-based light-emitting structures in which the main characteristics are: (a) compatibility with the actual microelectronics industry, (b) the deposition of optical quality layers with accurate composition control, and (c) no need of uncommon elements-compounds nor extensive thermal treatments. Along with the fundamental characteristics of the OMCs, this work also discusses the impact of the Er3+-Yb3+ ion interaction on the emission intensity as well as the potential of the present findings.
Resumo:
Polypyridylkomplexe von Ruthenium(II) besitzen eine Vielzahl von Anwendungen, z. B. in Farbstoff-sensibilisierten Solarzellen und als Photokatalysatoren. [Ru(bpy)3]2+ ist einer der prominentesten Ruthenium(II)-Komplexe und besitzt langlebige angeregte 3MLCT-Zustände mit einer Lebensdauer von 1 µs und einer Lumineszenz-Quantenausbeute von 10%. [Ru(bpy)3]2+ ist chiral und kann Stereoisomere bilden, wenn die Liganden unsymmetrisch substituiert sind oder im Falle von oligonuklearen rac/meso-Komplexen. Bis-tridentate Komplexe wie [Ru(tpy)2]2+ sind achiral und umgehen damit unerwünschte Stereoisomere. [Ru(tpy)2]2+ besitzt jedoch enttäuschende photophysikalische Eigenschaften mit einer 3MLCT-Lebensdauer von nur etwa 0.2 ns und einer Quantenausbeute von ≤ 0.0007%. Die Anbringung von Substituenten an [Ru(tpy)2]2+ sowie die Aufweitung der Liganden-Bisswinkel auf 90° bewirken deutlich verbesserte Eigenschaften der emittierenden 3MLCT-Zustände. rnDieser Strategie folgend wurden in der vorliegenden Arbeit neue bis-tridentate Ruthenium(II)-Komplexe entwickelt, synthetisiert und charakterisiert. Durch Anbringen von Ester-Substituenten und Verwenden von Liganden mit erweiterten Bisswinkeln konnten 3MLCT-Lebensdauern von bis zu 841 ns und Quantenausbeuten von bis zu 1.1% erreicht werden. Die neuen bis-tridentaten Komplexe weisen eine deutlich erhöhte Photostabilität im Vergleich zu tris-bidentatem [Ru(bpy)3]2+ auf. rnDie Komplexe wurden als Emitter in Licht-emittierenden elektrochemischen Zellen eingebaut und zeigen Elektrolumineszenz mit einer tiefroten Farbe, die bis ins NIR reicht. Ebenso wurden die Komplexe als Lichtsammler in Farbstoff-sensibilisierten Solarzellen getestet und erreichen Licht-zu-Energie-Effizienzen von bis zu 0.26%. rnDinukleare, stereochemisch einheitliche Ruthenium(II)-Komplexe wurden oxidiert um die Metall-Metall-Wechselwirkung zwischen Ru(II) und Ru(III) in der einfach oxidierten Spezies zu untersuchen. Die unterschiedlichen Redoxeigenschaften der beiden Rutheniumzentren in den verwendeten dinuklearen Verbindungen führt zu einer valenzlokalisierten Situation in der keine Metall-Metall-Wechselwirkung beobachtet wird. Ebenso wurde die Oxidation eines einkernigen Ruthenium(II)-Komplexes sowie dessen spontane Rückreduktion untersucht.rnEnergietransfersysteme wurden mittels Festphasensynthese hergestellt. Dabei ist ein Bis(terpyridin)ruthenium(II)-Komplex als Energie-Akzeptor über eine unterschiedliche Anzahl an Glycineinheiten mit einem Cumarin-Chromophor als Energie-Donor verknüpft. Bei einer kleinen Zahl an Glycineinheiten (0, 1) findet effektiver Energietransfer vom Cumarin- zum Ruthenium-Chromophor statt, wogegen bei zwei Glycineinheiten ein effektiver Energietransfer verhindert ist.rnLicht-induzierte Ladungstrennung wurde erreicht, indem Bis(terpyridin)ruthenium(II)-Komplexe als Chromophore in einem Donor-Chromophor-Akzeptor-Nanokomposit eingesetzt wurden. Dabei wurde ein Triphenylamin-enthaltendes Blockcopolymer als Elektronendonor und ZnO-Nanostäbchen als Elektronenakzeptor verwendet. Bei Bestrahlung des Chromophors werden Elektronen in die ZnO-Nanostäbchen injiziert und die Elektronenlöcher wandern in das Triphenylamin-enthaltende Blockcopolymer. rnrn
Resumo:
Laser irradiation has numerous favorable characteristics, such as ablation or vaporization, hemostasis, biostimulation (photobiomodulation) and microbial inhibition and destruction, which induce various beneficial therapeutic effects and biological responses. Therefore, the use of lasers is considered effective and suitable for treating a variety of inflammatory and infectious oral conditions. The CO2 , neodymium-doped yttrium-aluminium-garnet (Nd:YAG) and diode lasers have mainly been used for periodontal soft-tissue management. With development of the erbium-doped yttrium-aluminium-garnet (Er:YAG) and erbium, chromium-doped yttrium-scandium-gallium-garnet (Er,Cr:YSGG) lasers, which can be applied not only on soft tissues but also on dental hard tissues, the application of lasers dramatically expanded from periodontal soft-tissue management to hard-tissue treatment. Currently, various periodontal tissues (such as gingiva, tooth roots and bone tissue), as well as titanium implant surfaces, can be treated with lasers, and a variety of dental laser systems are being employed for the management of periodontal and peri-implant diseases. In periodontics, mechanical therapy has conventionally been the mainstream of treatment; however, complete bacterial eradication and/or optimal wound healing may not be necessarily achieved with conventional mechanical therapy alone. Consequently, in addition to chemotherapy consisting of antibiotics and anti-inflammatory agents, phototherapy using lasers and light-emitting diodes has been gradually integrated with mechanical therapy to enhance subsequent wound healing by achieving thorough debridement, decontamination and tissue stimulation. With increasing evidence of benefits, therapies with low- and high-level lasers play an important role in wound healing/tissue regeneration in the treatment of periodontal and peri-implant diseases. This article discusses the outcomes of laser therapy in soft-tissue management, periodontal nonsurgical and surgical treatment, osseous surgery and peri-implant treatment, focusing on postoperative wound healing of periodontal and peri-implant tissues, based on scientific evidence from currently available basic and clinical studies, as well as on case reports.
Resumo:
III-nitride nanorods have attracted much scientific interest during the last decade because of their unique optical and electrical properties [1,2]. The high crystal quality and the absence of extended defects make them ideal candidates for the fabrication of high efficiency opto-electronic devices such as nano-photodetectors, light-emitting diodes, and solar cells [1-3]. Nitride nanorods are commonly grown in the self-assembled mode by plasma-assisted molecular beam epitaxy (MBE) [4]. However, self-assembled nanorods are characterized by inhomogeneous heights and diameters, which render the device processing very difficult and negatively affect the electronic transport properties of the final device. For this reason, the selective area growth (SAG) mode has been proposed, where the nanorods preferentially grow with high order on pre-defined sites on a pre-patterned substrate
Resumo:
The laser diode (LD) is a unique light source that can efficiently produce all radiant energy within the narrow wavelength range used most effectively by a photosynthetic microorganism. We have investigated the use of a single type of LID for the cultivation of the well-studied anoxygenic photosynthetic bacterium, Rhodobacter capsulatus (Rb. capsulatus). An array of vertical-cavity surface-emitting lasers (VCSELs) was driven with a current of 25 mA, and delivered radiation at 860 nm with 0.4 nm linewidth. The emitted light was found to be a suitable source of radiant energy for the cultivation of Rb. capsulatus. The dependence of growth rate on incident irradiance was quantified. Despite the unusual nearly monochromatic light source used in these experiments, no significant changes in the pigment composition and in the distribution of bacteriochlorophyll between LHII and LHI-RC were detected in bacterial cells transferred from incandescent light to laser light. We were also able to show that to achieve a given growth rate in a light-limited culture, the VCSEL required only 30% of the electricity needed by an incandescent bulb, which is of great significance for the potential use of laser-devices in biotechnological applications and photobioreactor construction. (c) 2006 Wiley Periodicals, Inc.
Resumo:
We report on recent progress in the generation of non-diffracting (Bessel) beams from semiconductor light sources including both edge-emitting and surface-emitting semiconductor lasers as well as light-emitting diodes (LEDs). Bessel beams at the power level of Watts with central lobe diameters of a few to tens of micrometers were achieved from compact and highly efficient lasers. The practicality of reducing the central lobe size of the Bessel beam generated with high-power broad-stripe semiconductor lasers and LEDs to a level unachievable by means of traditional focusing has been demonstrated. We also discuss an approach to exceed the limit of power density for the focusing of radiation with high beam propagation parameter M2. Finally, we consider the potential of the semiconductor lasers for applications in optical trapping/tweezing and the perspectives to replace their gas and solid-state laser counterparts for a range of implementations in optical manipulation towards lab-on-chip configurations. © 2014 Elsevier Ltd.